Test Method For Adhesive Strength
Test Method For Adhesive Strength
,
WUENSCH PLASTER .J
� •..,� ..• , t ..,--
tW4 �
I
FACTORY CO.
Al Ojaimi Industrial City - Al Kharj Road c->-3-1 &>� ·"-�-d...,...�I �I '1.....!-'--"'
\ll"i\i-Ll""L.)I ,1DDV1,L. ..,..,.<->"'
P.O.Box: 355734,Riyadh 1 1383
Kingdom of Saudi Arabia ,,Lu�I 4..:-!�1.a..Sl.,.ll
Tel:(+966) 500065799, Fax:(+966)112147706 (+''11)llf\£VV·1,�� ,(+''11)D· · ·1DV'l.'Lw
E-mail: [email protected] info@wuenschplaster com ,._;9�pl ...,_,__,.JJ
Website:www.wuenschplaster.com WWW. wuenschplaster.com' �9-'°
1. SCOPE
This work procedure for the method under laboratory temperature and humidity conditions to determine the
Tensile adhesion strength of cementitious ceramic tile adhesives.
2.REFERENCES
• Standard: BS EN 12004 (BS EN 1348)
3. RESOURCES
• Ceramic tiles with facial dimensions of (50 ± 1) mm x (50 ± 1) mm.
• The concrete slab shall comply with EN 1323
• Mass capable of exerting a force of (20 ± 0,05) N,
• Square metallic plates 50 ± 1 mm x 50 ± 1 mm x thickness of 10 mm
• Tensile testing machine (Proceq)
• Notched trowel having 6mm x 6mm notches at 12mm centres.
4. TEST CONDITIONS
Standard conditions shall be (23 ± 2) °C and (50 ± 5) % relative humidity and a speed of air in the testing
area ·of less than 0,2 m/s.
M
Al Ojaimi Industrial City - Al Kharj Road
P.O.Box: 355734,Riyadh 1 1 383 I I fAf - ,rbLJl , lo oVl! ,-.,.1o
Kingdom of 5audi Arabia ,.lrrg-r-t rjl a-- r-gjl ; <l oll
Tel: (+966) 500065799, Fax (+966)1't 2147706 (+111)il t)tw.1,o"sl-6 (+11i)0. . .'t0V11 ,g
E-mail: [email protected] info@wuenschplaster com,u/g)rsjf l lJcJl
Website: www. wuenschplaster.com www. wuenschplaster.com, yr
C.R. No:1010322377 \'\'fYYl"W:&U/
VAT No: 310153801 1 00003
6.PROCEDURE
. Will apply a thin layer of the adhesive to the concrete slab with a straight edge trowel,
o Then apply a thicker layer and comb with a notched trowel,
o The trowel shall be held at an angle of approximately 60' to the substrate at a right angle to one
edge of the slab and drawn across the slab parallel to that edge (in a straight line).
o After 5 min place tiles on the adhesive at a distance apart of 50 mm and load each tile with (2010,05)
N for 30 s,
o After 27 days of storage under standard conditions, attach the pull-head plates to the tiles with a
suitable high strength adhesive,
. Determine the tensile adhesion shength of the adhesive by applying force at a constant rate of (250
+ 50) N/s after 24 hours of further storage under standard conditions.
. Report results in Newton,
vlt
Quali$ Controller
ARTIIN JOSEF
-t$L'llLitfLJ*rflry"*
QC DEPT.