API 650 Part 2
API 650 Part 2
BA Subject
APIStandard 650
Issue Date
06/98 02/00
Page
26
30. For foundations specified to besloped from a horizontal plane, the actual elevation shall
not deviatefrom the calculated differcnces bymore than which of the following where
concrete ringwalls are not provided?
a) t1/8* in any 30" of the circumference and + N2" in the total circumference
measured from the average clevation
b) t1/8*" in any 10' of the circumference and +1¥2 in the total circumference
tl/8" in athy 10' of thecircumference and +1/4" in the total circumference
measured from the average elevation
d) t1/8" inany 30' of the circumference and +1/4" in the total circumference
Reference API-650. Paragraph 5.5.5.3 (b)
Answers to API-Standard 650 Section 5, Erection
Should you find a mistake or disagree with any answer listed, please bring i to our attention
for correction or clarification.
BAY Technical Associates, Inc. has attempted to provide answers developed from
paragraphs of' the respectiveCode. Standard,or Recommended Practice.
You can reach BAY Tech by phone at (610) 594-9036, by lax at (610) $94-2612, or by
e-mail at byagle(@gte.net.
BA Subject
APIStandard 650 06/98 02/00 28
are required to be
3/8* to not over 1" in thickness
6. For butt welded joints in plates oover 3/8" and less. What additional
Tadiographically examined to the same extent as plates
spot examination does API-650 require for these welded joints? t22 l6)
a) 50 percent of all vertical and horizontal junctions
b) 75 percent of all vertical and horizontal junctions
c) 100 percent of all vertical and horizontal junctions
course
d) 25 percent of all horizontal joints between the first and second
Reference: API-650, Paragraph 6.1.2.2(b)
joints shall show at least
7. The radiographic film for all junctions of vertical and horizontal
of weld length on each side of the vertical intersection.
a) 3 inches
b) 2 inches
c) Iinch
d) 4 inches
9. After the initial spot radiograph in the first 10 feet of horizontalbutt joint, additional spot
radiographs shallbe taken at what increment?
a) One radiograph shall be taken in each additional 200 feet
b) One radiograph shall be taken ineach additional 100feet
c) One radiograph shall be taken in each additional 300 feet
d) One radiograph shall be taken in each additional 150 feet
11. Personnel who perform and cvaluate radiographic examinations accordingto API-650
shallbe qualified and certified bythe manufacturer as meeting the requirements as
generally outlined in
a) Level Il or Level III of ASNT SNAT-TC-1B
b) Level llor Level |ll of ASNTSNT-TC-1B
c) Level IIor Level Illof ASNT SNAT-TC-1A
d) Level Ilor Level Ill of ASNT SNT-TC-1A
Reference: API-650, Paragraph 6.1.3.2
12. The acceptance standards for radiographic examinations shall be in accordance with
which of the following?
a) Paragraph UW-51(b) in Section VII of the ASME Code
b) Paragraph PW-S1 (b) in Section I of the ASME Code
c) Paragraph 341.3.2 in B31.3 Process Piping of the ASME Code
d) Paragraph RB-3233 in the National Board Inspection Code (NBIC)
17. Liquid penetrant examination shall be performed in accordance with a written procedure.
The examiner shall have his/her vision checked and be able to read which of the
following?
a) The liquid penetrant written procedure at a distancenot less than 12 inches
b) A Jaeger Type 2 standard chart at a distance not less than 12 inches
c) AJaeger Type lstandard chart at adistance not less than 12 inches
d) A Jaeger Type 3standard chart at a distance not less than 12inches
Reference API-650, Paragraph 6.4.2 and 6.4.3 (a)
18. Undercutting of welds attaching nozzles, manholes, cleanout openings, and permanent
attachments shall not exceed which of the following?
a) Undercutting shallnot exceed 1/64th inch
b) Undercutting shall not exceed 3/32nd inch
c) Undercutting shall not exceed 1/32nd inch
d) Undercutting shall not exceed 3/64" inch
A
C
7 B
D
9 A
10
11 D
12 A
13 B
14
15
16 D
17 B
18 A
Should youfind a mistake or disagree with any answer listed. please bring it to our attention
for correction or clarification.
BAY Technical Associates, Inc. has attenmpted to provide answers developed from
paragraphs of the respective Code, Standard, or Recommended Practice.
You can reach BAY Tech by phone at (610) 594-9036, by fax at (610) 594-2612, or by
e-mail at [email protected].
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
Issue Datc
Revision Date Page
BA Subject
APIStandard 650 06/98 02/00 32
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
Issue Date Revision Date Page
BA Subject
API Standard650 06/98 02/00 33
4 B
A
D
Should you find a mistake or disagree with any answer listed, please bring i to our attention
for correction or clarification.
BAY Teechnical Associates, Ine. has attempted to provide answers developed trom
paragraphs of the respective Code. Standard, or Recommended Practice.
You can reach BAY Tech by phone at (610) 594-9036, by fax at (610) 594-2612, or by
e-mail at byaglegle.net.
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) $94-9036
Issuc Date Revision Date Page
BA Subject
APIStandard 650 06/98 02/00 34
Section 8- Marking
tanks made in accordance with API-650.
I. A nameplate shall identify abovepround storage
Where must this nameplate be located on the completed tank?
adjacent to a manhole or to a
a) This nameplate shall be attached to thetank shell
manhole reinforcing plate immediately tothe right of the manhole
to a vertical weld joint
b) This nameplate shall beattached to the tank shelladjacent
at least 48" above the shell-to-botom weld joint manhole or to a
c)Ahis nameplate shall be attached to the tank shell adjacent to a
manhole reinforcing plate immediately above the manhole
d) This nameplate shall be attached to the tank shelladjacent to a manhole or to a
manhole reinforcing plate immediately below the manhole
Should you find a mistake or disagree with any answer listed, please bring it to our atention
for correction or clarification.
BAY Technical Associates, Inc. has attempted to provide answers developed from
paragraphs of the respective Code. Standard, or Recommended Practice.
Youcan reach BAY Tech by phone at (610) 594-9036. by lax at (610) 594-2612, or by
e-mailat [email protected].
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
Issue Date Revision Date Page
BA Subject
API Standard 650 (06/98 02/00 35
1. What is the maximum shell thickness including corrosion allowance permitted for lanks
that comply Appendix Aof API-650?
a) 7/8" inch
b) 3/4h inch
c) S/8" inch
d) 1/2 inch
4. What joint efficiency factor shall be used in the design of small tanks designed in
accordance with Appendix Aof API-650 when spot radiographicexamination is applied?
a) 1.00
A34
b) 0.90
0.85
d) 0.70
3 B
4
D
Should you find a mistake or disagree with any answer listed, please bring it to our attention
for correction or clarification.
BAY Technical ASsOciates, Inc. has attempted to provide answers developed from
paragraphs of the respective Code, Standard, or Recommended Practice.
You can reach BAY Tech by phone at (610) 594-9036, by fax at (610)594-2612, or by
e-mail at byagle(@gte.net.
5. How far below the owest adjacent finish grade must the bottonm of the ringwall, it' founded on
soil, be located?
The bottom of the ringwall shall be located Ifoot below grade
The bottom of the ringwallshall be located 1.5 feet below grade
B ) The bottom of the ringwall shallbe located 2.5 feet below grade
The bottom of the ringwallslhall be located 2 feet below grade
Reference API-650, Paragraph B.4.2.2
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
Issue Date Revision Date Page
BA Subject
APIStandard 650 06/98 02/00 38
Should you find a mistake or disagree with any answer listed, please bring it to our attention
for correction or clarification.
BAY Technical Associates, Inc. has attempted to provide answers developed from
paragraphs of the respective Code, Standard, or Recommended Practice.
You can reach BAY Tech by phone at (610) 594-9036, by fax at (610) 594-2612, or by
e-mail at [email protected].
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
Issue Date Revision Date Page
BA Subjcct
API Standard650 06/98 02/00 39
5. Floating roof support legs and attachments shall be designed to support the roof and a
uniform live load of at least per square foot.
a) 100 pounds
b) 75 pounds
S0 pounds
(d25 pounds
Reference API-650, Paragraph C.3. 10.2
API-653 Exam Prep Course BAY Tl'echnical Associates, Inc. (610) 594-9036
|Issue Date Revision Date Page
BA Subject
APIStandard 650 06/98 02/00 40
ventilation.
O. Manholes are required in floating roofs for access to thetank interior and for
What is the minimum nominal diameter of thesc manholes?
a)) 24 inches
20 inches
c) 18 inches
d) 15 inches
7.\1fsteel
theshoes,
scalingwhat
devicematerial
between the outer periphery of the roof and the tank shellemploys
shall these shoes be made of and what is the minimum nominal
thickness permitted?
a) The shoes shall be made from galvanized sheet ASTM A924 with a minimum
thickness of 14 gauge
b) The shoes shall be made from galvanized sheet ASTMA 924 with a minimum
thickness of 16 gauge
c) The shoes shall be made from galvanized sheet ASTM A924 with a minimum
thickness of 18 gauge
d) The shoes shall be made from galvanized sheet ASTM A 924 with a minimum
thickness of 20 gauge
Reference API-650, Paragraph C.3.13
8. Drainpipe and hose systems of primary drains shall be tested with water at a pressure of
a) 0.5 psig
b) 5.0 psig
c) 50 psig
d) 50 ksig
Reference API-650, Paragraph C.4.5
Answers to API-Standard 650 Appendix C- External Floating Roofs
Question Number Answer
2
3
4 B
D
6 A
7 B
8
Shouldyou find a mistake or disagree with any answer listed, please bringit to our attention for
correction or clarification. BAY Teclhniçal Associates, lnc. has attempted to provide answers
developed from paragraphs of the respective Code, Standard, or Recommended Practice. You can
reach BAY Tech by phone at (610)594-9036, by fax at (610) 594-2612, or by e-mail at
byagle(@gte.net.
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
BA Subject
APIStandard 650
Issue Date
06/98
Revision Date
02/00
Page
41
2. Aluminum dome roof shall be supported only from the rim of the tank. The design of the
connectionshall allow for thermal expansion. What is the minimum temperature range
that must be used for the design?
Altl10°F
120°F
+125°F
d) +130°F
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
Revision Date Page
Issue Date
BA Subject
APIStandard 650 06/98 02/00 42
Supported
Answers to AP-Standard 650 Appendix G- Structuraly
Aluminum Dome Roofs
Question Number Answer
1 D
B
3
4 D
to our attention
Shouldyou find a mistake or disagree with anyanswer listed, please bring it
for correction or clarification.
BAY Technical Associates, Inc. has attempted to provide answers developed from
paragraphs of the respective Code, Standard, or Recommended Practice.
Youcan reach BAY Tech by phone at (610) 594-9036, by fax at (610) 594-2612, or by
e-mail at byagle @gte.net.
API-653 Exam Prep Course BAY Technical Associales, Inc. (610) 594-9036
Issue Date
BA Subjcct
APIStandard 650 06/98
Revision Date
02/00
Page
43
Which of the following is not permitted as a design for internal tloating roots in contact
with the liquid?
a) Double deck
b) Pontoon
Metallic Pan
Metallic onfloats
Reference API-650, Paragraph ||.5.1.1
(610) S94-9036
API-653 Exam Prep Course BAY Technical ASsociates, Inc.
Revision Date Page
BA Subject
APIStandard 650
Issue Date
06/98 02/00 44
Metallic intermal roofs on floats shall be designed to be buoyant enough to support how
much weight?
a) Twice its dead vweight
b Twice the weight of two men
500 pounds per square foot
d Three times its dead weight
9. How many and what size manholes must be provided ina fixed roof for access to the
tank interior?
a) At least two with a nominal diameter of 24 inches each
b) Atleast three with a nominal diameter of 24 inches each
c) Atleast one with a nominal diameter of 24 inches
d) At least four with a nominal diameter of 24 inclhes each
10. When specified by the purchaser, inspection hatches shall be located on the fixed roof to
permit visual inspection of the seal regign, What is the maximum spacing between these
hatches?
a) 32 feet
b) 50feet
c), 75eet
d) T0o feet
API-653 Exam Prep Course BAY Technical Associates, Inc. (610) 594-9036
Issuc Date Revision Date
BA Subject
API Standard 650 06/98 02/00
Page
45
Should you find a mistake or disagree with any answer listed, please bring it to our attention
for correction or clarification.
BAY Technical Associates, Inc. has attempted to provide answers developed from
paragraphs of the respective Code, Standard, or Recommended Practice.
Youcan reach BAY Tech by phone at (610) 594-9036, by fax at (610) 594-2612, or by
e-mail at [email protected].