0% found this document useful (0 votes)
17 views

Corbel 4

1. This document analyzes the capacity of anchors under tension loading according to ACI 318-11 Appendix D. It evaluates the strength of both steel anchors and concrete breakout strength. 2. It determines the steel capacity of 2 bolts is 77,513 N, which exceeds the required tensile force. The factored steel capacity is over 58,000 N for a single anchor and over 116,000 N for the anchor group. 3. It also calculates the concrete breakout capacity of the single and group anchors under tension. The factored breakout capacity is over 88,000 N for a single anchor and over 116,000 N for the group anchor, meeting the strength requirements.

Uploaded by

Aek Jan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

Corbel 4

1. This document analyzes the capacity of anchors under tension loading according to ACI 318-11 Appendix D. It evaluates the strength of both steel anchors and concrete breakout strength. 2. It determines the steel capacity of 2 bolts is 77,513 N, which exceeds the required tensile force. The factored steel capacity is over 58,000 N for a single anchor and over 116,000 N for the anchor group. 3. It also calculates the concrete breakout capacity of the single and group anchors under tension. The factored breakout capacity is over 88,000 N for a single anchor and over 116,000 N for the group anchor, meeting the strength requirements.

Uploaded by

Aek Jan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTE; CALC ARE PERFORMED IN ACCORDANCE WITH ACI.318-11 APPENDIX D .

Nn
1.5hef 1.5hef
1.Basic design parameter
Nu = 25712 N <--( factored load )
Vu = 61803 N <-- ( factored load ) hef

anchor governed by strength of ductile steel


Bolt type = 1 <= for ductile = 1, for brittle = 2
 factor condition = 0.75 for tension
 factor condition = 0.65 for shear breakout cone for tension

anchor governed by concrete breakout,side face blowout,pullout, pryout strength.


 factor condition =  for tension
 factor condition = 0.75 for shear
Bolt type = 1 <= for stud = 1, for head bolt = 2 , hook = 3
Provide Grout = 2 <= for used grout pads = 1, no grout = 2
Condition = 2 <= for used crack conc = 1, uncrack conc = 2

2.Steel capacity of anchor under tension loading.


Nsa = n Ase futa Fu Fy

n = 2 bolts number of anchor in a group Grade 4.8(ASTM- A3 420 250

bolt  = 16 mm Diameter of bolts or studs Grade 4.6 (JIS G310 400 245 ( section for 2- Top of rebar )
number of threads = 11 Bolt Grade 5.8 520 420

e = 0 mm eccentricity ( ** in case of no eccentric = 0) Grade 8.8 800 640 >96mm OK >96mm OK >96mm OK

Nu,max,1 stud = 12856.0 N <= Maximum tensile force of single bolt = Nu/n + Nx e/[2xS] Grade 8.8 (A325 ) 830 225 225.0 225
Ase = 149.06 mm ^2 Effective cross area of anchor Grade 10.9(A490) 1040 940

futa = 520 Mpa <= < min( 860,1.9fya) OK


fy = 390.0 Mpa
Nsa = 77513 N 248 >96mm OK

Nsa = 58134.6 N >12856.005 OK in single


Nsa = 116269.2 N >25712.01 OK in group

3.Concrete breakout capacity of anchor under tension loading ( sec. D.5.2 ) 552 >96mm OK
Ncb = ANc/ANco Ψed,N Ψc,N Ψcp,N Nb single anchor edge
Ncbg = ANc/ANco Ψec,N, Ψed,N Ψc,N Ψcp,N Nb groups anchor ( unit:mm)

n= 2 Nos the numbers of tension anchor in group.


hef = 140 mm <= this value should not be more 700mm
hef ' = 140 mm <= Effective anchor embedment depth
Ca,min = 210 mm <= from figure 800 mm.
Ca, max = 210 mm <= from figure <1.5hef, OK

hef '
Smax = 200 mm <= maximum spacing between bolts<3 hef' OK
fc ' = 20.0 Mpa <= Concrte compressive strength e
In case = 2 <= if cast-in bolt = 1 , if post-installed = 2 Nu
In case = 4 <= if under cut anchor=1, Torque-controlled expansion anchor=2 or Displacement-control anchor expansion anch=3 , Adhesive anchors = 4
Anco = 176400 mm 2 Projected area of failure surface of a single anchor remote from c a,min of 1.5hef or greater
Anc = 270900 mm 2 <= Projected concrete failure area of group anchor by tension force. ( Plan of bolt group appiled tensile force)
Anc = 205800 mm 2 <= Projected concrete failure area of single anchor by tension force.
 ed,N = 1.000 <= if cmin > =1.5hef = 1 , if cmin < 1.5 hef = 0.7+0.3x[camin]/[1.5hef]
 c,N = 1.4 <= for crack concrete(all case = 1), for uncrack section ( insitu = 1.25, post-installed anchors = 1.4)
Cac = 280.0 the critical edge distance shall not be taken less than
 ec,N = 1.00 <= Modifiled for anchorage group eccentrically in tension.
 cp,N = 0.75 <= Modifiled factor for post -installed anchor
kc = 13 <= Cracked conc (cast-in =10, post-install by used product test = 10(max), post install not used product test = 7 ) , Uncrack ( cast-in=10, and post-install = 13(max), )
Nb = 96305 N <= Basic concrete breakout strength cast in anchor = 10 √fc' hef1.5 , for post-installed = 7 √fc' hef1.5 , if 280 mm<= hef<=635 mm = 3.9 √fc' hef1.5
Ncb = 88480.5 N >12856.005 OK in single
Ncbg = 116469.3 N >25712.01 OK in group

4.Bond strength of adhesive anchor in tension loading ( D.5.5 ) <-- If Cast- in anchor this case is neglect 179.8 248
Na = ANa/ANao Ψed,Na Ψcp,Na Nba single adhesive anchor
Nag = ANa/ANao Ψec,Na,Ψed,Na Ψcp,Na Nba group adhesive anchors 179.8 552

179.8 179.8
condition = 2 <= design include sustained tension loading =1, no sustained loading = 2 Single through anchor 225 225 225.0
τuncr = 12.5 Mpa <= The characteristic bond stress. Group of adhesive anchors located
2
τuncr = 12.50 N/mm <= The characteristic bond stress from table ( uncrack for find CNa)
CNa = 179.8 mm <= projected distance from center of an achor shaft on one side of the anchor near corner through anchor
2
ANao = 129293 mm Projected influence area of single adhesive anchor in tension if not limited by edge distance
2
ANa = 210197 mm <= Projected influence area of groups adhesive anchorage for calculation of bond strength in tension.
2
ANa = 145550 mm <= Projected influence area of single adhesive anchorage for calculation of bond strength in tension.
 ed,Na = 1.000 <= if Ca,min > =CNa = 1 , if Ca,min < CNa = 0.7+0.3xCa,min/ CNa
 ec,Na = 1.000 <= Modifiled for anchorage group eccentrically in tension.
 cp,Na = 0.75 <= if Ca,min > =Cac = 1 , if Ca,min < Cac = Ca,min/ Cac
λa = 1.00 <= Modifition factored Hilti producted charactistic bonding strength ( unit; MPa)

Nb = 87965 N <= Basic concrete breakout strength N b = λ a τ(cr  or uncr) π d a h ef TYPE Pullout strength 10 12 16 20 Remark

Na = 55701.8 N >12856.01 OK in single RE-500+ rebar τ cr 9.62 9.62 9.82 9.92
Nag = 80442 N >25712.01 OK in group (temp range A) τ uncr 12.6 12.6 11.5 12.1 Dry Conc and

RE-500+ rebar τ cr 6.65 6.65 6.75 6.85 water saturated


(temp range B) τ uncr 8.62 8.62 8.52 8.41
use hammer drill
Remark
** Temp range A is short term temp =43 C, long term = 26 C
** Temp range B is short term temp = 72 C, long term = 43 C

4. Concrete Pullout capacity. <-- (if use adhesive anchorage This case is neglect )