GPP-100 Cartridge Based Protein Analyser SMCS Es UNL) Be Nolte un ean oer Ani) + 2.D bar code for reading the assay type automatically + Based on single cartridge containing all reagents to run a sample. + No consumable needed extra + Pack size of 20 tests/pack + Inbuilt calibration curve provided by manufacturer + Results within 3-8 minutes + Easy to use with single step procedure + Memory storage of 1 lac results + Built in thermal printer, Based on touch screen * * 7 a LL www.immunoshop.com Wide menu for your lab needs GPP 100 TEST menu irra Pat TiC FR- CRP lato cy ata One Step Only Specifications Measuring Time 3 to 8 minutes ees CE PeytSh Disease oy GS9 fe ca ica Pee eee Dec TN Tc re foc) fer) Vr wn ED lord MORE ASSAYS ARE TO BE EXPECTED er the cartridge, then just COCs cats) Color touch screen oka 3 pl to 300 pL. fe Built-in thermal printer eco 20 T/Kit Pea 7.1kg DUG Bice ai) UP to 100,000 test results cg 404 mm*161 mm*397 mm WHTSo Basics wwwimmunoshop.com FA 160 POCT Analyzer Fluorescent Rapid Card Reader Fluorescent label like lanthanide based rapid card tests for Higher sensitivity and stability 6 incubation channels for incubating cards Lot Calibration based on RFID Cards Battery back up thus portable and can be used in any setup 25 tests/package Superior technology for ACCURATE RESULTS Lifotronic FA-160 is FIA principle based POCT rapid card reader. The instrument offers rapid card testing platform with quantitative result analysis. The instrument does not use conventional fluorescent principle but is based on TRFIA principle-TRFIA is similar to fluorometric assays but differs in its use of specific molecules like lanthanides which has unusual property of emittng over long periods of time after excitation( increased Stoke's Shift) whereas in fluresceinbased assays the emission starts within few seconds of being excited ( reduced Stoke's shift), Thus avoiding the elevated background signals as seen in standard fluorescent based assays and in turn offering better sensitivity. WICEB Basics www.immunoshop.com TRFIA based rapid card tests are similar to fluorometric assays but uses lanthanides labels offering many advantages. + Higher sensitivity and stability due to low background noise + Quantitative results for analytes with preset cut-off values. + Result traceability with FIA (fluoroimmunoassay) card reader FA 160 Menu COMPREHENSIVE MENU COMPLETE POCT DIAGNOSTIC NEEDS CRP hs-CRP H-FABP NT-proBNP. Malaria Cystatin C Specifications Model: Methodology: Throughput: SampleType: Storage: Connection: Operation Condition: Lithium Battery: FA-160 Immunofluorescence Assay 15-20 Samples Whole Blood, Serum, Plasma 10,000 Test Results USB, RS -232, LIS Compatible Temperature 10~30°C Humidity < 80% 5200 mAh lS Basics wwwimmunoshop.com vil [Sb Basics ae ia) WBC, Lymph#, Midi#f, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, ROW-SD, PLT, MPV, POW, PCT, P-LCR,P-LCC 3 histograms for WBC, RBC and PLT Uses improved technology which reduces the need for cleanser and rinse. The instrument works with 2 reagents only maintaining lower consumption of reagents H3Pro is having small footprint thus offering space saving and thus can be setup in any lab The 10.4 inch TFT touch screen offers large screen for easy operation & all results on single screen. Built in thermal printer for result print outs, For warning in case of abnormal cell results Whole blood mode, Prediluted mode or capillary mode High precision with CV The aperture is made up of ruby thus no need of frequent replacement. The new internal structural design separates electronic components from the fluidic system, thus easy maintenance. Reagent sensor offered. Flags for any clog happening. Also offer NLR and PLR parameters calculation www.immunoshop.com Automated 3-part Hematology Analyzer Technical Specifications Impedance method for WBC, RBC and PLT counting Principles Cyanide free reagent for hemoglobin test 2 parameters: WBC, Lymph#, Midi, Grand, Lymph, Mid%, Gran, RBCHGB, HCT, MCV, MCH, Parameters MCHC, ROW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms for WBC, RBC and PLT Earnie Prediluted mode 20uL Whole blood mode 9 ul Parameter Linearity Range Precision (CV%) Carryover weC(10"/L) 0-300 <3.5%(4.0-6.9) <0.5% <2.0%(7.0-15.0) Periorrance RBC(10"/L) 0-8.00 <1.5%(3.5-6.5) <0.5% HeBle/L) 0-280 +<1.59%(100-180) <0.5% MCV(fL) <1.096(70.0-110) <0.5% PLT(10°/L 0-4000 <5.0%(100-149) <1,0% <4.0%(150-500) Reagent DILUENT, LYSE, PROBE CLEANSER Throughput 70 samples per hour Display 10.4 inch TFT Touch Screen Data Storage Capacity Up to 500,000 results including numeric and graphical information ‘Communication LAN Port supports HL7 protocol Support bi-directional LIS. Interface 4 USB ports (for external printer, software upgrade, barcode reader, external WIFI adapter, keyboard and mouse), LAN port (1) Printout Thermal recorder, 50 mm wide paper, various printouts formats External printer optional Power Requirement Temperature: 10°C~40°C, Humidity: 10%~90%, Air pressure: 70kPa~106kPa Power Requirement _(100V-240V) <300VA, S0H2/60Hz Dimension and Weight Dimension: Depth (410 mm) x width (300 mm) x height (400 mm) Weight: 20Kg wWhCZSBasies www.immunoshop.com aid HBPro HPLC based Fully Automated HbA1c analyser Gold Standard Methodology Dual Wavelength Detection Minimize Operation Steps Percise , Reliable and Accurate Results HPLC Technology-Gold Standard Methodology : © NGSP and IFCC Certified © HbAlc Results within 130 seconds ‘© 5 samples loading capacity, suitable for medium to small labs Dual Wavelength Detection -To Avoid Interference ‘© Toavoid the reagent peak interference © More antiinterference abilities the factor interference to the peak can be easily counteracted © Toeliminate the nonspecific absorption of hemoglobin ‘Minimize Operation Steps No Samole preparation # Fully automated system cleaning after test # Extemal barcode scanner for sample identification Percise , Reliable and Accurate Results ‘© More Stable Pressure, More Accurate Flow Rate To Reduce Background Absorption and Improve Detection Sensitivity ToImprove the separation effect of Column and Prolong its lifetime Outstanding Technology LifeDx H8Pro, is a compact, automated HPLC analyzer that uses ion exchange liquid chromatography for {quantitative determination of the glycated haemoglobin (HbATA) in human whole blood with processing time of 130 seconds that will expedite the laboratory TAT Compact automated HPLC system Fully automated start-up, maintenance and shutdown + Barcode scanner for sample identification Five samples loading capacity NGSP and IFCC certified ‘The Elements of Hemoglobin 0.5% HBS, HbD, HbC, HbEand ete, Fetal hemaglobin ‘Glyealed Hb from the combination between HbA and glucose and is 60-70% of total HAT Product ofthe combination between HbA and fructose / lactose Gold Standard of Diabetes Diagnose Glycosylated hemoglobin (HbAIC) is widely recognized as a Gold Standard to monitor diabetes, which can indicate the average plasma glucose concentration over 812 weeks HPLC Methodology High-Pressure Liquid Chromatography (HPLC), to separate HbA directly with measuring the absorbance points, continually to forrn chromatogram. Using normal distribution curve fitting auto interpretative algorithm to get precise HbAIc testing result, excluding interference of variant and unstable hemoglobin lke LAIc. Standard Analysis Mode will report HbATa, HDA, HF, HbATC, HbAD peak areas and percentage. The result also includes IFCC, NGSP value for diverse client needs, Precise and Reliable -To serve you consistently ‘Inter measuring C¥<1.5% and Intra measuring CV's <39% ‘© Superior quality chromatographic resolution to eliminate interferences, Other Features © Reagent kit: Eluent A, Eluent B, Hemolysin L,Calibrator, QC material Test mode: HbAc and E/D/S/C variants detected in single mode © Precision -C¥v<1 5% + Test speed 130 secs /test «Different sample types- Venous blood ,finger peripheral blood, Lyophilized Whole Blood ,10ul (whole blood ) 400ul (diluted blood ) + Double detection-with photometer of 415nm+500nm Detector Larger display-10.1 “TET” Tue color LCD Touch screen © Result storage 4000 sample results Technical Specification: Methodology High-Performance Liquid Chromatography HPLC) Test Modes HbAic and E/D/S/C variants detected in single mode Test ange aa Precision Weis Test Speed TBO Secs Test SampleType ‘Venous Blood Finger PeipheralBloedLyophilzed Whole Blood 10ul whole blood), 400u (ilutedblood) ‘Auto Sample Station | 5 Postions/Rack Photometer “1 5nm + 500hm Detector Fite > 4007 Display 10.1 TFT True Calour LCD Touch Seen Software Linx Sohware with self clagnoss to monitor and detec system evors Reagent kt ent, Elert& Hemolsin , Calibrator OC Material Infermation Inout | Scanner to touch Keypad Storage 4900 Same Results Connection USB, LAN, LS Compatible Printer Trermal Printer Operation Temperature 10~300C (50 860") Humility <0 Power "AC 100-2407 S0/6OHE 120K Dimension -450men (Lx 360mm (WV) x540me Weioht BK, check/ SinglePlate Shaker HI Smallest footprint - saves valuable bench space like no other Product dimensions match Microplate size (127 x 85 mm only) Replaceable clamps to hold different types of Microplates (comes with 2 sets of interchangeable clamps) Tool free, easy and time saving clamp change procedure I Greater Speed setting range (Select speed ranging from 200 rpm to 1500 rpm) @ Variable Timer model with time setting for upto 180 mins nut Microcentrifuge This feature rich micro centrifuge is specially designed to suit your need for microfiltration and quick spin downs = 8 Place closed rotor ensures better airflow, greater efficiency with quiet operation and low heat generation Electronic brake for immediate stop on lid opening for user safety = Universal power supply with SMPS for high efficiency and power savings m Save time by doing quick runs by simply closing and opening the lid when the unit is switched ON = Digital display of speed = Small footprint saves valuable bench space ™ Microprocessor controlled enables digital variable speed and time setting with last run memory function (MO8VT) ™ User enabled digital calibration function (MO8VT) WiIlSeBasies www.immunoshop.com Microplate ELISA Reader (RT -6900) +7" Color LCD Touch Screen with Built-in Printer. + 8- Channel Optical Fiber System, 5 Seconds' Reading for whole Plate + Support Single/Dual Wavelength Measurment. + Plate Shaking Function, Speed and Frequency Adjustable + Up to 100 Programs and 10,000 Sample Results storage. + Multi- assay enables upto 12 different assays in one plate + Auto Self - Check When Power on. + Random positive and negative control setting + Save data automatically in case of power outage. «Lamp saving function + Improved user experience with powerful software + Effective data and result interpretation WITS Basics ‘www.immunoshop.com ELISA READER (RT-6900) Technical Specification Absorbance Range Resolution Light Source Optical System Wavelengths Wavelength Accurancy Band Width Calculation Method Methodologies Type of Microplate Reading Speed Shanking Plate Memory Printer Power Supply Dimension(mm) Weight WiICSEBSsies 0-4.000 Abs 0.001 Abs (displayed), 0.0001 Abs (Calculated) Halogen lamp 6V/19W 8-channel optical fiber system 4 Standard filters 405nm, 450nm, 490nm, 630nm, 3 more filter optional +2nm 8+ 2nm ABS, Cut-off, Multi-percent, Percent log, Linear Exponential, Index, 4PL, Regression, etc End-point, fixed-time, Kinetic Standard with 96-well or other kind of microplate and strip. 5 Seconds for 96-well plate(Single wavelength) Shaking time and speed adjustable Up to 100 Programs and 10,000 sample results storage Internal thermal printer, external printer optimal USB port, LAN, SD card slot, RS-232 AC100-240V,50Hz/60Hz 425(L)x310(W)x215(H) 12kg wwwimmunoshop.com MICROPLATE ELISA Washer (RT-3100) + User friendly operation system with large LCD display + Washes U, V and flat bottom strips and plates + 12-way or 8-way manifold, automatic and manual positioning + Large memory, upto 100 wash protocols can be programmed + Multi-channel, 1 upto 3 for wash, 1 for rinse and 1 for waste + Plate shaking function, time and speed are adjustable + Two 96- well plate incubation positions ( optional) + Liquid level detection and alert function + Easy maintenance MICROPLATE WASHER (RT-3100) Technical Specification 96-48 well ato stp ul 10-000 byte Maxum 9 ee, 1012 strips programmable o-24hous 0-24 hours Largetco cee rc Memory 9 mashing protects as202 2 11002200, 50H 13Kg «450mm x380mm x 190mm, 25°C 30°C, 37°C llITSB Basics www.immunoshop.com Motic IFA Microscope = Adjustable fluorescence intensity = Auto on/off mode prolongs slide life and promotes accurate Diagnosis = Powerful battery allows long time operation ™ Concealed accessories for perfect fluorescence effect impressive interlock feature protects users from emergent LED light from leaking = Dual microscope for immunofluorescence and bright field = Available with and without camera option = Offering detection with calcofluor white dye used for fungal studies WlTSb Basics www.immunoshop.com Specifications Optical System Observation System Interpupillary distance (MM) Eyepieces Eyepieces diopter afjustment Trinocular light split Nosepiece Objectives EC-Plan Acromates Objectives mounting thread RMS standard (W 4/5"x1/36") Built-in Coarial mechanical stage with sample holder Stage Size(mm) Travel range(mm) Upper limit stop Condenser Focus mechanism Fine focus precision (mm) Zaxis movement (mm) Filter holder with fixing cap lumination Halogen /LED interchangeability Illumination position Transformer Power Supply Filters Dimensions (mm) Weight(ka) Monsees Brightfield WhlCSb'Basies BA2IOE STANDARD CON' JRATION cas Siedentopf 300 55-75 NAWE 10/20 415 dpi 20/30 reversed Quadrapule 4x/0.10; 10x0.25; 40x0.65; 100x1.25 oil Yes Yes 150x130 80x30 Rackless Preset adjustable Abbe Focusable type N. A 125; with slot for phase DF Coaxial tension adjustment 2 20 Yes 30W halogen Yes Built-in Built-in 110-240V (CE) Blue 360x220x398 72 Yes wwwimmunoshop.com Te checl ANTI CCP (CYCLIC CITRULLINATED PEPTIDES) RAPID CARD TEST Rapid card test for semi quantitative determina tion of anti CCP (Cyclic Citrullinated Peptide) Anti- bodies in human serum or plasma samples cREEH/ Anti COP Antibody = Reference band intensity card provided for semi quantitative detection OO -« Oo = High specificity predictive and prognostic marker o-* before clinical symptoms arise roo = Results within 15 minutes . a o = Inbuilt procedural control ae = Room temperature storage = Convenient pack size of 20 tests/package Troponin | Rapid Card Test “Trop lisa cardiac marker of choice in detection of myocardial infractions. + Sample that can be used with Immucheck Troponin | rapid card test are whole blood, serum or plasma, thus can be used as point of care test. + Analytical sensitivity is 0.5 ng/ml + Sensitivity: 98.59% + Specificity: 98.4% + Results within 10 minutes + Inbuilt procedural control. «Pack size of 20 tests wWllTSo'Basies www.immunoshop.com Chikungunya IgG/IgM check Rapid Card Test immu, + Chikungunya IgM Ab detection is important for early detection in acute phase thereby preventing further transmission of the virus + Immucheck Chikungunya kit is also able to detect IgG antibodies + Utilizes recombinant antigens derived from viral structure protein. + Helps to differentiate from other febrile illnesses with similar symptoms like dengue. + Sensitivity: 90.3% + Specificity:100% + Results within 15 minutes. + Inbuilt procedural control + Pack size of 20 tests “4. Typhoid IgG/IgM Rapid Card Test + Samples that can be used include serum and plasma sample. « Can detect both IgG & IgM separately and simultaneously, thus indicating status of acute infection, convalescence or previous exposure * Instant diagnosis enabling early detection as against Widal test which takes many hours to get results. + Results within 15 minutes. + Sensitivity & specificity in case of IgM: Sensitivity: 100%, Specificity: 99.3% + Sensitivity & specificity in case of IgG Sensitivity: 97%, Specificity: 99.3% «Pack size of 20 and 50 tests www.immunoshop.com wWilTSb Basics Malaria Pf/Pv ce Rapid Card Test + Immucheck Malaria Pf/Pv kit utilizes monoclonal Abs to the P. falciparum specific histidine rich protein-2 (HRP-2) & P. vivax specific lactate dehydrogenase (pLDH). Thus helping in detection and differentiation of malaria by P. falciparum and P.vivax. + Sensitivity: It can detect a minimum of 100 parasites/ul of whole blood. * Sample that can be used is whole blood thus it can be used as a finger prick test at point of care. + Visible results within 20 minutes. + Inbuilt procedural control + Listed in WHO «Pack size of 20 and 50 tests Dengue NS1 Ag Rapid Card Test + Immucheck Dengue plus is a one step immunochromatographic assay designed to detect Dengue NS1 antigens in serum or plasma sample. * Our kit detects all the 4 dengue serotypes (DEN1, DEN2, DEN3 and DENA) ensures the detection of Dengue at any stage of detection. + Sensitivity - NS1 95.8%. + Visible results in 15 minutes + No cross reaction with other flaviviruses «Pack size of 20 tests wwwimmunoshop.com wilCEB Basics Dengue Plus (NS1 Ag/IgG/IgM fetal : Rapid Card Test + Immucheck Dengue plus is a one step immunochromatographic assay designed to detect both dengue NS1 antigens and IgG/ IgM antibodies in serum or plasma sample. + Our kit detects all the 4 dengue serotypes (DEN1, DEN2, DEN3 and DEN4) ensures the detection of Dengue at any stage of detection. + Sensitivity — IgM 83.3%, IgG >99.9%, NS1 95.8%. fi + Visible results in 15 minutes + No cross reaction with other flaviviruses + Pack size of 10 tests Rapid detection of Dengue at any stage of Infection cus cu ea NS1iIgGiigM Dent acta tans gn wt SC) For acute phase samples (day 1-5) 7 Not avaiable os Wwe Aga wt O12 34567 829 Day Dengue - The clinical course oT234567 828 Dy “Days ofliness 1244558789 0 IgG/igM “Temperature ? For convalescence phase samples(day 3-5) Potential cinial issues | gration Not avatabe a ful vetoes + Laboratory changes ei ee “platelets hamatctt " + Serology and virology sraenia += Phase of ines |/ vt Febrile Critical Recovery OT23 4557 850 Day olTS6 Basics www.immunoshop.com Filariasis lgG/IgM ec" Rapid card test + Offers detection and differentiation of IgG and IgM antibodies against Filariasis parasites (W. Bancrofti and B. Malayi)- The most common infections prevalent in India. Thus differentiating acute and chronic infection. + The tests can be performed with fingerstick Whole blood/Serum or plasma thus can be used in any setup. + Inbuilt procedural control + Results within 15 minutes. +Can be stored at RT (2-30 deg C) thus cold storage not required. + Excellent performace - For IgG antibody detection Sensitivity: 92.5%, Specificity: 98.4% + For IgM antibody detection Sensitivity: 96.9% Specificity: 98.8% + Sample volume required — 40 microl a Leishmania IgG/IgM Rapid card test + Offers detection and differentiation of IgG and IgM antibodies against Leishmania donovani- The most common infections prevalent in India. Thus differentiating acute and chronic infection. + The tests can be performed with fingerstick Whole blood/Serum or plasma thus can be used in any setup. + Can be stored at RT (4-26 deg C) thus cold storage not required. + Results within 15 minutes. + Inbuilt procedural control. + Excellent performace + For IgG antibody detection Sensitivity: 92.5%, Specificity: 98.4% + For IgM antibody detection Sensitivity: 96.9% and specificity: 98.8% wwwimmunoshop.com wll SSBasies Wantai Rotavirus Ag in stool Rapid card test + Rapid tests for detection of Rotavirus Ag in stool samples. +10 tests kit « Sample collection tubes provided with the kit + Results within 10 minutes. + Sensitivity: 94.85% and Specificity- 98.55% + Ready to use as stool sample collection tubes provided with the kit + Can be stored at RT Wantai HAV IgM Rapid Card Test + Sample- serum/plasma +10 tests kit - Sample dilution tubes provided with the kit + Results within 10 minutes. + Can be stored at RT wlabBasies wwwimmunoshop.com immunoshop . [ab Automation CHECK OUT OUR OTHER PRODUCTS @ MAGLUMI CLIA ANALYSER @ ‘CHORUS IMMUNOASSAY ANALYSER: iru avromaren proven anaursen @ HbA1c WITH VARIANT & 8B THALASSEMIA MODE @ 2 PLATE AND 4 PLATE ELISA PROCESSORS @ a+ Biot processor FULLY AUTOMATED IMMUNOBLOT PROCESSOR AND ANALYSER o 5 PART FULLY AUTOMATED HEMATOLOGY ANALYSER Em immunoshop Ba Speciality Kits ENDOCRINOLOGY aay tes honey IMMUNOFLORESCENCEM LINE IMMUNOASSAY kits Dard} rN rol as vill 26 Basics www.immunoshop.com immunoshop immunoshop . wlll’'36 Basics Promoting better diagnostic tools FIND US ON ADDRESS CONTACT @ wwwimmunoshop.com 312/309, Raheja Arcade, @ [email protected] @ facebook.com/immunoshop Sector-11, CBD, Belapur, @ 9306 306 306 Navi Mumbai- 400614 , @ youtube.com/immunoshop INDIA

You might also like