4012-46TAG2A

1467 kW Gross @ 1500 rpm


4000
ElectropaK Series

Basic technical data Centre of gravity of bare engine


Number of cylinders .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... 12 Wet, forward from rear of block.. .. ... .. ... .. ... .. ... .. ... .. ... .. 771 mm
Cylinder arrangement.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ...V Wet, above centre line of block.. .. ... .. ... .. ... .. ... .. ... .. ... .. . 32 mm
Cycle.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 4 stroke
Induction system.. .. ... .. ... .. ... .. ... Quad turbocharged, aftercooled Moments of inertia (mk2)
Compression ratio.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 12.8:1 Engine rotational components (excluding flywheel) .. .. ... .. 9.46 kgm2
Bore .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... 160 mm Flywheel and starter ring.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... 9.55 kgm²
Stroke .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. . 190 mm
Displacement.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 45.84 litres
Operation
Direction of rotation (viewed from flywheel).. .. ... .. ... .. Anticlockwise
Steady state stability at constant load .. .. ... .. .. ISO 8528-5 Class G3
Firing order (cylinder 1 furthest from flywheel) .. .. .. . .. .. . .. .. . .. .. . .. .. .
.. .. ... .. ... .. ... .. ... .. . 1A, 6B, 5A, 2B, 3A, 4B, 6A, 1B, 2A, 5B, 4A, 3B Cyclic irregularity for standby engine (110%).. .. ... .. ... .. ... .. ... 1.544

Notes:
Weight of ElectropaK • Perkins maintains ISO9001:2000 certified quality management
systems for engine test facilities to assure accurate calibration of
Temperate test equipment
Dry (estimated) .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. . 5663 kg • all data based on operation to ISO 3046-1:2002 standard
Wet (estimated) .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 6024 kg reference conditions
• for engines operating at increased ambient temperate and/or
Tropical altitude conditions please refer to the relevant derate tables
Dry (estimated) .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. .5690 kg • all data is subject to a tolerance of ±5% in addition to the stated
Wet (estimated) .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 6050 kg power delivery tolerance
• unless otherwise stated all measurements and limits are quoted
for Standby power conditions
Overall dimensions of ElectropaK • please refer to the relevant Operation and Maintenance Manual
(OMM) for engine servicing details including coolant, fuel, oil and
Temperate Diesel Exhaust Fluid (DEF) requirements where applicable
Height .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 2269 mm
• for additional product information please contact Perkins
Length.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 3915 mm Applications Engineering
Width .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 2200 mm

Tropical
Height .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 2269 mm
Length.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 3915 mm
Width .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 2200 mm

Optional document version control


This document should be used as reference guide for installation purposes and where required can be submitted as part of business tender
submissions. The table below may be used upon request to validate that this Technical Data Sheet is the latest version available.

Project name/tender name Date Perkins authorised sign

1 of 6
Publication No. TPD2317 Issue 2, April 2021.
Copyright © 2021 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
General installation
Type of application
Designation Units 50 Hz @ 1500 rpm
Baseload Prime/DCP Standby
Gross engine power output kW 1077 1339 1467
Gross BMEP kPa 1879 2337 2560
Mean piston speed m/s 9.5
Temperate kW 1032 1294 1422
Nett mechanical power output
Tropical kW 1005 1267 1395
Combustion air flow m3/min 103.6 116.2 123.8
Exhaust gas temperature at turbocharger outlet ºC 375 401 416
Exhaust gas flow at conditions stated above m3/min 227.5 264.2 288.1
Overall thermal efficiency (gross) % 41.9 42.4 41.8
kWe 980 1229 1351
Temperate
Typical generator set kVA 1226 1537 1689
electrical output (0.8pf) kWe 955 1204 1325
Tropical
kVA 1193 1505 1657
Assumed alternator efficiency % 95 95 95

Reference conditions for technical data


Air temperature .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 25ºC Relative humidity.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . 30%
Barometric pressure .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 100 kPa Fuel temperature (inlet pump).. .. .. . .. .. . .. .. . .. .. . .. 58ºC (maximum)

Energy balance1
Type of application
Designation Units 50 Hz @ 1500 rpm
Baseload Prime/DCP Standby
Energy in fuel kWt 2570.7 3156.1 3512.1
Energy in power output (gross) kW 1077 1339 1467
Energy to cooling fan and Temperate kWm 45
battery charging alternator Tropical kWm 72
Energy to exhaust2 kWt 832.3 1017.8 1136.4
Energy to charge air kWt 245.8 314.3 376.1
Energy to coolant radiator kWt 338.5 393.0 430.0
Energy to radiation (atmosphere)3 kWt 77.1 92.0 102.6

Rating definitions
Baseload power
Unlimited hours usage with an average load factor of 100 percent of the published Baseload power rating. No overload is permitted.

Prime power
Unlimited hours usage with an average load factor of 80 percent of the published Prime power over each 24-hour period.
A 10 percent overload is available for 1 hour in every 12 hours operation.

Data Centre Power (DCP)4


Power available for variable or continuous electrical loads in a Data Centre application. Up to 100 percent load factor is permitted for unlimited time.
An overload of 10 percent permitted for 1 hour in every 12 hours of operation. DCP Power definition relies on ISO8528-1 2018 standard to be
followed by generator set manufacturer, and will support Tier I to Tier IV classifications of Data Centres as per UPTIME institute guidelines.

Standby power
Limited to 500 hours usage with an average load factor of 80 percent of the published Standby power rating over each 24-hour period.
Up to 300 hours of annual usage may be run continuously. No overload is permitted.

Footnotes:
1. Data included in the energy balance table should not be used for combined heat and power (CHP) purposes.
2. Not to be utilised for heat recovery, does include energy input from combustion air.
3. Includes heat rejected to fuel via return to tank flow.
4. All Data Centre projects must be approved by Perkins, prior to tender submission. Project details must be submitted to Perkins sales representative to obtain approval.

2 of 6
Publication No. TPD2317 Issue 2, April 2021.
Copyright © 2021 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
Cooling system Fan type
ElectropaK coolant capacity (with radiator) -
Temperate .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .223.5 litres Temperate
Tropical.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 223 litres Fan type.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . Mechanical, fixed
Engine coolant capacity (without radiator) .. .. ... .. ... .. ... .. ...73 litres Configuration .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . Pusher
Maximum top tank temperature .. .. ... .. ... .. ... .. ... .. ... .. ... .. .. 98ºC Diameter (tip to tip).. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .1650 mm
Maximum static pressure head on pump.. .. ... .. ... .. ... .. ... .. 70 kPa Number of blades.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ..8
Coolant temperature rise across engine.. .. ... .. ... .. ... .. ... .. ... .. 8ºC Material.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. . Plastic
Thermostat operation range (closed to fully open) .. .. ... .. 71 to 85ºC Drive ratio .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .0.79:1
Water temperature switch or alarm setting.. .. ... .. ... .. ... .. ... . 103ºC
Tropical
Specifications Units 50 Hz @ 1500 rpm Fan type.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . Mechanical, fixed
Engine coolant flow at Configuration .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . Pusher
litres/min 970
maximum restriction Diameter (tip to tip).. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .1650 mm
Engine coolant circuit - Number of blades.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 10
kPa 20
maximum allowed restriction
Material.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. . Plastic
Charge air cooler restriction
kPa 12 Drive ratio .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .0.79:1
at full load (maximum)
Compressor outlet
temperature at standard ºC 194 Duct allowance
25ºC test condition
Compressor outlet Temperate
pressure at standard kPa 241
25ºC test condition 50 Hz @
Units
1500 rpm
Charge air cooler outlet
temperature at standard ºC 45 Duct allowance5 Pa 250
25ºC test condition Ambient
Standby ºC 45.3
clearance6

Radiator Resultant minimum airflow m3/sec 22.9

Temperate Tropical
Radiator face area .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 3.61 m 2
50 Hz @
Units
Core material .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. .. Copper/brass 1500 rpm
Number of rows.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . 3 Duct allowance5 Pa 125
Fins per inch.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . 7.26
Ambient
Standby ºC 54.5
Width of matrix .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 2089 mm clearance6
Height of matrix.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 1730 mm Resultant minimum airflow m /sec
3
30.2
Weight of radiator.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 1263 kg
Pressure cap setting .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. 70 kPa
Fuel system
Tropical Fuel injection pump.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ..Unit injection
Radiator face area .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 3.61 m2 Fuel injector type.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. . Mechanical
Core material .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. .. Copper/brass Mechanical injector opening pressure.. .. ... .. ... .. ... .. ... .. 23.4 MPa
Number of rows.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . 3 Filtration media size .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 10 μm
Fins per inch.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . 6.86 Fuel lift pump type.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. Mechanical
Width of matrix .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 2089 mm Maximum low-pressure system fuel flow rate.. .. ... .. ... 1200 litres/hr
Height of matrix.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 1730 mm Maximum low-pressure system pressure.. .. ... .. ... .. ... .. ... 350 kPa
Weight of radiator.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 1290 kg Maximum fuel temperature at fuel pump inlet.. .. ... .. ... .. ... .. ... 58ºC
Pressure cap setting .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. 70 kPa Governor type .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. Electronic
Fuel cooler included7.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. Yes

Footnotes:
5. Maximum additional cooling airflow restriction.
6. Ambient clearance allows for 5°C rise above ambient temperature at fan.
7. Where fuel cooler is provided, component details can be found on GA drawing.

3 of 6
Publication No. TPD2317 Issue 2, April 2021.
Copyright © 2021 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
Fuel specification Maximum engine operating angles
Recommended fuel conformity.. .. ... .. ... .. . BS2869 A2 or BS EN590 Front up, front down .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... 5°
Maximum sulphur in fuel limit .. .. ... .. ... .. ... .. ... .. ... .. ... .. 500 ppm Right side up, right side down .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .10°

Fuel consumption8
Induction system
1339 kW @ 1500 rpm Maximum air intake restriction (clean filter) .. .. ... .. ... .. ... .. ... . 2 kPa
Prime/DCP Prime/DCP Maximum air intake restriction (dirty filter).. .. .. . .. .. . .. .. . .. .. . .. 4 kPa
load condition %
g/kWh Air filter type .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. Dry
110 (standby) 202 Number of air filters.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 2

100 199
75 202
Exhaust system
Number of exhaust outlets.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ...2
50 205
Exhaust outlet diameter .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ..254 mm
Exhaust outlet flange size and type.. .. ... .. ... .. ... .. .. 10 inch table D
Load acceptance9 Maximum back pressure at turbocharger outlet .. .. ... .. ... .. ... .5 kPa
The engine speed governing complies with the requirements of
classification 3 and 4 of ISO 8528-12 and to G2 and G3 operating
limits stated under ISO 8528-5.
Electrical system
Alternator output voltage.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 24 V
Alternator output current .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 55 amps
Lubricating system
Starter motor input voltage.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . 24 V
Total system capacity Starter motor power draw.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 16.4 kW
Maximum sump capacity (maximum dipstick mark) .. .. ... .157.5 litres Number of teeth on flywheel.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 156
Minimum sump capacity (minimum dipstick mark) .. .. ... .. ... 115 litres Number of teeth on starter pinion .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... 12
Maximum oil temperature (continuous operation).. .. ... .. ... .. ..105°C Minimum average cranking speed .. .. .. . .. .. . .. .. . .. .. . .. .. . .. 120 rpm
Maximum oil temperature (intermittent operation).. .. ... .. ... .. . 110°C Engine stop method .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . Electronic

Lubricating oil
Relief valve opening pressure.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 400 kPa
Engine mounting
Minimum oil pressure.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 340 kPa Maximum static bending moment at rear face of block.. .. ... . 1356 Nm
Oil pressure at maximum no load speed.. .. ... .. ... .. ... .. ... .. 400 kPa Maximum additional load applied to flywheel
due to all rotating components .. .. ... .. ... .. ... .. ... .. ... .. ... .. . 850 kg
Oil flow at rated speed.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... 360 litres/min
Oil consumption .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 0.26% of fuel
Oil grade .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. API CI4 15W40

Cold start recommendations10


Minimum battery cold cranking amps Minimum battery cold cranking amps
Minimum starting temperature Engine oil with block heaters without block heaters
grade
°C CCA CCA
API C14
-10 4 x 12V x 810A N/A
15W40
API CI4
Maximum battery cold cranking amps (CCA) 4 x 12V x 1600A N/A
15W40

Footnotes:
8. For conversion to litres/hr use the following formula with the correct fuel density: SFC (kg/kWh)
x Power (kW) = Fuel Consumption (litres/hr)
Fuel density (kg/litre)
9. Please contact Perkins Applications Engineering for any further information.
10. Cold cranking amps as per SAEJ537.

4 of 6
Publication No. TPD2317 Issue 2, April 2021.
Copyright © 2021 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
Noise data
Noise data of the ElectropaK, this excludes exhaust outlet noise except where specifically stated, measured in a semi-anechoic environment.
Measurements taken in accordance with ISO 6798-1:2020.

Raw exhaust outlet noise level at


ElectropaK turbocharger outlet
Average sound pressure level11,12 (LpA) at 1m (dBA) Exhaust sound power level13 (LWA) (dBA)
50 Hz @ 1500 rpm 50 Hz @ 1500 rpm
114.1 127.6

Sound distribution around ElectropaK Microphone positions


Position Sound pressure level (LpA) at 1m (dBA)
(reference diagram) 50 Hz @ 1500 rpm 5 1 8
1 114.0
1m
2 114.4

3 111.3

4 114.3

5 115.4
2 9 4
6 113.3

7 112.9

8 114.8

9 115.0

6 3 7
Front of engine

Footnotes:
11. Sound pressure reference level: 20 μPa.
12. Average 1m sound pressure level to sound Power conversion add 15.1 dB.
13. Sound power reference level: 1pW.

5 of 6
Publication No. TPD2317 Issue 2, April 2021.
Copyright © 2021 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
Spectral data
/ Octave sound data for the ElectropaK and exhaust outlet noise level at turbocharger outlet.
1 3

Third octave centre frequency (Hz)


50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8k 10k 12.5k 16k 20k

Exhaust noise LWA dBA


70.3 80.3 90.1 95.6 101.2107.8 116.5 119.6 116.6 113.1 117.6 117.3 114.7 111.5 112.2 113.3 111.4 114.5 114.7 113.2 113.1 113.5 112.8 112.1 109.4103.0 99.4
50 Hz at 1500 rpm

ElectropaK noise LpA


at 1m dBA 61.1 68.7 73.6 74.5 84.1 89.0 104.2102.2103.4106.4104.4103.0102.9103.3104.7104.2103.2102.3103.2100.5 99.0 97.9 97.6 95.4 93.6 81.8 71.5
50 Hz at 1500 rpm

Sound spectra

140

120
Sound pressure at 1m / sound power (dBA)

100

80

60

40

20

0
50

63

80

100

125

160

200

250

315

400

500

630

800

1000

1250

1600

2000

2500

3150

4000

5000

6300

8k

10k

12.5k

16k

20k
Third octave centre frequency (Hz)

Exhaust noise LwA dBA ElectropaK noise LpA at 1m dBA


50 Hz at 1500 rpm 50 Hz at 1500 rpm

6 of 6
Publication No. TPD2317 Issue 2, April 2021.
Copyright © 2021 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com

You might also like