0% found this document useful (0 votes)
66 views

HF115F I

This document provides information on a miniature high power relay. It has a maximum inrush of 120A for 20ms and is 15.7mm in height. It has a 5kV dielectric strength between coil and contacts and 10mm creepage distance. It is compliant with various standards including VDE, IEC, UL and RoHS. Contact data, coil data, and characteristics are provided including insulation resistance, dielectric strength, temperature rise and shock/vibration resistance. Ordering information includes type, coil voltage, contact arrangement and construction. Outline dimensions, wiring diagram and PCB layout are shown.

Uploaded by

home made
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views

HF115F I

This document provides information on a miniature high power relay. It has a maximum inrush of 120A for 20ms and is 15.7mm in height. It has a 5kV dielectric strength between coil and contacts and 10mm creepage distance. It is compliant with various standards including VDE, IEC, UL and RoHS. Contact data, coil data, and characteristics are provided including insulation resistance, dielectric strength, temperature rise and shock/vibration resistance. Ordering information includes type, coil voltage, contact arrangement and construction. Outline dimensions, wiring diagram and PCB layout are shown.

Uploaded by

home made
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

HF 115 F -I MINIATURE HIGH POWER RELAY

Features
● Max high inrush:120A 20ms
File No.:E134517
● Low height: 15.7 mm
● 5kV dielectric strength (between coil and contacts)
V ● Creepage distance: 10mm
D E
● Meeting VDE 0700, 0631 reinforce insulation
File No.:116934 ● Product in accordance to IEC 60335-1 available
● Sockets available
● Plastic sealed and flux proofed types available
● UL insulation system: Class F
File No.:CQC17002168381 RoHS compliant

CONTACT DATA COIL


Contact arrangement 1A, 1C Coil power Approx. 400mW
Contact resistance 1) 100m max.(at 1A 6VDC)
Contact material AgSnO2 COIL DATA at 23
Contact rating 16A 250VAC Pick-up Drop-out
Nominal Max. Coil
NO: TV-5 80A Voltage Voltage
Inrush rating (120VAC) Voltage VDC Voltage Resistance
VDC
120A / 20ms VDC min.1) VDC 2)
max.1)
Max. switching voltage 440VAC / 300VDC
5 3.50 0.5 7.5 62 x (1 10%)
Max. switching current 16A
Max. switching power 6 4.20 0.6 9.0 90 x (1 10%)
4000VA
Mechanical endurance 1 x 107OPS 9 6.30 0.9 13.5 202 x (1 10%)
1H3A type: 7.5 x 104OPS (16A 250VAC,
12 8.40 1.2 18 360 x (1 10%)
General use, Room temp.,
Electrical endurance 1s on 9s off) 810 x (1 10%)
18 12.6 1.8 27
1H3A type: 2.5 x 104OPS (TV-5 120VAC,
Room temp., 1s on 59s off) 24 16.8 2.4 36 1440 x (1 10%)
Notes: 1) The data shown above are initial values.

CHARACTERISTICS 483) 33.6 4.8 72 5760 x (1 15%)

Insulation resistance 1000M (at 500VDC) 60 3) 42.0 6.0 90 7500 x (1 15%)

Dielectric Between coil & contacts 5000VAC 1min 110


3)
77.0 11.0 165 25200 x (1 15%)
strength Between open contacts 1000VAC 1min Notes: 1) The data shown above are initial values.
Notes: 2) Maximum voltage refers to the maximum voltage which relay
Surge voltage (between coil & contacts) 10kV (1.2 / 50µs) coil could endure in a short period of time.
3) For products with rated voltage ≥ 48V, measures should be
Operate time (at nomi. volt.) 15ms max. taken to prevent coil overvoltage in order to protect coil in
Release time (at nomi. volt.) 8ms max. test and application (eg. Connect diodes in parallel).

Temperature rise (at nomi. volt.) 55K max.


SAFETY APPROVAL RATINGS
Functional 98m/s2
Shock resistance *
Destructive 980m/s2 HF115F-I....1Z(S)3A NO: 16A 250VAC at 85°C
Vibration resistance * 10Hz to 150Hz 20g/5g UL/CUL 16A 250VAC
Humidity 5% to 85% RH HF115F-I....1H(S)3A
TV-5,120VAC
Ambient temperature -40 to 85
HF115F-I....1H(S)3A 16A 250VAC at 85°C
Termination PCB VDE
Unit weight Approx. 13.5g HF115F-I....1Z(S)3A NO: 16A 250VAC at 85°C
Plastic sealed, Notes: 1) All values unspecified are at room temperature.
Construction Flux proofed 2) Only typical loads are listed above. Other load specifications
Notes: 1) The data shown above are initial values. can be available upon request.
2) * Index is not that of relay length direction.

HONGFA RELAY
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED 2020 Rev. 1.00

226
ORDERING INFORMATION

HF 115 F - I / 0 1 2 -1 H S 3 A (XXX)
Type

Coil voltage 5, 6, 9, 12, 18, 24, 48, 60, 110VDC

Contact arrangement 1H: 1 Form A 1Z: 1 Form C


1)2)
Construction S: Plastic sealed Nil: Flux proofed

Version 3: 5.0mm

Contact material A: AgSnO2

Special code3) XXX: Customer special requirement Nil: Standard


Notes: 1) We recommend flux proofed types for a clean environment (free from contaminations like H2S, SO2, NO2, dust, etc.).
We suggest to choose plastic sealed types and validate it in real application for an unclean environment (with contaminations
like H2S, SO2, NO2, dust, etc.).
2) Contact is recommended for suitable condition and specifications if water cleaning or surface process is involved in assembling relays
on PCB.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
4) Two packing methods available: plastic tray package, tube package,Standard tube packing length is 616mm. Any special requirement
needed, please contact us for more details.
5) For products that should meet the explosion-proof requirements of "IEC 60079 series",please note [Ex] after the specification while placing
orders.Not all products have explosion-proof certification,so please contact us if necessary, in order to select the suitable products.

OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm

Outline Dimensions
12.7 0.3

6x0.5x0.8
0.5x0.5

PCB Layout Wiring Diagram


(Bottom view) (Bottom view)

2.6 5.04
7.56

1 Form A 1 Form A

6x 1.3 20.16

5.04
2.6 5.04
7.56

1 Form C 1 Form C

8x 1.3 20.16

Remark: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
3) The width of the gridding is 2.52mm.

227
CHARACTERISTIC CURVES

ENDURANCE CURVE COIL OPERATING RANGE (DC) *

3.6
1000

3.4

3.0
100

2.6

2.2

1.8 16 A
10
1.4
Recommended
voltage
1.0

0.6
1 0 +20 +40 +60 +80 +100
0 2 4 6 8 10 12 14 16

Contact Current (A) Ambient Temperature ( )

Test conditions: Notes: * The use of a relay with an energising voltage


NO, 250VAC, Resistance Load, other than the rated coil voltage may lead to
Flux proofed, Room temp., 1s on 9s off reduced electrical life.
An energising voltage over the abover range
may damage the insulation of relay coil.

Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.

228