0% found this document useful (0 votes)
11 views

4 Fire Detection and Protection System

The fire detection and protection system consists of smoke detectors, heat detectors, manual call points, fire alarm panels, and other components to detect fires early and alert occupants. The addressable fire alarm control panel uses a dual wire analog bus system to identify device locations instead of wide areas, helping firefighters locate the exact source of the alarm. The system protects life and property by detecting fires early, evacuating occupants, notifying personnel, and activating auxiliary functions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views

4 Fire Detection and Protection System

The fire detection and protection system consists of smoke detectors, heat detectors, manual call points, fire alarm panels, and other components to detect fires early and alert occupants. The addressable fire alarm control panel uses a dual wire analog bus system to identify device locations instead of wide areas, helping firefighters locate the exact source of the alarm. The system protects life and property by detecting fires early, evacuating occupants, notifying personnel, and activating auxiliary functions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Fire Detection and Protection System

WHAT THIS PRODUCT DOES


A fire alarm system is intended to enable a fire to be detected at a sufficiently early stage so that people who are at risk can
be made safe either by escaping from the fire, or by the fire being extinguished (also to prevent extensive property damage).
Neither of these measures can be used until people are made aware of fire. The effectiveness of the fire detection and alarm
system depends on the stage of the fire at which it is operated. In order for all the occupants to escape without too much diffi-
culty, an early alarm should operate before the escape routes becomes smoke-logged to such an extent as will cause occupants
to have difficulty finding their way out of the building.
Fire Alarm Systems are used to protect life and property. It protects by:
a. detecting a fire at an early stage
b. alerting and evacuating occupants
c. notifying the relevant personnel
d. activating auxiliary functions e.g. smoke controls, lift homing etc
e. identifying and guiding fire fighters
The addressable fire alarm control panel is a dual wire analog bus system, it can replace the conventional fire alarm control
system to save 50% or more cables.
Each detector, module, manual call point, horn, strobe ,hydrant has its own independent address, the fireman or the guard can
find the exact fire alarm address instead of a wide area in conventional system.
1. Smoke Detector and Heat Detector
Components 3. Call Point
4. Pull Station
5. Fire Alarm siren sounder
6. Sound Beacon with Strobe
7. Fire Control Panel
8. Fire Extinguisher
9. Fire Door -
10. Fire Hydrant Pump
11. Fire Pump Control Panel
11. Gas Extinguishing Panel
12. Fire Hydrant 3. Fire Hose Cabinet
14. Fire Hose Reel
15. Hose Pipe
8 16. Sprinkler Head
Product Outline
Full System Network

Smoke Detector Heat Detector

Specifications Specifications
Type: Conventional / Non-Conventional Product: Heat Detector Sensor
Operating Voltage: 9-32 VCD Volts Input Voltage: DC 10-32V
Standby Current: ≤100uA 24 VDC Static Current: ≤50uA (DC 24V)
Alarm Current: 60mA (DV 24V)
Wiring Method: 2 bus system optical detector
Operating Temperature: 0°C- +80°C
Diameter: 4.0 Inch (103 mm) Alarm Reset: Power-off reset
Weight: 5.5 oz. (155 g) Installation: Ceiling mounted
Non-polarized: yes Wiring Mode: 2/3/4wire
Design: OEM/ODM Operating Humidity: ≤90% RH
Packaging Details: Plastic Alarm Temperature: 57°C/137F or 8-15°C/Min
Alarm Output: LED indication, network output
Function: Power-off reset function
Size: 100*45mm
Certificate: CE

9
Product Outline
Fire Control Panel

Specifications
32-bit MCU
2-wire communication between detector/module
Each detector sensitivity adjustable
Field-programmable with PS/2 standard PC keypad and mouse
7.4' LCD back-lit display
Windows menu and interface
English interface and panel display
Reset system setup file and history file to facilitate maintenance
Communicate with PC via USB
Single point start/stop of module (Menu operation)
Single point test of detector/module
Zone, building or floor display
CRT visually display the location of fire and trouble
Eleven users each with a password and selectable access levels
Field software upgrade
CAN Bus Implemented
Flexible collocation by modularized combination
Maximum simultaneous alarm of each host:
Fire alarm: 500 Trouble: 500 Feedback: 500
Operating Environment:
Temperature: -10 degree to +55 degree
Relative Humidity: less than 95%
AC Power: 220VAC, 50Hz, 3A
DC Power: 24VDC, 7.0Ah
CE certification

Fire extinguisher

Specifications
Uses: Fire
Types:
Foam extinguishers
Powder extinguishers
Carbon dioxide extinguishers (CO2)
Wet chemical extinguishers
Fire blankets
10
Product Outline
Fire Door

Specifications
Model Number: Aluminum Fire Door
Open Style: Swing
Position: Interior
Surface Finishing: Finished
Type: Sliding Doors
Sliding Door Type: Folding Doors
Product name: Folding glass garden door
Hinge: heavy folding glass door with hidden hinge
Alloy: 6063, 6060, 6005, 6061, 6082, 6101, 6106, etc.
Surface treatment: Anodizing, powder coating,
wood coating, electrophoresis, PVDF, etc.
Size: 0.5m - 11.85m, customized.
Shape: Customized.
Thickness: Customized.
Application: Architectual, industrial, decoration, etc.
Process: Drilling, Bending, welding, precise cutting, etc.
Standard: GB 5237-2008, ASTM B221, EN755-

Gas Extinguisher System

11
Product Outline
Call Point Pull Station

Specifications Specifications
Description: Manual Call point for fire alarm system Usage: Fire
Operating Voltage: 24V Working voltage: 220VAC/50Hz or 24VDC
Standard: EN54 Maximum current: 5A (220VAC/50Hz) or 8A (24VDC)
Terminal: Single Pole Contactor resistance: ≤0.1Ω
Usage: Fire alarm systems Machine: Fire alarm panel conventional/Addr
Material: ABS Plastic Wiring Method: 2 wire bus system
Certificate: CE Design: OEM/ODM
Color: Red, green, yellow, white available Colour: Red
Current: 5A

Fire Alarm Siren Sounder Fire Beacon with Strobe Sound

Specifications Specifications
Uses: Fire Usage: Fire
Operation Voltage: 24V DC (Typical) Product name: Fire Beacon and Strobe Sound Alarm
Color: Red Color: Red
Operation Current (at 24V DC): 50mA , 70mA Material: ABS
Sound Intensity ( at 1 meter ): 100 ± 5dB (at 24V DC) Working voltage: DC11V-27V
Siren tone Frequency: 2.5KHz ± 30% Working current: 40mA-60mA
Continue Operation Test: Over 4 hours (at 24V DC) Flash Period: less than 90 times/min
Material: POLYCARBONATE (UL 94 V-2) Temperature Range: -10 deg. to +50 deg.
Storage Temperature: -40 Min. to + 80 Max. (Degree C)
Humidity Range: 0%-95% RH
European IP -Norms: IP 55
Sound Pressure Lever: More than 100dB
12 Type of sound alarm: 3 kinds
Product Outline
Fire Hydrant Pump

Specifications
Theory: Centrifugal Pump, Centrifugal Pump
Structure: Multistage Pump, Single-stage Pump
Usage: Water
Power: Hydraulic
Standard or Nonstandard: Standard
Fuel: Diesel
Pressure: 0.6Mpa, 1.0Mpa,1.6 Mpa,
select according to pump head, High Pressure
Application: Fire, Sewage, fire fighting
Material: Cast iron
Operation: 1 Duty(electric)+
1 standby(diesel engine)+1 jockey
Capacity: 30 to 2000 GPM pressure 4 to 20 bar
Pressure vessel: 25,50,75,100…Liters, ATPH
Power: 7KW~550KW
Speed: 740-3000 r/min
Altitude: <=1000m

Fire Pump Control Panel


Specifications
Fire pump controllers are control panels contain-
ing electrical components such as circuit breaker,
witches, relays and other devices dedicated to the
operation of fire pumps. The devices within a fire
pump controller panel perform such functions as
receiving signals from alarm devices, such as pres-
sure operated switches, sprinkler alarm valves or
remote fire alarm equipment; activating motor
control devices to provide electric power to
motors driving fire pumps and monitoring the fire
pump operation and performance. All controllers
are completely assembled. The Control panel is
used mainly to re-operate and re-command the
following devices with Auto control of electric
pump, diesel engine pump and jockey pump with
overload, over current protection...
13
Product Outline
Fire Hydrant

Details...
A fire hydrant, also called a fireplug, fire pump, johnny pump, or simply pump, is a connection
point by which firefighters can tap into a water supply. It is a component of active fire protec-
tion. The user attaches a hose to the fire hydrant, then opens a valve on the hydrant to
provide a powerful flow of water, on the order of 350 kPa (50 pounds per square inch gauge
(psig)) (this pressure varies according to region and depends on various factors including the
size and location of the attached water main). This user can attach this hose to a fire engine,
which can use a powerful pump to boost the water pressure and possibly split it into multiple
streams. One may connect the hose with a threaded connection, instantaneous "quick
connector" or a Storz connector. A user should take care not to open or close a fire hydrant
too quickly, as this can cause a water hammer, which can damage nearby pipes and equip-
ment. The water inside a charged hose line causes it to be very heavy and high water pres-
sure causes it to be stiff and unable to make a tight turn while pressurized. When a fire
hydrant is unobstructed, this is not a problem, as there is enough room to adequately
position the hose.

Fire Hose Cabinet and Reel

Details...
A Fire Hose Cabinet installation is one of the first to be used in case of a fire,
it can fail if the equipment is deteriorated or not accessible.
These digressions can be brought about by regular operation of the site, it
is therefore absolutely necessary to conduct the annual Fire Hose Cabinet
inspection in order to allow the operator to get an overview of the condi-
tion of protection of his establishment.

Specifications
Body Material: Galvanized Steel Sheet
Surface Treatment: Color Coated
Color: Red
14
Product Outline
Hose Pipe and Reel

Specifications
Product name: fire hose pipe
Diameters: 1.5~2.5inch
Usage: Firefighting system
Fire Hose Length: 30m or others
Accessory: With Alu/Brass Coupling
Working pressure: 8~21bar
Test pressure: 16~42bar
Burst pressure: 24~63bar
Lining: PVC
Application: Emergency Rescue

Sprinkler Head

Specifications
Type: Brass Fire Sprinkler
Material: Brass, Chrome, Glass bulb
Glass Bulk Color: Orange, Red, Yellow,
Green, Blue, Purple
Nominal Diameter: DN15, DN20, DN150, DN200
Connecting Thread: R1/2 or R3/4
Temperature Rating: 57,68,79,93,141,181
Bulb: 3mm/5mm
Flow rate: 80~115
Certificate: CCC and ISO

15