100% found this document useful (1 vote)
8K views90 pages

Revised Phed BSR 2023

1. The document is the revised schedule of rates for 2023-2024 issued by the Public Health Engineering Department, Government of Rajasthan. 2. It provides rates for various pipe line works using ductile iron pipes of different diameters, as well as rates for ductile iron specials like tees, bends, and others. 3. The rates are applicable to PHED Rajasthan works and are effective from July 10, 2023.

Uploaded by

RJ Jangid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
8K views90 pages

Revised Phed BSR 2023

1. The document is the revised schedule of rates for 2023-2024 issued by the Public Health Engineering Department, Government of Rajasthan. 2. It provides rates for various pipe line works using ductile iron pipes of different diameters, as well as rates for ductile iron specials like tees, bends, and others. 3. The rates are applicable to PHED Rajasthan works and are effective from July 10, 2023.

Uploaded by

RJ Jangid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 90

PUBLIC HEALTH ENGINEERING DEPARTMENT

Government of Rajasthan

REVISED SCHEDULE OF RATES


YEAR 2023 - 2024

( Effective from 10/07/2023 )

APPLICABLE FOR

PHED RAJASTHAN WORKS

Issued by:-
Chief Engineer (Tech) & TM.
RWSSMB, PHED, Jaipur
PUBLIC HEALTH ENGINEERING DEPARTMENT
Government of Rajasthan

REVISED PHED BSR 2023

CONTENTS
Chapter No. Chapter P. No.
1 Pipe Line Works. 1-18
2 Construction and Commissioning of Tube Wells, Open Wells
19-28
and Hand Pumps.
3   RCC Reservoirs. 29-44
4 Earth Work, Road cutting, Repairing & Trenchless Laying. 45-48
5   Pump Sets. 49-54
6 Valves and Appurtenance. 55-66
7 DOL/Star Delta Starter type LT Panels. 67-69
8   Construction of Pump House and Boundary Wall. 70-71
9 Valve Chambers 72-74
10 Solar based water supply schemes. 75-78
11 Instrumentation. 79-81
12 Earth Work & Civil Works related to Storage Tank, Filter
82-84
media work
13 Construction and Commissioning of water treatment plants
85
(WTP)
14 Miscellaneous. 86-87
Chapter 1
Pipe line work
S. No. Description Unit Rate (Rs.)

DI PIPES
1.1 Providing, lowering, laying in trenches, aligning, fixing in position
and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as
per IS:8329-2000 (amended up to date), with internal cement
mortar lining suitable for potable water with rubber ring (EPDM)
joints as per IS: 5382-1985 including all taxes (Central and local),
transportation and freight charges, inspection charges, loading/
unloading charges, including cost of labour and material, specials
(Tee, bend etc.) satisfactory hydraulic testing, disinfection,
commissioning etc. complete as per technical specifications and
direction of Engineer-in-charge. (excluding earth work)
Note : Providing and fixing of all requisite specials as per drawing,
design and layout are inclusive in RM measurement of the item and
shall not be paid separately.

1.1.1 80 mm RMT 1408.00


1.1.2 100 mm RMT 1464.00
1.1.3 150 mm RMT 2082.00
1.1.4 200 mm RMT 2554.00
1.1.5 250 mm RMT 3307.00
1.1.6 300 mm RMT 4221.00
1.1.7 350 mm RMT 5140.00
1.1.8 400 mm RMT 6269.00
1.1.9 450 mm RMT 7398.00
1.1.10 500 mm RMT 8835.00
1.1.11 600 mm RMT 11563.00
1.1.12 700 mm RMT 15544.00
1.1.13 800 mm RMT 19885.00
1.1.14 900 mm RMT 24381.00
1.1.15 1000 mm RMT 29327.00
1.2 Providing, lowering, laying in trenches, aligning, fixing in position
and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as
per IS:8329-2000 (amended up to date), with internal cement
mortar lining suitable for potable water with rubber ring (EPDM)
joints as per IS: 5382-1985 including all taxes (Central and local),
transportation and freight charges, inspection charges, loading/
unloading charges, including cost of labour and material, specials
(Tee, bend etc.) satisfactory hydraulic testing, disinfection,
commissioning etc. complete as per technical specifications and
direction of Engineer-in-charge. (excluding earth work)
Note : Providing and fixing of all requisite specials as per drawing,
design and layout are inclusive in RM measurement of the item and
shall not be paid separately.

1.2.1 100 mm RMT 1670.00


1.2.2 150 mm RMT 2384.00
1.2.3 200 mm RMT 3037.00

PHED REVISED BSR 2023 Pipe line work 1


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.2.4 250 mm RMT 4011.00
1.2.5 300 mm RMT 5095.00
1.2.6 350 mm RMT 6197.00
1.2.7 400 mm RMT 7525.00
1.2.8 450 mm RMT 8983.00
1.2.9 500 mm RMT 10524.00
1.2.10 600 mm RMT 13756.00
1.2.11 700 mm RMT 17577.00
1.2.12 800 mm RMT 21520.00
1.2.13 900 mm RMT 26178.00
1.2.14 1000 mm RMT 31642.00
1.2.15 1100 mm RMT 37893.00
1.2.16 1200 mm RMT 44031.00
1.3 Providing, lowering, laying, aligning, fixing in position and jointing
at all level/ depths DI standard specials with rubber ring
(EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-
2000 or as amended up to date, such as tees, bends, tapers, caps
etc. within trenches in DI pipe line complete including all material,
labour, taxes, testing and commissioning along with pipe line as
per technical specifications and direction of Engineer-in-charge
(excluding earth work).

1.3.1 All End Socketed


1.3.1.1 Up to 300 mm Diameter Kg 145.00
1.3.1.2 Above 300mm and up to 600 mm diameter Kg 161.00
1.3.1.3 Above 600 mm diameter Kg 207.00
1.3.2 All End Flanged
1.3.2.1 Up to 300 mm Diameter Kg 158.00
1.3.2.2 Above 300mm and up to 600 mm diameter Kg 179.00
1.3.2.3 Above 600 mm diameter Kg 235.00
1.3.3 Single Flange/ MJ Collar
1.3.3.1 Up to 300 mm Diameter Kg 151.00
1.3.3.2 Above 300mm and up to 600 mm diameter Kg 168.00
1.3.3.3 Above 600 mm diameter Kg 219.00
1.3.4 Double Flange Pipe (up to 1 mtr. length)
1.3.4.1 Up to 300 mm Diameter Kg 167.00
1.3.4.2 Above 300mm and up to 600 mm diameter Kg 195.00
1.3.4.3 Above 600 mm diameter Kg 246.00

PHED REVISED BSR 2023 Pipe line work 2


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
HDPE PIPES
1.4 Providing, lowering, laying and jointing in trenches,  standard
lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up
to date) with necessary jointing material like mechanical
connectors, i.e. thread/ insert joint/ quick release coupler joint/
compression fitting joint or flanged joint and specials jointing pipe
by electro fusion welding method, including all taxes ,
transportation and freight charges, inspection charges, loading/
unloading charges, stacking of pipes, including cost of labour and
material, specials (Tee, bend etc.), satisfactory hydraulic testing,
disinfection, commissioning etc. complete as per technical
specifications and direction of Engineer-in-charge of following class
and diameter. (excluding earth work) .
Note : Providing and fixing of all requisite specials as per drawing,
design and layout are inclusive in RM measurement of the item and
shall not be paid separately.
Supply may be in coil or straight length in 6 M/12 M.

1.4.1 HDPE PE-80 PN-6


1.4.1.1 63 mm dia RMT 171.00
1.4.1.2 75 mm dia RMT 217.00
1.4.1.3 90 mm dia RMT 306.00
1.4.1.4 110 mm dia RMT 463.00
1.4.2 HDPE PE-100 PN-6
1.4.2.1 63 mm dia RMT 145.00
1.4.2.2 75 mm dia RMT 186.00
1.4.2.3 90 mm dia RMT 264.00
1.4.2.4 110 mm dia RMT 442.00
1.4.3 HDPE PE-80 PN-10
1.4.3.1 90 mm dia RMT 449.00
1.4.3.2 110 mm dia RMT 675.00
1.4.4 HDPE PE-100 PN-10
1.4.4.1 90 mm dia RMT 391.00
1.4.4.2 110 mm dia RMT 582.00
1.5 Providing, lowering, laying and jointing in trenches,  standard
lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up
to date) with necessary jointing material like mechanical
connectors, i.e. thread/ insert joint/ quick release coupler joint/
compression fitting joint or flanged joint and specials jointing pipe
by butt fusion/ electro fusion welding method, including all taxes ,
transportation and freight charges, inspection charges, loading/
unloading charges, stacking of pipes, including cost of labour and
material, specials (Tee, bend etc.), satisfactory hydraulic testing,
disinfection, commissioning etc. complete as per technical
specifications and direction of Engineer-in-charge of following class
and diameter. (excluding earth work).
Note : Providing and fixing of all requisite specials as per drawing,
design and layout are inclusive in RM measurement of the item and
shall not be paid separately.
Supply of pipe shall be in straight length in 6/12 M.

PHED REVISED BSR 2023 Pipe line work 3


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.5.1 HDPE PE-80 PN-6
1.5.1.1 125 mm dia RMT 664.00
1.5.1.2 140 mm dia RMT 827.00
1.5.1.3 160 mm dia RMT 1041.00
1.5.1.4 180 mm dia RMT 1308.00
1.5.1.5 200 mm dia RMT 1567.00
1.5.1.6 225 mm dia RMT 1981.00
1.5.2 HDPE PE-100 PN-6
1.5.2.1 125 mm dia RMT 573.00
1.5.2.2 140 mm dia RMT 713.00
1.5.2.3 160 mm dia RMT 897.00
1.5.2.4 180 mm dia RMT 1125.00
1.5.2.5 200 mm dia RMT 1348.00
1.5.2.6 225 mm dia RMT 1697.00
1.5.3 HDPE PE-80 PN-10
1.5.3.1 125 mm dia RMT 936.00
1.5.3.2 140 mm dia RMT 1172.00
1.5.3.3 160 mm dia RMT 1514.00
1.5.3.4 180 mm dia RMT 1886.00
1.5.3.5 200 mm dia RMT 2313.00
1.5.3.6 225 mm dia RMT 2888.00
1.5.4 HDPE PE-100 PN-10
1.5.4.1 125 mm dia RMT 796.00
1.5.4.2 140 mm dia RMT 996.00
1.5.4.3 160 mm dia RMT 1295.00
1.5.4.4 180 mm dia RMT 1626.00
1.5.4.5 200 mm dia RMT 1969.00
1.5.4.6 225 mm dia RMT 2466.00
MS PIPES
1.6 Manufacturing, supplying ,lowering, laying and jointing in position
to correct line spirally welded SAW/Fabricated MS Pipe having
bevelled end plates / coils, confirming to IS 3589-2001 or its latest
revision/ amendments, for following thickness and inside diameter,
including all taxes (Central and local), transportation and freight
charges, inspection charges, loading/ unloading charges, including
cost of labour and material, specials (Tee, bend etc.), field joints,
satisfactory hydraulic testing, disinfection, commissioning etc.
complete as per technical specifications and direction of Engineer-
in-charge; (excluding earthwork, internal lining and outer coating).
Note : Providing and fixing of all requisite specials as per drawing,
design and layout are inclusive in RM measurement of the item and
shall not be paid separately.

1.6.1 Outer dia of pipe 219.1 mm and thickness


1.6.1.1 2.6 mm RMT 1626.00
1.6.1.2 3.2 mm RMT 1995.00
1.6.1.3 4 mm RMT 2485.00
1.6.1.4 4.5 mm RMT 2789.00
1.6.2 Outer dia of pipe 273 mm and thickness
1.6.2.1 3.6 mm RMT 2801.00
1.6.2.2 4 mm RMT 3107.00

PHED REVISED BSR 2023 Pipe line work 4


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.6.2.3 5 mm RMT 3870.00
1.6.2.4 6.3 mm RMT 4852.00
1.6.3 Outer dia of pipe 323.9 mm and thickness
1.6.3.1 4 mm RMT 3695.00
1.6.3.2 4.5 mm RMT 4151.00
1.6.3.3 5.6 mm RMT 5148.00
1.6.3.4 7.1 mm RMT 6496.00
1.6.4 Outer dia of pipe 355.6 mm and thickness
1.6.4.1 4 mm RMT 4062.00
1.6.4.2 5 mm RMT 5063.00
1.6.4.3 5.6 mm RMT 5660.00
1.6.4.4 7.1 mm RMT 7146.00
1.6.4.5 8 mm RMT 8031.00
1.6.5 Outer dia of pipe 406.4 mm and thickness
1.6.5.1 4 mm RMT 4648.00
1.6.5.2 5 mm RMT 5796.00
1.6.5.3 6.3 mm RMT 7280.00
1.6.5.4 7.1 mm RMT 8188.00
1.6.5.5 8.8 mm RMT 10105.00
1.6.6 Outer dia of pipe 457 mm and thickness
1.6.6.1 4 mm RMT 5233.00
1.6.6.2 5 mm RMT 6527.00
1.6.6.3 6.3 mm RMT 8200.00
1.6.6.4 7.1 mm RMT 9225.00
1.6.6.5 8.8 mm RMT 11391.00
1.6.7 Outer dia of pipe 508 mm and thickness
1.6.7.1 5 mm RMT 7263.00
1.6.7.2 5.6 mm RMT 8125.00
1.6.7.3 6.3 mm RMT 9128.00
1.6.7.4 7.1 mm RMT 10271.00
1.6.7.5 8.8 mm RMT 12687.00
1.6.7.6 10 mm RMT 14382.00
1.6.7.7 11 mm RMT 15789.00
1.6.8 Outer dia of pipe 610 mm and thickness
1.6.8.1 5.8 mm RMT 10121.00
1.6.8.2 6.3 mm RMT 10984.00
1.6.8.3 7.1 mm RMT 12362.00
1.6.8.4 8.8 mm RMT 15279.00
1.6.8.5 10 mm RMT 17328.00
1.6.8.6 11 mm RMT 19029.00
1.6.8.7 12.5 mm RMT 21570.00
1.6.9 Outer dia of pipe 711 mm and thickness
1.6.9.1 6.3 mm RMT 12822.00
1.6.9.2 7.1 mm RMT 14433.00
1.6.9.3 8 mm RMT 16242.00
1.6.9.4 8.8 mm RMT 17846.00
1.6.9.5 10 mm RMT 20245.00
1.6.9.6 11 mm RMT 22237.00
1.6.9.7 12.5 mm RMT 25216.00
1.6.10 Outer dia of pipe 813 mm and thickness
1.6.10.1 7.1 mm RMT 16525.00
1.6.10.2 8 mm RMT 18599.00
1.6.10.3 8.8 mm RMT 20438.00

PHED REVISED BSR 2023 Pipe line work 5


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.6.10.4 10 mm RMT 23190.00
1.6.10.5 11 mm RMT 25478.00
1.6.10.6 12.5 mm RMT 28898.00
1.6.10.7 14.2 mm RMT 32758.00
1.6.11 Outer dia of pipe 914 mm and thickness
1.6.11.1 8 mm RMT 20932.00
1.6.11.2 8.8 mm RMT 23005.00
1.6.11.3 10 mm RMT 26107.00
1.6.11.4 11 mm RMT 28686.00
1.6.11.5 12.5 mm RMT 32544.00
1.6.11.6 12 mm RMT 31260.00
1.6.11.7 14.2 mm RMT 36900.00
1.6.12 Outer dia of pipe 1016 mm and thickness
1.6.12.1 8.8 mm RMT 25597.00
1.6.12.2 10 mm RMT 29053.00
1.6.12.3 11 mm RMT 31927.00
1.6.12.4 12.5 mm RMT 36226.00
1.6.12.5 12 mm RMT 34794.00
1.6.12.6 14.2 mm RMT 41083.00
1.6.12.7 16 mm RMT 46208.00
1.6.13 Outer dia of pipe 1067 mm and thickness
1.6.13.1 8.8 mm RMT 26893.00
1.6.13.2 10 mm RMT 30526.00
1.6.13.3 11 mm RMT 33547.00
1.6.13.4 12.5 mm RMT 38067.00
1.6.13.5 12 mm RMT 36562.00
1.6.13.6 14.2 mm RMT 43175.00
1.6.13.7 16 mm RMT 48564.00
1.6.14 Outer dia of pipe 1118 mm and thickness
1.6.14.1 8.8 mm RMT 28189.00
1.6.14.2 10 mm RMT 31999.00
1.6.14.3 11 mm RMT 35167.00
1.6.14.4 12.5 mm RMT 39908.00
1.6.14.5 12 mm RMT 38329.00
1.6.14.6 14.2 mm RMT 45266.00
1.6.14.7 16 mm RMT 50921.00
1.6.15 Outer dia of pipe 1219 mm and thickness
1.6.15.1 10 mm RMT 34916.00
1.6.15.2 11 mm RMT 38375.00
1.6.15.3 12.5 mm RMT 43554.00
1.6.15.4 14.2 mm RMT 49408.00
1.6.15.5 16 mm RMT 55588.00
1.6.15.6 17.5 mm RMT 60723.00
1.6.16 Outer dia of pipe 1321 mm and thickness RMT
1.6.16.1 12.5 mm 47237.00
1.6.16.2 14.2 mm RMT 53591.00
1.6.16.3 16 mm RMT 60301.00
1.6.16.4 17.5 mm RMT 65878.00
1.6.16.5 20 mm RMT 75145.00
1.6.17 Outer dia of pipe 1422 mm and thickness
1.6.17.1 12.5 mm RMT 50883.00
1.6.17.2 14.2 mm RMT 57733.00
1.6.17.3 16 mm RMT 64968.00

PHED REVISED BSR 2023 Pipe line work 6


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.6.17.4 17.5 mm RMT 70983.00
1.6.17.5 20 mm RMT 80979.00
1.6.18 Outer dia of pipe 1524 mm and thickness
1.6.18.1 14.2 mm RMT 61916.00
1.6.18.2 16 mm RMT 69681.00
1.6.18.3 17.5 mm RMT 76138.00
1.6.18.4 20 mm RMT 86870.00
1.6.18.5 22.2 mm RMT 96285.00
1.6.19 Outer dia of pipe 1626 mm and thickness
1.6.19.1 14.2 mm RMT 66099.00
1.6.19.2 16 mm RMT 74394.00
1.6.19.3 17.5 mm RMT 81293.00
1.6.19.4 20 mm RMT 92762.00
1.6.19.5 22.2 mm RMT 102825.00
1.6.20 Outer dia of pipe 1727 mm and thickness
1.6.20.1 14.2 mm RMT 70241.00
1.6.20.2 16 mm RMT 79061.00
1.6.20.3 17.5 mm RMT 86398.00
1.6.20.4 20 mm RMT 98596.00
1.6.20.5 22.2 mm RMT 109300.00
1.6.21 Outer dia of pipe 1829 mm and thickness
1.6.21.1 14.2 mm RMT 74424.00
1.6.21.2 16 mm RMT 83775.00
1.6.21.3 17.5 mm RMT 91553.00
1.6.21.4 20 mm RMT 104487.00
1.6.21.5 22.2 mm RMT 115840.00
1.6.22 Outer dia of pipe 2032 mm and thickness
1.6.22.1 16 mm RMT 93155.00
1.6.22.2 17.5 mm RMT 101812.00
1.6.22.3 20 mm RMT 116212.00
1.6.22.4 22.2 mm RMT 128855.00
1.6.22.5 25 mm RMT 144904.00
1.6.23 Outer dia of pipe 2235 mm and thickness
1.6.23.1 17.5 mm RMT 112072.00
1.6.23.2 20 mm RMT 127938.00
1.6.23.3 22.2 mm RMT 141870.00
1.6.23.4 25 mm RMT 159561.00
1.6.24 Outer dia of pipe 2540 mm and thickness
1.6.24.1 20 mm RMT 145554.00
1.6.24.2 22.2 mm RMT 161424.00
1.6.24.3 25 mm RMT 181582.00

PHED REVISED BSR 2023 Pipe line work 7


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
Lining and coating on MS pipe
Providing and applying 3LPE (3 Layer Polyethylene) tape coating
conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10
to external surface of M.S. Pipe comprising of a layer of fusion
bonded epoxy (FBE), overlaid with PE adhesive with an outer layer
of high density polyethylene including preparation of surface by
solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN
1.7 ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO SQM 1227.00
8503-2. Minimum thickness of FBE shall be 250 microns including
field joints coating at site complete as per technical specification
and direction of Engineer-in-Charge.
Minimum thickness of coating shall be 3.0 mm on weld seam as well
as remaining surface.

Providing and applying DFBE ( Dual Layer Fusion Bonded Epoxy)


Coating to the external surface of M.S. Pipes conforming to
Canadian Standard CSA Z 245.20-10, consisting of 1st layer of (FBE)
Fusion Bonded Epoxy powder and 2nd layer also of FBE powder as
Abrasion Resistant Overcoat (ARO) including preparation of surface
1.8 by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN SQM 954.00
EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN
ISO 8503-2 including field joints coating at site complete as per
technical specification and direction of Engineer in In charge.
Minimum thickness of coating shall be 600 micron

Providing and applying Spray applied, 100% Solids (Solvent free)


Two Component PU ( Polyurethane) coating as per AWWA C222
Standard on external surface of M.S. Pipe including preparation of
pipe outer surface by solvent cleaning, abrasive blasting to a finish
1.9 of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 SQM 852.00
microns as per DIN EN ISO 8503-2 including field joints coating at
site complete as per technical specification and direction of
Engineer in In charge.
Minimum dry film thickness of coating shall be 1000 micron
Providing and applying with mechanical arrangement 1:3 proportion
cement sand gunite, of following thickness to M.S. Pipe outer
surface under 2.1 Kg per Sqcm to 2.80 Kg per Sqcm. pressure
including removing the loose materials as directed by EIC and
including scrapping the surface with wire brushes, degreasing,
1.10 cleaning by compressed air and providing fixing BRC fabric no.14 as
reinforcement, curing for 21 days, disposing off the rebound
materials with in a lead of 50 mtr including field joints coating at
site complete as per technical specification and direction of
Engineer in In charge.

1.10.1 25 mm thick SQM 545.00


1.10.2 40 mm thick SQM 613.00

PHED REVISED BSR 2023 Pipe line work 8


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
Providing and applying polyolifine tape coating (Cold applied) to
external surface of M.S. Pipe as per AWWA C214-14 Standard
comprising of liquid adhesive, inner layer tape and outer layer tape
including preparation of outer surface of pipe by solvent cleaning,
1.11 abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and SQM 1363.00
surface profile of 50 to 75 microns as per DIN EN ISO 8503-2
including field joints coating at site complete as per technical
specification and direction of Engineer in In charge.

Providing and applying Solvent free, two pack liquid epoxy lining to
internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210
standard including preparation of internal surface of pipe by
cleaning and abrasive blasting including field joints coating at site
1.12 SQM 409.00
complete as per technical specification and direction of Engineer in
In charge. Liquid Epoxy shall be NSF/WARS approved for drinking
water and minimum thickness of lining shall be 406 microns.

Providing and applying 100% Solids, Rigid, DTM Polyurethane lining


to internal surface of M.S. Pipe as per AWWA C222 standard
including preparation of internal surface of pipe by cleaning and
abrasive blasting including field joints coating at site complete as
1.13 SQM 643.00
per technical specification and direction of Engineer in In charge.
Polyurethane Coating shall be NSF/WARS/SS-375 approved for
drinking water and minimum thickness of lining shall be 500
microns.
Providing and making inner cement mortar lining to M.S. Pipes with
mechanical devices in cement mortar 1:1 proportion , including cost
of all materials, labour, special sand required, machinery, power
1.14 generation, all equipments, including carrying out "C" value
performance test of pipeline, including field joints at site complete
as per technical specification and direction of Engineer in In charge.

1.14.1 9 mm thick for pipes up to 700 mm dia SQM 307.00


1.14.2 12 mm thick for pipes above 700 mm dia SQM 341.00
MS Specials
1.15 Providing and fixing of flanged/ plain ended MS Specials made from
MS sheet strips of relevant IS specification of approved thickness by
welding, lowering, laying, aligning, fixing in position at all level/
depths in trenches complete including all taxes, material, labour,
inside lining, outside coating, testing and commissioning along
with pipe line as per technical specifications and direction of
Engineer-in-charge.

1.15.1 MS pipe specials up to 600mm dia (with minimum 5mm Kg 126.00


thickness sheet)
1.15.2 MS pipe specials above 600mm dia(with minimum 6.3mm thickness Kg 134.00
sheet)

PHED REVISED BSR 2023 Pipe line work 9


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
BWSC PIPES
1.16 Providing , lowering, laying and jointing of Bar Wrapped Steel
Cylinder Pipes (BWSC) for overlapping steel welded joint as per
IS:15155-2001(amended up to date) of following class and diameter
including all taxes (Central and local), transportation and freight
charges, inspection charges, loading/ unloading charges, including
cost of labour and material, specials (Tee, bend etc.), field joints,
satisfactory hydraulic testing, disinfection, commissioning etc.
complete as per technical specifications & direction of Engineer-in-
charge (excluding earth work).
Note : Providing and fixing of all requisite specials as per drawing,
design and layout are inclusive in RM measurement of the item and
shall not be paid separately.

Notes
1) Class mentioned below represents the Factory Test pressure of pipe.

2) For external coating at site to the joints, necessary polythene


wrapping for pouring cement slurry shall also be provided with each
pipe.
1.16.1 Factory Test Pressure 12 Kg/ Cm2
1.16.1.1 250mm RMT 3197.00
1.16.1.2 300 mm RMT 3883.00
1.16.1.3 350 mm RMT 4625.00
1.16.1.4 400 mm RMT 5296.00
1.16.1.5 450 mm RMT 6112.00
1.16.1.6 500 mm RMT 6614.00
1.16.1.7 600 mm RMT 8494.00
1.16.1.8 700 mm RMT 10924.00
1.16.1.9 800 mm RMT 13396.00
1.16.1.10 900 mm RMT 16196.00
1.16.1.11 1000 mm RMT 19487.00
1.16.1.12 1100 mm RMT 26823.00
1.16.1.13 1200 mm RMT 29632.00
1.16.1.14 1300 mm RMT 32526.00
1.16.1.15 1400 mm RMT 36266.00
1.16.1.16 1500 mm RMT 43074.00
1.16.1.17 1600 mm RMT 45863.00
1.16.2 Factory Test Pressure 14 Kg/ Cm2
1.16.2.1 250mm RMT 3211.00
1.16.2.2 300 mm RMT 3894.00
1.16.2.3 350 mm RMT 4537.00
1.16.2.4 400 mm RMT 5310.00
1.16.2.5 450 mm RMT 6125.00
1.16.2.6 500 mm RMT 6791.00
1.16.2.7 600 mm RMT 8861.00
1.16.2.8 700 mm RMT 12167.00
1.16.2.9 800 mm RMT 14894.00
1.16.2.10 900 mm RMT 18058.00
1.16.2.11 1000 mm RMT 22907.00
1.16.2.12 1100 mm RMT 26893.00

PHED REVISED BSR 2023 Pipe line work 10


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.16.2.13 1200 mm RMT 29931.00
1.16.2.14 1300 mm RMT 35143.00
1.16.2.15 1400 mm RMT 40568.00
1.16.2.16 1500 mm RMT 49387.00
1.16.2.17 1600 mm RMT 53428.00
1.16.3 Factory Test Pressure 16 Kg/Cm2
1.16.3.1 250mm RMT 3211.00
1.16.3.2 300 mm RMT 3922.00
1.16.3.3 350 mm RMT 4634.00
1.16.3.4 400 mm RMT 5326.00
1.16.3.5 450 mm RMT 6208.00
1.16.3.6 500 mm RMT 7226.00
1.16.3.7 600 mm RMT 9445.00
1.16.3.8 700 mm RMT 13045.00
1.16.3.9 800 mm RMT 15032.00
1.16.3.10 900 mm RMT 19473.00
1.16.3.11 1000 mm RMT 23542.00
1.16.3.12 1100 mm RMT 28613.00
1.16.3.13 1200 mm RMT 33257.00
1.16.3.14 1300 mm RMT 38284.00
1.16.3.15 1400 mm RMT 44125.00
1.16.3.16 1500 mm RMT 51633.00
1.16.3.17 1600 mm RMT 57618.00
1.16.4 Factory Test Pressure 18 Kg/Cm2
1.16.4.1 250mm RMT 3213.00
1.16.4.2 300 mm RMT 3951.00
1.16.4.3 350 mm RMT 4639.00
1.16.4.4 400 mm RMT 5391.00
1.16.4.5 450 mm RMT 6561.00
1.16.4.6 500 mm RMT 7645.00
1.16.4.7 600 mm RMT 10068.00
1.16.4.8 700 mm RMT 13929.00
1.16.4.9 800 mm RMT 16183.00
1.16.4.10 900 mm RMT 20882.00
1.16.4.11 1000 mm RMT 25441.00
1.16.4.12 1100 mm RMT 30693.00
1.16.4.13 1200 mm RMT 34721.00
1.16.4.14 1300 mm RMT 41116.00
1.16.4.15 1400 mm RMT 47142.00
1.16.4.16 1500 mm RMT 55374.00
1.16.4.17 1600 mm RMT 62109.00
1.16.5 Factory Test Pressure 20 Kg/Cm2
1.16.5.1 250mm RMT 3221.00
1.16.5.2 300 mm RMT 3965.00
1.16.5.3 350 mm RMT 4702.00
1.16.5.4 400 mm RMT 5759.00
1.16.5.5 450 mm RMT 7009.00
1.16.5.6 500 mm RMT 8237.00
1.16.5.7 600 mm RMT 10846.00
1.16.5.8 700 mm RMT 15107.00
1.16.5.9 800 mm RMT 18708.00
1.16.5.10 900 mm RMT 22449.00
1.16.5.11 1000 mm RMT 27687.00

PHED REVISED BSR 2023 Pipe line work 11


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.16.5.12 1100 mm RMT 32177.00
1.16.5.13 1200 mm RMT 38163.00
1.16.5.14 1300 mm RMT 43400.00
1.16.5.15 1400 mm RMT 50885.00
1.16.5.16 1500 mm RMT 61359.00
1.16.5.17 1600 mm RMT 67346.00
Laying Jointing and Removing of pipe line
De-jointing and removing of already laid CI/DI pipes of following
diameters in excavated trenches with care, without damaging pipes,
CID joints, valves, specials etc. and other materials and then refilling
of soil after de-laying and de-jointing of pipelines with proper
1.17 compaction and disposing of all surplus soil as directed with in a
lead of 30 mtr. This also include stacking the pipes with care and
transporting the same to div./sub div. store or as directed by EIC
with in the division. (Rates are Exclusive of Earth Work)

1.17.1 80 mm RMT 45.00


1.17.2 100 mm RMT 50.00
1.17.3 125 mm RMT 50.00
1.17.4 150 mm RMT 59.00
1.17.5 200 mm RMT 79.00
1.17.6 250 mm RMT 98.00
1.17.7 300 mm RMT 119.00
1.17.8 350 mm RMT 134.00
1.17.9 400 mm RMT 164.00
1.17.10 450 mm RMT 200.00
1.17.11 500 mm RMT 257.00
1.17.12 600 mm RMT 309.00
1.18 De-jointing and removing of already laid MS pipes of following
diameters in excavated trenches with care, without damaging pipes,
CID joints, valves, specials etc. and other materials and then refilling
of soil after de-laying and de-jointing of pipelines with proper
compaction and disposing of all surplus soil as directed with in a
lead of 30 mtr. This also include stacking the pipes with care and
transporting the same to div./sub div. store or as directed by EIC
with in the division. (Rates are Exclusive of Earth Work)

1.18.1 100 mm RMT 32.00


1.18.2 125 mm RMT 32.00
1.18.3 150 mm RMT 38.00
1.18.4 200 mm RMT 75.00
1.18.5 250 mm RMT 96.00
1.18.6 300 mm RMT 117.00
1.18.7 350 mm RMT 138.00
1.18.8 400 mm RMT 159.00
1.18.9 450 mm RMT 203.00
1.18.10 500 mm RMT 245.00
1.18.11 600 mm RMT 295.00

PHED REVISED BSR 2023 Pipe line work 12


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.19 Laying, Jointing, Testing and Commissioning of uPVC/ PVC Pipes
(Class- 3/ 4) in assorted length with specials, valves etc. including
local handling and transportation from PHED store and then refilling
of soil with proper compaction and disposing of all surplus soil as
directed with in a lead of 30 mtr as per satisfaction of EIC. (Rates are
Exclusive of Earth Work and jointing materials)

1.19.1 90 mm RMT 17.00


1.19.2 110 mm RMT 19.00
1.19.3 125 mm RMT 23.00
1.19.4 140 mm RMT 25.00
1.19.5 160 mm RMT 27.00
1.19.6 180 mm RMT 30.00
1.19.7 200 mm RMT 31.00
1.19.8 225 mm RMT 34.00
1.19.9 250 mm RMT 36.00
1.19.10 280mm RMT 38.00
1.19.11 315 mm RMT 41.00
1.20 Laying, Jointing, Testing and Commissioning of Ductile Iron (DI)
Pipes of any class in assorted length with specials, valves etc.
including local handling and transportation from PHED store and
then refilling of soil with proper compaction and disposing of all
surplus soil as directed with in a lead of 30 mtr as per satisfaction of
EIC. (Rates are Exclusive of Earth Work and jointing materials)

1.20.1 80 mm RMT 48.00


1.20.2 100 mm RMT 50.00
1.20.3 125 mm RMT 52.00
1.20.4 150 mm RMT 64.00
1.20.5 200 mm RMT 80.00
1.20.6 250 mm RMT 100.00
1.20.7 300 mm RMT 118.00
1.20.8 350 mm RMT 138.00
1.20.9 400 mm RMT 168.00
1.20.10 450 mm RMT 210.00
1.20.11 500 mm RMT 270.00
1.20.12 600 mm RMT 317.00
1.21 Laying, Jointing, Testing and Commissioning of AC Pressure Pipes
(Class- 10/15/20) of any class in assorted length with specials, valves
etc. including local handling and transportation from PHED store
and then refilling of soil with proper compaction and disposing of all
surplus soil as directed with in a lead of 30 mtr as per satisfaction of
EIC. (Rates are Exclusive of Earth Work and jointing materials)

1.21.1 80 mm RMT 31.00


1.21.2 100 mm RMT 34.00
1.21.3 125 mm RMT 37.00
1.21.4 150 mm RMT 39.00
1.21.5 200 mm RMT 47.00
1.21.6 250 mm RMT 52.00
1.21.7 300 mm RMT 98.00

PHED REVISED BSR 2023 Pipe line work 13


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.21.8 350 mm RMT 106.00
1.21.9 400 mm RMT 121.00
1.21.10 450 mm RMT 139.00
1.21.11 500 mm RMT 158.00
1.21.12 600 mm RMT 162.00
1.22 Laying, Jointing, Testing and Commissioning of HDPE pipes of any
grade in assorted length with specials, valves etc. with jointing
material/ fixing of necessary jointing material like mechanical
connector i.e. thread/ insert joint/quick release coupler joint
compression fitting joint or flanged joint and jointing pipe in proper
position and jointing of all specials by butt fusion / electro fusion
welding method, including local handling and transportation from
PHED store and then refilling of soil with proper compaction and
disposing of all surplus soil as directed with in a lead of 30 mtr as
per satisfaction of EIC. (Rates are Exclusive of Earth Work and
jointing materials)

1.22.1 90 mm RMT 14.00


1.22.2 110 mm RMT 16.00
1.22.3 125 mm RMT 70.00
1.22.4 140 mm RMT 77.00
1.22.5 160 mm RMT 87.00
1.22.6 180 mm RMT 96.00
1.22.7 200 mm RMT 106.00
1.22.8 225 mm RMT 117.00
AC pipes
1.23 Providing, lowering, laying and jointing in trenches,  standard
lengths  ISI marked AC pressure pipe class 15 manufactured by
MAZZA process as per IS-1592-2003 or amended up to date with
AC coupling and EPDM Rubber sealing rings of Type -3 as per IS:
5382/1985 (Reaffirmed 1998) or amended up to date, including all
taxes , transportation and freight charges, inspection charges,
loading/ unloading charges, stacking of pipes, labour and material,
satisfactory hydraulic testing etc. complete as per technical
specifications and direction of Engineer-in-charge. (excluding earth
work and specials)
Note: These pipes shall only be used for raw water conveyance main
from Canal outlet to raw water reservoirs and interconnection
works.
1.23.1 150 mm dia Cl-15 RMT 727.00
1.23.2 200 mm dia Cl-15 RMT 1183.00
1.23.3 250 mm dia Cl-15 RMT 1621.00
1.23.4 300 mm dia Cl-15 RMT 2347.00
1.23.5 350 mm dia Cl-15 RMT 2974.00
1.23.6 400 mm dia Cl-15 RMT 3937.00
1.23.7 450 mm dia Cl-15 RMT 4625.00
1.23.8 500 mm dia Cl-15 RMT 5855.00
1.23.9 600 mm dia Cl-15 RMT 8345.00

PHED REVISED BSR 2023 Pipe line work 14


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
CI Specials
1.24 Providing, lowering, laying, aligning, fixing in position at all level/
depths CI Class - B specials as per IS : 1538, amended up to date in
trenches complete including all material, labour, testing and
commissioning along with pipe line/ appurtenance as per Technical
Specifications and as per direction of Engineer.
Note : E/w to be measured and paid separately.

Plain ended CI specials including tail piece, spigot end and socket
1.24.1
end.
1.24.1.1 Up to 300 mm dia Kg 111.00
1.24.1.2 Above 300 mm and up to 600 mm dia Kg 129.00
1.24.2 Double flanged CI pipe fittings.
1.24.2.1 Up to 300 mm dia Kg 128.00
1.24.2.2 Above 300 mm and up to 600 mm dia Kg 143.00
House hold tap connections
1.25 Providing Household Tap Connection as per technical specification and
approved drawing as per relevant IS code (amended up to date) from
uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using
PP/MS saddle piece (Complete job).This job includes digging out
suitable size of pits and trench for laying service line in all kinds of soil
(excluding road); depositing and refilling of pit & jhiri with watering &
ramming /compacting in layers and disposal of surplus excavated soil as
directed with in a lead of 100 meter ; providing & fixing of all fitting
duly approved in accordance with specification for potable water
including MS/PP saddle piece, gunmetal ferrule 4.0 mm , GM Full-way
Valve (IS:778 Mark) or ball valve (min. weight 165 gm) and specials,
below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per
ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR
7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia
PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings
in the premises for fixing a tap / meter box (excluding) , inc
accessories with flushing, cleaning, disinfecting and testing of pipe line
complete required for making of service connection complete in all
respect including labour charges . The service line should be laid at
least 45 cm below ground level.
Note: Road cut and restoration is not part of this item and paid
separately.

1.25.1 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 Each 1658.00
mtr.

PHED REVISED BSR 2023 Pipe line work 15


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
1.26 Providing Household Tap Connection as per technical specification
and approved drawing and as per relevant IS code (amended up to
date) from HDPE pipe line up to consumer meter/premises by using
electro fusion saddle piece (Complete job).This job includes digging
out suitable size of pits and trench for laying service line in all kinds
of soil; depositing and refilling of pit & jhiri with watering &
ramming /compacting in layers and disposal of surplus excavated
soil as directed with in a lead of 100 meter ; providing & fixing of all
fitting duly approved in accordance with specification for potable
water including electrofusion saddle piece, gunmetal ferrule 4.0
mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials,
below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as
per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe
PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level
using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia
GI pipes with fittings in the premises for fixing a tap / meter box
(excluding) ,including accessories with flushing, cleaning,
disinfecting and testing of pipe line complete required for making of
service connection complete in all respect including labour charges .
The service line should be laid at least 45 cm below ground level.
Note: Road cut and restoration is not part of this item and paid
separately.

1.26.1 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 Each 1986.00
mtr.
1.27 Providing Household Tap Connection as per technical specification and
approved drawing as per relevant IS code (amended up to date) from
HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises
by using PP mechanical Integrated saddle with inbuilt flow control
valve made out of SS316 designed for 5 LPM discharge at 0.5 bar
pressure , not exceeding the flow of 7 LPM at 2 bar and a
compression elbow, moulded in single piece/ fusion welded
(Complete job) including digging out suitable size of pits and trench for
laying service line in all kinds of soil; depositing and refilling of pit &
jhiri with watering & ramming /compacting in layers and disposal of
surplus excavated soil as directed with in a lead of 100 meter ;
providing & fixing of all fitting duly approved in accordance with
specification for potable water including GM Full-way Valve (IS:778
Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe
PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three
layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above
ground level using PPR-C pipe with standard PPR fittings/ GI pipes in
the premises for fixing a tap / meter box (excluding) ,including
accessories with flushing, cleaning, disinfecting and testing of pipe line
complete required for making of service connection complete in all
respect including labour charges . The service line should be laid at
least 45 cm below ground level.

Note: Road cut and restoration is not part of this item and paid
separately.

PHED REVISED BSR 2023 Pipe line work 16


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 Each 1780.00
1.27.1
mtr.
P & F Bib cock (IS : 781 mark), superior quality of approved make , Each 311.00
1.28 brass 400 gm, 15 mm nominal bore.

P & F Bib cock (IS : 8931 mark), superior quality of approved make, Each 311.00
1.29 chrome plated with complete brass body including brass handle
with wt. 300 to 325 gm.15 mm nominal bore.
Road cutting for house hold service connection in minimum trench Mtr 200.00
width wherever road crossing is required. Road cutting of cement
concrete,WBM, Black top etc. of all thickness shall be done by using
1.30 a concrete cutter machine keeping minimum trench width and
restoration of the road with Cement concrete with PCC M-10 and CC
M-30 grade as per specification and direction of Engineer in charge..

Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE Mtr 44.00
1.31 80 PN 16 as per ISO 4427 MDPE pipe including excavation,
providing, laying & jointing of service line above 5.00 mtr.
Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm ISI Mtr 57.00
marked PN16 SDR 7.4 (IS:15801:2008) PPR-C (Three layered) pipe
1.32
including excavation, providing, laying & jointing of service line
above 5.00 mtr.
PVC-O Pipe
Providing, lowering, laying and jointing in trenches, standard
lengths ISI marked Rigid PVC-O S/S Pipes (push on joints) as per IS-
16647: 2017 (amended up to date) with EPDM Gasket seals on
joints including all taxes , transportation and freight charges,
inspection charges, loading/ unloading charges, stacking of pipes,
laying of pipes, including cost of labour and material, specials (Tee,
1.33
bend etc.), satisfactory hydraulic testing, disinfection etc. complete
as per technical specifications and direction of Engineer-in-charge of
following class and diameter.
Note : Providing and fixing of all requisite specials as per drawing,
design and layout are inclusive in RM measurement of the item and
shall not be paid separately.
1.33.1 PVC-O pipe Class 500 PN-16
1.33.1.1 110 mm dia RMT 874.00
1.33.1.2 160 mm dia RMT 1480.00
1.33.1.3 200 mm dia RMT 1701.00
1.33.1.4 250 mm dia RMT 2280.00
1.33.1.5 315 mm dia RMT 2780.00
1.33.2 PVC-O pipe Class 500 PN-12.5
1.33.2.1 110 mm dia RMT 757.00
1.33.2.2 160 mm dia RMT 1281.00
1.33.2.3 200 mm dia RMT 1462.00
PTMT Bib Cock
Providing and fixing ISI mark (IS 9763: 2000 or amended up to date) Each 196.00
PTMT bib cock 15 mm nominal bore, minimum weight 92 gms and
1.34 length 100 mm as per technical specification, approved make and
direction of Engineer in charge.

PHED REVISED BSR 2023 Pipe line work 17


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
Double chambered restrained joint DI Pipes
1.35 Providing, lowering, laying and jointing of ISI marked Double
chambered restrained joint DI K9 Pipes confirming to IS:8329-2000
(amended upto date); restrained joints are designed and tested as
per ISO 10804: 2018 (to be used for minimum required length as per
design along with double chambered restrained DI fittings to avoid
concrete thrust block at bends) including rubber gaskets confirming
to IS 5382 -1985/8329-2000 with latest amendments and locking
bars & rubber spacers , conveying to work site, rolling and lowering
into trenches, laying true to line, level and perfect linking at joints,
testing and commissioning, including loading and unloading, cutting
of pipes wherever necessary, jointing with DI special (excluding the
cost of restrained joint specials) and rubber gaskets, cleaning the
socket and spigot end with soap solution, applying soft soap to the
socket and spigot ends before insertion of rubber gaskets, jacking
and fixing in perfect conditions etc. The cost includes all accessories
and hydraulic test to the required pressure and cost of all jointing
materials etc complete including all taxes, satisfactory hydraulic
testing, disinfection etc. complete as per technical specifications
and direction of Engineer-in-charge. (excluding earth work)

1.35.1 100 mm RMT 2445.00


1.35.2 150 mm RMT 3427.00
1.35.3 200 mm RMT 4663.00
1.35.4 250 mm RMT 6160.00
1.35.5 300 mm RMT 7701.00
1.35.6 350 mm RMT 9551.00
1.35.7 400 mm RMT 11241.00
1.35.8 450 mm RMT 13251.00
1.35.9 500 mm RMT 15427.00
1.35.10 600 mm RMT 20576.00
1.35.11 700 mm RMT 26773.00
1.35.12 800 mm RMT 29004.00
1.35.13 900 mm RMT 40870.00
1.35.14 1000 mm RMT 47674.00
1.36 Providing, lowering, laying, aligning, fixing in position and jointing
at level/ depths Ductile Iron Double Chambered Restrained Joint
specials confirming to IS 9523 : 2000 of Class K-12 with internal
Cement mortar lining and external Zinc rich paint coating followed
by a finishing layer of bitumen coating duly ISI marked. Joints will be
of Double Chamber Restrained Type as per ISO 10804:2018
including rubber gasket confirming to IS 5382 : 1985 and locking
bars & rubber gaskets etc complete including all taxes as per
technical specifications and direction of Engineer-in-charge,
(excluding earth work).
1.36.1 Upto 300 mm Diameter Kg 229.00
1.36.2 Above 300 mm and up to 600 mm diameter Kg 240.00
1.36.3 Above 600 mm diameter Kg 306.00

PHED REVISED BSR 2023 Pipe line work 18


RajKaj Ref No. : 4242943
Chapter-2

Construction and Commissioning of Tube wells, Open Wells & Hand Pumps.

S. No. Description Unit Rate (Rs.)


TUBE WELLS
2.1 Construction of tube well from ground level & up to 100 mtr depth to
accommodate housing and assembly pipe of following sizes in all type of
alluvium strata unconsolidated formation such as pebbles, boulders etc. by
percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part
II: 1979 (both amended up to date) and technical specifications, with gravel as
per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended
up to date (the work includes the cost of gravel & it's primary packing and
packing during development, lowering of housing & strainer assembly pipes
with supply and wrapping of coir-rope, wherever necessary for arresting fine
sand particles and development work, but excluding the cost of housing and
strainer pipe assembly). The work would be completed after obtaining sand
free water.

2.1.1 Nominal bore 150 mm dia. Mtr 994.00


2.1.2 Nominal bore 200 mm dia. Mtr 1523.00
2.1.3 Nominal bore 250 mm dia. Mtr 1782.00
2.1.4 Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond
100 mtr and up to 200 mtr, rate shall be applicable for only extra depth beyond
100 mtr and up to 200 mtr.

2.1.5 Add 40% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond
200 mtr, rate shall be applicable for only extra depth beyond 200 mtr .

2.2 Construction of Tube Well from ground level and up to 100 mtr. depth to
accommodate housing and assembly pipe in all type of alluvium strata,
unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary
drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both
amended up to date) and technical specifications for removal of overburden.
The work includes the cost of lowering of casing pipe, but excludes the cost of
casing pipe.
2.2.1 Nominal bore 200 mm dia. Mtr 1227.00
2.2.2 Nominal bore 250 mm dia. Mtr 1384.00
2.2.3 Add 15% extra on above item (Item No 2.2.1 to 2.2.2) for drilling depth beyond
100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .

2.3 Construction of tube well after completion of drilling by rotary /percussion


method & up to 100 mtr. depth in all type of rocks by DTH system as per
IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and
technical specifications. The work shall be deemed completed only after
obtaining sand free water. The bore well should have a throughout nominal
size bore beyond casing pipe.
2.3.1 Nominal bore 150 mm dia. Mtr 874.00
2.3.2 Nominal bore 200 mm dia. Mtr 1263.00
2.3.3 Nominal bore 250 mm dia. Mtr 1532.00
2.3.4 Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond
100 mtr and up to 200 mtr from ground level, rate shall be applicable for only
extra depth beyond 100 mtr and up to 200 mtr.

PHED REVISED BSR 2023 TW, OW, HP 19


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.3.5 Add 30% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond
200 mtr and from ground level, rate shall be applicable for only extra depth
beyond 200 mtr .
2.3.6 Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling, where strata
is collapsible and lowering of casing pipe is required . The work includes
lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be
applicable for stretch of collapsible strata only.
2.4 Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH
system & over burden to accommodate casing pipe of following sizes in all
types of soils & over burden including lowering of casing pipes, (if required)
excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II:
1979 (both amended up to date) and technical specifications. The work would
be completed after obtaining sand free water. The tube well should have a
through out bore as per nominal dia of casing pipe.

2.4.1 Nominal bore 150 mm dia. Mtr 726.00


2.4.2 Nominal bore 200 mm dia. Mtr 1089.00
2.4.3 Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond
100 mtr and up to 200 mtr from ground level, rate shall be applicable for only
extra depth beyond 100 mtr and up to 200 mtr.
2.4.4 Add 30% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond
200 mtr and from ground level, rate shall be applicable for only extra depth
beyond 200 mtr .
2.4.5 Add 15% extra on above item (Item No 2.4.1 to 2.4.4) for drilling, where strata
is collapsible and lowering of casing pipe is required . The work includes
lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be
applicable for stretch of collapsible strata only.
2.5 Construction of tube well from ground level and up to 100 mtr. depth and
above of following sizes in all types of soils in alluvium strata, unconsolidated
formation such as pebbles, boulders etc. by "bailing" method and without
gravel packing as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both
amended up to date) and technical specifications. The work includes formation
of cavity at bottom by development with appropriate air compressor or bailer
pumping and also lowering of casing pipe but excluding cost of the casing pipe.
The tube well should have a throughout bore as per nominal dia of casing pipe.
The work would be completed after obtaining sand free water.

2.5.1 Nominal bore 125 mm dia. Mtr 487.00


2.5.2 Nominal bore 150 mm dia. Mtr 543.00
2.5.3 Nominal bore 200 mm dia. Mtr 897.00
2.6 Construction of tube well from ground level and up to 100 mtr depth and
above to accommodate housing assembly pipe in all type of unconsolidated
formation such as pebbles, boulders, collapsible formation etc. by Odex drilling
method as per IS: IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended
up to date) and technical specifications. The work will include lowering of
housing and strainer pipe assembly and casing shoe including cost of casing
shoe, but excluding cost of the casing pipe. The work would be completed after
obtaining sand free water.

2.6.1 Nominal bore 125 mm dia. Mtr 834.00


2.6.2 Nominal Bore 150 mm dia. Mtr 1139.00

PHED REVISED BSR 2023 TW, OW, HP 20


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.6.3 Nominal bore 200 mm dia. Mtr 1670.00
2.6.4 Add 15% extra on above item (Item No 2.6.1 to 2.6.3) for drilling depth beyond
100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .

2.7 Deepening of existing tube well by DTH system beyond existing depth up to 100
mtr. and above in all type of rocks including flushing of tube well and obtaining
sand free water.
2.7.1 Nominal bore 150 mm dia. Mtr 927.00
2.7.2 Nominal bore 200 mm dia. Mtr 1344.00
2.8 Testing verticality of tube well by plumbing system and yield test and draw
down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per Each 8178.00
amended up to date.
2.9 Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS
2800 (Part-1) 1991 or as per amended up to date. Cum. 4109.00

2.10 Development of tube well having depth up to 250 mtr as per IS: 11189- 1985
and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods
Hr. 1456.00
to give sand free water for required yield of the gravel packed tube well.

2.11 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended
up to date of following sizes
2.11.1 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) Mtr 1933.00
2.11.2 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) Mtr 2734.00
2.11.3 250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m) Mtr 4473.00
2.12 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI
marked of following sizes, the slotting should be as per IS:8110-1985.

2.12.1 125 mm dia nominal bore of 4.8 mm thickness Mtr 176.00


2.12.2 150 mm dia nominal bore of 4.8 mm thickness Mtr 209.00
2.12.3 200 mm dia nominal bore of 5.4mm thickness Mtr 317.00
2.12.4 250 mm dia nominal bore of 7.1mm thickness Mtr 397.00
2.13 Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for
casing pipe for submersible cable external work 40 mm dia complete in all Mtr 379.00
respect.
2.14 Supply & Installation of single phase ISI marked submersible motor pump set
of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS
9283-2013 (motor) or as amended up to date of approved make of following
duty condition with required accessories including making connection suitable
for tube well/DCB. The job includes lowering of motor pump, installation of
complete fitting & accessories, jointing of electrical cables up to switch board,
testing of submersible pump set and interconnection up to water mains,
complete in all respect.

2.14.1 Up to 2.0 KW KW 16762.00


2.14.2 Above 2.0 KW KW 13050.00
2.15 Supply & Installation of 3 phase ISI marked submersible motor pump set of
three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-
2013 (motor) or as amended up to date of approved make of following duty
condition with required accessories including making connection suitable for
tube well/DCB. The job includes lowering of motor pump, installation of
complete fitting & accessories, jointing of electrical cables up to switch board,
testing of submersible pump set and interconnection up to water mains,
complete in all respect.

2.15.1 Up to 5.5 KW (7.5 HP) & head up to 120 mtr. KW 9083.00


2.15.2 Up to 5.5 KW (7.5 HP) & head above 120 mtr. KW 9628.00

PHED REVISED BSR 2023 TW, OW, HP 21


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.15.3 7.5 KW (10 HP) & head up to 120 mtr. KW 6844.00
2.15.4 7.5 KW (10 HP) & head above 120 mtr. KW 8320.00
2.15.5 9.3 KW (12.5 HP) & head up to 120 mtr. KW 5800.00
2.15.6 9.3 KW (12.5 HP) & head above 120 mtr. KW 7552.00
2.15.7 11 KW (15 HP) & head up to 120 mtr. KW 5614.00
2.15.8 11 KW (15 HP) & head above 120 mtr. KW 6577.00
2.15.9 13 KW (17.5 HP) & head up to 120 mtr. KW 5603.00
2.15.10 13 KW (17.5 HP) & head above 120 mtr. KW 6400.00
2.15.11 15 KW (20 HP) and above, head up to 120 mtr. KW 5580.00
2.15.12 15 KW (20 HP) and above, head above 120 mtr. KW 6320.00
2.16 Supply and Fixing of Electric feeder panel (having projected canopy)for
submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB,
Indicating Light, Ammeter, Volt meter, connection plate, condensers of
approved make and the panel enclosure should be made out from 18 gauge
M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm
depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly
bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and Each 10009.00
double door including in built locking system. The legs should be embedded in
M-15 cement concrete platform. The size of CC platform should be equal or
bigger than the base size of panel having height of at least 200 mm from
ground level. The operation of panel should be suitable for on 240 Volt AC
Supply.

2.17 Supply and Fixing of electric control feeder panel comprising of suitable rating
MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer,
phase indicators, lighting arrangement etc. complete suitable for three phase
pump set. The panel should have space for energy meter ( supplied by
DISCOM). All these equipments shall be housed by panel box made out from 18
gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x
600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly
bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and
double door including in built locking system. The legs should be embedded in
M-15 cement concrete platform. The size of CC platform should be equal or
bigger than the base size of panel having height of at least 200 mm from
ground level. The panel should have opening of suitable size in front of space
for energy meter with glass for meter reading. The operation of panel should
be suitable for on 440 Volt AC Supply.

2.17.1 Up to 5.00 HP Each 13081.00


2.18 Supply and Fixing of electric control feeder panel comprising of suitable rating
MCCB , fully automatic star-delta starter, over load relay, ampere meter with
CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators,
lighting arrangement etc. complete suitable for three phase pump set. The
panel should have space for energy meter ( supplied by DISCOM). All these
equipments shall be housed by panel box made out from 18 gauge M.S. Sheet
with powder coating. Panel should be of minimum size 900 x 600 x 450 mm
with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with
enclosure box having 4 legs, each leg’s length 18" and double door including in
built locking system. The legs should be embedded in M-15 cement concrete
plat form. The size of CC platform should be equal or bigger than the base size
of panel having height of at least 200 mm from ground level. The panel should
have opening of suitable size in front of space for energy meter with glass for
meter reading. The operation of panel should be suitable for on 440 Volt AC
Supply.

2.18.1 Above 5 HP and up to 10 HP Each 24273.00

PHED REVISED BSR 2023 TW, OW, HP 22


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.18.2 Above 10 HP and up to 15 HP Each 27829.00
2.18.3 Above 15 HP and up to 20 HP Each 32117.00
2.18.4 Above 20 HP and up to 30 HP Each 39375.00
2.19 Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS
694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980
including making connection etc.

2.19.1 3 core 4.0 Sq.mm Mtr 189.00


2.19.2 3 core 6.0 Sq.mm Mtr 283.00
2.19.3 3 core 10.0 Sq.mm Mtr 484.00
2.19.4 3 core 16.0 Sq.mm Mtr 722.00
2.20 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with
aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground
as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick
under layer of sand, second Class bricks covering, refilling earth, compaction
of earth, making necessary connection, testing etc. as required of size.

2.20.1 10.0 Sq.mm, 4 core Mtr 196.00


2.20.2 16.0 Sq.mm, 4 core Mtr 234.00
2.20.3 25.0 Sq.mm, 3.5 core Mtr 324.00
2.20.4 35.0 Sq.mm, 3.5 core Mtr 379.00
2.21 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x
6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I.
'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple,
wire meshed funnel, and C.C. finished chamber covered with hinged type with Each 3651.00
locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete
with alternate layers of salt and coke/charcoal, testing of earth resistance as
required.
2.22 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts
etc. for holding the riser pipe assembly of submersible pump set. Each 696.00

2.23 Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick
100mm wide shroud around the edge so as to form a cap on the top end of
casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm
sizes passing through a hole in the centre of MS sheet. A 25 mm socket with
end plug shall also be welded over top plate. A GI nipple having outside thread
of size 1/2" (for installation pressure gauge) shall be provided & welded with
80mm GI nipple near top plate nipple shall be provided with end plug.

2.23.1 125 mm dia Each 754.00


2.23.2 150 mm dia Each 812.00
2.23.3 200 mm dia Each 986.00
2.23.4 250 mm dia Each 1160.00
2.24 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B" class),
Steel tube as per IS:1239 or amended up to date and zinc coating as per IS
4736, threaded and double flanged (welded) on both ends and two number
25x3mm MS flat welded on both ends between pipe & flange, rubber washer &
nut bolts etc. complete in all respect.
2.24.1 32 mm dia Mtr 430.00
2.24.2 50 mm dia Mtr 678.00
2.24.3 65 mm dia Mtr 765.00
2.24.4 80mm dia Mtr 944.00

PHED REVISED BSR 2023 TW, OW, HP 23


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.25 Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or
amended up to date in PE 80 grade and class PN 10 of following dia. including
HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to
date, along with clamping of submersible cable etc. complete in all respect.

2.25.1 40 mm dia Mtr 87.00


2.25.2 50 mm dia Mtr 136.00
2.25.3 63 mm dia Mtr 213.00
2.25.4 75 mm dia Mtr 303.00
2.25.5 90 mm dia Mtr 430.00
2.26 Providing, installing, testing and commissioning of double flanged bulk flow
meter with removable mechanism, of class B conforming to ISO 4064/1 or
amended up to date of approved make including cost of all material and
labour as per specifications with GI Box (sheet 16 SWG) suitable with locking
arrangement of following dia.
2.26.1 50 mm dia Each 11801.00
2.26.2 65 mm dia Each 13350.00
2.26.3 80 mm dia Each 15752.00
2.27 Providing & Fixing pump safety cage as per specifications or as directed by
Each 1106.00
Engineer in charge.
2.28 Providing and Fixing of ISI marked PVC storage tank of following capacity as
per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI
overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket,
including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and
PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI
quarter turn heavy duty Bib Cocks four no's of superior quality and approved
make, including interconnections complete job.
2.28.1 1000 litres capacity Each 8534.00
2.28.2 2000 litres capacity Each 16436.00
2.29 Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50
mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the
ground and all legs tied up with each other through same size of angle iron kg 117.00
along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank
complete in all respect.
2.30 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved
make of following sizes
2.30.1 65 mm dia Each 2506.00
2.30.2 80 mm dia Each 2830.00
2.31 Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or
amended up to date of approved make, on pump delivery pipe. Each 821.00

2.32 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type
pressure gauge of range 0 to 10 kg. including all jointing material as per Each 1243.00
specification with safety cover.
2.33 Construction of bore hole for shallow depth tube well from ground level to
required depth for following size for all type of relevant strata by percussion/
rotary drilling/ hand boring method excluding cost of casing pipe. The bore
hole should be as per nominal bore of PVC casing pipe. The work will be
complete after obtaining sand free water.
2.33.1 125 mm dia nominal bore Mtr. 347.00
2.33.2 150 mm dia nominal bore Mtr. 387.00
2.33.3 200 mm dia nominal bore Mtr. 551.00
2.33.4 250 mm dia nominal bore Mtr. 775.00

PHED REVISED BSR 2023 TW, OW, HP 24


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.34 Providing and Lowering of ISI mark PVC-U casing and screen pipe as per IS :
12818 : 2010 or amended up to date having pipe thickness as per IS code
suitable for TW and DCB with threading , winding with superior quality of
plastic mesh & rope in three layers with end cap complete as per technical
specification and direction of Engineer In charge.

2.34.1 Shallow well casing pipe (CS) suitable for depth up to 80 mtr.
2.34.1.1 150 mm nominal dia ( internal dia ). Mtr 475.00
2.34.1.2 200 mm nominal dia ( internal dia ). Mtr 872.00
2.34.1.3 250 mm nominal dia ( internal dia ). Mtr. 1362.00
2.34.2 Medium well casing pipe (CM) suitable for depth above 80 mtr and up to 250
mtr.
2.34.2.1 100 mm nominal dia ( internal dia ) Mtr. 282.00
2.34.2.2 125 mm nominal dia ( internal dia ) Mtr. 450.00
2.34.2.3 150 mm nominal dia ( internal dia ) Mtr 616.00
2.34.2.4 200 mm nominal dia ( internal dia ) Mtr 1114.00
2.34.2.5 250 mm nominal dia ( internal dia ) Mtr. 1733.00
2.35 Supply of ISI mark AC pressure pipe class 15 manufactured by MAZZA process
as per IS:1592-2003 or amended up to date, for casing of tube well for
following dia nominal bore, with jointing material PVC coupler as per technical
specification and direction of Engineer In charge.
2.35.1 125 mm nominal dia Mtr 328.00
2.35.2 150 mm nominal dia Mtr 581.00
2.35.3 200 mm nominal dia Mtr 955.00
2.35.4 250 mm nominal dia Mtr 1279.00
2.35.5 300 mm nominal dia Mtr 1855.00
2.36 Making slots of hole size and Nos. as directed by EIC in AC pressure pipe Class
15 as per technical specification for using slotted pipe in TW casing. Per 100 no. 98.00

RCC OPEN WELLS


2.37 Dry sinking of well true & vertical in all types of soil including sand, silt, clay,
mixed up to 25% with gravel and river bed stones up to size 300 mm in any
direction complete as per drawing and technical specification (depth from level
of placing of cutting edge & internal dia, to be taken for measurement) rate
includes all percentage of pebbles, boulders and river bed stones. (depth to be
measured from ground level)
2.37.1 for depth up to 5.00 m P.M. dia
1473.00
P.M. depth
2.37.2 for depth from 5.00 m to 10.0 mtr P.M. dia
2057.00
P.M. depth
2.37.3 for depth from 10.0 m to 15.0 mtr P.M. dia
2468.00
P.M. depth
2.37.4 for depth from 15.0 m to 20.0 mtr and above. P.M. dia
2879.00
P.M. depth

PHED REVISED BSR 2023 TW, OW, HP 25


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.38 Wet sinking of well in all type of strata (soil & boulders in any quantity)
including required operations like chiselling, air and water jetting, hoist drives,
skilled divers etc. for removal of isolated obstructions and minor blasting if
required and lifting of excavated material up to ground level, and spreading the
same with ramming and watering within a radius of 50 m from the site of open
well. Rate includes all percentage of pebbles, boulders and river bed stones.
(depth to be measured from ground level)

2.38.1 for depth up to 5.00m P.M. dia


2131.00
P.M. depth
2.38.2 for depth from 5.00m to 10.0 mtr P.M. dia
3507.00
P.M. depth
2.38.3 for depth from 10.00m to 15.0 mtr P.M. dia
4448.00
P.M. depth
2.38.4 for depth from 15.0 m to 20.0 mtr P.M. dia
5303.00
P.M. depth
2.38.5 for depth from 20.0 m to 25.0 mtr P.M. dia
6443.00
P.M. depth
2.38.6 for depth from 25.0 m to 30.0 mtr and above. P.M. dia
7583.00
P.M. depth
2.39 Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width
and 10 SQM in plan) for construction of open well, lift up to 1.5 Mtr. including
taking out the excavated soil and disposal of surplus excavated soil as directed
within a lead of 50 meter.
2.39.1 All kind of soil CUM 314.00
2.39.2 Ordinary Rock CUM 674.00
2.39.3 Hard Rock (Requiring blasting) CUM 976.00
2.39.4 Hard Rock (Blasting Prohibited) CUM 1355.00
2.40 Add extra over item No. 2.39.1 for every additional lift of 1.5 Mtr. or part
CUM 47.00
thereof : In all kind of soils.
2.41 Add extra over item No. 2.39.2-4 for every additional lift of 1.5 Mtr. or part
CUM 67.00
thereof : In Ordinary rock and hard rock.
2.42 Add 20% extra over item No. 2.39 for excavation in saturated soil where
pumping or baling out of water is required, including shoring strutting where
required and dewatering.
2.43 Labour charges for horizontal boring 100 mm dia in open well in rocky strata
with all types of rock cutting & drilling tools etc. including all T&P required for Mtr 626.00
job including dewatering arrangement.

PHED REVISED BSR 2023 TW, OW, HP 26


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
HAND PUMPS
2.44 Construction of tube well from ground level & up to 100 mtr depth to
accommodate housing and assembly pipe of following sizes in all type of
alluvium strata unconsolidated formation such as pebbles, boulders etc. by
percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part
II: 1979 (both amended up to date) and technical specifications, with gravel as
per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended
up to date (the work includes the cost of gravel & it's primary packing and
packing during development, lowering of housing & strainer assembly pipes
with supply and wrapping of coir-rope, wherever necessary for arresting fine
sand particles and development work, but excluding the cost of housing and
strainer pipe assembly). The work would be completed after obtaining sand
free water.

2.44.1 Nominal bore 125 mm dia. Mtr 666.00


2.44.2 Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of
bore is more than 100 mtr.
2.45 Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH
system & over burden to accommodate casing pipe of following sizes in all
types of soils & over burden including lowering of casing pipes, (if required)
excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II:
1979 (both amended up to date) and technical specifications. The work would
be completed after obtaining sand free water. The tube well should have a
through out bore as per nominal dia of casing pipe.

2.45.1 Nominal bore 100 mm dia. Mtr 470.00


2.45.2 Nominal bore 125 mm dia. Mtr 538.00
2.45.3 Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of
bore is more than 100 mtr.
2.46 Construction of tube well from ground level and up to 100 mtr. depth and
above of following sizes in all types of soils in alluvium strata, unconsolidated
formation such as pebbles, boulders etc. by bailing method and without gravel
packing as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up
to date) and technical specifications. The work includes formation of cavity at
bottom by development with appropriate air compressor or bailer pumping
and also lowering of casing pipe but excluding cost of the casing pipe. The tube
well should have a throughout bore as per nominal dia of casing pipe. The
work would be completed after obtaining sand free water.

2.46.1 Nominal bore 100 mm dia. Mtr 341.00


2.46.2 Nominal bore 125 mm dia. Mtr 373.00
2.47 Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)}
medium of following sizes at site of work.
2.47.1 100 mm dia NB (Thickness of pipe 4.5 mm & mass of tube 12.50 Kg/m) Mtr 1286.00
2.47.2 125 mm dia NB( Thickness of pipe 4.8 mm & mass of tube 16.40 Kg/m) Mtr 1603.00
2.48 Providing and Lowering of ISI mark Medium well PVC-U casing and screen
pipe (CM) as per IS : 12818 : 2010 or amended up to date having pipe thickness
as per IS code suitable for bore well with threading , winding with superior
quality of plastic mesh & rope in three layers with end cap complete as per
technical specification and direction of Engineer In charge.

2.48.1 100 mm nominal dia ( internal dia ).


Mtr 282.00

2.48.2 125 mm nominal dia ( internal dia ).


Mtr 450.00

PHED REVISED BSR 2023 TW, OW, HP 27


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
2.49 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI
marked of following sizes, the slotting should be as per IS:8110-1985.

2.49.1 100 mm dia nominal bore Mtr 138.00


2.49.2 125 mm dia nominal bore Mtr 176.00
2.50 Supply & installation of GI pipe 32 mm medium class “B” with pipe sockets
Mtr 336.00
(heavy duty).
2.51 Supply and installation of ISI marked India Mark II Hand pump set complete
Set 13400.00
with cylinder & 15 connecting rods.
2.52 Supply and installation of ISI Marked India Mark II Hand pump set Extra-Deep
(EDW) complete with cylinder and connecting rods.
2.52.1 EDWHP + 20 Connecting rod. Set 13888.00
2.52.2 EDWHP + 23 Connecting rod + 1 Weight. Set 15529.00
2.52.3 EDWHP + 26 Connecting rod + 2 Weight. Set 16631.00
2.52.4 EDWHP + 30 Connecting rod + 3 Weight. Set 17026.00
2.53 Supply and installation of ISI mark connecting rod as per departmental
Each 180.00
specifications. of 3 meter length.
2.54 Installation of India Mark II/III E.D. I & II hand pump set complete on existing
Each 860.00
platform.
2.55 Construction of 185 cm. dia platform as per approved design & drawing of
Each 3638.00
UNICEF.

PHED REVISED BSR 2023 TW, OW, HP 28


RajKaj Ref No. : 4242943
Chapter 3

RCC Reservoirs
Sr. No. Description Unit Rate (Rs.)

3.1 Construction and commissioning of RCC flat slab Over Head Service Reservoir of
following capacity and staging including all material and labour charges as per the Scope
of work and Technical Specification, consisting of the following main activities: -

a) Topographic survey, preparation of site contour plan, conducting SBC test and its
approval from department before construction. Submission and approval of concrete mix
design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all
around the structure including all material, labour, shuttering, scaffolding etc.
c) OHSR shall be provided with adequate plinth protection all around the structure in a
width starting from edge of structure at GL and extending at least up to 1.0m beyond the
edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick
PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.
d) Providing and applying two coats of food grade epoxy paint on the inside surface roof
slab, and 600 mm height of the vertical wall.
e) Successfully hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof
slab.
g) Providing and applying three coats of cement-based paint on the external surface of the
container, balcony, cone wall, columns & beams etc.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder
from top Slab to bottom Slab inside container.
i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder
with safety cage from balcony to top slab.

j) Providing and fixing water level indicator (float type).


k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting
of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron
vertical post at a maximum spacing of 1500mm centres.
l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red
oxide.
m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the
container (vertical wall & cone wall).
n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5
to 4.5m above GL) from ground.
o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and
connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm
p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow
and washout pipe of the reservoir.
q) Painting the name of the scheme and other details on the reservoir, and any other work
related to structure as per the directions of Engineer-in- Charge, Technical Specification and
Scope of Work.
r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision
for the same shall be taken separately.

3.1.1 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 15 M
3.1.1.1 50 KL capacity Litre 41.69
3.1.1.2 75 KL capacity Litre 34.38
3.1.2 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-III & STAGING 15 M
3.1.2.1 50 KL capacity Litre 43.28
3.1.2.2 75 KL capacity Litre 35.28

PHED REVISED BSR 20223 RCC Reservoirs 29


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.1.3 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-IV & STAGING 15 M
3.1.3.1 50 KL capacity Litre 45.96
3.1.3.2 75 KL capacity Litre 37.82
3.1.4 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M
3.1.4.1 50 KL capacity Litre 38.16
3.1.4.2 75 KL capacity Litre 29.85
3.1.5 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 15 M
3.1.5.1 50 KL capacity Litre 38.95
3.1.5.2 75 KL capacity Litre 30.60
3.1.6 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 15 M
3.1.6.1 50 KL capacity Litre 39.72
3.1.6.2 75 KL capacity Litre 31.10
3.1.7 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-II & STAGING 15 M
3.1.7.1 50 KL capacity Litre 36.69
3.1.7.2 75 KL capacity Litre 28.70
3.1.8 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-III & STAGING 15 M
3.1.8.1 50 KL capacity Litre 37.81
3.1.8.2 75 KL capacity Litre 29.55
3.1.9 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-IV & STAGING 15 M
3.1.9.1 50 KL capacity Litre 38.51
3.1.9.2 75 KL capacity Litre 30.17
3.2 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of
following capacity and staging as per the Scope of work and Technical specifications,
consisting of the following main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its
approval from department before construction. Submission and approval of concrete mix
design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all
around the structure including all material, labour, shuttering, scaffolding etc.
c) OHSR shall be provided with adequate plinth protection all around the structure in a
width starting from edge of structure at GL and extending at least up to 1.0m beyond the
edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick
PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.
d) Providing and applying two coats of food grade epoxy paint on the inside surface on the
top dome, edge beam and 600 mm height of the vertical wall.
e) Conducting successfully hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top
Dome.
g) Providing and applying three coats of cement-based paint on the external surface of the
container, balcony, cone wall, columns & beams etc..
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder
from top dome/Slab to bottom dome/Slab inside container.
i) Providing and fixing of MS section ladder from the last landing to balcony having railing all
around it and MS ladder with safety cage from balcony to top dome/slab.
j) Providing and fixing water level indicator (float type).

PHED REVISED BSR 20223 RCC Reservoirs 30


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

k) Providing and fixing of hand railing all around the balcony, top dome and staircase
consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm
angle iron vertical post at a maximum spacing of 1500mm centres.
l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red
oxide.
m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the
container (vertical wall & cone wall).
n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5
to 4.5m above GL) from ground.
o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and
connecting it to the conical cover of SS ventilator with two separate GI strips of
50mmX3mm.
p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet,
overflow and washout pipe of the reservoir.
q) Painting the name of the scheme and other details on the reservoir, and any other work
related to structure as per the directions of Engineer-in- Charge, Technical Specification and
Scope of Work.
r) Inlet, outlet, overflow, washout pipes and valves are not included in this work,
provision for the same shall be taken separately.

3.2.1 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 18 M
3.2.1.1 100 KL capacity Litre 30.79
3.2.1.2 150KL capacity Litre 24.05
3.2.1.3 200KL capacity Litre 21.01
3.2.1.4 250KL capacity Litre 20.45
3.2.1.5 300KL capacity Litre 21.07
3.2.1.6 400KL capacity Litre 19.15
3.2.1.7 500KL capacity Litre 18.28
3.2.1.8 600 KL capacity Litre 16.20
3.2.1.9 700 KL capacity Litre 15.51
3.2.1.10 800 KL capacity Litre 14.94
3.2.1.11 900 KL capacity Litre 14.45
3.2.1.12 1000 KL capacity Litre 14.03
3.2.1.13 1250 KL capacity Litre 13.17
3.2.1.14 1500 KL capacity Litre 12.46
3.2.1.15 1750 KL capacity Litre 11.86
3.2.1.16 2000 KL capacity Litre 11.36
3.2.2 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-III & STAGING 18 M
3.2.2.1 100 KL capacity Litre 31.38
3.2.2.2 150KL capacity Litre 24.80
3.2.2.3 200KL capacity Litre 21.62
3.2.2.4 250KL capacity Litre 21.27
3.2.2.5 300KL capacity Litre 21.60
3.2.2.6 400KL capacity Litre 19.70
3.2.2.7 500KL capacity Litre 18.80
3.2.2.8 600 KL capacity Litre 16.56
3.2.2.9 700 KL capacity Litre 15.85
3.2.2.10 800 KL capacity Litre 15.27
3.2.2.11 900 KL capacity Litre 14.76
3.2.2.12 1000 KL capacity Litre 14.33
3.2.2.13 1250 KL capacity Litre 13.46
3.2.2.14 1500 KL capacity Litre 12.77
3.2.2.15 1750 KL capacity Litre 12.23

PHED REVISED BSR 20223 RCC Reservoirs 31


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.2.16 2000 KL capacity Litre 11.78


3.2.3 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-IV & STAGING 18 M
3.2.3.1 100 KL capacity Litre 33.36
3.2.3.2 150KL capacity Litre 26.44
3.2.3.3 200KL capacity Litre 22.88
3.2.3.4 250KL capacity Litre 22.74
3.2.3.5 300KL capacity Litre 22.96
3.2.3.6 400KL capacity Litre 20.60
3.2.3.7 500KL capacity Litre 19.42
3.2.3.8 600 KL capacity Litre 17.74
3.2.3.9 700 KL capacity Litre 16.85
3.2.3.10 800 KL capacity Litre 16.12
3.2.3.11 900 KL capacity Litre 15.49
3.2.3.12 1000 KL capacity Litre 14.96
3.2.3.13 1250 KL capacity Litre 13.88
3.2.3.14 1500 KL capacity Litre 13.15
3.2.3.15 1750 KL capacity Litre 12.50
3.2.3.16 2000 KL capacity Litre 11.96
3.2.4 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M
3.2.4.1 100 KL capacity Litre 27.53
3.2.4.2 150KL capacity Litre 21.22
3.2.4.3 200KL capacity Litre 18.93
3.2.4.4 250KL capacity Litre 18.06
3.2.4.5 300KL capacity Litre 17.97
3.2.4.6 400KL capacity Litre 14.91
3.2.4.7 500KL capacity Litre 14.74
3.2.4.8 600 KL capacity Litre 13.19
3.2.4.9 700 KL capacity Litre 12.47
3.2.4.10 800 KL capacity Litre 11.89
3.2.4.11 900 KL capacity Litre 11.39
3.2.4.12 1000 KL capacity Litre 10.97
3.2.4.13 1250 KL capacity Litre 10.11
3.2.4.14 1500 KL capacity Litre 9.47
3.2.4.15 1750 KL capacity Litre 8.95
3.2.4.16 2000 KL capacity Litre 8.53
3.2.5 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 18 M
3.2.5.1 100 KL capacity Litre 29.06
3.2.5.2 150KL capacity Litre 22.55
3.2.5.3 200KL capacity Litre 20.09
3.2.5.4 250KL capacity Litre 19.45
3.2.5.5 300KL capacity Litre 19.43
3.2.5.6 400KL capacity Litre 16.23
3.2.5.7 500KL capacity Litre 15.84
3.2.5.8 600 KL capacity Litre 14.30
3.2.5.9 700 KL capacity Litre 13.55
3.2.5.10 800 KL capacity Litre 12.93
3.2.5.11 900 KL capacity Litre 12.41
3.2.5.12 1000 KL capacity Litre 11.97
3.2.5.13 1250 KL capacity Litre 11.08
3.2.5.14 1500 KL capacity Litre 10.39
3.2.5.15 1750 KL capacity Litre 9.85
3.2.5.16 2000 KL capacity Litre 9.41

PHED REVISED BSR 20223 RCC Reservoirs 32


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.6 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 18 M
3.2.6.1 100 KL capacity Litre 31.74
3.2.6.2 150KL capacity Litre 24.98
3.2.6.3 200KL capacity Litre 21.66
3.2.6.4 250KL capacity Litre 21.72
3.2.6.5 300KL capacity Litre 21.29
3.2.6.6 400KL capacity Litre 17.58
3.2.6.7 500KL capacity Litre 17.04
3.2.6.8 600 KL capacity Litre 15.10
3.2.6.9 700 KL capacity Litre 14.26
3.2.6.10 800 KL capacity Litre 13.57
3.2.6.11 900 KL capacity Litre 12.99
3.2.6.12 1000 KL capacity Litre 12.50
3.2.6.13 1250 KL capacity Litre 11.50
3.2.6.14 1500 KL capacity Litre 10.75
3.2.6.15 1750 KL capacity Litre 10.16
3.2.6.16 2000 KL capacity Litre 9.67
3.2.7 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-II & STAGING 18 M
3.2.7.1 100 KL capacity Litre 24.90
3.2.7.2 150KL capacity Litre 19.44
3.2.7.3 200KL capacity Litre 17.25
3.2.7.4 250KL capacity Litre 15.99
3.2.7.5 300KL capacity Litre 15.75
3.2.7.6 400KL capacity Litre 13.93
3.2.7.7 500KL capacity Litre 12.86
3.2.7.8 600 KL capacity Litre 12.10
3.2.7.9 700 KL capacity Litre 11.42
3.2.7.10 800 KL capacity Litre 10.87
3.2.7.11 900 KL capacity Litre 10.40
3.2.7.12 1000 KL capacity Litre 10.01
3.2.7.13 1250 KL capacity Litre 9.21
3.2.7.14 1500 KL capacity Litre 8.61
3.2.7.15 1750 KL capacity Litre 8.13
3.2.7.16 2000 KL capacity Litre 7.74
3.2.8 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-III & STAGING 18 M
3.2.8.1 100 KL capacity Litre 25.42
3.2.8.2 150KL capacity Litre 20.02
3.2.8.3 200KL capacity Litre 17.66
3.2.8.4 250KL capacity Litre 16.68
3.2.8.5 300KL capacity Litre 16.18
3.2.8.6 400KL capacity Litre 14.44
3.2.8.7 500KL capacity Litre 13.35
3.2.8.8 600 KL capacity Litre 12.62
3.2.8.9 700 KL capacity Litre 11.93
3.2.8.10 800 KL capacity Litre 11.36
3.2.8.11 900 KL capacity Litre 10.88
3.2.8.12 1000 KL capacity Litre 10.47
3.2.8.13 1250 KL capacity Litre 9.65
3.2.8.14 1500 KL capacity Litre 9.03
3.2.8.15 1750 KL capacity Litre 8.53
3.2.8.16 2000 KL capacity Litre 8.13
3.2.9 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-IV & STAGING 18 M

PHED REVISED BSR 20223 RCC Reservoirs 33


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.9.1 100 KL capacity Litre 26.85


3.2.9.2 150KL capacity Litre 20.87
3.2.9.3 200KL capacity Litre 18.41
3.2.9.4 250KL capacity Litre 18.02
3.2.9.5 300KL capacity Litre 17.31
3.2.9.6 400KL capacity Litre 15.16
3.2.9.7 500KL capacity Litre 13.96
3.2.9.8 600 KL capacity Litre 13.15
3.2.9.9 700 KL capacity Litre 12.44
3.2.9.10 800 KL capacity Litre 11.85
3.2.9.11 900 KL capacity Litre 11.37
3.2.9.12 1000 KL capacity Litre 10.94
3.2.9.13 1250 KL capacity Litre 10.10
3.2.9.14 1500 KL capacity Litre 9.46
3.2.9.15 1750 KL capacity Litre 8.94
3.2.9.16 2000 KL capacity Litre 8.53
3.2.10 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 20 M
3.2.10.1 100 KL capacity Litre 33.08
3.2.10.2 150KL capacity Litre 25.91
3.2.10.3 200KL capacity Litre 22.35
3.2.10.4 250KL capacity Litre 21.47
3.2.10.5 300KL capacity Litre 22.08
3.2.10.6 400KL capacity Litre 19.92
3.2.10.7 500KL capacity Litre 18.71
3.2.10.8 600 KL capacity Litre 17.20
3.2.10.9 700 KL capacity Litre 16.39
3.2.10.10 800 KL capacity Litre 15.72
3.2.10.11 900 KL capacity Litre 15.16
3.2.10.12 1000 KL capacity Litre 14.66
3.2.10.13 1250 KL capacity Litre 13.60
3.2.10.14 1500 KL capacity Litre 12.77
3.2.10.15 1750 KL capacity Litre 12.12
3.2.10.16 2000 KL capacity Litre 11.59
3.2.11 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-III & STAGING 20 M
3.2.11.1 100 KL capacity Litre 33.12
3.2.11.2 150KL capacity Litre 26.27
3.2.11.3 200KL capacity Litre 22.64
3.2.11.4 250KL capacity Litre 22.19
3.2.11.5 300KL capacity Litre 22.68
3.2.11.6 400KL capacity Litre 20.47
3.2.11.7 500KL capacity Litre 19.22
3.2.11.8 600 KL capacity Litre 17.24
3.2.11.9 700 KL capacity Litre 16.49
3.2.11.10 800 KL capacity Litre 15.86
3.2.11.11 900 KL capacity Litre 15.33
3.2.11.12 1000 KL capacity Litre 14.87
3.2.11.13 1250 KL capacity Litre 13.94
3.2.11.14 1500 KL capacity Litre 13.22
3.2.11.15 1750 KL capacity Litre 12.64
3.2.11.16 2000 KL capacity Litre 12.16
3.2.12 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-IV & STAGING 20 M
3.2.12.1 100 KL capacity Litre 35.26

PHED REVISED BSR 20223 RCC Reservoirs 34


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.12.2 150KL capacity Litre 28.32


3.2.12.3 200KL capacity Litre 24.05
3.2.12.4 250KL capacity Litre 24.10
3.2.12.5 300KL capacity Litre 24.24
3.2.12.6 400KL capacity Litre 21.72
3.2.12.7 500KL capacity Litre 20.13
3.2.12.8 600 KL capacity Litre 18.34
3.2.12.9 700 KL capacity Litre 17.40
3.2.12.10 800 KL capacity Litre 16.62
3.2.12.11 900 KL capacity Litre 15.98
3.2.12.12 1000 KL capacity Litre 15.41
3.2.12.13 1250 KL capacity Litre 14.29
3.2.12.14 1500 KL capacity Litre 13.43
3.2.12.15 1750 KL capacity Litre 12.74
3.2.12.16 2000 KL capacity Litre 12.18
3.2.13 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 20 M
3.2.13.1 100 KL capacity Litre 30.01
3.2.13.2 150KL capacity Litre 23.04
3.2.13.3 200KL capacity Litre 20.18
3.2.13.4 250KL capacity Litre 19.09
3.2.13.5 300KL capacity Litre 18.90
3.2.13.6 400KL capacity Litre 16.78
3.2.13.7 500KL capacity Litre 15.30
3.2.13.8 600 KL capacity Litre 14.19
3.2.13.9 700 KL capacity Litre 13.32
3.2.13.10 800 KL capacity Litre 12.60
3.2.13.11 900 KL capacity Litre 12.00
3.2.13.12 1000 KL capacity Litre 11.50
3.2.13.13 1250 KL capacity Litre 10.49
3.2.13.14 1500 KL capacity Litre 9.72
3.2.13.15 1750 KL capacity Litre 9.13
3.2.13.16 2000 KL capacity Litre 8.64
3.2.14 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 20 M
3.2.14.1 100 KL capacity Litre 30.87
3.2.14.2 150KL capacity Litre 23.75
3.2.14.3 200KL capacity Litre 21.05
3.2.14.4 250KL capacity Litre 20.52
3.2.14.5 300KL capacity Litre 20.36
3.2.14.6 400KL capacity Litre 18.14
3.2.14.7 500KL capacity Litre 16.63
3.2.14.8 600 KL capacity Litre 14.82
3.2.14.9 700 KL capacity Litre 14.05
3.2.14.10 800 KL capacity Litre 13.24
3.2.14.11 900 KL capacity Litre 12.53
3.2.14.12 1000 KL capacity Litre 12.08
3.2.14.13 1250 KL capacity Litre 11.17
3.2.14.14 1500 KL capacity Litre 10.48
3.2.14.15 1750 KL capacity Litre 9.93
3.2.14.16 2000 KL capacity Litre 9.48
3.2.15 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 20 M
3.2.15.1 100 KL capacity Litre 33.38
3.2.15.2 150KL capacity Litre 26.41

PHED REVISED BSR 20223 RCC Reservoirs 35


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.15.3 200KL capacity Litre 22.72


3.2.15.4 250KL capacity Litre 22.97
3.2.15.5 300KL capacity Litre 22.49
3.2.15.6 400KL capacity Litre 19.67
3.2.15.7 500KL capacity Litre 17.98
3.2.15.8 600 KL capacity Litre 15.44
3.2.15.9 700 KL capacity Litre 14.63
3.2.15.10 800 KL capacity Litre 13.97
3.2.15.11 900 KL capacity Litre 13.42
3.2.15.12 1000 KL capacity Litre 12.93
3.2.15.13 1250 KL capacity Litre 11.98
3.2.15.14 1500 KL capacity Litre 11.24
3.2.15.15 1750 KL capacity Litre 10.66
3.2.15.16 2000 KL capacity Litre 10.17
3.2.16 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-II & STAGING 20 M
3.2.16.1 100 KL capacity Litre 27.21
3.2.16.2 150KL capacity Litre 21.07
3.2.16.3 200KL capacity Litre 18.33
3.2.16.4 250KL capacity Litre 17.05
3.2.16.5 300KL capacity Litre 16.65
3.2.16.6 400KL capacity Litre 14.57
3.2.16.7 500KL capacity Litre 13.46
3.2.16.8 600 KL capacity Litre 12.80
3.2.16.9 700 KL capacity Litre 12.04
3.2.16.10 800 KL capacity Litre 11.41
3.2.16.11 900 KL capacity Litre 10.88
3.2.16.12 1000 KL capacity Litre 10.43
3.2.16.13 1250 KL capacity Litre 9.54
3.2.16.14 1500 KL capacity Litre 8.86
3.2.16.15 1750 KL capacity Litre 8.33
3.2.16.16 2000 KL capacity Litre 7.89
3.2.17 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-III & STAGING 20 M
3.2.17.1 100 KL capacity Litre 27.17
3.2.17.2 150KL capacity Litre 21.22
3.2.17.3 200KL capacity Litre 18.70
3.2.17.4 250KL capacity Litre 17.70
3.2.17.5 300KL capacity Litre 17.14
3.2.17.6 400KL capacity Litre 15.06
3.2.17.7 500KL capacity Litre 13.94
3.2.17.8 600 KL capacity Litre 13.54
3.2.17.9 700 KL capacity Litre 12.78
3.2.17.10 800 KL capacity Litre 12.15
3.2.17.11 900 KL capacity Litre 11.62
3.2.17.12 1000 KL capacity Litre 11.17
3.2.17.13 1250 KL capacity Litre 10.27
3.2.17.14 1500 KL capacity Litre 9.59
3.2.17.15 1750 KL capacity Litre 9.05
3.2.17.16 2000 KL capacity Litre 8.61
3.2.18 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-IV & STAGING 20 M
3.2.18.1 100 KL capacity Litre 28.38
3.2.18.2 150KL capacity Litre 21.88
3.2.18.3 200KL capacity Litre 19.41

PHED REVISED BSR 20223 RCC Reservoirs 36


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.18.4 250KL capacity Litre 18.91


3.2.18.5 300KL capacity Litre 18.25
3.2.18.6 400KL capacity Litre 15.89
3.2.18.7 500KL capacity Litre 14.60
3.2.18.8 600 KL capacity Litre 14.03
3.2.18.9 700 KL capacity Litre 13.28
3.2.18.10 800 KL capacity Litre 12.66
3.2.18.11 900 KL capacity Litre 12.12
3.2.18.12 1000 KL capacity Litre 11.68
3.2.18.13 1250 KL capacity Litre 10.77
3.2.18.14 1500 KL capacity Litre 10.08
3.2.18.15 1750 KL capacity Litre 9.54
3.2.18.16 2000 KL capacity Litre 9.09
3.2.19 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 22 M
3.2.19.1 100 KL capacity Litre 35.02
3.2.19.2 150KL capacity Litre 26.81
3.2.19.3 200KL capacity Litre 23.24
3.2.19.4 250KL capacity Litre 22.64
3.2.19.5 300KL capacity Litre 22.67
3.2.19.6 400KL capacity Litre 20.37
3.2.19.7 500KL capacity Litre 19.22
3.2.19.8 600 KL capacity Litre 17.66
3.2.19.9 700 KL capacity Litre 16.79
3.2.19.10 800 KL capacity Litre 16.06
3.2.19.11 900 KL capacity Litre 15.45
3.2.19.12 1000 KL capacity Litre 14.92
3.2.19.13 1250 KL capacity Litre 13.83
3.2.19.14 1500 KL capacity Litre 12.96
3.2.19.15 1750 KL capacity Litre 12.27
3.2.19.16 2000 KL capacity Litre 11.70
3.2.20 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-III & STAGING 22 M
3.2.20.1 100 KL capacity Litre 35.03
3.2.20.2 150KL capacity Litre 27.14
3.2.20.3 200KL capacity Litre 23.56
3.2.20.4 250KL capacity Litre 23.00
3.2.20.5 300KL capacity Litre 23.29
3.2.20.6 400KL capacity Litre 20.93
3.2.20.7 500KL capacity Litre 19.72
3.2.20.8 600 KL capacity Litre 17.89
3.2.20.9 700 KL capacity Litre 17.04
3.2.20.10 800 KL capacity Litre 16.33
3.2.20.11 900 KL capacity Litre 15.73
3.2.20.12 1000 KL capacity Litre 15.22
3.2.20.13 1250 KL capacity Litre 14.18
3.2.20.14 1500 KL capacity Litre 13.38
3.2.20.15 1750 KL capacity Litre 12.74
3.2.20.16 2000 KL capacity Litre 12.21
3.2.21 Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-IV & STAGING 22 M
3.2.21.1 100 KL capacity Litre 36.66
3.2.21.2 150KL capacity Litre 29.35
3.2.21.3 200KL capacity Litre 24.62
3.2.21.4 250KL capacity Litre 24.59

PHED REVISED BSR 20223 RCC Reservoirs 37


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.21.5 300KL capacity Litre 25.03


3.2.21.6 400KL capacity Litre 21.88
3.2.21.7 500KL capacity Litre 20.44
3.2.21.8 600 KL capacity Litre 18.64
3.2.21.9 700 KL capacity Litre 17.67
3.2.21.10 800 KL capacity Litre 16.87
3.2.21.11 900 KL capacity Litre 16.19
3.2.21.12 1000 KL capacity Litre 15.60
3.2.21.13 1250 KL capacity Litre 14.43
3.2.21.14 1500 KL capacity Litre 13.54
3.2.21.15 1750 KL capacity Litre 12.83
3.2.21.16 2000 KL capacity Litre 12.25
3.2.22 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M
3.2.22.1 100 KL capacity Litre 32.31
3.2.22.2 150KL capacity Litre 24.27
3.2.22.3 200KL capacity Litre 21.41
3.2.22.4 250KL capacity Litre 20.27
3.2.22.5 300KL capacity Litre 19.60
3.2.22.6 400KL capacity Litre 17.26
3.2.22.7 500KL capacity Litre 15.74
3.2.22.8 600 KL capacity Litre 14.25
3.2.22.9 700 KL capacity Litre 13.37
3.2.22.10 800 KL capacity Litre 12.66
3.2.22.11 900 KL capacity Litre 12.06
3.2.22.12 1000 KL capacity Litre 11.55
3.2.22.13 1250 KL capacity Litre 10.54
3.2.22.14 1500 KL capacity Litre 9.78
3.2.22.15 1750 KL capacity Litre 9.18
3.2.22.16 2000 KL capacity Litre 8.69
3.2.23 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-III & STAGING 22 M
3.2.23.1 100 KL capacity Litre 32.63
3.2.23.2 150KL capacity Litre 24.75
3.2.23.3 200KL capacity Litre 21.82
3.2.23.4 250KL capacity Litre 21.12
3.2.23.5 300KL capacity Litre 21.05
3.2.23.6 400KL capacity Litre 18.52
3.2.23.7 500KL capacity Litre 16.98
3.2.23.8 600 KL capacity Litre 15.72
3.2.23.9 700 KL capacity Litre 14.77
3.2.23.10 800 KL capacity Litre 13.98
3.2.23.11 900 KL capacity Litre 13.39
3.2.23.12 1000 KL capacity Litre 12.90
3.2.23.13 1250 KL capacity Litre 11.89
3.2.23.14 1500 KL capacity Litre 11.12
3.2.23.15 1750 KL capacity Litre 10.52
3.2.23.16 2000 KL capacity Litre 10.01
3.2.24 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 22 M
3.2.24.1 100 KL capacity Litre 35.32
3.2.24.2 150KL capacity Litre 27.02
3.2.24.3 200KL capacity Litre 23.38
3.2.24.4 250KL capacity Litre 23.62
3.2.24.5 300KL capacity Litre 23.13

PHED REVISED BSR 20223 RCC Reservoirs 38


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.24.6 400KL capacity Litre 20.04


3.2.24.7 500KL capacity Litre 18.35
3.2.24.8 600 KL capacity Litre 17.32
3.2.24.9 700 KL capacity Litre 16.30
3.2.24.10 800 KL capacity Litre 15.55
3.2.24.11 900 KL capacity Litre 14.92
3.2.24.12 1000 KL capacity Litre 14.37
3.2.24.13 1250 KL capacity Litre 13.29
3.2.24.14 1500 KL capacity Litre 12.46
3.2.24.15 1750 KL capacity Litre 11.80
3.2.24.16 2000 KL capacity Litre 11.27
3.2.25 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-II & STAGING 22 M
3.2.25.1 100 KL capacity Litre 28.99
3.2.25.2 150KL capacity Litre 22.39
3.2.25.3 200KL capacity Litre 19.34
3.2.25.4 250KL capacity Litre 18.24
3.2.25.5 300KL capacity Litre 17.38
3.2.25.6 400KL capacity Litre 15.14
3.2.25.7 500KL capacity Litre 13.92
3.2.25.8 600 KL capacity Litre 12.78
3.2.25.9 700 KL capacity Litre 11.97
3.2.25.10 800 KL capacity Litre 11.30
3.2.25.11 900 KL capacity Litre 10.75
3.2.25.12 1000 KL capacity Litre 10.27
3.2.25.13 1250 KL capacity Litre 9.34
3.2.25.14 1500 KL capacity Litre 8.64
3.2.25.15 1750 KL capacity Litre 8.08
3.2.25.16 2000 KL capacity Litre 7.63
3.2.26 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-III & STAGING 22 M
3.2.26.1 100 KL capacity Litre 29.31
3.2.26.2 150KL capacity Litre 22.33
3.2.26.3 200KL capacity Litre 19.48
3.2.26.4 250KL capacity Litre 18.54
3.2.26.5 300KL capacity Litre 17.95
3.2.26.6 400KL capacity Litre 15.65
3.2.26.7 500KL capacity Litre 14.41
3.2.26.8 600 KL capacity Litre 13.30
3.2.26.9 700 KL capacity Litre 12.48
3.2.26.10 800 KL capacity Litre 11.82
3.2.26.11 900 KL capacity Litre 11.27
3.2.26.12 1000 KL capacity Litre 10.80
3.2.26.13 1250 KL capacity Litre 9.87
3.2.26.14 1500 KL capacity Litre 9.16
3.2.26.15 1750 KL capacity Litre 8.60
3.2.26.16 2000 KL capacity Litre 8.14
3.2.27 Rates for RCC OHSR,SBC 18 T/sqm, SEISMIC ZONE-IV & STAGING 22 M
3.2.27.1 100 KL capacity Litre 29.92
3.2.27.2 150KL capacity Litre 23.01
3.2.27.3 200KL capacity Litre 20.18
3.2.27.4 250KL capacity Litre 19.49
3.2.27.5 300KL capacity Litre 18.94
3.2.27.6 400KL capacity Litre 16.34

PHED REVISED BSR 20223 RCC Reservoirs 39


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.2.27.7 500KL capacity Litre 15.01


3.2.27.8 600 KL capacity Litre 13.86
3.2.27.9 700 KL capacity Litre 13.06
3.2.27.10 800 KL capacity Litre 12.41
3.2.27.11 900 KL capacity Litre 11.85
3.2.27.12 1000 KL capacity Litre 11.39
3.2.27.13 1250 KL capacity Litre 10.46
3.2.27.14 1500 KL capacity Litre 9.75
3.2.27.15 1750 KL capacity Litre 9.19
3.2.27.16 2000 KL capacity Litre 8.73
3.2.28 For staging above 22 Mtr ( only in exceptional condition where hydraulics not permit) add
2% per Mtr above 22 Mtr.
3.3 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the
Scope of work and Technical specification, consisting of the following main activities: -

a) Topographic survey, preparation of site contour plan, conducting SBC test and its
approval from department before construction. Submission and approval of concrete mix
design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour
and material charges including providing and fixing of accessories such as SS ladder, SS
manhole frame and covers, water level indicator (float type), SS ventilator with SS screen,
float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.
c) CWR shall be provided with adequate plinth protection all around the structure in a width
starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical
wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over
150mm thick compacted soil fill.
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the
roof slab, and 600 mm height of the vertical wall.
e) Successful hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the roof Slab.
g) Providing and applying three coats of cement-based paint on the remaining external
surface area of the structure.

h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder
from roof slab to bottom Slab, inside container. Providing and fixing water level indicator
(Float type).
i) Providing and fixing MS ladder from ground to top slab.
j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of
red oxide.
k) Providing and fixing of 150mm wide water bar for the construction joints in the container.
l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet,
overflow and washout pipes of the reservoir.
m) Inlet, outlet, overflow, washout pipes and valves are not included in this work,
provision for the same shall be taken separately.

3.3.1 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC
ZONE-2,3 & 4
3.3.1.1 50 KL capacity Litre 8.61
3.3.1.2 75 KL capacity Litre 7.99
3.3.1.3 100 KL capacity Litre 7.95
3.3.1.4 150KL capacity Litre 7.14
3.3.1.5 200KL capacity Litre 6.58
3.3.1.6 250KL capacity Litre 6.26

PHED REVISED BSR 20223 RCC Reservoirs 40


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.3.1.7 300KL capacity Litre 6.08


3.3.2 Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 &
4
3.3.2.1 50 KL capacity Litre 8.67
3.3.2.2 75 KL capacity Litre 8.05
3.3.2.3 100 KL capacity Litre 7.99
3.3.2.4 150KL capacity Litre 7.03
3.3.2.5 200KL capacity Litre 6.63
3.3.2.6 250KL capacity Litre 6.26
3.3.2.7 300KL capacity Litre 6.18
3.4 Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope
of work and Technical specification, consisting of the following main activities: -

a) Topographic survey, preparation of site contour plan, conducting SBC test and its
approval from department before construction. Submission and approval of concrete mix
design and water quality test report for water to be used in construction. .
b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour
and material charges including providing and fixing of accessories such as SS ladder, SS
manhole frame and covers, water level indicator (float type), SS ventilator with SS screen,
float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.
c) CWR shall be provided with adequate plinth protection all around the structure in a width
starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical
wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over
150mm thick compacted soil fill.
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the
roof slab, and 600 mm height of the vertical wall.
e) Successful hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the roof Slab.
g) Providing and applying three coats of cement-based paint on the remaining external
surface area of the structure.

h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder
from roof slab to bottom Slab, inside container. Providing and fixing water level indicator
(Float type).
i) Providing and fixing MS ladder from ground to top slab.
j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of
red oxide.
k) Providing and fixing of 150mm wide water bar for the construction joints in the
container.
l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet,
overflow and washout pipes of the reservoir.
m) Inlet, outlet, overflow, washout pipes and valves are not included in this work,
provision for the same shall be taken separately.

3.4.1 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC
ZONE2,3 & 4
3.4.1.1 400 KL capacity Litre 6.51
3.4.2 Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4

3.4.2.1 400 KL capacity Litre 6.35


3.4.3 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC
ZONE-2 & 3.
3.4.3.1 500 KL capacity Litre 5.58
3.4.3.2 600 KL capacity Litre 5.31
3.4.3.3 700 KL capacity Litre 5.22

PHED REVISED BSR 20223 RCC Reservoirs 41


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.4.3.4 800 KL capacity Litre 5.16


3.4.3.5 900 KL capacity Litre 5.06
3.4.3.6 1000 KL capacity Litre 4.98
3.4.4 Rates for RCC Partially Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC
ZONE-2 & 3.
3.4.4.1 500 KL capacity Litre 5.44
3.4.4.2 600 KL capacity Litre 5.14
3.4.4.3 700 KL capacity Litre 5.02
3.4.4.4 800 KL capacity Litre 4.94
3.4.4.5 900 KL capacity Litre 4.81
3.4.4.6 1000 KL capacity Litre 4.72
3.4.5 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC
ZONE-4
3.4.5.1 500 KL capacity Litre 6.15
3.4.5.2 600 KL capacity Litre 5.89
3.4.5.3 700 KL capacity Litre 5.78
3.4.5.4 800 KL capacity Litre 5.70
3.4.5.5 900 KL capacity Litre 5.51
3.4.5.6 1000 KL capacity Litre 5.36
3.4.6 Rates for RCC Partially Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC
ZONE-4
3.4.6.1 500 KL capacity Litre 5.56
3.4.6.2 600 KL capacity Litre 5.35
3.4.6.3 700 KL capacity Litre 5.22
3.4.6.4 800 KL capacity Litre 5.14
3.4.6.5 900 KL capacity Litre 4.99
3.4.6.6 1000 KL capacity Litre 4.86
3.4.7 Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3

3.4.7.1 500 KL capacity Litre 5.68


3.4.7.2 600 KL capacity Litre 5.56
3.4.7.3 700 KL capacity Litre 5.44
3.4.7.4 800 KL capacity Litre 5.35
3.4.7.5 900 KL capacity Litre 5.23
3.4.7.6 1000 KL capacity Litre 5.15
3.4.8 Rates for RCC Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC ZONE- 2 &
3
3.4.8.1 500 KL capacity Litre 5.56
3.4.8.2 600 KL capacity Litre 5.42
3.4.8.3 700 KL capacity Litre 5.31
3.4.8.4 800 KL capacity Litre 5.24
3.4.8.5 900 KL capacity Litre 5.13
3.4.8.6 1000 KL capacity Litre 5.02
3.4.9 Rates for RCC Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-4

3.4.9.1 500 KL capacity Litre 5.75


3.4.9.2 600 KL capacity Litre 5.66
3.4.9.3 700 KL capacity Litre 5.52
3.4.9.4 800 KL capacity Litre 5.42
3.4.9.5 900 KL capacity Litre 5.30
3.4.9.6 1000 KL capacity Litre 5.21
3.4.10 Rates for RCC Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC ZONE-4

3.4.10.1 500 KL capacity Litre 5.75

PHED REVISED BSR 20223 RCC Reservoirs 42


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.4.10.2 600 KL capacity Litre 5.66


3.4.10.3 700 KL capacity Litre 5.52
3.4.10.4 800 KL capacity Litre 5.42
3.4.10.5 900 KL capacity Litre 5.30
3.4.10.6 1000 KL capacity Litre 5.21
3.5 Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following
capacity as per the Scope of work and Technical specifications, consisting of the following
main activities: -
a) Topographic survey, preparation of site contour plan, conducting SBC test and its
approval from department before construction. Submission and approval of concrete mix
design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation & all RCC Work.
c) All the GLSR shall be provided with adequate plinth protection all around the structure in
a width starting from edge of structure at GL and extending at least up to 1.0m beyond the
vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over
150mm thick compacted soil fill.
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the
roof slab, and 600 mm height of the vertical wall giving.
e) Successful hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the roof Slab.
g) Providing and applying three coats of cement-based paint on the remaining external
surface area of the structure.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder
from top bottom Slab inside container. Providing and fixing water level indicator (Float
type).
i) Providing and fixing MS ladder from ground to top slab with safety cage.
j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of
red oxide.
k) Providing and fixing of 150mm wide water bar for the construction joints in the container.
l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet,
overflow and washout pipe of the reservoir.
m) Inlet, outlet, overflow, washout pipes and valves are not included in this work,
provision for the same shall be taken separately.

3.5.1 Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm

3.5.1.1 50 KL capacity Litre 10.71


3.5.1.2 100 KL capacity Litre 8.09
3.5.1.3 150 KL capacity Litre 6.82
3.5.1.4 200 KL capacity Litre 6.29
3.5.1.5 250 KL capacity Litre 5.75
3.5.1.6 300 KL capacity Litre 5.55
3.5.1.7 400 KL capacity Litre 5.29
3.5.1.8 500 KL capacity Litre 5.14
3.5.2 Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-4 & SBC 18T/sqm
3.5.2.1 50 KL capacity Litre 10.93
3.5.2.2 100 KL capacity Litre 8.21
3.5.2.3 150 KL capacity Litre 6.91
3.5.2.4 200 KL capacity Litre 6.31
3.5.2.5 250 KL capacity Litre 5.78
3.5.2.6 300 KL capacity Litre 5.57
3.5.2.7 400 KL capacity Litre 5.30
3.5.2.8 500 KL capacity Litre 5.14

PHED REVISED BSR 20223 RCC Reservoirs 43


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)

3.6 Providing and fixing double flanged ISI marked GI pipes medium duty (class B ) Steel tube as
per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding
valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc.
providing and fixing with MS clamps at every 3 mtr, jointing materials such as nuts, bolt,
rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber
as per direction of EIC, Technical Specification and Scope of work.

3.6.1 50 mm Mtr 680.00


3.6.2 65 mm Mtr 872.00
3.6.3 80 mm Mtr 901.00
3.6.4 100 mm Mtr 1179.00
3.7 Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000
(amended up to date), as vertical pipes for RCC Reservoirs including specials required such
as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing
materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up
to and from valve chamber as per direction of EIC, Technical Specification and Scope of
work.

3.7.1 100 mm Mtr 2259.00


3.7.2 150 mm Mtr 3249.00
3.7.3 200 mm Mtr 4250.00
3.7.4 250 mm Mtr 5733.00
3.7.5 300 mm Mtr 7314.00
3.7.6 350 mm Mtr 8826.00
3.7.7 400 mm Mtr 10729.00
3.7.8 450 mm Mtr 12686.00
3.7.9 500 mm Mtr 14908.00
3.7.10 600 mm Mtr 19798.00
3.7.11 700 mm Mtr 25541.00
Note: The rates for DI double flanged pipes shall be reduced 5%, if used other than OHSR
pipes.

PHED REVISED BSR 20223 RCC Reservoirs 44


RajKaj Ref No. : 4242943
Chapter 4
Earth work, Road cutting, restoration & trenchless laying
S. No. Description Unit Rate (Rs.)

4.1 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual


means in trenches of required width and gradient for laying and jointing of pipe
line including excavation for sockets, and dressing of sides, ramming of
bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then
returning the soil as required in layers not exceeding 20cm in depth including Cum 200.00
consolidating each deposited layer by ramming, watering etc. and disposal of
surplus excavated soil as directed within a lead of 50 Mtr. including required all
safety provisions etc.:
All kinds of soil
4.2 Add extra for trenches for every additional lift over item no 4.1

4.2.1 Above 1.5 mtr and up to 3.0 mtr. Cum 20.00


4.2.2 Above 3.0 mtr and up to 4.5 mtr. Cum 39.00
4.3 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual
means in trenches of required width and gradient for laying and jointing of pipe
line including excavation for sockets, and dressing of sides, ramming of
bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then
returning the soil as required in layers not exceeding 20cm in depth including
consolidating each deposited layer by ramming, watering etc. and stacking
serviceable material for measurements and disposal of unserviceable material
as directed, with in a lead of 50 Mtr. including all safety provisions required .:

4.3.1 Ordinary rock Cum 365.00


4.3.2 Hard rock (requiring blasting) Cum 546.00
4.3.3 Hard rock(blasting prohibited) Cum 782.00
4.4 Add extra for trenches for every additional lift over item no 4.3
4.4.1 Above 1.5 mtr and up to 3.0 mtr. Cum 37.00
4.4.2 Above 3.0 mtr and up to 4.5 mtr. Cum 73.00
4.5 Dismantling of cement concrete pavement for pipe line and chambers by
mechanical means using pneumatic tools, cutting the peripheral edge by CC
cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at
designated locations and disposal of dismantled materials up to a lead of 1000
meters. Measurement for dismantled trench to be made as per standard Cum 757.00
trench width specified in tender document and no extra payment shall be made
be made for trench width more than specified, re-handling of material/earth to
complete the tasks as per technical specification and scope of work.

PHED REVISED BSR 2023 Earth work, Road cutting, restoration trenchless laying 45
RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

4.6 Dismantling of flexible pavement for pipe line and chambers by mechanical
means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in
volume and stock piling at designated locations and disposal of dismantled
materials up to a lead of 1000 meters. Measurement for dismantled trench to
be made as per standard trench width specified in tender document and no
extra payment shall be made be made for trench width more than specified, re-
handling of material/earth to complete the tasks per technical specification and
scope of work.

4.6.1 Bituminous courses Cum 416.00


4.6.2 Granular courses Cum 296.00
4.7 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6
(1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in
base course complete including all material, labour, machinery, lighting,
guarding for road restoration work in trenches of pipe line and chamber work.
Measurement for CC work to be made as per standard trench width specified Cum 4678.00
in tender document and no extra payment shall be made be made for trench
width more than specified, complete work as per technical specification and
scope of work.

4.8 Providing and laying in position cement concrete in specified grade over
prepared base course complete including finishing, curing, all material, labour,
machinery, lighting, guarding for road restoration work in trenches of pipe line
and chamber work. Measurement for CC work to be made as per standard
trench width specified in tender document and no extra payment shall be made
be made for trench width more than specified, complete work as per technical
specification and scope of work.

4.8.1 M20 grade Nominal Mix


1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal Cum 6162.00
size).

4.8.2 Plain cement concrete pavement of M-30 Grade


Cum 6497.00

PHED REVISED BSR 2023 Earth work, Road cutting, restoration trenchless laying 46
RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

4.9 Removing & Re-fixing of Precast concrete interlocking blocks for laying of pipe
line by manual method, stacking of serviceable & non serviceable material
separately, disposal of dismantled material lead up to 50 mtr. The C.C.
interlocking paving blocks be laid on average 25 mm thick bed of coarse sand
and the joints to be filled with fine sand. Laying procedure on compacted sub
base as defined. Complete job is to be executed as per the directions of
Engineer in charge. The rates to be inclusive of fixing of 70 percent reusable
precast concrete interlocking block and cost of required new precast concrete
interlocking block against damaged, including all lead and lift as per Technical
specifications. (Interlocking block manufactured by fully computerized
automatic stationery hydraulic vibro pressed machine & full computerized
automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting
strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural
colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less
than 3.2 mm)
Note: If existing precast block used more than 70%, than for every 1% use
above 70%, deduction of 1% in cost shall be done for every 1% use above 70%.

4.9.1     60 mm thick. Sqm. 275.00


4.9.2     80 mm thick. Sqm. 298.00
4.9.3     100 mm thick Sqm. 332.00
4.10 Horizontal directional drilling (by trenchless technology) of suitable dia hole
minimum 1.0 mtr below natural ground level in all type of soil under CC/BT
roads and pulling HDPE pipes of dia up to 110 mm, which are available in the
form of a coil including excavation, shoring/ strutting, preparation, maintain
RMT 289.00
the thrust and including, road dismantling, excavation and refilling of drive pit
and exit pit, restoration of road cut as per technical specification and scope of
work, but excluding the cost of pipe line.

4.11 Supply laying and pushing of MS casing pipe of specified thickness approved by
concerned department authority by trenchless method adopting any suitable
technology below ground at required depth under running traffic condition as
per Highway/ Railway standard including carrying out survey work at the job
site for determining underground cable trenches like telephone, cable, water &
sanitary lines and resistivity test for finding the soil strata using necessary
equipments for completion of works, mobilizing of machineries and specialized
crew at the job site complete in all respect, including excavation of driven pit
and exit pit (up to 3 meter depth) with proper protection at these sites with
shoring sheets and ISMB. Providing MS cutting edges for front shield and
constructing thrust bed at designated level. Necessary dewatering and
providing concrete foundation at the base of the driven pit, PVC/Rubber saddle
as per the requirement of Highway/Railway authority, crane for handing of pipe
and any other machinery, tools, and tackles required, construction of
temporary works as per design, drawing and method as per approved by
authority specification and the direction of the Engineer.
Apply corrosion, resistant, protection on inside and outside of casing pipe as
per technical specification.

4.11.1 300 mm Dia 8 mm thick casing pipe. RMT 18353.00


4.11.2 400 mm Dia 8 mm thick casing pipe . RMT 20972.00

PHED REVISED BSR 2023 Earth work, Road cutting, restoration trenchless laying 47
RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

4.11.3 500 mm Dia 8 mm thick casing pipe . RMT 23569.00


4.11.4 600 mm Dia 10 mm thick casing pipe . RMT 30211.00
4.11.5 700 mm Dia 10 mm thick casing pipe . RMT 33457.00
4.12 Removing & Re-fixing of Bricks Kharanja road by manual means for laying of
pipe line, stacking of serviceable & unserviceable material separately, disposal
of dismantled material lead up to 50 mtr. The Bricks interlocking be laid on
average 12 mm thick bed of mud mortar and the joints to be filled with pointing
in cement mortar 1:3. Laying procedure on compacted sub base as defined.
Complete job is to be executed as per the direction of Engineer in charge. The
rates are inclusive of fixing of 80 percent reusable Bricks and cost of required
new First class FPS bricks (min. 10.5 Mpa) in place of damaged bricks, all lead
and lift as per Technical Specifications and direction of Engineer in Charge.
Note: If existing bricks used more than 80%, than for every 1% above 80% use,
deduction of 1% in cost shall be done for every 1% use above 80%.

4.12.1 Horizontal aligned Bricks Sqm. 212.00


4.12.2 Vertical aligned Bricks Sqm. 230.00

PHED REVISED BSR 2023 Earth work, Road cutting, restoration trenchless laying 48
RajKaj Ref No. : 4242943
Chapter 5
Pump sets
Sr. No. Description Unit Rate (Rs.)
5.1 Providing, installation, testing and commissioning of Centrifugal Monoblock
pump set conforming to IS 9079 , 2 pole motor operating at synchronised
speed of 3000 RPM with requisite MOC impeller, priming funnel, cock,
suitable flanges at suction and delivery side. Pump shall have common shaft
for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3
Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be
suitable for working at various discharge and head requirements as per
scope of work. Pump shall be erected on C.C. foundation / cross channels /
RSJ frame block with suitable foundation bolts grouted in C.C. foundation
block etc. complete in all respect as per specification, scope of work and
direction of Engineer in Charge of following power rating, suitable for
prescribed duty conditions mentioned in TD.

5.1.1 Centrifugal Monoblock Pump set (Single Stage)


5.1.1.1 2.2 KW (3.0 HP) Each 34070.00
5.1.1.2 3.7 KW (5.0 HP) Each 43760.00
5.1.1.3 5.5 KW (7.5 HP) Each 55225.00
5.1.1.4 7.5 KW (10 HP) Each 67514.00
5.1.1.5 9.3 KW (12.5 HP) Each 78860.00
5.1.1.6 11.0 KW (15 HP) Each 83148.00
5.1.1.7 15.0 KW (20.0 HP) Each 108825.00
5.1.1.8 18.5 KW (25.0 HP) Each 143629.00
5.1.2 Centrifugal Monoblock Pump set (Double Stage)
5.1.2.1 3.7 KW (5.0 HP) Each 50344.00
5.1.2.2 5.5 KW (7.5 HP) Each 61220.00
5.1.2.3 7.5 KW (10.0 HP) Each 73509.00
5.1.2.4 9.3 KW (12.5 HP) Each 81408.00
5.1.2.5 11.0 KW (15.0 HP) Each 89948.00
5.1.2.6 15.0 KW (20.0 HP) Each 117644.00
Vacuum Pump set (Monoblock)
5.2 Providing, installation, testing and commissioning of Mono block Vacuum
pump set with base plate including C.C. foundation / cross channels / RSJ
frame and foundation bolts etc. complete in all respect as per specification,
scope of work and direction of Engineer in Charge.

5.2.1 0.75 KW (1 HP), single Ph Each 31145.00


5.2.2 2.2 KW (3 HP), three Ph Each 56725.00
Vacuum Pump set (Coupled)
5.3 Providing, installation, testing and commissioning of Vacuum pump set with
horizontal foot mounted TEFC squirrel cage motor working on three phase
50 Hz, 415 Volts +/- 10% with base plate including cost of flexible couplings,
coupling guard etc. complete in all respect as per specification, scope of
work and direction of Engineer in Charge.

5.3.1 3.7 KW (5.0 HP) Each 120824.00


5.3.2 7.5 KW (10.0 HP) Each 148983.00

PHED REVISED BSR 2023 Pump sets 49


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)
5.4 Providing, installation, testing and commissioning of Submerged Centrifugal
Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water
immersed, dry air filled, class "F" insulated TEWC motor integrally mounted
on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/-
10%, along with suitable foundation/ installation device and with 10 mtr
cable, material of construction of impeller SS, casing (volute) CI, wearing ring
SS, etc. complete in all respect as per specification, scope of work and
direction of Engineer in Charge of following power rating, suitable for
prescribed duty conditions mentioned in TD.

5.4.1 15 KW Each 243761.00


5.4.2 18.5 KW Each 300640.00
5.4.3 22 KW Each 357517.00
5.4.4 30 KW Each 487522.00
5.4.5 37 KW Each 598068.00
5.4.6 45 KW Each 633155.00
5.4.7 55 KW Each 813097.00
5.4.8 75 KW Each 902677.00
5.4.9 90 KW Each 1221495.00
5.4.10 110 KW Each 1503260.00
5.4.11 125 KW Each 1648764.00
5.4.12 132 KW Each 1738837.00
5.4.13 160 KW Each 2002177.00
5.4.14 180 KW Each 2127112.00
5.4.15 200 KW Each 2552534.00
5.5 Providing, installation, testing and commissioning of submersible
Monoblock pump set conforming to IS 8034 and 2 pole motor operating at
synchronised speed of speed 3000 RPM, with water proof winding. Pump
shall be suitable for various delivery head and discharge with stainless steel
shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with
water lubricated bearing to accept entire hydraulic thrust. Supply, with cable
guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The
pump set shall be suitable for direct coupling, with suitable suction strainer.
Pump should have suitable discharge out let as per manufacturer's design.
Antithrust stream lined non return valve shall be provided with the pump
and minimum 6 m submersible copper conductor cable in single / double
run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided
with each pump etc. complete in all respect as per specification, scope of
work and direction of Engineer in Charge of following posion : Less than 1.6
mm Variation in thickness: Less than 3.2 mm)

5.5.1 2.2 KW (3.0 HP) Each 35932.00


5.5.2 3.7 KW (5.0 HP) Each 39941.00
5.5.3 5.5 KW (7.5 HP) Each 53789.00
5.5.4 7.5 KW (10 HP) Each 60640.00
5.5.5 9.3 KW (12.5 HP) Each 76487.00
5.5.6 11.0 KW (15 HP) Each 85567.00
5.5.7 15.0 KW (20.0 HP) Each 101747.00

PHED REVISED BSR 2023 Pump sets 50


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)
5.6 Providing, installation, testing and commissioning of submersible
dewatering pump set conforming to relevant IS codes and as per scope of
work and Technical Specifications, with water proof winding. Pump shall be
suitable for various delivery head and discharge with stainless steel shaft,
impeller, pump and motor body. Motor suitable for working on 415 V ± 10%,
3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for
direct coupling, with suitable suction strainer etc. complete in all respect as
per specification, scope of work and direction of Engineer in Charge of
following power rating, suitable for prescribed duty conditions mentioned
in TD.

5.6.1 0.75 KW (1.0 HP) Each 40555.00


5.6.2 1.5 KW (2.0 HP) Each 46501.00
5.6.3 2.2 KW (3.0 HP) Each 80307.00
5.6.4 3.7 KW (5.0 HP ) Each 107500.00
5.7 Providing and fixing at site with necessary packing, Horizontal Centrifugal
Split Casting pumps with 4 pole induction motor operating at synchronised
speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI
casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve,
coupling guard, common base plate, foundation bolts, Cement concrete
foundation etc. complete with all respect as per the specification and scope
of work and direction of Engineer in Charge of following range of duty
conditions.
Note: Duty condition of required pump shall also be mentioned in BoQ.

5.7.1 Discharge 20 to 30 LPS and head 20 to 30 M Each 166357.00


5.7.2 Discharge 20 to 30 LPS and head 31 to 40 M Each 242227.00
5.7.3 Discharge 20 to 30 LPS and head 41 to 50 M Each 285634.00
5.7.4 Discharge 20 to 30 LPS and head 51 to 60 M Each 327309.00
5.7.5 Discharge 20 to 30 LPS and head 61 to 70 M Each 417667.00
5.7.6 Discharge 20 to 30 LPS and head 71 to 80 M Each 417667.00
5.7.7 Discharge 20 to 30 LPS and head 81 to 90 M Each 417667.00
5.7.8 Discharge 31 t0 40 LPS and head 20 to 30 M Each 242227.00
5.7.9 Discharge 31 t0 40 LPS and head 31 to 40 M Each 285634.00
5.7.10 Discharge 31 t0 40 LPS and head 41 to 50 M Each 327309.00
5.7.11 Discharge 31 t0 40 LPS and head 51 to 60 M Each 417667.00
5.7.12 Discharge 31 t0 40 LPS and head 61 to 70 M Each 492515.00
5.7.13 Discharge 31 to 40 LPS and head 71 to 80 M Each 492515.00
5.7.14 Discharge 31 to 40 LPS and head 81 to 90 M Each 574432.00
5.7.15 Discharge 41 t0 50 LPS and head 20 to 30 M Each 285634.00
5.7.16 Discharge 41 t0 50 LPS and head 31 to 40 M Each 417667.00
5.7.17 Discharge 41 t0 50 LPS and head 41 to 50 M Each 417667.00
5.7.18 Discharge 41 t0 50 LPS and head 51 to 60 M Each 492515.00
5.7.19 Discharge 41 t0 50 LPS and head 61 to 70 M Each 574432.00
5.7.20 Discharge 41 to 50 LPS and head 71 to 80 M Each 672571.00
5.7.21 Discharge 41 to 50 LPS and head 81 to 90 M Each 672571.00
5.7.22 Discharge 51 to 60 LPS and head 20 to 30 M Each 327309.00
5.7.23 Discharge 51 to 60 LPS and head 31 to 40 M Each 417667.00
5.7.24 Discharge 51 to 60 LPS and head 41 to 50 M Each 492515.00
5.7.25 Discharge 51 to 60 LPS and head 51 to 60 M Each 574432.00
5.7.26 Discharge 51 to 60 LPS and head 61 to 70 M Each 672571.00
5.7.27 Discharge 51 to 60 LPS and head 71 to 80 M Each 858245.00

PHED REVISED BSR 2023 Pump sets 51


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)
5.7.28 Discharge 51 to 60 LPS and head 81 to 90 M Each 858245.00
5.7.29 Discharge 61 to 70 LPS and head 20 to 30 M Each 327309.00
5.7.30 Discharge 61 to 70 LPS and head 31 to 40 M Each 417667.00
5.7.31 Discharge 61 to 70 LPS and head 41 to 50 M Each 574432.00
5.7.32 Discharge 61 to 70 LPS and head 51 to 60 M Each 672571.00
5.7.33 Discharge 61 to 70 LPS and head 61 to 70 M Each 858245.00
5.7.34 Discharge 61 to 70 LPS and head 71 to 80 M Each 858245.00
5.7.35 Discharge 61 to 70 LPS and head 81 to 90 M Each 990485.00
5.7.36 Discharge 71 to 80 LPS and head 20 to 30 M Each 417667.00
5.7.37 Discharge 71 to 80 LPS and head 31 to 40 M Each 492515.00
5.7.38 Discharge 71 to 80 LPS and head 41 to 50 M Each 672571.00
5.7.39 Discharge 71 to 80 LPS and head 51 to 60 M Each 858245.00
5.7.40 Discharge 71 to 80 LPS and head 61 to 70 M Each 858245.00
5.7.41 Discharge 71 to 80 LPS and head 71 to 80 M Each 990485.00
5.7.42 Discharge 71 to 80 LPS and head 81 to 90 M Each 1159705.00
5.7.43 Discharge 81 to 90 LPS and head 20 to 30 M Each 417667.00
5.7.44 Discharge 81 to 90 LPS and head 31 to 40 M Each 574432.00
5.7.45 Discharge 81 to 90 LPS and head 41 to 50 M Each 672571.00
5.7.46 Discharge 81 to 90 LPS and head 51 to 60 M Each 858245.00
5.7.47 Discharge 81 to 90 LPS and head 61 to 70 M Each 858245.00
5.7.48 Discharge 81 to 90 LPS and head 71 to 80 M Each 1159705.00
5.7.49 Discharge 81 to 90 LPS and head 81 to 90 M Each 1159705.00
5.7.50 Discharge 91 to 100 LPS and head 20 to 30 M Each 492515.00
5.7.51 Discharge 91 to 100 LPS and head 31 to 40 M Each 672571.00
5.7.52 Discharge 91 to 100 LPS and head 41 to 50 M Each 858245.00
5.7.53 Discharge 91 to 100 LPS and head 51 to 60 M Each 858245.00
5.7.54 Discharge 91 to 100 LPS and head 61 to 70 M Each 990485.00
5.7.55 Discharge 91 to 100 LPS and head 71 to 80 M Each 1159705.00
5.7.56 Discharge 91 to 100 LPS and head 81 to 90 M Each 1282285.00
5.7.57 Discharge 101 to 120 LPS and head 20 to 30 M Each 492515.00
5.7.58 Discharge 101 to 120 LPS and head 31 to 40 M Each 672571.00
5.7.59 Discharge 101 to 120 LPS and head 41 to 50 M Each 858245.00
5.7.60 Discharge 101 to 120 LPS and head 51 to 60 M Each 990485.00
5.7.61 Discharge 101 to 120 LPS and head 61 to 70 M Each 1159705.00
5.7.62 Discharge 101to 120 LPS and head 71 to 80 M Each 1159705.00
5.7.63 Discharge 101to 120 LPS and head 81 to 90 M Each 1556866.00
5.7.64 Discharge 121 to 140 LPS and head 20 to 30 M Each 574432.00
5.7.65 Discharge 121 to 140 LPS and head 31 to 40 M Each 858245.00
5.7.66 Discharge 121 to 140 LPS and head 41 to 50 M Each 990485.00
5.7.67 Discharge 121 to 140 LPS and head 51 to 60 M Each 1159705.00
5.7.68 Discharge 121 to 140 LPS and head 61 to 70 M Each 1159705.00
5.7.69 Discharge 121 to 140 LPS and head 71 to 80 M Each 1338395.00
5.7.70 Discharge 121 to 140 LPS and head 81 to 90 M Each 1556866.00
5.7.71 Discharge 141 to 160 LPS and head 20 to 30 M Each 672571.00
5.7.72 Discharge 141 to 160 LPS and head 31 to 40 M Each 858245.00
5.7.73 Discharge 141 to 160 LPS and head 41 to 50 M Each 1159705.00
5.7.74 Discharge 141 to 160 LPS and head 51 to 60 M Each 1282285.00
5.7.75 Discharge 141 to 160 LPS and head 61 to 70 M Each 1556866.00
5.7.76 Discharge 141 to 160 LPS and head 71 to 80 M Each 1556866.00
5.7.77 Discharge 141 to 160 LPS and head 81 to 90 M Each 1855336.00
5.7.78 Discharge 161 to 180 LPS and head 20 to 30 M Each 858245.00
5.7.79 Discharge 161 to 180 LPS and head 31 to 40 M Each 990485.00

PHED REVISED BSR 2023 Pump sets 52


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)
5.7.80 Discharge 161 to 180 LPS and head 41 to 50 M Each 1159705.00
5.7.81 Discharge 161 to 180 LPS and head 51 to 60 M Each 1338395.00
5.7.82 Discharge 161 to 180 LPS and head 61 to 70 M Each 1556866.00
5.7.83 Discharge 161 to 180 LPS and head 71 to 80 M Each 1707880.00
5.7.84 Discharge 161 to 180 LPS and head 81 to 90 M Each 1855336.00
5.7.85 Discharge 181 to 200 LPS and head 20 to 30 M Each 858245.00
5.7.86 Discharge 181 to 200 LPS and head 31 to 40 M Each 1159705.00
5.7.87 Discharge 181 to 200 LPS and head 41 to 50 M Each 1282285.00
5.7.88 Discharge 181 to 200 LPS and head 51 to 60 M Each 1556866.00
5.7.89 Discharge 181 to 200 LPS and head 61 to 70 M Each 1707880.00
5.7.90 Discharge 181 to 200 LPS and head 71 to 80 M Each 1999666.00
5.7.91 Discharge 181 to 200 LPS and head 81 to 90 M Each 2211026.00
5.8 Providing and fixing at site with necessary packing, Horizontal Centrifugal
Split Casting pumps with 4 pole induction motor operating at synchronised
speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI
casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve,
coupling guard, common base plate, foundation bolts, Cement concrete
foundation etc. complete with all respect as per the specification and scope
of work and direction of Engineer in Charge of following range of duty
conditions.
Note: Duty condition of required pump shall also be mentioned in BoQ.

5.8.1 Discharge 201 to 220 LPS and head 20 to 30 M Each 858245.00


5.8.2 Discharge 201 to 220 LPS and head 31 to 40 M Each 1159705.00
5.8.3 Discharge 201 to 220 LPS and head 41 to 50 M Each 1556866.00
5.8.4 Discharge 201 to 220 LPS and head 51 to 60 M Each 1707880.00
5.8.5 Discharge 201 to 220 LPS and head 61 to 70 M Each 1855336.00
5.8.6 Discharge 221 to 240 LPS and head 20 to 30 M Each 990485.00
5.8.7 Discharge 221 to 240 LPS and head 31 to 40 M Each 1282285.00
5.8.8 Discharge 221 to 240 LPS and head 41 to 50 M Each 1556866.00
5.8.9 Discharge 221 to 240 LPS and head 51 to 60 M Each 1855336.00
5.8.10 Discharge 221 to 240 LPS and head 61 to 70 M Each 1999666.00
5.8.11 Discharge 241 to 260 LPS and head 20 to 30 M Each 990485.00
5.8.12 Discharge 241 to 260 LPS and head 31 to 40 M Each 1338395.00
5.8.13 Discharge 241 to 260 LPS and head 41 to 50 M Each 1556866.00
5.8.14 Discharge 241 to 260 LPS and head 51 to 60 M Each 1855336.00
5.8.15 Discharge 241 to 260 LPS and head 61 to 70 M Each 2211026.00
5.8.16 Discharge 261 to 280 LPS and head 20 to 30 M Each 1159705.00
5.8.17 Discharge 261 to 280 LPS and head 31 to 40 M Each 1556866.00
5.8.18 Discharge 261 to 280 LPS and head 41 to 50 M Each 1707880.00
5.8.19 Discharge 261 to 280 LPS and head 51 to 60 M Each 1999666.00
5.8.20 Discharge 261 to 280 LPS and head 61 to 70 M Each 2383025.00
5.8.21 Discharge 281 to 300 LPS and head 20 to 30 M Each 1159705.00
5.8.22 Discharge 281 to 300 LPS and head 31 to 40 M Each 1556866.00
5.8.23 Discharge 281 to 300 LPS and head 41 to 50 M Each 1855336.00
5.8.24 Discharge 281 to 300 LPS and head 51 to 60 M Each 1999666.00
5.8.25 Discharge 281 to 300 LPS and head 61 to 70 M Each 2383025.00
5.8.26 Discharge 301 to 325 LPS and head 20 to 30 M Each 1282285.00
5.8.27 Discharge 301 to 325 LPS and head 31 to 40 M Each 1556866.00
5.8.28 Discharge 301 to 325 LPS and head 41 to 50 M Each 1999666.00
5.8.29 Discharge 301 to 325 LPS and head 51 to 60 M Each 2211026.00
5.8.30 Discharge 301 to 325 LPS and head 61 to 70 M Each 2651461.00

PHED REVISED BSR 2023 Pump sets 53


RajKaj Ref No. : 4242943
Sr. No. Description Unit Rate (Rs.)
5.8.31 Discharge 326 to 350 LPS and head 20 to 30 M Each 1282285.00
5.8.32 Discharge 326 to 350 LPS and head 31 to 40 M Each 1707880.00
5.8.33 Discharge 326 to 350 LPS and head 41 to 50 M Each 1999666.00
5.8.34 Discharge 326 to 350 LPS and head 51 to 60 M Each 2383025.00
5.8.35 Discharge 326 to 350 LPS and head 61 to 70 M Each 2651461.00
5.8.36 Discharge 351 to 400 LPS and head 20 to 30 M Each 1556866.00
5.8.37 Discharge 351 to 400 LPS and head 31 to 40 M Each 1855336.00
5.8.38 Discharge 351 to 400 LPS and head 41 to 50 M Each 2211026.00
5.8.39 Discharge 351 to 400 LPS and head 51 to 60 M Each 2651461.00
5.8.40 Discharge 351 to 400 LPS and head 61 to 70 M Each 2912679.00

PHED REVISED BSR 2023 Pump sets 54


RajKaj Ref No. : 4242943
Chapter 6
Valves and Appurtenances
S. No. Description Unit Rate (Rs.)
6.1 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice
valves straight and pocket less body passage of approved make of following
Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and
of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand
wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge
facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000
(amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied
inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363
and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick .
Sluice valves including all jointing & jointing material, labour, testing and
commissioning along with pipe line as per Technical Specifications and as per
direction of Engineer-in-charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.1.1 Manually Operated CI Sluice valve of Class PN-1.0


6.1.1.1 80 mm HW Each 6301.00
6.1.1.2 100 mm HW Each 8649.00
6.1.1.3 125 mm HW Each 11173.00
6.1.1.4 150 mm HW Each 13595.00
6.1.1.5 200 mm HW Each 22603.00
6.1.1.6 250 mm HW Each 35722.00
6.1.1.7 300 mm HW Each 45382.00
6.1.1.8 350 mm with Gear Each 86838.00
6.1.1.9 400 mm with Gear Each 113457.00
6.1.1.10 450 mm with Gear Each 147665.00
6.1.1.11 500 mm with Gear Each 184884.00
6.1.1.12 600 mm with Gear Each 263170.00
Motorized Sluice Valves with Electric Actuator with integral starter of Class PN
6.1.2
1.0
6.1.2.1 80 mm dia Each 118496.00
6.1.2.2 100 mm dia Each 122294.00
6.1.2.3 125 mm dia Each 126666.00
6.1.2.4 150 mm dia Each 133417.00
6.1.2.5 200 mm dia Each 151343.00
6.1.2.6 250 mm dia Each 171551.00
6.1.2.7 300 mm dia Each 182779.00
6.1.2.8 350 mm dia Each 222494.00
6.1.2.9 400 mm dia Each 250954.00
6.1.2.10 450 mm dia Each 291680.00
6.1.2.11 500 mm dia Each 342759.00
6.1.2.12 600 mm dia. Each 424560.00
6.2 Providing, lowering, laying, aligning, fixing in position CI D/F short body
pattern type butterfly valves having body, disc and end cover in graded cast iron
generally conforming to (IS13095/1991amended up to date), synthetic rubber
faced ring secured on disc by retaining ring with SS steel screw stub shaft of SS
riding in Teflon bearing including C.C. foundation/ structural steel support,
material, labour, testing along with pipe line and commissioning as per
Technical Specifications and as per direction of Engineer in charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work

6.2.1 Manually Operated Butterfly Valve PN-1.0


6.2.1.1 100 mm dia ( With lever operated) Each 12762.00

PHED REVISED BSR 2023 Valves and Appurtenances 55


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.2.1.2 125 mm dia ( With lever operated) Each 17582.00
6.2.1.3 150 mm dia ( With lever operated) Each 21877.00
6.2.1.4 200 mm dia (With Gear Operated) Each 32923.00
6.2.1.5 250 mm dia (With Gear Operated) Each 41797.00
6.2.1.6 300 mm dia (With Gear Operated) Each 52123.00
6.2.1.7 350 mm dia (With Gear Operated) Each 65006.00
6.2.1.8 400 mm dia (With Gear Operated) Each 84260.00
6.2.1.9 450 mm dia (With Gear Operated) Each 101611.00
6.2.1.10 500 mm dia (With Gear Operated) Each 126540.00
6.2.1.11 600 mm dia (With Gear Operated) Each 171852.00
6.2.1.12 700 mm dia (With Gear Operated) Each 234240.00
6.2.1.13 800 mm dia (With Gear Operated) Each 334083.00
6.2.1.14 900 mm dia (With Gear Operated) Each 430488.00
6.2.1.15 1000 mm dia (With Gear Operated) Each 556415.00
6.3 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing
type Non Return Valves (NRV) of approved make of following Pressure rating &
dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of
following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200.
Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per
IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover
and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/
Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron /
SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket
EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion
rubber of black EPDM 6mm thick. Suitable support structure as per directions of
EIC including jointing & jointing material, labour, testing and commissioning along
with pipeline as per Technical Specification & as per direction of Engineer-in-
charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.3.1 Class PN 1.0


6.3.1.1 80 mm dia Each 6219.00
6.3.1.2 100 mm dia Each 7973.00
6.3.1.3 125 mm dia Each 10452.00
6.3.1.4 150 mm dia Each 13107.00
6.3.1.5 200 mm dia Each 22519.00
6.3.1.6 250 mm dia Each 36559.00
6.3.1.7 300 mm dia Each 50411.00
6.3.1.8 350 mm dia Each 88822.00
6.3.1.9 400 mm dia Each 127052.00
6.3.1.10 450 mm dia Each 161074.00
6.3.1.11 500 mm dia Each 232130.00
6.3.1.12 600 mm dia Each 344059.00

PHED REVISED BSR 2023 Valves and Appurtenances 56


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.4 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged Dual
plate check valve of approved make of following Pressure rating & dia complete,
as per API: 594/ API: 598 and of following specifications: Body & Cover of Grey
cast iron of IS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR
(food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594
,Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water)
applied on body & cover inside and outside . Shaft/Stop Pin of SS- AISI- 304/410 ,
Hinge SS AISI 316/304 / CS ,Spring SS AISI 316/304 , Bonnet Gasket EPDM ,Bush-
Brass with EPDM/NBR "O "ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367
(galvanised steel) ,Insertion rubber of black EPDM 6mm thick . Suitable support
structure as per directions of EIC including jointing & jointing material, labour,
testing and commissioning along with pipeline as per Technical Specification & as
per direction of Engineer-in-charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.4.1 Class PN 1.0


6.4.1.1 80 mm dia Each 6055.00
6.4.1.2 100 mm dia Each 7694.00
6.4.1.3 125 mm dia Each 9640.00
6.4.1.4 150 mm dia Each 12719.00
6.4.1.5 200 mm dia Each 21892.00
6.4.1.6 250 mm dia Each 34618.00
6.4.1.7 300 mm dia Each 46370.00
6.4.1.8 350 mm dia Each 61573.00
6.4.1.9 400 mm dia Each 88371.00
6.4.1.10 450 mm dia Each 108734.00
6.4.1.11 500 mm dia Each 116496.00
6.4.1.12 600 mm dia Each 153809.00
6.5 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air
Valve Flanged/ Screwed type of approved makes for following pressure rating &
dia complete, confirming to IS: 14845-2000 (amended up to date) and of following
specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float -
Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin
bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418
or Screwed type shall have external pipe threads conforming to IS 554 Fasteners -
CS Epoxy paint inside outside of food grade safe for drinking water ,Valves
including all material, labour, testing and commissioning as per Technical
Specifications and as per direction of Engineer in charge.
Note: Rates are exclusive of connecting tee, pipe piece and earth work.

6.5.1 Class PN 1.0


6.5.1.1 15 mm S-1 Type Each 2423.00
6.5.1.2 25 mm S-1 Type Each 3145.00
6.5.1.3 40 mm S-1 Type Each 3912.00
6.5.1.4 50 mm S-2 Type Each 4590.00
6.5.2 Class PN 1.6
6.5.2.1 15 mm S-1 Type Each 2587.00
6.5.2.2 25 mm S-1 Type Each 3296.00
6.5.2.3 40 mm S-1 Type Each 4046.00
6.5.2.4 50 mm S-2 Type Each 4811.00

PHED REVISED BSR 2023 Valves and Appurtenances 57


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.6 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double
Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for
following pressure rating & dia complete, confirming to IS: 14845-2000 (amended
up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron
as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide-
HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and
face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint
inside outside of food grade safe for drinking water ,Valves including all material,
labour, testing and commissioning as per Technical Specifications and as per
direction of Engineer in charge.
Note: Rates are exclusive of connecting tee, pipe piece and earth work.
6.6.1 Class PN 1.0
6.6.1.1 40 mm Each 11616.00
6.6.1.2 50 mm Each 13234.00
6.6.1.3 80 mm Each 17112.00
6.6.1.4 100 mm Each 23250.00
6.6.1.5 150 mm Each 48594.00
6.6.1.6 200 mm Each 74101.00
6.6.2 Class PN 1.6
6.6.2.1 40 mm Each 12431.00
6.6.2.2 50 mm Each 14126.00
6.6.2.3 80 mm Each 17858.00
6.6.2.4 100 mm Each 24184.00
6.6.2.5 150 mm Each 51118.00
6.6.2.6 200 mm Each 77713.00
6.7 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body
Flanged End Tamper proof Kinetic Air Valve of approved makes of following
pressure rating and dia and as per following specifications: Governing standard -
AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low
pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200
,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring &
Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges
as per IS/ BS, Drilled as per IS:1538. Epoxy paint (Non-Toxic & suitable for drinking
water) applied on body & cover inside and outside Fasteners - CS/ Galvanised
steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI
metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to
date) PN 1.0 ratings Valves including all material, labour, testing and
commissioning as per Technical Specifications and as per direction of Engineer in
charge.
Note: Rates are exclusive of connecting tee, pipe piece and earth work.
6.7.1 Class PN 1.0
6.7.1.1 40 mm Each 12811.00
6.7.1.2 50 mm Each 14038.00
6.7.1.3 80 mm Each 17304.00
6.7.1.4 100 mm Each 23227.00
6.7.1.5 150 mm Each 39551.00
6.7.1.6 200 mm Each 57592.00

PHED REVISED BSR 2023 Valves and Appurtenances 58


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.8 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F
Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble
tight), straight and pocket less body passage of approved make of following class &
dia complete confirming to BS-EN-1171/ AWWA C-509 and of following
specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per
DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-
1985 and subsequent revisions, Wedge of same material as body & shall
vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to
face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din
3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/
Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum
thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt
confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black
EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves
including all jointing & jointing material, labour, testing and commissioning along
with pipe line as per Technical Specifications and as per direction of Engineer-in-
charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.8.1 Manually Operated Resilient Seated Sluice Valves of Class PN 1.6


6.8.1.1 80 mm dia Each 9137.00
6.8.1.2 100 mm dia Each 11554.00
6.8.1.3 125 mm dia Each 17087.00
6.8.1.4 150 mm dia Each 19109.00
6.8.1.5 200 mm dia Each 29396.00
6.8.1.6 250 mm dia Each 48781.00
6.8.1.7 300 mm dia Each 62128.00
6.8.1.8 350 mm dia Each 116573.00
6.8.1.9 400 mm dia Each 152675.00
6.8.1.10 450 mm dia Each 203807.00
6.8.1.11 500 mm dia Each 262134.00
6.8.1.12 600 mm dia. Each 385252.00
6.8.1.13 700 mm dia. With Gear Each 717167.00
6.8.1.14 800 mm dia. With Gear Each 1013527.00
6.8.1.15 900 mm dia. With Gear Each 1400382.00
6.8.1.16 1000 mm dia. With Gear Each 1834316.00
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN
6.8.2
1.0
6.8.2.1 80 mm dia Each 120451.00
6.8.2.2 100 mm dia Each 123908.00
6.8.2.3 125 mm dia Each 131735.00
6.8.2.4 150 mm dia Each 136800.00
6.8.2.5 200 mm dia Each 155060.00
6.8.2.6 250 mm dia Each 177836.00
6.8.2.7 300 mm dia Each 194973.00
6.8.2.8 350 mm dia Each 255519.00
6.8.2.9 400 mm dia Each 289218.00
6.8.2.10 450 mm dia Each 360051.00
6.8.2.11 500 mm dia Each 423608.00
6.8.2.12 600 mm dia. Each 526563.00
Motorized Sluice Valves with Electric Actuator and integral starter of Class PN
6.8.3
1.6
6.8.3.1 80 mm dia Each 121297.00
6.8.3.2 100 mm dia Each 124743.00
6.8.3.3 125 mm dia Each 132962.00
6.8.3.4 150 mm dia Each 139701.00
6.8.3.5 200 mm dia Each 155351.00
6.8.3.6 250 mm dia Each 177684.00

PHED REVISED BSR 2023 Valves and Appurtenances 59


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.8.3.7 300 mm dia Each 193924.00
6.8.3.8 350 mm dia Each 256125.00
6.8.3.9 400 mm dia Each 287479.00
6.8.3.10 450 mm dia Each 354680.00
6.8.3.11 500 mm dia Each 414750.00
6.8.3.12 600 mm dia. Each 521593.00
6.9 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated
(soft seated) short body pattern type double eccentric Butterfly valves of
approved make of following class & dia complete confirming to BS EN 593/ BS
5155/ IS 13095/1991 amended up to date and of following specifications: Body,
disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or
GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and
subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095
Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy
(Non-Toxic & suitable for drinking water) coated with minimum thickness of 250
micron applied on both body and disc inside and outside. Disc seal ring of EPDM/
Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS-
AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring
seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion
rubber of black EPDM 6mm thick. Suitable support structure as per directions of
EIC including jointing & jointing material, labour, testing and commissioning along
with pipeline as per Technical Specification & as per direction of Engineer-in-
charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.9.1 Class PN 1.6, Manually Operated with Gear


6.9.1.1 100 mm dia Each 50005.00
6.9.1.2 150 mm dia Each 57538.00
6.9.1.3 200 mm dia Each 59837.00
6.9.1.4 250 mm dia Each 66241.00
6.9.1.5 300 mm dia Each 74691.00
6.9.1.6 350 mm dia Each 93544.00
6.9.1.7 400 mm dia Each 123339.00
6.9.1.8 450 mm dia Each 156591.00
6.9.1.9 500 mm dia Each 196252.00
6.9.1.10 600 mm dia Each 243762.00
6.9.1.11 700 mm dia Each 333978.00
6.9.1.12 800 mm dia. Each 444787.00
6.9.1.13 900 mm dia. Each 576157.00
6.9.1.14 1000 mm dia. Each 750935.00
6.9.2 Class PN 1.0, Motorised Operated
6.9.2.1 200 mm dia Each 157707.00
6.9.2.2 250 mm dia Each 172589.00
6.9.2.3 300 mm dia Each 193228.00
6.9.2.4 350 mm dia Each 209909.00
6.9.2.5 400 mm dia Each 240346.00
6.9.2.6 450 mm dia Each 276502.00
6.9.2.7 500 mm dia Each 299107.00
6.9.2.8 600 mm dia Each 346857.00
6.9.2.9 700 mm dia Each 451694.00
6.9.2.10 800 mm dia. Each 584442.00
6.9.2.11 900 mm dia. Each 697907.00
6.9.2.12 1000 mm dia. Each 885557.00
6.9.3 Class PN 1.6, Motorised Operated
6.9.3.1 200 mm dia Each 160812.00
6.9.3.2 250 mm dia Each 176267.00
6.9.3.3 300 mm dia Each 198850.00

PHED REVISED BSR 2023 Valves and Appurtenances 60


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.9.3.4 350 mm dia Each 216062.00
6.9.3.5 400 mm dia Each 247397.00
6.9.3.6 450 mm dia Each 284669.00
6.9.3.7 500 mm dia Each 313492.00
6.9.3.8 600 mm dia Each 368293.00
6.9.3.9 700 mm dia. Each 477060.00
6.9.3.10 800 mm dia. Each 618656.00
6.9.3.11 900 mm dia. Each 744804.00
6.9.3.12 1000 mm dia. Each 938849.00
6.10 Providing, lowering, aligning, fixing in position in pipe line, DI resilient seated (soft
seated) Concentric Wafer type, Butterfly valves of approved make of following
Pressure rating & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991
amended up to date and of following specifications: Body- Ductile cast iron of
grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or
equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc
- DI (same as body material) / CS, Face to face dimensions as per DIN 3202 F4/ IS
13095 , Flanges Drilled as per IS:1538 ,Electrostatic Epoxy Powder(EP-P) / Fusion
Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum
thickness of 250 micron applied on both body and disc inside and outside . Liner &
Disc seal - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410/420 & shaft
bearings- bronze/ PTET or Teflon with EPDM/NBR "O "ring seal , Nut-Bolt
confirming to IS:1363 and IS: 1367/ Galvanised steel, Insertion rubber of black
EPDM 6mm thick ,Suitable support structure as per directions of EIC including
jointing & jointing material, labour, testing and commissioning along with pipeline
as per Technical Specification & as per direction of Engineer-in-charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.10.1 Class PN 1.6, Wafer Type


6.10.1.1 80 mm (Lever Operated) Each 10585.00
6.10.1.2 100 mm (Lever Operated) Each 12783.00
6.10.1.3 125 mm (Lever Operated Each 21548.00
6.10.1.4 150 mm (Lever Operated) Each 23397.00
6.10.1.5 200 mm (with Gear) Each 35284.00
6.10.1.6 250 mm (with Gear) Each 45556.00
6.10.1.7 300 mm (with Gear) Each 50571.00
6.11 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated
(soft seated) Swing type Non Return Valve of approved make of following
Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004
(amended up to date) and of following specifications: Body, Bonnet & disc of
Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per
IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,
Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538.
Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for
drinking water) coated with minimum thickness of 250 micron applied on body,
cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade
quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI
316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal Nut-
Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black
EPDM 6mm thick. Suitable support structure as per directions of EIC including
jointing & jointing material, labour, testing and commissioning along with pipeline
as per Technical Specification & as per direction of Engineer-in-charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.11.1 Class PN 1.6


6.11.1.1 80 mm dia Each 9458.00
6.11.1.2 100 mm dia Each 12598.00

PHED REVISED BSR 2023 Valves and Appurtenances 61


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.11.1.3 125 mm dia Each 17774.00
6.11.1.4 150 mm dia Each 21821.00
6.11.1.5 200 mm dia Each 37011.00
6.11.1.6 250 mm dia Each 55783.00
6.11.1.7 300 mm dia Each 76588.00
6.11.1.8 350 mm dia Each 128442.00
6.11.1.9 400 mm dia Each 165735.00
6.11.1.10 450 mm dia Each 214721.00
6.11.1.11 500 mm dia Each 256135.00
6.11.1.12 600 mm dia Each 337993.00
6.12 Providing, lowering, aligning, fixing in position in pipe line, DI double flanged
resilient seated Dual plate check valve of approved make of following Pressure
rating & dia complete, as per API: 594/ API: 598 and of following specifications:
Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR
SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and
subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions
as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) /
Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with
minimum thickness of 250 micron applied on body and cover inside and outside .
Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring
of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI
316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal, Nut-Bolt
confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black
EPDM 6mm thick .Suitable support structure as per directions of EIC including
jointing & jointing material, labour, testing and commissioning along with pipeline
as per Technical Specification & as per direction of Engineer-in-charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.12.1 Class PN 1.6


6.12.1.1 80 mm dia Each 11584.00
6.12.1.2 100 mm dia Each 13362.00
6.12.1.3 125 mm dia Each 14224.00
6.12.1.4 150 mm dia Each 20940.00
6.12.1.5 200 mm dia Each 36510.00
6.12.1.6 250 mm dia Each 55072.00
6.12.1.7 300 mm dia Each 77472.00
6.12.1.8 350 mm dia Each 83217.00
6.12.1.9 400 mm dia Each 107465.00
6.12.1.10 450 mm dia Each 128757.00
6.12.1.11 500 mm dia Each 151597.00

PHED REVISED BSR 2023 Valves and Appurtenances 62


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.13 Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body
Flanged End Tamper proof Kinetic Air Valve of approved makes of following
pressure rating and dia and as per following specifications: Governing standard -
AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low
pressure cover, Cowl and Joint support ring - Ductile cast iron of grade
GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball &
HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP
orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538.
Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for
drinking water) coated with minimum thickness of 250 micron applied on body &
cover inside and outside fasteners - CS/ Galvanised steel, Outlet of big orifice will
have a screen to prevent Tamper of float, with DI metal seated D/F Non rising
stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.6 ratings Valves
including all material, labour, testing and commissioning as per Technical
Specifications and as per direction of Engineer in charge.
Note: Rates are exclusive of connecting tee, pipe piece and earth work.

6.13.1 Class PN 1.6


6.13.1.1 40 mm dia Each 13021.00
6.13.1.2 50 mm dia Each 13499.00
6.13.1.3 80 mm dia Each 17236.00
6.13.1.4 100 mm dia Each 23449.00
6.13.1.5 150 mm dia Each 40162.00
6.13.1.6 200 mm dia Each 55019.00
6.14 Providing, lowering, aligning, fixing in position and Jointing in pipe line,
combination Air Release Valve Kinetic type with single chamber housed Double
orifice and have 3 functions, large Air exhaust, small Air venting and large air
intake during vacuum of pipeline of approved makes of following pressure rating
and dia and as per following specifications: Governing standard - AWWA C512
,Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or
GR SG-400/12 as per IS 1865,Float & internal trim: AISI 304 stainless Steel, Seat
ring & Gasket - EPDM/NBR Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-
P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with
minimum thickness of 250 micron applied on body & cover inside and outside
Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent
Tamper of float, Big orifice size should be equal or larger than the inlet flange bore,
for fully comply with AWWA C512. ), Valve including all material, labour,
testing and commissioning as per Technical Specifications and as per direction of
Engineer in charge.
Note: Rates are exclusive of connecting tee, pipe piece and earth work.

6.14.1 Class PN 1.6


6.14.1.1 50 mm dia Each 18064.00
6.14.1.2 80 mm dia Each 23209.00
6.14.1.3 100 mm dia Each 31051.00
6.14.1.4 150 mm dia Each 49563.00
6.14.1.5 200 mm dia Each 62215.00

PHED REVISED BSR 2023 Valves and Appurtenances 63


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control
Valve of approved make of following Pressure rating & dia complete and of
following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per
DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301,
Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel
AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318-
LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318-
LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to
6.15 Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5,
Class 150 and Class 300/ EN-1092-2. Insertion rubber of black EPDM 6mm thick
,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for
drinking water) coated with minimum thickness of 250 micron applied both inside
and outside . Suitable support structure as per directions of EIC including jointing
& jointing material, labour, testing and commissioning as per Technical
Specification & as per direction of Engineer-In- Charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

6.15.1 Plunger Type Flow Control Valve


6.15.1.1 80 mm dia Each 338036.00
6.15.1.2 100mm dia Each 368438.00
6.15.1.3 125 mm dia Each 410651.00
6.15.1.4 150mm dia Each 450548.00
6.15.1.5 200mm dia Each 552018.00
6.15.1.6 250mm dia Each 645671.00
6.15.1.7 300mm dia Each 788276.00
6.15.1.8 350mm dia Each 829368.00
6.15.1.9 400mm dia Each 1147092.00
6.15.1.10 450mm dia Each 1208964.00
6.15.1.11 500mm dia Each 1574717.00
6.15.1.12 600mm dia Each 2002512.00
6.15.1.13 700mm dia Each 3260283.00
6.15.1.14 800mm dia Each 4183868.00
6.15.1.15 900mm dia Each 5751324.00
6.15.1.16 1000mm dia Each 5967713.00
6.16 Providing, lowering, aligning and fixing in position DI D/F Diaphragm type Pressure
Reducing / Flow Control Valve of approved make of following Pressure rating & dia
complete and of following specifications: Body & Bonnet - Ductile cast iron of grade
GGG40/GGG50 as per DIN 1693 or ASTM A 536, Diaphragm and Resilient seal disc -
Flexible, non-wicking nylon fabric reinforced synthetic elastomer -Buna-N / EPDM
(FDA / WRAS approved), Body Seat Ring - Cast stainless steel ASTM- A 351 GR. CF8M /
AISI- 316, raised, replaceable inline & onsite Stem - Stainless Steel, AISI-316/410,
raised, replaceable inline & onsite Spring & Bearing bush- Stainless Steel, AISI-316
,Disc guide, disc retainer & diaphragm washer - Stainless Steel, AISI-304/ 316/Bronze
,Seal- EPDM/ NBR ,Pilot Body- Stainless Steel, AISI-304/ CF8 or Brass Tubing - Stainless
Steel, AISI-304 / Copper ,Solenoid Valve- Stainless Steel, AISI-316 ,Throttling plug -
Stainless Steel, AISI-304, Nut- Bolts - SS Face to Face- as per ANSI B 16.1/ EN 558-1 and
Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.
insertion rubber of black EPDM 6mm thick Electrostatic Epoxy Powder(EP-P) / Fusion
Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum
thickness of 250 micron applied both inside and outside. Suitable support structure as
per directions of EIC including jointing & jointing material, labour, testing and
commissioning as per Technical Specification & as per direction of Engineer-In- Charge.
Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

Pilot operated SCADA Compatible Diaphragm Type Pressure Reducing Valves


6.16.1
(Class PN 1.6)
6.16.1.1 80 mm dia Each 114654.00

PHED REVISED BSR 2023 Valves and Appurtenances 64


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.16.1.2 100 mm dia Each 124190.00
6.16.1.3 125 mm dia Each 143136.00
6.16.1.4 150 mm dia Each 169176.00
6.16.1.5 200 mm dia Each 209789.00
6.16.1.6 250 mm dia Each 285584.00
6.16.1.7 300 mm dia Each 376769.00
6.16.1.8 350 mm dia Each 523698.00
6.16.1.9 400 mm dia Each 667522.00
6.16.1.10 450 mm dia Each 896769.00
6.16.1.11 500 mm dia Each 1228036.00
6.16.1.12 600 mm dia Each 1645367.00
Diaphragm Type Flow Control Valve With Electrical Actuator suitable for SCADA
6.16.2
(PN 1.6 )
6.16.2.1 80 mm dia Each 108336.00
6.16.2.2 100 mm dia Each 119999.00
6.16.2.3 125 mm dia Each 140144.00
6.16.2.4 150 mm dia Each 155111.00
6.16.2.5 200 mm dia Each 181481.00
6.16.2.6 250 mm dia Each 260901.00
6.16.2.7 300 mm dia Each 362386.00
6.16.2.8 350 mm dia Each 495525.00
6.16.2.9 400 mm dia Each 879489.00
6.16.2.10 450 mm dia Each 1214394.00
6.16.2.11 500 mm dia Each 1460385.00
6.16.2.12 600 mm dia Each 2138027.00
Dismantling/ Expansion Joints
6.17 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling
joint (Suitable for Sluice valves etc.) as per IS specifications complete of the
following sizes including all jointing material, cost of all labour, testing and
commissioning Technical Specifications and as per direction of Engineer. Class PN
1.0

6.17.1 80 mm dia Each 3149.00


6.17.2 100 mm dia. Each 3666.00
6.17.3 125 mm dia. Each 4792.00
6.17.4 150 mm dia. Each 5758.00
6.17.5 200 mm dia. Each 8564.00
6.17.6 250 mm dia. Each 11729.00
6.17.7 300 mm dia. Each 14024.00
6.17.8 350 mm dia. Each 18247.00
6.17.9 400 mm dia. Each 24715.00
6.17.10 450 mm dia. Each 28756.00
6.17.11 500 mm dia. Each 34191.00
6.17.12 600 mm dia. Each 48304.00
6.18 Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling
joint (Fabricated Steel) as per IS specifications complete of the following
sizes including all jointing material, cost of all labour, testing and
commissioning Technical Specifications and as per direction of Engineer.

6.18.1 80 mm dia Each 4234.00


6.18.2 100 mm dia. Each 5131.00
6.18.3 125 mm dia. Each 6799.00
6.18.4 150 mm dia. Each 9584.00
6.18.5 200 mm dia. Each 11816.00
6.18.6 250 mm dia. Each 15313.00
6.18.7 300 mm dia. Each 19121.00

PHED REVISED BSR 2023 Valves and Appurtenances 65


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
6.18.8 350 mm dia. Each 26798.00
6.18.9 400 mm dia. Each 35805.00
6.18.10 450 mm dia. Each 42109.00
6.18.11 500 mm dia. Each 51137.00
6.18.12 600 mm dia. Each 65372.00
6.18.13 700 mm dia. Each 92761.00
6.18.14 800 mm dia. Each 119543.00
6.18.15 900 mm dia. Each 154893.00
6.18.16 1000 mm dia. Each 183534.00
6.19 Providing, installation, testing and commissioning of following Stain less steel AISI
304 Expansion bellows of 10/16 bar rating with tie rods as per technical
specifications and layout drawings including jointing material like nuts, bolts,
rubber gaskets etc. complete in all respect as per technical specification and as per
direction of Engineer.
6.19.1 80 mm dia. Each 7259.00
6.19.2 100 mm dia. Each 8339.00
6.19.3 125 mm dia. Each 9615.00
6.19.4 150 mm dia. Each 11445.00
6.19.5 200 mm dia. Each 12954.00
6.19.6 250 mm dia. Each 15849.00
6.19.7 300 mm dia. Each 19614.00
6.19.8 350 mm dia. Each 23698.00
6.19.9 400 mm dia. Each 30524.00
6.19.10 450 mm dia. Each 35941.00
6.19.11 500 mm dia. Each 57172.00
6.19.12 600 mm dia. Each 69331.00
6.19.13 700 mm dia. Each 94586.00
6.19.14 800 mm dia. Each 118282.00
6.19.15 900 mm dia. Each 140937.00
6.19.16 1000 mm dia. Each 184665.00
Removing of existing CI/ DI Double flange sluice valves, non return valves, butter
fly valves etc. in existing Distribution/ Rising Main/ Transmission Main pipe line of
following sizes, works include de-jointing of valve, dewatering, taking it out of the
pit with adequate safety arrangement at site and then refill the pit from excavated
6.20 sand by ramming it at sides of pipe & up to ground level. Work shall be done as per
specification, scope of work and direction of Engineer-in-charge. All old material
shall be removed safely & all old material shall be deposited in Divisional Store.
Note: Rates are exclusive of earth work and road cutting.

6.20.1 80 mm Each 479.00


6.20.2 100 mm Each 520.00
6.20.3 125 mm Each 646.00
6.20.4 150 mm Each 688.00
6.20.5 200 mm Each 750.00
6.20.6 250 mm Each 959.00
6.20.7 300 mm Each 1413.00
6.20.8 350 mm Each 1648.00
6.20.9 400 mm Each 1850.00
6.20.10 450 mm Each 2513.00
6.20.11 500 mm Each 2774.00
6.20.12 600 mm Each 3077.00

PHED REVISED BSR 2023 Valves and Appurtenances 66


RajKaj Ref No. : 4242943
Chapter 7
DOL / Star delta starter type LT panels
S. No. Description Unit Rate (Rs.)
7.1 SITC DOL Starter type LT Panel of following rating, all switchgears are of
PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar
1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame
including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet,
Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock,
Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing
Material ) etc. complete as per Technical Specifications and as per
direction of Engineer-In-Charge.

7.1.1 DOL STARTER 2.2 KW (3 HP)- : For 2 motors (1 W+ 1S) Each 49356.00
I/C - MCB 25A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-
500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A )
(1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights
( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP
10 KA C Curve (3) and
O/G- MCB 16A ,TP, 10 KA, C Curve (2), Power Cont 9A TP AC3 Duty(2), 2
NO+2 NC Aux. Block(2), Thermal Overload Relay (4-6A )(2), Control MCB
6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights
(Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1
)(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty
MPP Type 2 Kvar (2)
7.1.2 DOL STARTER 3.7KW (5 HP ) - : For 2 motors (1 W+ 1S) Each 50413.00
I/C - MCB 32A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-
500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A )
(1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights
( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP
10 KA C Curve (3) and
O/G- MCB 25A ,TP, 10 KA, C Curve (2), Power Cont 12A TP AC3 Duty(2),
2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control
MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating
Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green -
1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty
MPP Type 2 Kvar (2)

7.1.3 DOL STARTER 5.5 KW (7.5HP) - : For 2 motors (1 W+ 1S) Each 51448.00
I/C - MCB 40A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-
500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A )
(1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights
( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP
10 KA C Curve (3) and
O/G- MCB 25A ,TP, 10 KA, C Curve (2), Power Cont 12A TP AC3 Duty(2),
2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control
MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating
Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green -
1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty
MPP Type 2 Kvar (2)

PHED REVISED BSR 2023 DOL Star delta starter type LT panels 67
RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
7.2 SITC STAR DELTA Starter type LT Panel of following rating: all
switchgears are of PHED approved makes, CRCA sheet of Panel enclosure
is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated
with angle frame including other ancillaries ( Insulators, Acrylic Sheet ,
Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb
Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle
& Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with
Colour coated heat shrinkage sleeves complete as per Technical
Specifications and as per direction of Engineer-In-Charge.

7.2.1 STAR DELTA STARTER 7.5 KW (10.0 HP) - : For 2 motors (1 W+ Each 65077.00
1S)
I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-
500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A )
(1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights
( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP
10 KA C Curve (3) and
O/G- MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2),
2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control
MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating
Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green -
1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty
MPP Type 5Kvar (2), S/D Timer(2)

7.2.2 STAR DELTA STARTER 9.3 KW (12.5 HP) - : For 2 motors (1 W+ Each 66938.00
1S)
I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-
500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A )
(1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights
( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP
10 KA C Curve (3) and
O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2),
2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control
MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating
Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green -
1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty
MPP Type 5Kvar (2), S/D Timer(2)

7.2.3 STAR DELTA STARTER 11.0 KW (15.0 HP) - : For 2 motors (1 W+ Each 70561.00
1S)
I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-
500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A )
(1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights
( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP
10 KA C Curve (3) and
O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2),
2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control
MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating
Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green -
1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty
MPP Type 7.5Kvar (2), S/D Timer(2)

PHED REVISED BSR 2023 DOL Star delta starter type LT panels 68
RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
7.2.4 STAR DELTA STARTER 15.0 KW (20.0 HP) : For 2 motors (1 W+ Each 99226.00
1S)
I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit
Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog
Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog
Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A
CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights (
Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)
and
O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit
Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2),
Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve
(2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1,
Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1
Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D
Timer(2)
7.2.5 STAR DELTA STARTER 18.5 KW (25.0 HP) - : For 2 motors (1 W+ Each 108534.00
1S)
I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit
Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog
Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog
Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A
CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights (
Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and
O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short
Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux.
Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA
C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green -
1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch
1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2),
S/D Timer(2)

7.2.6 STAR DELTA STARTER 22.0 KW (30.0 HP) - : For 2 motors (1 W+ Each 122057.00
1S)
I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit
Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog
Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog
Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A
CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights (
Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)
and
O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short
Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux.
Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KA
C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green -
1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch
1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2),
S/D Timer(2)

PHED REVISED BSR 2023 DOL Star delta starter type LT panels 69
RajKaj Ref No. : 4242943
Chapter 8

Construction of pump house and boundary wall


S. No. Description
Unit Rate (Rs.)
8.1 Construction of Pump house of brick/ stone masonry of required size
suitable for installation of maximum 4 no. Monoblock pump sets as per
approved GA drawing, scope of work and technical specification complete
work in all respect including electrical works for lighting and fans, rain sqm 20251.00
water drainage. The plinth area of pump house shall be area of
measurement.
8.2 Construction of boundary wall of Brick/ stone masonry as per enclosed GA
drawing, scope of work and technical specifications complete work in all
respect. Brief details of boundary wall parameter is as below:
1. Depth of foundation- 900 mm.
2. PCC in M-10, width -900 mm and thickness 100 mm,
3. Stone masonry in CM: 1:6 section of foundation above PCC, 600
mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)
4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650
mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. RMT 5820.00
5. Cement mortar pointing on Stone masonry and cement mortar plaster
20 mm thick on brick masonry in CM 1:6.
6. Expansion joint shall be on every 30 mtr.
7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be
provided.
8. Pillar for main gate 350x350 mm in size is part of boundary wall.
9. Cement paint of approved colour in 3 coat shall be done.

8.3 Providing and fixing steel, gate, grating and grills made of angles, tees,
square bars, flats or black pipe with hold fast and fitting complete as per
design and drawing including cutting welding and fabrication with priming Kg 121.00
coat of red oxide and two coat of enamel paints.

8.4 Construction of Pump house of RCC framed structure as per approved


standard GA, structure, electrical drawing, scope of work and technical
specification complete work in all respect including electrical works for
indoor and outdoor lighting and fans, rain water drainage, sanitary,
plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to
or more than 7 T/sqm.
Note: Standard drawings can be viewed on website
https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx.

8.4.1 Type I ( 72.3 Sqm) Each 1956260.00


8.4.2 Type II ( 111.34 Sqm) Each 2765720.00
8.4.3 Type III ( 150.6 Sqm) Each 3361960.00
8.4.4 Type IV ( 212.9 Sqm) Each 5210970.00
8.4.5 Type V ( 381.5 Sqm) Each 8806160.00
8.4.6 Type VI ( 407.48 Sqm) Each 9863420.00
8.4.7 Type VII ( 692.72 Sqm) Each 13743840.00

PHED REVISED BSR 2023 PH Boundary wall 70


RajKaj Ref No. : 4242943
8.5 Construction of Pump house of RCC framed structure with pump pit in RCC
walls as per scope of work and technical specification complete work in all
respect including electrical works for indoor and outdoor lighting and fans,
rain water drainage, sanitary, plumbing, monorail/ EOT crane etc. complete
as per direction of Engineer-in-charge. The GA, structure, electrical,
sanitary, P&ID, SLD to be prepared by the contractor and submitted to
department for approval for earth quake zone II.

8.5.1 Pump House with Monorail arrangement sqm 22320.00


8.5.2 Pump House with suitable EOT arrangement with Girder sqm 24470.00
8.5.3 Add 4% for earth quake zone III on above item no. 8.5.1 & 8.5.2
8.5.4 Add 8% for earth quake zone IV on above item no. 8.5.1 & 8.5.2

PHED REVISED BSR 2023 PH Boundary wall 71


RajKaj Ref No. : 4242943
Chapter 9
Construction of Valve Chamber
S. No. Description Unit Rate (Rs.)
9.1 Construction of RCC Sluice valve chamber for different type of valves
including earthwork excavation, 100mm PCC M15 as levelling course,
RCC M25 grade for base slab, side wall & cover slab , including cost of
steel reinforcement , form work, Pre-cast slabs, plastic encapsulated
CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of
concrete work complete in all respect as per specifications and
standard drawings and as per direction of Engineer-in-Charge.
9.1.1. For Class-AA loading
9.1.1.1 Sluice valve chamber of size 1.13 m x0.85 m x1.325 m- Each 36700.00
for pipe size-up to 100 mm
9.1.1.2 Sluice valve chamber of size 1.17m x 0.95m x1.47m Each 40900.00
for pipe size-from 125-to-150mm
9.1.1.3 Sluice valve chamber of size 1.26m x1.185m x1.88m Each 52300.00
for pipe size-from 200-to-300mm
9.1.1.4 Sluice valve chamber of size 1.39m x1.43m x2.245m Each 65300.00
for pipe size-from 350-to-450mm
9.1.1.5 Sluice valve chamber of size 1.61m x1.75m x2.85m Each 89900.00
for pipe size-from 500-to-700mm
9.1.2 For Class-A loading
9.1.2.1 Sluice valve chamber of size1.13m x0.85m x1.27m Each 29800.00
for pipe size-upto100mm
9.1.2.2 Sluice valve chamber of size1.17m x0.95m x1.415m Each 33500.00
for pipe size-from 125-to-150mm
9.1.2.3 Sluice valve chamber of size1.26m x1.185m x1.82m Each 43500.00
for pipe size-from 200-to-300mm
9.1.2.4 Sluice valve chamber of size1.39m x1.43m x2.185m Each 55800.00
for pipe size-from 350-to-450mm
9.1.2.5 Sluice valve chamber of size1.61m x1.75m x2.795m Each 78900.00
for pipe size-from 500-to-700mm
9.1.3 For in-campus Valve Chambers
9.1.3.1 Sluice valve chamber of size1.13m x0.85m x1.225m Each 28800.00
for pipe size-upto100mm
9.1.3.2 Sluice valve chamber of size1.17m x0.95m x1.37m Each 32300.00
for pipe size-from 125-to-150mm
9.1.3.3 Sluice valve chamber of size1.26m x1.185m x1.76m Each 41700.00
for pipe size-from 200-to-300mm
9.1.3.4 Sluice valve chamber of size1.39m x1.43m x2.125m Each 52700.00
for pipe size-from 350-to-450mm
9.1.3.5 Sluice valve chamber of size1.61m x1.75m x2.72m Each 72600.00
for pipe size-from 500-to-700mm

PHED REVISED BSR 20223 Construction of Valve Chamber 72


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
9.2 Construction of RCC Air valve chamber for different type of valves
including earthwork excavation, 100mm PCC M15 as levelling course,
RCC M25 grade for base slab, side wall & cover slab , including cost of
steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated
CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of
concrete work complete in all respect as per specifications and
standard drawings and as per direction of Engineer-in-Charge.
9.2.1 For Class-AA loading
9.2.1.1 Air valve chamber of size0.9m x1m x1.695m Each 39600.00
for air valve size-from 50 mm-to-80mm
9.2.1.2 Air valve chamber of size1m x1.1m x1.945m Each 45800.00
for air valve size of 100mm
9.2.1.3 Air valve chamber of size1.05m x1.4m x2.42m Each 58900.00
for air valve size of 150mm
9.2.1.4 Air valve chamber of size1.325m x1.7m x2.875m Each 81100.00
for air valve size of 200mm
9.2.2 For Class-A loading
9.2.2.1 Air valve chamber of size0.9m x1m x1.71m Each 33500.00
for air valve size-from 50 mm-to-80mm
9.2.2.2 Air valve chamber of size1m x1.1m x1.96m Each 39500.00
for air valve size of 100mm
9.2.2.3 Air valve chamber of size1.05m x1.4m x2.42m Each 51100.00
for air valve size of 150mm
9.2.2.4 Air valve chamber of size1.325m x1.7m x2.9m Each 70800.00
for air valve size of 200mm
9.2.3 For in-campus Valve Chambers
9.2.3.1 Air valve chamber of size0.9m x1m x1.66m Each 32400.00
for air valve size-from 50 mm-to-80mm
9.2.3.2 Air valve chamber of size1m x1.1m x1.91m Each 38300.00
for air valve size of 100mm
9.2.3.3 Air valve chamber of size1.05m x1.4m x2.37m Each 49500.00
for air valve size of 150mm
9.2.3.4 Air valve chamber of size1.325m x1.7m x2.825m Each 66900.00
for air valve size of 200mm
9.3 Construction of RCC Scour valve chamber wet type for different type of
valves including earthwork excavation, 100mm PCC M15 as levelling
course, RCC M25 grade for base slab, side wall & cover slab , including
cost of steel reinforcement , form work, Pre-cast slabs, Plastic
encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast,
proper curing of concrete work complete in all respect as per
specifications and standard drawings and as per direction of Engineer-in-
Charge.
9.3.1 For Class-AA loading
9.3.1.1 Scour valve chamber of size1.13m x0.85m x1.985m Each 43800.00
for connecting pipe size-upto100mm
9.3.1.2 Scour valve chamber of size1.175m x0.95m x2.285m Each 47200.00
for connecting pipe size-more than 100 mm & up to 150mm

PHED REVISED BSR 20223 Construction of Valve Chamber 73


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)
9.3.1.3 Scour valve chamber of size1.2m x1.08m x2.485m Each 53200.00
for connecting pipe size- more than 150 mm & up to 200mm
9.3.2 For Class-A loading
9.3.2.1 Scour valve chamber of size1.13m x0.85m x1.95m Each 38106.00
for connecting pipe size-upto100mm
9.3.2.2 Scour valve chamber of size1.175m x0.95m x2.25m Each 41064.00
for connecting pipe size-more than 100 mm & upto150mm
9.3.2.3 Scour valve chamber of size1.2m x1.08m x2.45m Each 46284.00
for connecting pipe size-more than 150 mm & upto200mm
9.4 Construction of RCC Scour valve chamber dry type for different type of
valves including earthwork excavation, 100mm PCC M15 as levelling
course, RCC M25 grade for base slab, side wall & cover slab , including
cost of steel reinforcement , form work, Pre-cast slabs, Plastic
encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast,
proper curing of concrete work complete in all respect as per
specifications and standard drawings and as per direction of Engineer-in-
Charge.
9.4.1 For Class-AA loading
9.4.1.1 Scour valve chamber of size1.13m x0.85m x1.985m Each 38100.00
for connecting pipe size-upto100mm
9.4.1.2 Scour valve chamber of size1.175m x0.95m x2.285m Each 40400.00
for connecting pipe size- more than 100 mm & up to 150mm
9.4.1.3 Scour valve chamber of size1.2m x1.08m x2.485m Each 49200.00
for connecting pipe size- more than 150 mm & up to 200mm
9.4.2 For Class-A loading
9.4.2.1 Scour valve chamber of size1.13m x0.85m x1.95m Each 33147.00
for connecting pipe size-upto100mm
9.4.2.2 Scour valve chamber of size1.175m x0.95m x2.25m Each 35148.00
for connecting pipe size-more than 100 mm & upto150mm
9.4.2.3 Scour valve chamber of size1.2m x1.08m x2.45m Each 42804.00
for connecting pipe size-more than 150 mm & upto200mm
9.5 Construction of RCC pillar for following size of air valves including
earthwork excavation, RCC M25 grade for base slab, vertical pillar,
including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form
work, proper curing of concrete work complete in all respect as per
standard specifications and drawings and as per direction of Engineer-in-
Charge.
9.5.1 Air valve pillar for air valves size of 80mm dia Each 19800.00
9.5.2 Air valve pillar for air valves size of 100mm dia Each 21800.00
9.5.3 Air valve pillar for air valves size of 150mm dia Each 30400.00
9.5.4 Air valve pillar for air valves size of 200mm dia Each 36500.00

PHED REVISED BSR 20223 Construction of Valve Chamber 74


RajKaj Ref No. : 4242943
Chapter 10
Solar based water supply schemes
S. No. Description Unit Rate (Rs.)

10.1 Supply, installation, testing and commissioning of MNRE approved Grid tied
Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation
as well as Utility Scale Solar Power Projects with 25 years of Linear
Generation warranty. Work includes designing of solar panel area and MS
frame and foundation on ground/roof of Pump house or CWR, showing
arrangement of panel in available space, installation of PV module on MS
frame as per approved design and drawings. Mounting structure shall be
suitably designed to withstand wind velocity up to 150km/hr.
Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak
efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast
connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi /
internet based remote monitoring with 5 years warranty.
All cabling up to panel and metre, earthing etc. required accessories and
taxes are inclusive. The work shall be executed as per detailed technical
specifications, approved drawing and direction of Engineer in Charge.
Note: There shall be 5 year service warranty for panel, inverter, meter, cable
etc. and suitable provision shall be included in tender document.

10.1.1 Solar panels up to 10 KW at a single location. Watt 60.00


10.1.2 Solar panels more than 10 KW and up to 50 KW at a single location. Watt 57.00
10.2 Supply, installation, testing and commissioning of MNRE approved off Grid
Solar Panels for running of motor pumps with 25 years of Linear Generation
warranty, Work includes designing of solar panel area and MS frame and
foundation on ground/roof of Pump house or CWR, showing arrangement of
panel in available space, installation of PV module on MS frame as per
approved design and drawings. Mounting structure shall be suitably design Watt 43.00
to withstand wind velocity up to 150km/hr. The work shall be executed as
per detailed technical specifications, approved drawing and direction of
Engineer in Charge.
Note: There shall be 5 year service warranty for solar panel and mounting
structure and suitable provision shall be included in tender document.

PHED REVISED BSR 2023 Solar based water supply schemes 75


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

10.3 Supply, installation, testing and commissioning of MNRE approved off Grid
Solar Panels for running of motor pumps with 25 years of Linear Generation
warranty, Work includes designing of solar panel area and MS fabricated
structure 120 micron hot dip galvanized iron , showing arrangement of panel
in available space and installation of PV module on frame structure such
that minimum height of lower edge of panel shall be 4.0 mtr from ground
level to safeguard against damage and theft as per indicative drawing
enclosed with the bid document. The foundation of structure shall be in RCC. Watt 60.00
Mounting structure shall be suitably designed to withstand wind velocity up
to 150km/hr. The work shall be executed as per detailed technical
specifications, approved drawing and direction of Engineer in Charge.
Note: There shall be 5 year service warranty for solar panel and mounting
structure and suitable provision shall be included in tender document.

10.4 Supply, installation, testing and commissioning of MNRE approved off Grid
Solar Panels for running of motor pumps with 25 years of Linear Generation
warranty, Work includes designing of solar panel area and structure,
showing arrangement of panel on rectangular OHSR with flat roof/ MS
fabricated structure with polyethylene tank and installation of PV module
on above structure as per approved design and drawings. Mounting
structure shall be suitably design to withstand wind velocity up to 150km/hr.
The work shall be as per detailed technical specifications, approved drawing Watt 51.00
and direction of Engineer in Charge.
This item does not include cost of OHSR/ MS fabricated structure with tank
but includes cost of items required for installation of solar panels on top of
the tank.
Note: There shall be 5 year service warranty for solar panel and mounting
structure and suitable provision shall be included in tender document.

10.5 Providing, installation, testing and commissioning of AC submersible pump


sets with inbuilt or individual solar pump controller with Maximum power
point tracking (MPPT) for optimally use the solar panel and maximize water
discharge to deliver maximum water during the day including PVC flat
submersible cable from controller to motor pumps..
Solar pump shall be of Stainless steel construction and performance shall be
as per scope of work and minimum lift of water shall be as per defined in
scope .
Pump controller shall have Adequate protection against dry operation of
motor pump set, and against hails and storms. Full protection against open
circuit, accidental short circuit and reverse polarity should be provided. A
good reliable on/off switch be provided. The cable shall be ISI marked three
core PVC flat submersible cable as per IS 694:1990 or amended up to date (
standard insulation) and conductor as per class 5 of IS 8130:1980 or
amended up to date.
The duty condition of pump set shall be as per scope of work and entire
work shall be executed as per technical specification and direction of
Engineer in charge.

10.5.1 0.75 KW (1.0 HP) Each 74206.00


10.5.2 1.5 KW (2.0 HP) Each 79201.00
10.5.3 2.2 KW (3.0 HP) Each 114790.00

PHED REVISED BSR 2023 Solar based water supply schemes 76


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

10.5.4 3.7 KW (5.0 HP) Each 147415.00


10.5.5 5.5 KW (7.5 HP) Each 181598.00
10.5.6 7.5 KW (10.0 HP) Each 197932.00
10.5.7 9.3 KW (12.5 HP) Each 222830.00
10.5.8 11 KW (15.0 HP) Each 244433.00
10.6 Supply, installation, testing and commissioning of DC submersible pump sets
with inbuilt or individual solar pump controller with Maximum power point
tracking (MPPT) for optimally use the solar panel and maximize water
discharge to deliver maximum water during the day including PVC flat
submersible cable from controller to motor pumps.
Solar pump shall be of Stainless steel construction and performance shall be
as per scope of work and minimum lift of water shall be as per defined in
scope .
Pump controller shall have Adequate protection against dry operation of
motor pump set, and against hails and storms. Full protection against open
circuit, accidental short circuit and reverse polarity should be provided. A
good reliable on/off switch suitable for DC use is to be provided. The cable
shall be ISI marked three core PVC flat submersible cable as per IS 694:1990
or amended up to date ( standard insulation) and conductor as per class 5 of
IS 8130:1980 or amended up to date.
The duty condition of pump set shall be as per scope of work and entire
work shall be as per technical specification and direction of Engineer in
charge.

10.6.1 0.75 KW (1.0 HP) Each 112033.00


10.6.2 1.5 KW (2.0 HP) Each 131843.00
10.6.3 2.2 KW (3.0 HP) Each 164690.00
10.7 Supply, installation, testing and commissioning of Remote monitoring unit on
off grid solar controller for remote ON/OFF, parameter setting, monitoring
and troubleshooting through mobile etc. complete. Web charges and data
Each 45830.00
charges for 5 year during service warranty etc. complete in all respect as per
technical specification and as per direction of Engineer.

10.8 Providing, installation, testing and commissioning structural steel work


riveted or bolted in built up sections, trusses and framed work, including
cutting, hoisting for following staging and capacity of Rotational Moulded
Polyethylene water storage tank on it as per indicative drawing given in the
bid document. On the Polyethylene tanks, there shall be provision of
suitable space for installation of solar panels up to 5.0 KW and further
additional 2.5 KW on the side of Steel structure if required as per indicative
drawing. Cost of solar panels is not included in this item .
The structural steel shall be 120 micron hot dip galvanized iron and
foundation of structure shall be in RCC with minimum depth as 2.0 mtr

PHED REVISED BSR 2023 Solar based water supply schemes 77


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

(other than rocky strata). The work includes P&F of Polyethylene Water
Storage Tank(IS: 12701, ISI marked, indicating the BIS license No.) of
approved make with cover. Providing & fixing 50 mm dia ISI marked G.I. class
B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash
out with GM gate valves at inlet and outlet pipe Including making connection
etc. complete as per drawing, technical specification and direction of
Engineer in In charge. The scope includes inlet GI pipe from ground level to
water tank and outlet pipe from water tank to ground and up to 2.0 mtr
away from foundation and overflow pipe is to be interconnected in
distribution pipe line. Wash out pipe shall be taken up to a suitable point
minimum 5.0 mtr away from tank. Water level controller shall installed to
monitor level in tank and shall automatically shut off motor when tank is
filled .

Note: There shall be 5 year service warranty for structure, tank, fittings etc.
and suitable provision shall be included in tender document.

10.8.1 5000 Litre X 2 Nos. PE water tank, staging 10 meter. Each 665565.00
10.8.2 7500 Litre X 2 Nos. PE water tank, staging 10 meter. Each 731261.00
10.8.3 5000 Litre X 2 Nos. PE water tank , staging 12 meter. Each 754589.00
10.8.4 7500 Litre X 2 Nos. PE water tank, staging 12 meter. Each 816729.00

PHED REVISED BSR 2023 Solar based water supply schemes 78


RajKaj Ref No. : 4242943
Chapter 11

Instrumentation
S. No. Description Unit Rate (Rs.)

Electromagnetic Flow meter


SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of
following dia and specifications complete: Media : Water (Raw/
Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C,
Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/
Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) ,
Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI
304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide
completely sealed (leak proof) construction as per requirement of IEC
60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal
convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC -
11.1 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/
Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of
RAM/PROM to store calibration and configuration parameters and totalizer
value during power failure, Protection category- IP 68 for sensor (flow tube)
and IP 67 for transmitter/ convertor, including Surge Arrester, if required,
and all materials required for making connection etc. complete in all respect
as per technical specification and direction of Engineer In-Charge.
Note: Rates are exclusive of tail piece / dismantling joints and earth work.

11.1.1 EFM 50 mm Each 92924.00


11.1.2 EFM 80 mm Each 103636.00
11.1.3 EFM100 mm Each 113454.00
11.1.4 EFM 125 mm Each 126481.00
11.1.5 EFM 150 mm Each 139687.00
11.1.6 EFM 200 mm Each 141972.00
11.1.7 EFM 250 mm Each 177439.00
11.1.8 EFM 300 mm Each 219283.00
11.1.9 EFM 400 mm Each 275303.00
11.1.10 EFM 450 mm Each 387167.00
11.1.11 EFM 500 mm Each 424286.00
11.1.12 EFM 600 mm Each 520970.00

PHED REVISED BSR 20223 Instrumentation 79


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

ULTRASONIC FLOW METER


SITC of Ultrasonic Flow Meter of approved make of following dia sized
pipelines and specifications complete: Media : Water (Raw/Clear ) ,
Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow velocity range: -
10 m/s to +10m/s (bidirectional), Power supply- 80 to 240 v/ AC, 50
Hz.,Output 1 : 4-20 mA, Communication Output : RS 485, Display Type : LCD/
LED Display, Cable Entry : M20 X 1.5, Acoustic path: single/ dual, Accuracy :
11.2 ± 1% of M.V (max.) for size 50-300mm and ± 2% of M.V (max.) for size 350-
2000mm (single path) , Transmitter Enclosure: Cast Aluminium, Sensor
cable: encapsulated, Sensor mounting method: V / Z type, Protection type:
IP 67, including all materials required for Ultrasonic Flow Meter complete
in all respect as per technical specification and as per direction of Engineer
In-Charge.
11.2.1 UFM 200mm -600 mm (CLAMP ON TYPE) Each 338520.00
11.2.2 UFM 200mm -600 mm (INSERTION TYPE) Each 393889.00
BULK FLOW METER (MECHANICAL TURBINE TYPE)
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to
ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines
and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr.
rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200,
Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry
Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection
11.3
including all materials and making connection with existing pipeline required
for Bulk Flow Meter including cutting the existing pipeline etc. complete in
all respect as per technical specification and as per direction of Engineer In-
Charge.
Note: Rates are exclusive of tail piece / dismantling joints and earth work.

11.3.1 BFM 80 mm Each 12688.00


11.3.2 BFM100 mm Each 15496.00
11.3.3 BFM 125 mm Each 21528.00
11.3.4 BFM 150 mm Each 24022.00
11.3.5 BFM 200 mm Each 30414.00
11.3.6 BFM 250 mm Each 64440.00
11.3.7 BFM 300 mm Each 86665.00
11.3.8 BFM 400 mm Each 145399.00
11.3.9 BFM 450 mm Each 166531.00
11.3.10 BFM 500 mm Each 247467.00
11.3.11 BFM 600 mm Each 265434.00

PHED REVISED BSR 20223 Instrumentation 80


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

ULTRASONIC LEVEL SENSOR


SITC of Ultrasonic Level Transmitter suitable for measuring water level in
reservoir, Normal Powered 24VDC, Type of Transmitter: Two Wire ( 4-20
mA), Cable Entry:1/2" NPT (F), Sensor Material: PP, slip-on Flange: 2 ½”
11.4 Flange, Material of Construction for Slip-on flange: PP, output 4~20mA,
HART compatible, accuracy +/_ 0.2 % as per detailed Technical specification,
scope of work and direction of Engineer in charge.
11.4.1 Measuring range 0.0 to 6.0 mtr Each 65789.00
SITC of Ultrasonic Level Transmitter suitable for measuring water level in
reservoir, powered by solar panel with minimum 48 power back up or
internal installed battery ( 5 years battery life with replacement warranty),
11.5
with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_
0.2 %, as per detailed Technical specification, scope of work and direction of
Engineer in charge.
11.5.1 Measuring range 0.0 to 6.0 mtr Each 119106.00

PHED REVISED BSR 20223 Instrumentation 81


RajKaj Ref No. : 4242943
Chapter 12
Earth Work & Civil Works related to Storage Tank, Filter media work

S. No. Description Unit Rate (Rs.)

STORAGE TANKS
12.1 Earth work in excavation over area ( for Sedimentation cum storage tank) Cum 93.00
Exceeding 30 cm in depth 1.5 Mtrs in width as well as 10 Sqm on plan)
including disposal of excavated earth lead up to 50 M and all lift.
Disposed earth to be levelled and neatly dressed including stacking of
useful material if any available during excavation for all kind of soil. Earth
work to be carried out by means of mechanical system i.e. Tractor craw or
any other mechanical system. No extra payment shall be done for lift of
any limit. This work also involves dressing of sides & bottom for lining
purpose which is to be done manually, slope of sides to be maintained as
per specification. Work is to be done as per direction of Engineer In
Charge and technical specifications.

12.2 Silt clearance from Sedimentation cum storage tank with all lift and lead Cum 117.00
up to 50 Mtr. Silt to be disposed outside the Headworks boundaries.
Disposed silt to be levelled and neatly dressed including stacking of useful
material if any available during excavation for all kind of soil. Silt
clearance is to be carried out by means of mechanical system i.e. Tractor
craw/Trolley or any other mechanical system. No extra payment shall be
done for lift . This work also involves dressing of bottom which is to be
done manually and there shall be no damage to lining and LDPE film of
tank. Work is to be done as per direction of Engineer In Charge and
technical specifications.

NOTE :- For additional lead, beyond 50M, every additional lead will be
paid as per PWD BSR. But for lead of 500M, 1 km. and onward; initial rate
of 50M will be deducted from concern rates of above said leads

12.3 SINGLE FLAT BRICK LINING WITH 250 MICRON LDPE FILM:- Preparing Sqm 589.00
surface levelled & dressed to proper slope & laying over it on sand
properly rammed and watered in 2 Layers of 5 cm each. Providing and
laying 250 micron LDPE film as per ISS:2506-1984 including overlapping
on the finished surface of compacted sand. Over LDPE film 15 mm thick
cement sand mortar 1:3 shall be provided and laid which shall be cured
properly. Over the base mortar single layer Ist class brick lining in cement
sand mortar 1:3 shall be provided with joints not more than 8 mm wide
and curing shall be done for 14 days. This also includes providing
weedicides & anti-termite treatment, complete work as per technical
specifications.

12.4 Providing and fixing PVC float in Raw Water Storage tank with CI tail piece Job 15804.00
150mm dia-2 Nos, CI puddle collar-150mm dia- 1.20 M- 1 No. and PVC
hose pipe- 150mm dia -6 M & all accessories complete in all respect as
per Instructions of Engineer In Charge. Complete Job

82
PHED REVISED BSR 2023 EW Storage tank, Filter media
RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

FILTER MEDIA
12.5 Providing and placing of new graded gravel as (i) Size of Gravel vary from Cum 3926.00
50 mm at the bottom to 2. to 5 mm at the top as detailed: (a) Passing 80
mm screen but held on 10 mm- 150 mm layer (b) Passing 25 mm screen
but held on 10 mm- 50 mm layer (c) Passing 10 mm screen but held on 5
mm- 50 mm layer Passing (d) 5 mm screen but held on 2 mm- 50 mm
layer (ii) The filter gravel shall be as spherical as possible, hard, clean and
uniform in quality and also shall not contain such impurities as dirt and
clay as per IS: 8419 (Part-I) for filter gravel specifications. The work also
includes washing the gravel with required concentration of HCL acid and
finally with water and placing the same in filter beds as per direction of
Engineer- In- Charge and technical specification complete in all respect.
The gravel shall not contain more than 5% acid soluble matter as
determined by solubility test in Appendix B of IS: 8419 (Part-I) amended
up to date. (For RGF)

12.6 Supply and charging of filter media (Gravel) as per department Cum 2086.00
specification including screaming, washing with 5% HCL solution to make
Gravel (Size 4 to 6mm, 8 to 12mm, 10 to 20mm - Hard Coarse grit from
approved quarry) free from silt, clay and other all impurities work to be
executed as per scope of work fixed by the department at the time of
tendering (for SSF)
12.7 Providing and Placing of new filter media as (i) Sand shall be hard and Cum 4190.00
resistant quartz or quartzite and free of clay, fine particles, soft grains and
dirt of any description. (ii) Effective size shall be 0.45 to 0.70 mm. (iii)
Uniformity Coefficient not be more than 1.70 nor less than 1.30. (iv)
Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in
HCL acid shall not exceed 5.0% by weight, (vi) Silica content should not be
less than 95% (vii) Specific Gravity shall be in the range between 2.55 to
2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications
given in IS: 8419 (Part-I). Filter media (fine sand and coarse sand) should
be processed through disintegrator and dust separator in automatic plant
including screening of sand to desired specification and washing and
cleaning of sand with water by aqua wash technology at quarry site. (For
RGF)

12.8 Providing and Placing of new filter media as (i) Sand shall be hard and Cum 4190.00
resistant quartz or quartzite and free of clay, fine particles, soft grains and
dirt of any description. (ii) Effective size shall be 0.20 to 0.30 mm. (iii)
Uniformity Coefficient not be more than 5.0 nor less than 3.0. (iv) Ignition
loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid
shall not exceed 7.0% by weight, (vi) Silica content should not be less than
95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii)
Wearing loss shall not exceed 3.0%. and as per specifications given in IS:
8419 (Part-I). (ix) The sand should not contain more than 2% of calcium
and manganese calculated as carbonate. Filter media (fine sand and
coarse sand) should be processed through. Disintegrator and dust
separator in automatic plant including screening of sand to desired.
Specification and washing and cleaning of sand with water by aqua wash
technology at quarry site. The sand shall not contain more than 5% acid
soluble matter as determined by solubility test in Appendix B of IS: 8419
(Part-I) (Fine sand 0.2 to 0.3mm and coarse sand 1.0 to 1.7mm) (For SSF)

83
PHED REVISED BSR 2023 EW Storage tank, Filter media
RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs.)

12.9 Fixing of pipes for under drainage system including plugging pipes with RM 32.00
CM 1:4 on one end and fixing other end in collecting channel with CM 1:4
with all Material etc.(Excl.cost of pipes) This job, also, includes Making
4mm dia holes in pipes @15 cm c/c in zig-zag pattern and testing of
under drainage system as per instruction of Engineer-in-charge.

12.10 Removing & Re-fixing of pipes for under drainage system including RM 26.00
cleaning of one end plugged pipes and fixing /embedded in CM 1:4 on
one end and fixing other end in collecting channel with CM 1:4 with all
Material etc.(Excl.cost of pipes) This job, also, includes Making 4mm dia
holes if required in pipes @15 cm c/c in zig-zag pattern.

12.11 Making 4mm dia hole in pipes of under drainage system of filters duly Each 2.00
drilled. Carriage of pipe from stacks to filter site, making two per rows on
pipe and points of making holes in Zig-Zag pattern in two hold raw.
Making 4mm dia holes with drill machine @ 15cm c/c in zig-zag pattern.

12.12 Labour charges for screening of old sand (received from filter beds) Cum 915.00
through the standard sieves, washing the sand with HCL acid of required
concentration as directed by the Engineer- In- Charge, so as to remove all
the mud and other deposits from sand grains and then clean with water
till the sand is as neat and clean that it impart no colour to clean while
washing. It also includes placing this washed filter media (sand) in filter
beds in layer as instructed by the Engineer- In- Charge. (RGF, SSF)

12.13 Labour charges for screening of old gravel (received from filter beds) Cum 685.00
through the standard different sizes sieves for required sizes of gravel,
washing the gravel with HCL acid of required concentration as directed by
the Engineer- In- Charge, so as to remove all the mud and other deposits
from gravel grains and then clean with water till the gravel is as neat and
clean that it impart no colour to clean while washing. It also includes
placing this washed gravel in filter beds in layer as instructed by the
Engineer- In- Charge. (RGF, SSF)

84
PHED REVISED BSR 2023 EW Storage tank, Filter media
RajKaj Ref No. : 4242943
Chapter 13

Construction and Commissioning of Water treatment Plant (WTP)

S. No. Description Unit Rate (Rs.)


13.1 Design, construction, commissioning & testing of Non Mechanical Rapid
Gravity Filter Plant of capacity as under. This work includes construction
of RCC receiving chamber, baffle channel, flocculate, clarifier, collecting
channel, filter beds , operation gallery, clear water chamber, channel,
chlorination chamber, Back wash tank, pipe system for carrying raw
water from Pump House to inlet of RGF, clear water from Plant to CWR,
De-sludging system including providing pipe system from clarifier ,
flocculate & back wash water chamber to existing storage tank, over
head back wash tank, back wash pumps (1W+1S) set with piping system,
air blowers (1W+1S) as per design, interconnection of raw water, clear
water, sludge pipes etc. including allied works such for construction
,commissioning of system as defined in scope of work, technical
specifications and provisions of CPHEEO manual at various water supply
schemes
13.1.1 Up to 40 KLH capacity KLH 95,000.00
13.1.2 Above 45 KLH and up to 60 KLH KLH 90,000.00
13.1.3 Above 65 KLH and up to 90 KLH KLH 78,000.00
13.1.4 Above 100 KLH and up to 125 KLH KLH 71,000.00
13.1.5 Above 130 KLH and up to 160 KLH KLH 66,000.00
13.1.6 Above 170 KLH and up to 200 KLH KLH 62,000.00
13.1.7 Above 205 KLH and up to 300 KLH (Deduct 1% per 5 KLH in rate of item KLH
13.1.6
13.2 Design, construction, testing and commissioning of Rapid Gravity Filter
Treatment Plant including all relevant civil, electrical , mechanical
,instrumentation, automization and SCADA works, chemical building and
stores along with ancillary civil works as defined in scope of work,
technical specification and provisions of CPHEEO manuals for the
following capacity .
13.2.1 Cost of 200 KLH Each 2,66,00,000.00
13.2.2 Add per KLH above 200 KLH and up to 500 KLH KLH 1,12,200.00
13.2.3 Cost of 500 KLH Each 6,02,60,000.00
13.2.4 Add per KLH above 500 KLH and up to 2000 KLH KLH 1,01,800.00
13.2.5 Cost of 2000 KLH Each 21,29,60,000.00
13.2.6 Add per KLH above 2000 KLH and up to 5000 KLH KLH 90,600.00
13.2.7 Cost of 5000 KLH Each 48,47,60,000.00
13.2.8 Add per KLH above 5000 KLH and up to 75000 KLH KLH 79,100.00

PHED REVISED BSR 2023 WTP 85


RajKaj Ref No. : 4242943
Chapter 14
Miscellaneous
S. No. Description Unit Rate (Rs)
14.1 Survey by Electronic Total station/DGPS of villages with a view of preparing
"village index plan "indicating roads/ streets, surface and width of road/
streets along with places of importance such as Panchayat Bhawan,
Hospital, School, Post office, Temple Water Supply structures (GLRs, PSPs,
pumping station physical boundary of village north etc. including levels at
some important points as per instruction of engineer in charge. Hydraulic
Design of Distribution network in Loop/Water Gem/EPANET or any other
compatible software. Preparation of Auto CAD Drawing (A-3/A-2) with
complete hydraulic design out put details, such as pipe no, node no, pipe
length, pressure at node etc. Submission of three sets of colour print
prepared in Auto CAD.

14.1.1 Rate for length up to 2.5 km No. 8000.00


14.1.2 Add extra for length more than 2.5 km Km 2000.00
14.2 Survey of all properties, preparation of GIS based consumer mapping of
consumer water connection database, plotting assets on GIS map etc. FHTC 42.50
(Satellite image will be provided by the Department)

14.3 Data entry of existing FHTCs in rural area under JJM on website
ejalshakti.gov.in; work includes visiting the village for collecting basic data
consumers like i.e. Aadhar no./ration card/voter ID/BPL card/ PAN
FHTC 30.00
card/driving license/passport/Antyodaya card/mobile no. etc. and entering
the details on the above website. The cost also includes computer and
operator.
14.4 Preparation of DPRs for single and small multi village rural water supply
schemes under JJM for Administrative & Financial Sanction and Technical
sanction, the work includes:
Survey by Electronic Total station/DGPS of villages with a view of preparing
village index plan, existing HW plan and survey for route of rising/ trunk
mains, indicating roads/ streets, surface and width of road/ streets along
with places of importance such as Panchayat Bhawan, Hospital, School, Post
office, Temple Water Supply structures (GLRs, PSPs, pumping station
physical boundary of village north etc. including levels and TBM at
important places as per instruction of engineer in charge.
Preparation of technical report, forecasting of population and design
demand, source design, techno-economic design of rising mains, selection
and design of pumps sets, capacities of CWR, OHSR etc. complete work as
per departmental prevailing guidelines and practice.
Hydraulic Design of Distribution network in Loop/Water Gem/EPANET or
any other compatible software. Preparation of Auto CAD Drawing (A-3/A-2)
with complete hydraulic design output details, such as pipe no, node no,
pipe length, pressure at node etc.

PHED REVISED BSR 2023 Miscellaneous 86


RajKaj Ref No. : 4242943
S. No. Description Unit Rate (Rs)
Preparation of estimate of various components based on prevailing BSRs in
PHED and non BSR if any with detailed analysis. Preparation of conceptual
drawings, L-sections for rising mains, HW plan, GA drawings of P.S., ESR,
CWR, GLSR, valve chambers etc.
Printing of DPR in 6 copies, including drawings in appropriate size of paper
for A&F and technical sanctions separately as per direction of EIC. Reply of
observation raised by department for A&F and TS shall be submitted within
timeframe as per scope of work.
Work excludes preparation of Bid document and rates are including GST and
all other taxes applicable.
The DPR shall include all other habitation and main village in a unit.
14.4.1 For present population 100-500 souls Per village 28000.00
14.4.2 For present population 501-1500 souls Per village 32398.00
14.4.3 For present population 1501-4000 souls Per village 43661.00
14.4.4 For present population above 4001 souls Per village 44943.00

PHED REVISED BSR 2023 Miscellaneous 87