Corbel 4
Corbel 4
Nn
1.5hef 1.5hef
1.Basic design parameter
Nu = 25712 N <--( factored load )
Vu = 61803 N <-- ( factored load ) hef
bolt = 16 mm Diameter of bolts or studs Grade 4.6 (JIS G310 400 245 ( section for 2- Top of rebar )
number of threads = 11 Bolt Grade 5.8 520 420
e = 0 mm eccentricity ( ** in case of no eccentric = 0) Grade 8.8 800 640 >96mm OK >96mm OK >96mm OK
Nu,max,1 stud = 12856.0 N <= Maximum tensile force of single bolt = Nu/n + Nx e/[2xS] Grade 8.8 (A325 ) 830 225 225.0 225
Ase = 149.06 mm ^2 Effective cross area of anchor Grade 10.9(A490) 1040 940
3.Concrete breakout capacity of anchor under tension loading ( sec. D.5.2 ) 552 >96mm OK
Ncb = ANc/ANco Ψed,N Ψc,N Ψcp,N Nb single anchor edge
Ncbg = ANc/ANco Ψec,N, Ψed,N Ψc,N Ψcp,N Nb groups anchor ( unit:mm)
hef '
Smax = 200 mm <= maximum spacing between bolts<3 hef' OK
fc ' = 20.0 Mpa <= Concrte compressive strength e
In case = 2 <= if cast-in bolt = 1 , if post-installed = 2 Nu
In case = 4 <= if under cut anchor=1, Torque-controlled expansion anchor=2 or Displacement-control anchor expansion anch=3 , Adhesive anchors = 4
Anco = 176400 mm 2 Projected area of failure surface of a single anchor remote from c a,min of 1.5hef or greater
Anc = 270900 mm 2 <= Projected concrete failure area of group anchor by tension force. ( Plan of bolt group appiled tensile force)
Anc = 205800 mm 2 <= Projected concrete failure area of single anchor by tension force.
ed,N = 1.000 <= if cmin > =1.5hef = 1 , if cmin < 1.5 hef = 0.7+0.3x[camin]/[1.5hef]
c,N = 1.4 <= for crack concrete(all case = 1), for uncrack section ( insitu = 1.25, post-installed anchors = 1.4)
Cac = 280.0 the critical edge distance shall not be taken less than
ec,N = 1.00 <= Modifiled for anchorage group eccentrically in tension.
cp,N = 0.75 <= Modifiled factor for post -installed anchor
kc = 13 <= Cracked conc (cast-in =10, post-install by used product test = 10(max), post install not used product test = 7 ) , Uncrack ( cast-in=10, and post-install = 13(max), )
Nb = 96305 N <= Basic concrete breakout strength cast in anchor = 10 √fc' hef1.5 , for post-installed = 7 √fc' hef1.5 , if 280 mm<= hef<=635 mm = 3.9 √fc' hef1.5
Ncb = 88480.5 N >12856.005 OK in single
Ncbg = 116469.3 N >25712.01 OK in group
4.Bond strength of adhesive anchor in tension loading ( D.5.5 ) <-- If Cast- in anchor this case is neglect 179.8 248
Na = ANa/ANao Ψed,Na Ψcp,Na Nba single adhesive anchor
Nag = ANa/ANao Ψec,Na,Ψed,Na Ψcp,Na Nba group adhesive anchors 179.8 552
179.8 179.8
condition = 2 <= design include sustained tension loading =1, no sustained loading = 2 Single through anchor 225 225 225.0
τuncr = 12.5 Mpa <= The characteristic bond stress. Group of adhesive anchors located
2
τuncr = 12.50 N/mm <= The characteristic bond stress from table ( uncrack for find CNa)
CNa = 179.8 mm <= projected distance from center of an achor shaft on one side of the anchor near corner through anchor
2
ANao = 129293 mm Projected influence area of single adhesive anchor in tension if not limited by edge distance
2
ANa = 210197 mm <= Projected influence area of groups adhesive anchorage for calculation of bond strength in tension.
2
ANa = 145550 mm <= Projected influence area of single adhesive anchorage for calculation of bond strength in tension.
ed,Na = 1.000 <= if Ca,min > =CNa = 1 , if Ca,min < CNa = 0.7+0.3xCa,min/ CNa
ec,Na = 1.000 <= Modifiled for anchorage group eccentrically in tension.
cp,Na = 0.75 <= if Ca,min > =Cac = 1 , if Ca,min < Cac = Ca,min/ Cac
λa = 1.00 <= Modifition factored Hilti producted charactistic bonding strength ( unit; MPa)
Nb = 87965 N <= Basic concrete breakout strength N b = λ a τ(cr or uncr) π d a h ef TYPE Pullout strength 10 12 16 20 Remark
Na = 55701.8 N >12856.01 OK in single RE-500+ rebar τ cr 9.62 9.62 9.82 9.92
Nag = 80442 N >25712.01 OK in group (temp range A) τ uncr 12.6 12.6 11.5 12.1 Dry Conc and
4. Concrete Pullout capacity. <-- (if use adhesive anchorage This case is neglect )