AADSS1230110

This document provides installation instructions for the 9200 Series Electric Strikes. It includes: 1) A list of product components including the strike body, cover, spacers, mounting screws, and pigtails. 2) Specifications for voltage, current draw, strength ratings, certifications, and operating temperatures. 3) Instructions for converting the strike between fail secure and fail safe modes and installing door stops. 4) Steps for surveying the installation area, measuring existing strike height, and marking for alignment of the new strike.

Uploaded by

Rennie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views

AADSS1230110

This document provides installation instructions for the 9200 Series Electric Strikes. It includes: 1) A list of product components including the strike body, cover, spacers, mounting screws, and pigtails. 2) Specifications for voltage, current draw, strength ratings, certifications, and operating temperatures. 3) Instructions for converting the strike between fail secure and fail safe modes and installing door stops. 4) Steps for surveying the installation area, measuring existing strike height, and marking for alignment of the new strike.

Uploaded by

Rennie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

9200 Series

Electric Strikes
Installation & Operating Instructions

Product Components
B
A 9200 Strike Body G Door Stop/Rubber
Bumper Kit
B 9200 Cover
H Blind Nut
C 9200 1/8" Spacer
A
I Power Pigtail
D 5/16"–18 x 1"
Mounting Screws J LM/LMS Pigtail
(included with LM
E #12 Self Drilling C
and LMS only)
Lockdown Screws
K LMS In-Line Adapter
F #6-32 x 1/4"
Cover Screws

Specifications
Recommended Wire Gage For Distance F
200 Feet 200–300 300–400 9200W
Voltage Current
or Less Feet Feet
12 VDC 480 mA 18 16 16

16 VDC 640 mA 16 14 14

24 VDC 240 mA 22 22 20 G H 9200N (NA

UL1034 8 7 6 5 4 3 2
E 1

• Static Strength: • Endurance:


1500 lbs 250,000 cycles
D

D
D

• Dynamic Strength: • Outdoor Use


70 ft–lbs
I
UL294 Performance Levels
• Destructive • CAN/ULC 60839-11-1
C
J C

Attack: Level I • Listed for use with


• Line Security: Level I Grade 1 and Grade 2
• Endurance: Level IV Access Control
K
• Standby Power: Level I • Humidity: 93 %
• Outdoor Use • Temperature:
B
Diagram 1 B

-40° to 66° C
8-3/8"

ANSI BHMA A156.31*


9200W (WIDE)
• Grade 1 • Function #: E09361
A
A

DATE CREATED DRAWN BY DESIGNED BY

DOCUMENT ID SIZE

NOTE Installation wiring for the product and wiring DRAWING NUMBER (ALT ID)
B
REV

methods shall be in accordance ANSI/NFPA70 National


V6_11/11/20

Electrical Code, Canadian Electrical Code, part 1 and


8 7
9200N (NARROW)
6 5 4 CONFIGURATION Default LEGACY ID SHEET 1 OF 1

Local Authority Having Jurisdiction (AHJ). For ULC60839-


11-11 and UL294 complaint systems, DC power shall
be provided through a UL/cUL listed access control, or
burglar alarm power supply with class 2 limited output.
4-5/8"
1 of 4
Preparing the Strike

Factory Configuration
The HES 9200 Electric Strike is pre-
configured from the factory for FAIL
SECURE operation as shown. To SWITCH
from fail-secure to fail safe for either
configuration, loosen screws and
move solenoid closer to the keeper
pocket and secure. Diagram 1a Diagram 1a
The HES 9200 Electric Strike can be
converted for FAIL SAFE operation
as shown. Diagram 1b
SELECT correct Door Stop length for
application. Long stop for use with
full glass doors without a rail. Short
for use with solid door or glass door
with rail. INSTALL Door Stops with
Rubber Bumper. (part G, page 1)
Diagram 1b
Product must be installed according to all
applicable building and life safety codes.

Preparing the Frame

Pre-Installation
Survey HEADER

1 PERFORM an initial on-site survey to "X"


IF "X" IS LESS THAN
determine the mounting method and 3-1/4" ON FULL-GLASS DOORS OR
LESS THAN 2-1/2" FOR DOORS
review the installation plan. Diagram 2 WITH A 2" THICK TOP RAIL,
Take the following into consideration: A SECURITRON UHB AND/OR HEB
WILL NEED TO BE INSTALLED
TO THE HEADER TO EXTEND
• Physical strength of mounting THE MOUNTING SURFACE
areas should be strong enough AND PROPERLY SUPPORT
THE ELECTRIC STRIKE
to meet or exceed the holding
INTERIOR FACE
force of the existing strike. OF DOOR SURFACE

• Placement of the strike wiring Diagram 2


and protection from potential
damage due to intruders or
vandal’s external attack.
2 MEASURE height of existing strike. Use
included shim if height is 3/4". Do not
use shim if height is 5/8". Diagram 3
Diagram 3
3 MARK the front edge of the existing
HEIGHT
strike for proper alignment of OF
HEADER STRIKE
the new strike. Diagram 3

"X"
IF "X" IS LESS THAN
3-1/4" ON FULL-GLASS DOORS OR
LESS THAN 2-1/2" FOR DOORS WITH PENCIL
WITH A 2" THICK TOP RAIL, MARK THE EDGE
A SECURITRON UHB AND/OR HEB JUST IN FRONT
WILL NEED TO BE INSTALLED OF RAMPS
TO THE HEADER TO EXTEND
THE MOUNTING SURFACE
AND PROPERLY SUPPORT
2 of 4 THE ELECTRIC STRIKE

INTERIOR FACE
Preparing the Frame (CONTINUED)

If replacing an existing manual strike the HES CL CENTERLINE OF LATCHBOLTS


9200 should mount directly to the header
using the existing strike mounting holes. 13"

Only wire holes will need to be drilled. If it 5-9/16" 5-9/16"

is a new install, use the following steps: 1/2" 1-5/8


9200W WIRE 3X DRILL & TAP FOR 5/16-18 UNC
PASS-THRU 1/4" OR
1 MARK centerline of latchbolts to header. DRILL 17/32" HOLE
FOR BLIND NUTS
2 PUNCH, DRILL the marked mounting
holes as required. Diagram 4
CL 1-7/8"

3 PUNCH, DRILL the marked wire access CL

holes as required. Diagram 4 1-11/16" INTERIOR FACE OF 1-9/16" INTERIOR FACE OF


OUTLINE
1/2" THK GLASS 3/4" THK GLASS
OF
4 INSTALL mounting Blind Nuts (if STRIKE
needed). INCREASE hole size to "17/32"
4-7/8"
if using blind nuts. Diagram 4 1/2"
9200N WIRE
PASS-THRU

Diagram 4

Finishing the Installation


1 Connect power pigtail and LM/LMS pigtail Connector Pin-Outs If using the C1 — Latchbolt Monitor (LM) or
(if equipped) wires to existing wiring C1 — Latchbolt Monitor C1 — Latchbolt and Strike Monitor (LMS), use
coming out of the frame. Diagram 5 WHT Common the LM/LMS 6-pin Plug In Connector (pigtail)
and REFER to chart to complete wiring.
ORG Normally Closed
GRN Normally Open NOTE: For double doors the LM/LMS states will
C1 — Latchbolt and Strike Monitor only show secure when BOTH doors (LM) and
BRN Common electric strike (LMS) are secure. See Chart below.
BLU Normally Closed “Secure” means latch is detected & secured
YEL Normally Open within strike pocket for LM and the strke
C2 — 12/24 V Power is also in a locked state for LMS.
BLK 12/24 V– NOTE: Monitor options were not evaluated
Diagram 5 RED 12/24 V+ by UL294/UL1034/ULC60839-11-1.

LM Input LM Output Wire Condition


Door 1 Door 2 LM State Open Closed
Unsecure Unsecure Unsecure GRN & WHT ORG & WHT
WHT
ORG

GRN

BRN

RED
BLU

BLK
YEL

Secure Unsecure Unsecure GRN & WHT ORG & WHT


Unsecure Secure Unsecure GRN & WHT ORG & WHT
Secure Secure Secure ORG & WHT GRN & WHT
C2
LMS Fail Secure
LMS Input LMS Output Wire Condition
Solenoid 1 Solenoid 2 LMS State Open Closed
C1 Retracted Retracted Unsecure YEL & BRN BLU & BRN
Extended Retracted Unsecure YEL & BRN BLU & BRN
Retracted Extended Unsecure YEL & BRN BLU & BRN
Extended Extended Secure BLU & BRN YEL & BRN

LMS Fail Safe*


LMS Input LMS Output Wire Condition
Solenoid 1 Solenoid 2 LMS State Open Closed
Retracted Retracted Secure BLU & BRN YEL & BRN
Extended Retracted Unsecure YEL & BRN BLU & BRN
Retracted Extended Unsecure YEL & BRN BLU & BRN
Extended Extended Unsecure YEL & BRN BLU & BRN
* Adapter (K) must be used in this configuration.

3 of 4
Finishing the Installation
1 ELECTRICALLY CONNECT the 9200
(9200W Shown) to the pigtails,
and ATTACH the electric
strike to the header using the
5/16"-18 x 1" mounting screws
provided. Diagram 6
2 ALIGN front edge of latchbolt ramps
with marked line from Diagram 3.
3 CHECK the latchbolt interaction As required.
with the keepers to ensure proper See Diagram 3. Diagram 7
engagement and clearance. If front
and back, MACRO adjustment
is needed, ADJUST the strike
and RETIGHTEN the three
5/16"-18 x 1" mounting screws.
4 Check door play and adjust Door Diagram 6
Stops as needed for MICRO
adjustment using a slotted driver on
the back of the strike. Diagram 7
5 ADJUST the latchbolt depth into
the keeper pocket per the exit
device manufacturer’s instructions. Diagram 8
Ensure the latchbolt clears the
keeper pocket when the exit
device bar is manually depressed. Diagram 9
6 TEST the mechanical and electrical
operation to confirm the ability to
release, capture and detect the door.
7 LOCKDOWN Door Stop with
included 8-32 set screws.
(5/64 Allen Wrench)
Diagram 8
8 LOCKDOWN the front and
back adjustment using the
#12 self threading screws Diagram 10
illustrated. Diagram 9
9 INSTALL the cover, and SECURE
in place using the #6-32 x 1/4"
Cover Screws. Diagram 10

CAUTION Take care to not damage any of the


flex cables or printed circuit boards and remove
all metal debris before installing the cover.

10 Finished Installation. Diagram 11


Diagram 11

Printed in the U.S.A.


Patent pending and/or patent www.assaabloydss.com/patents

[email protected] Copyright © 2023, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
800 626 7590 | hesinnovations.com permission of Hanchett Entry Systems, Inc. is prohibited. 3089006.001_2

4 of 4