0% found this document useful (0 votes)
23 views

Nyu 2

This document summarizes MRI scan parameters for a resting state functional MRI scan using a Siemens Magnetom Allegra 3T scanner with a multi-echo EPI sequence and the following parameters: 33 slices, 4mm slice thickness, 2000ms TR, 15ms TE, 90 degree flip angle, 240x192x132mm FOV, and a voxel size of 3.0x3.0x4.0mm. The scan was performed on a child/adult population to study resting state networks with a relative SNR of 1.00.

Uploaded by

zhuyi bi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

Nyu 2

This document summarizes MRI scan parameters for a resting state functional MRI scan using a Siemens Magnetom Allegra 3T scanner with a multi-echo EPI sequence and the following parameters: 33 slices, 4mm slice thickness, 2000ms TR, 15ms TE, 90 degree flip angle, 240x192x132mm FOV, and a voxel size of 3.0x3.0x4.0mm. The scan was performed on a child/adult population to study resting state networks with a relative SNR of 1.00.

Uploaded by

zhuyi bi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SIEMENS MAGNETOM Allegra syngo MR 2004A

\\USER\INVESTIGATORS\Castellanos\Child-AdultR01\Rest_TR2_4mm
Scan Time: 6:00 Voxel size: 3.0×3.0×4.0 [mm] Rel. SNR: 1.00 USER: cbi_seg_epi_gre

Rotation 90 [deg]
Routine
A >> P 240 [mm]
Slice group 1
R >> L 192 [mm]
Slices 33
F >> H 132 [mm]
Dist. factor 0 [%]
Position R6.9 A4.6 H6.9 [mm] Physio
Orientation T > C-23.0 1st Signal/Mode None
Phase enc. dir. R >> L
Sequence
Rotation 90 [deg]
Introduction 0
Phase oversampling 0 [%]
Dimension 2D
FoV read 240 [mm]
Averaging mode Long term
FoV phase 80.0 [%]
Bandwidth 3906 [Hz/Px]
Slice thickness 4 [mm]
Free echo spacing 0
TR 2000 [ms]
Echo spacing 0.32 [ms]
TE 15 [ms] ------------------------------------------------------------------------------------
Averages 1 EPI factor 120
Concatenations 1 RF pulse type Normal
Filter None Gradient mode Fast
Coil elements TR RF spoiling 1
------------------------------------------------------------------------------------
Contrast Image Reconstruction Save Raw
MTC 0 Field Map Mode FMap Off
Magn. preparation None Multi Mode MultiEcho
Flip angle 90 [deg] No. of Echos 1
Reconstruction Magnitude Inner Image Size 16
Fat suppr. Fat sat. No. of Shots 1
Measurements 180 Readout Direction Normal
Pause after meas. 0 [s] Spoil Phase Step 123.0
Multiple series 0 Spoil Grad Amp 1.0
Resolution
Base resolution 80
Phase resolution 100 [%]
Phase partial Fourier Off
Filter 1
Raw filter Off
Filter 2
Large FoV Off
Filter 3
Normalize Off
Filter 4
Elliptical filter Off
Interpolation 0
Geometry
Multi-slice mode Interleaved
Series Interleaved
------------------------------------------------------------------------------------
Special sat. None
System
Save uncombined 0
Scan at current TP 0
Scan region position H
Scan region position 0 [mm]
MSMA S-C-T
Sagittal R >> L
Coronal A >> P
Transversal F >> H
Nova_TR / TR 1
------------------------------------------------------------------------------------
Shim mode Standard
Confirm freq. adjustment 0
Assume Silicone 0
Ref. amplitude [1H] 140.000 [V]
Adjust volume
Position R6.9 A4.6 H6.9 [mm]
Orientation T > C-23.0