This document provides information on the OPTIFLUX 4000 electromagnetic flow sensor, including that it is a robust and reliable sensor that is the first choice in the field with over 250,000 units in operation. It lists specifications like operating in liquids down to 1us/cm conductivity and up to 180°C temperature. The document consists primarily of a table that provides detailed part numbering and configuration options for the OPTIFLUX 4000 sensor.

Uploaded by

Leandro Alan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views19 pages

OPTIFLUX 4300 HPrec (Rango Caudalimetros)

This document provides information on the OPTIFLUX 4000 electromagnetic flow sensor, including that it is a robust and reliable sensor that is the first choice in the field with over 250,000 units in operation. It lists specifications like operating in liquids down to 1us/cm conductivity and up to 180°C temperature. The document consists primarily of a table that provides detailed part numbering and configuration options for the OPTIFLUX 4000 sensor.

Uploaded by

Leandro Alan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

10/2006

First choice in electromagnetic flowmeters


Robust and reliable
250,000 units in operation
Conductivity down to 1us/cm
Temperature up to 180° C
CERT
DIN ISO 9001
OPTIFLUX 4000
OPTIFLUX 4000
OPTIFLUX 4000

5
OPTIFLUX 4000
10/2006
Item list 2006 Electro magnetic flow sensor OPTIFLUX 4000 F Page 09 Rev.01
for flow converter IFC 010 C / W, IFC 040 C & IFC 300 C / F / W / R. OPTIFLUX 4000
DN 10 - DN 150 / 3/8" - 6"
DC-field operation for liquids with conductivity > 1 (water > 20) µS/cm. (IFC 300)
DC-field operation for liquids with conductivity > 5 (water > 20) µS/cm. (IFC 010 & 040)

Code flow sensor


VN03 4 Nominal diameter
1 4000 F DN 10 / 3/8" PTFE flanges 1/2"
2 4000 F DN 15 / 1/2" PTFE
3 4000 F DN 20 / 3/4" PTFE
4 4000 F DN 25 / 1" PFA
5 4000 F DN 32 PFA ( not for IFC 040 C )
6 4000 F DN 40 / 1 1/2" PFA ( not for IFC 040 C )
7 4000 F DN 50 / 2" PFA
8 4000 F DN 65 PFA
A 4000 F DN 80 / 3" PFA
B 4000 F DN 100 / 4" PFA
C 4000 F DN 125 PFA
D 4000 F DN 150 / 6" PFA
Nominal pressure
A ASME B 16.5 150 lb RF
3A ANSI 300 lb
6A ANSI 600 lb
9A ANSI 900 lb RF
9J ANSI 900 lb RTJ
15A ANSI 1500 lb RF
15J ANSI 1500 lb RTJ
Approval ( in combination with IFC 040 or 300 for Ex only )
0 non Ex
1 EEx zone 1
3 EEx zone 2
5 FM Class 1 DIV 2
A CSA GP
C CSA Class 1 DIV 2
F SAA zone 1 *** In preparation / pending.
G SAA zone 2 *** In preparation / pending.
H TIIS zone 1 *** In preparation / pending.
K TIIS zone 2 *** In preparation / pending.
System design / cable connection
1 Compact with aluminum converter housing / at converter
2 Compact with stainless steel converter housing / at converter
3 Modular / without
4 Separate with aluminum connection box / 1/2" NPT
5 Separate with aluminum connection box / PF 1/2
6 Separate with aluminum connection box / M20 x 1.5
A Separate with stainless steel connection box / 1/2" NPT
B Separate with stainless steel connection box / PF 1/2
C Separate with stainless steel connection box / M20 x 1.5
Converter model
0 Without / modular
1 IFC 010 C ( compact design )
2 IFC 010 W ( wall mount version )
6 IFC 040 C ( compact design )
C IFC 300 C ( compact design )
D IFC 300 F ( field mount version )
E IFC 300 W ( wall mount version )
F IFC 300 R ( rack mount version )
Lining
0* Standard
2 PTFE - provided for protection rings ( DN 10 / 3/8" - DN 20 / 3/4" )
S PFA - provided for protection rings ( DN 25 / 1" - DN 150 / 6" )
T ETFE - Tefzel

Electrodes ( fixed )
1 Stainless steel DIN 1.4571 - 316 Ti
2 Stainless steel DIN 1.4401 - 316
3* Hastelloy C4 ( standard )
4 Hastelloy B2
5 Tantalum
6 Titanium
7 Platinum
G Low noise (aluminumoxide) - Base HC4
U Low noise (aluminumoxide) - Base DIN 1.4571 - 316 Ti
Page 10 Rev.01
OPTIFLUX 4000

VN03 4 Construction of electrodes


1* Fixed
Housing- / flange material
1* Steel / steel St 37-C22 / A 105
3 Steel / stainless steel DIN 1.4404 - 316 L
Protection class / dimension
0* IP 66 / 67 / standard
1 IP 68 field / standard ( only with stainless st. connection box )
2 IP 68 factory / standard ( only with stainless st. connection box )
3 IP 66 / 67 / ISO 13359
4 IP 68 field / ISO 13359 ( only with stainless st. connection box )
5 IP 68 factory / ISO 13359 ( only with stainless st. connection box )
Cable
0* Compact - without / separate DS
1 Separate BTS
2 Separate LIYCY ( only for FM / CSA Class 1 DIV 2 )
Cable length
0* Compact - none / separate - 5 m - 15 ft
1 10 m - 30 ft
2 15 m - 45 ft
3 20 m - 60 ft
4 25 m - 75 ft
5 30 m - 90 ft
6 40 m - 120 ft
7 50 m - 150 ft
8 100 m - 300 ft
Calibration
0* Standard
1 304 / 1.4301 tagplate ( 67 x 25 mm )
A Custody transfer ( DN 25 - 150 / 1 - 6" )
B Custody transfer + 304 / 1.4301 tagplate ( 67 x 25 mm )
Ring / -material
0* Without
1 Ring #1 / 1.4571 - 316 Ti
2 Ring #1 / Hastelloy C4
4 Ring #1 / Tantalum
5 Ring #1 / Titanium
A Ring #3 / 1.4571 - 316 Ti
H Protection ring #2 / 1.4571 - 316 Ti
K Protection ring #2 / Hastelloy C4
N Protection ring #2 / Titanium
Construction requirements
0* Standard
1 Group 1
2 Group 2
3 Group 3
QA / QC requirements
0* Standard
1 Group 1
2 Group 2
3 Group 3

* Standard
*** In preparation / pending.
VN03 4 0 00 0000 Complete
ordering code
Item list 2006 Electro magnetic flow sensor OPTIFLUX 4000 F Page 11 Rev.01
for flow converter IFC 010 C / W & IFC 300 C / F / W / R. OPTIFLUX 4000
DN 200 - DN 600 / 8" - 24"
DC-field operation for liquids with conductivity > 1 (water > 20) µS/cm. (IFC 300)
DC-field operation for liquids with conductivity > 5 (water > 20) µS/cm. (IFC 010)

Code flow sensor


VN04 4 Nominal diameter
E 4000 F DN 200 / 8" ETFE
E 4000 F DN 200 / 8" PTFE
E 4000 F DN 200 / 8" Hard Rubber
F 4000 F DN 250 / 10" ETFE
F 4000 F DN 250 / 10" PTFE
F 4000 F DN 250 / 10" Hard Rubber
G 4000 F DN 300 / 12" ETFE
G 4000 F DN 300 / 12" PTFE
G 4000 F DN 300 / 12" Hard Rubber

Nominal pressure
A ASME B 16.5 150 lb RF
3A ANSI 300 lb
6A ANSI 600 lb
9A ANSI 900 lb
15A ANSI 1500 lb RF
15J ANSI 1500 lb RF

Approval ( in combination with IFC 300 for Ex only )


0 non Ex
1 EEx zone 1
3 EEx zone 2 *** In preparation / pending.
5 FM Class 1 DIV 2
A CSA GP
C CSA Class 1 DIV 2
F SAA zone 1 *** In preparation / pending.
G SAA zone 2 *** In preparation / pending.
H TIIS zone 1 *** In preparation / pending.
K TIIS zone 2 *** In preparation / pending.
System design / cable connection
1 Compact with aluminum converter housing / at converter
2 Compact with stainless steel converter housing / at converter
3 Modular / without
4 Separate with aluminum connection box / 1/2" NPT
5 Separate with aluminum connection box / PF 1/2
6 Separate with aluminum connection box / M20 x 1.5
A Separate with stainless steel connection box / 1/2" NPT
B Separate with stainless steel connection box / PF 1/2
C Separate with stainless steel connection box / M20 x 1.5
Converter model
0 Without / modular
1 IFC 010 C ( compact design )
2 IFC 010 W ( wall mount version )
C IFC 300 C ( compact design )
D IFC 300 F ( field mount version )
E IFC 300 W ( wall mount version )
F IFC 300 R ( rack mount version )
Lining
0* Standard - ETFE
1 PTFE
2 PTFE - provided for protection rings
5 Hardrubber ( only for Ex version )
Page 12 Rev.01
OPTIFLUX 4000

VN04 4 Electrodes ( fixed )


1 Stainless steel DIN 1.4571 - 316 Ti
2 Stainless steel DIN 1.4401 - 316
3* Hastelloy C4 ( standard )
4 Hastelloy B2
5 Tantalum
6 Titanium
7 Platinum
G Low noise (aluminumoxide) - Base HC4
U Low noise (aluminumoxide) - Base DIN 1.4571 - 316 Ti
Construction of electrodes
1* Fixed
Housing- / flange material
1* Steel / steel St 37-C22 / A 105
3 Steel / stainless steel DIN 1.4404 - 316 L
Protection class / dimension
0* IP 66 / 67 / standard
1 IP 68 field / standard ( only with stainless st. connection box )
2 IP 68 factory / standard ( only with stainless st. connection box )
3 IP 66 / 67 / ISO 13359
4 IP 68 field / ISO 13359 ( only with stainless st. connection box )
5 IP 68 factory / ISO 13359 ( only with stainless st. connection box )
Cable
0* Compact - without / separate DS
1 Separate BTS
2 Separate LIYCY ( only for FM / CSA Class 1 DIV 2 )
Cable length
0* Compact - none / separate - 5 m - 15 ft
1 10 m - 30 ft
2 15 m - 45 ft
3 20 m - 60 ft
4 25 m - 75 ft
5 30 m - 90 ft
6 40 m - 120 ft
7 50 m - 150 ft
8 100 m - 300 ft
Calibration
0* Standard
1 304 / 1.4301 tagplate ( 67 x 25 mm )
A Custody transfer
B Custody transfer + 304 / 1.4301 tagplate ( 67 x 25 mm )
Ring / -material
0* Without
1 Ring #1 / 1.4571 - 316 Ti
2 Ring #1 / Hastelloy C4
4 Ring #1 / Tantalum
5 Ring #1 / Titanium
A Ring #3 / 1.4571 - 316 Ti
H Protection ring #2 / 1.4571 - 316 Ti
K Protection ring #2 / Hastelloy C4
N Protection ring #2 / Titanium
Construction requirements
0* Standard
1 Group 1
2 Group 2
3 Group 3
QA / QC requirements
0* Standard
1 Group 1
2 Group 2
3 Group 3

* Standard
*** In preparation / pending.
VN04 4 0 00 0000 Complete
ordering code
Item list 2006 Flow converter IFC 300 for flow sensor Page 30a Rev.01
OPTIFLUX 1000 / 2000 / 4000 / 5000 / 6000 / 7000 (DC-field operation). IFC 300

Basic version

Code flow converter


VN30 4 Type
4 IFC 300 C
5 IFC 300 C / CAP
B modular IFC 300 / ( non EEx )
H IFC 300 F
L IFC 300 R
N IFC 300 W
Power supply
1 12 - 24 V DC ( 12 - 24 V DC )
4 24 V DC / AC ( 19 - 29 V )
A 100 - 230 V AC ( 85 - 250 V AC, 50/60 Hz )
Ex-version
0 without - non Ex
1 EEx zone 1 ( terminal compartment "d" - C )
2 EEx zone 1 ( terminal compartment "e" - C, F )
3 EEx zone 2
5 FM Class 1 DIV 2
A CSA GP
C CSA Class 1 DIV 2
F SAA zone 1
G SAA zone 2
H TIIS zone 1
K TIIS zone 2
Cable connection
4 3 x 1/2" NPT
5 3 x PF 1/2"
6 3 x M20 x 1,5
B Strip: tag ( only for R version )
Instruction manual / Operating language
1 German / german
2 English GB / english GB
3 English US / english US
4 French / french
5 Without / german
6 Without / english GB
7 Without / french
P Japanese / japanese
R Chinese / chinese
S Russian / russian
V Without / japanese
W Without / chinese
X Without / russian
Custody transfer
0* Without
1 Water, KIWA BKR 618/4 - NL ***
2 Water, OIML R49 - GE
3 Water, OIML R49 - EN ***
4 Water, OIML R49 - FR ***
A Other than water, OIML R117 - NL ***
B Other than water, OIML R117 - GE
C Other than water, OIML R117 - EN ***
D Other than water, OIML R117 - FR ***
Proces diagnostics
0* Standard
4 Batchcontrolling - BC
Converter housing
1 Standard
2 St. st. 1.4408 ( for Compact )
2 St. st. 1.4408 ( for Field )
3 Aluminum ( C & F ), custody transfer: sealed
4 Stainless steel ( C & F ), custody transfer: sealed ( for Compact )
4 Stainless steel ( C & F ), custody transfer: sealed ( for Field )
5 Polyamide ( W ), custody transfer: sealed
Page 31a Rev.01
IFC 300

VN30 4 Communication
1* Basic IO (CO + PO + 2* status)
1-st IO Module
0* Without, no module possible
2-nd IO Module
0* Without, no module possible
Reference Method
0* Standard
1 Virtual reference
Tagplate
0* standard, without
1 304 / 1.4301 tagplate ( 67 x 25 mm )

* Standard
*** In preparation / pending.
VN30 4 0 0 Complete ordering code