DP Series SC20A Series: 20 Watts

The SC20ADP Series is a line of economical 20 watt DC/DC converters with single or dual outputs. They feature an ultra-wide input voltage range of 9-36 Vdc, 18-75 Vdc, or 36-75 Vdc. Key features include remote shutdown, 200kHz switching frequency, continuous short circuit protection, and UL/cUL/EN safety certifications. Applications include telecommunications, distributed power systems, automatic test equipment, and process control.

Uploaded by

Anderson Matos
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

DP Series SC20A Series: 20 Watts

The SC20ADP Series is a line of economical 20 watt DC/DC converters with single or dual outputs. They feature an ultra-wide input voltage range of 9-36 Vdc, 18-75 Vdc, or 36-75 Vdc. Key features include remote shutdown, 200kHz switching frequency, continuous short circuit protection, and UL/cUL/EN safety certifications. Applications include telecommunications, distributed power systems, automatic test equipment, and process control.

Uploaded by

Anderson Matos
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SC20ADP Series

Series

20 Watts
Single/Dual Outputs

„ 4:1 ultra wide input range


9-36 Vdc
18-75 Vdc
36-75 Vdc
„ Remote shutdown
„ 200kHz switching frequency
„ Continuous short circuit
123456789012345678901234567890121234567 protection
123456789012345678901234567890121234567
123456789012345678901234567890121234567 „ Six-sided shielding
123456789012345678901234567890121234567
123456789012345678901234567890121234567 „ UL1950, cUL, EN60950
123456789012345678901234567890121234567
123456789012345678901234567890121234567
123456789012345678901234567890121234567
123456789012345678901234567890121234567
INPUT
123456789012345678901234567890121234567
123456789012345678901234567890121234567
T
Voltage Range 9-36 Vdc
123456789012345678901234567890121234567 he SC20A series is an economi-
123456789012345678901234567890121234567 18-75 Vdc
123456789012345678901234567890121234567 cally priced 20 watt DC/DC
123456789012345678901234567890121234567 36-75 Vdc converter featuring ultra-wide
123456789012345678901234567890121234567
Reverse Polarity Protected To Nominal Input Current
123456789012345678901234567890121234567 input range, efficiencies to 85% and a
123456789012345678901234567890121234567 External Fuse Required continuous six-sided shielded case.
123456789012345678901234567890121234567
Remote On/Off Control All Models
123456789012345678901234567890121234567 Telecom models (-48) feature thermal
123456789012345678901234567890121234567 shutdown and undervoltage lockout
123456789012345678901234567890121234567
123456789012345678901234567890121234567
OUTPUT compatible with ETS 300 132-2 para-
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Voltage Tolerance ± 1% graph 4.6. Other key features include:
123456789012345678901234567890121234567
Ripple and Noise 50mV pk-pk (typ) overvoltage protection, output trim
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Trim Adjusatble ±10% adjustability, TTL and CMOS compat-
123456789012345678901234567890121234567 ible remote on/off, short circuit protec-
123456789012345678901234567890121234567
Short Circuit Protection Continuous Power Cycle
123456789012345678901234567890121234567
Temperature Coefficient 0.02% / °C tion and small size. The SC20A series
123456789012345678901234567890121234567 measures only 1.6” x 2.0” x 0.40” and
123456789012345678901234567890121234567
123456789012345678901234567890121234567
GENERAL offers a power density of 15.7 watts/cu.
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Regulation: in.
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Line 0.25%
123456789012345678901234567890121234567
Load 0.5% (singles) Applications
123456789012345678901234567890121234567
123456789012345678901234567890121234567 1.0% (duals) These units are ideally suited for
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Efficiency 80-85% (typ) telecommunications, distributed power
123456789012345678901234567890121234567
I/O Isolation 1500 Vdc systems, automatic test equipment,
123456789012345678901234567890121234567
123456789012345678901234567890121234567 geosource test equipment and process
123456789012345678901234567890121234567
123456789012345678901234567890121234567
ENVIRONMENTAL control.
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Operating Temperature -40°C to +60°C
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Max Baseplate Temp 105°C
123456789012345678901234567890121234567
Storage Temperature -55°C to +105°C
123456789012345678901234567890121234567
123456789012345678901234567890121234567
Cooling Free-air Convection
123456789012345678901234567890121234567
123456789012345678901234567890121234567
123456789012345678901234567890121234567
123456789012345678901234567890121234567
All specifications are typical at nominal line and full load at 25°C unless
123456789012345678901234567890121234567
otherwise noted and are subject to change without notice.

17
SC20A Series Ordering Information

Input Voltage Output Output Model


Range Voltage Current Number

9-36 Vdc 3.3 Vdc 4500mA SC20A17-450-18


9-36 Vdc 5 Vdc 4000 mA SC20A11-400-18
9-36 Vdc 12 Vdc 1670mA SC20A12-167-18
9-36 Vdc 15 Vdc 1340mA SC20A13-134-18
9-36 Vdc ±12 Vdc ±840mA SC20A22-167-18
9-36 Vdc ±15 Vdc ±667mA SC20A23-134-18
18-75 Vdc 3.3 Vdc 4500mA SC20A17-450-46
18-75 Vdc 5 Vdc 4000mA SC20A11-400-46
18-75 Vdc 12 Vdc 1670mA SC20A12-167-46
18-75 Vdc 15 Vdc 1340mA SC20A13-134-46
18-75 Vdc ±12 Vdc ±840mA SC20A22-167-46
18-75 Vdc ±15 Vdc ±667mA SC20A23-134-46
36-75 Vdc 3.3 Vdc 4500mA SC20A17-450-48
36-75 Vdc 5 Vdc 4000mA SC20A11-400-48
36-75 Vdc 12 Vdc 1670mA SC20A12-167-48
36-75 Vdc 15 Vdc 1340mA SC20A13-134-48
36-75 Vdc ±12 Vdc ±840mA SC20A22-167-48
36-75 Vdc ±15Vdc ±667mA SC20A23-134-48

Dimensions and Connections

NOTES:
1. Ripple measured with a 3.3 µF tantalum
capacitor across each output.
2. Minimum load 10% of full load. Load regulation
from full load to minimum load.
3. The SC20A series requires an external filter
capacitor across the input valued at 2.2µF @
100Vdc such as ITW/Paktron part# 225K100RA4
or equiv.
4. Case conected to pin #1 on -46 and -48 models.
Case connected to pin #2 on -18 models

External Output Trimming: Output may be externally


trimmed ±10%.
PIN CONNECTIONS PIN CONNECTIONS Remote ON/Off Control (pin 4) common referenced
Single Output dual Outputs to - Input (pin 2).
1. +Input 1. +Input On greater than 2.5 Vdc or open circuit
2. -Input 2. -Input Off less than 0.8 Vdc
3. No Pin 3. No Pin
4. Remote On/Off 4. Remote On/Off
5. No Pin 5. +Output
6. +Output 6. C ommon
7. Common 7. -Output
8. Trim 8. Trim 11/01/2001

18 14C Industrial Way Atkinson, NH 03811 (603) 893-2330 FAX (603) 893-6280