SR VW MQB-FL-Touch ICEV M0055 014966-19-BQ 20191226 en
SR VW MQB-FL-Touch ICEV M0055 014966-19-BQ 20191226 en
***** 1 : start
device**************************************************************
Identification Min Actual Max
State
-----------------------------------------------------------------------------------
---------
SET: Switch 012, Wert=1 'MAX_HW100'
housing without without any damages
passed
all 4 mounting clips installed?
passed
HMF 'c:\VW_MQB_FL_Touch\projects\HMF\014966-19-BQ.hmf' successfully loaded.
Added Value '5ZB' for Index '9', Byte(s) '3 1' to Structure.
Added Value '001' for Index '9', Byte(s) '6 4' to Structure.
Features: 2 Zones, Base, w/o SYNC, VW, PCB: -10 2C_BASE, ICEV, no MAX
Customer Sparepart Number: '3CC907044AJ', Customer SW Number: '3VD907044' 0:
Combustion, w/o ParkHeater
***** 3 : Read
EEPROM***************************************************************
Bandendetest (EOL) startet !
Header Data from HMF
Comment 2C Base
(New Bora)
Author Kartheek P
MKSRevision $Revision$
PartNumber 014966
Abart 19
Revision BQ
HW Variante H01
SW-Version 0109
Checksum 0x77FE0F43
Sw Version-File-ICT 3VD907044 _0109
Generationsstand 01S
PCB-Feature 10
PortPinConfiguration (PPC) 0
2-1_Test-Feature Analog-Inputs 14
2-2_Test-Feature Analog-Inputs 24
2-3_Test-Feature Analog-Inputs 3
2-4_Test-Feature Analog-Inputs 0
2-5_Test-Feature Analog-Inputs 15
2-6_Test-Feature Analog-Inputs 0
3_Test-Feature Digital-Inputs 1
PIC-SW Version-1 48
PIC-SW Version-2 48
***** 4 :
Softwareversion***********************************************************
Softwareversion: '0109' read
passed
Checksum '0x77fe0f43'
passed
SW-Version CapSense-Controller: '0x30 0x30' read
passed
***** 5 :
Label*********************************************************************
Label Data:
***** 6 :
Identification************************************************************
SET: Switch 101, Wert=1 'Kl30_Top'
SET: CAN Node: Gateway_73 Sig: MO_Drehzahl_01 Val: 0 Unit_Min''
SET: CAN Node: Dimmung_01 Sig: DI_KL_58xd Val: 10 ''
SET: CAN Node: Dimmung_01 Sig: DI_KL_58xs Val: 10 Unit_Pe''
SET: Diag Modus 0x03 'Extended $03'
passed
Active Diagnostic Session: '03: Extended Diagnostic Session'
VW FAZIT Identification String: '5ZB-00126.12.1900300055'
ECU Programming Information: '64'
Programming Date: '0x31 PARAMETER AU�ERHALB DES
WERTEBEREICHS'
VW Repair Shop Code Or Serial Number: '0x31 PARAMETER AU�ERHALB DES
WERTEBEREICHS'
NumberOfLogins: '0x31 PARAMETER AU�ERHALB DES
WERTEBEREICHS'
VW Calibration Repair Shop Code Or Serial '00 00 00 00 00 00'
VW Calibration Date: '00.00.00'
Vehicle Equipment Code PR No Combination: '00 00 00 00 00 00 00 00 00 00 00 00'
VW Dataset Or ECU Data Container Number: '-----------'
ASAM ODX File Identifier: 'EV_AirCondiBHTCMQB3rTranc'
ASAM ODX File Version: '001035'
VW System Name or Engine Type: 'Climatronic '
VW Workshop System Name: 'J255 '
VW Spare Part Number: '3CC907044AJ'
passed
VW ECU Hardware Number: '3CC907044AJ'
passed
VW Software Version Number: '0109'
passed
VW ECU Hardware Version Number: 'H01'
passed
VW SW-Version: '0109'
BHTC SW-Version: '----'
SW Variant: 'Not support by ECU.'
Coding: 0x10 0x02 0x02 0x04 0x20 0x00 0x10 0x01 0x00 0x04 0x00 0x00 0x00 0x10 0x10
0x06
Fault Memory read 1 Error(s)
***** 7 :
UIF***********************************************************************
XCP_ITOS Sun [] 0 0 0
passed
calc UIF_SUN [cnts] 887 887 887
passed
SET: Switch 207, Wert=0 'Lamp'
remove lamp from UIF!
passed
SET: CAN Node: Dimmung_01 Sig: DI_KL_58xd Val: 250 ''
SET: CAN Node: Dimmung_01 Sig: DI_KL_58xs Val: 100 Unit_P''
Diag_Variantcoding write
passed
New Coding: 0x10 0x02 0x02 0x04 0x20 0x00 0x10 0x01 0x00 0x04 0x00 0x00 0x00 0x10
0x10 0x06
Diag PowerOnReset
passed
***** 10 : Test :
illumination*******************************************************
Background Dimming 100 Perc ON ON ON
passed
Backlight Led's dimmed YES YES YES
passed
Function Leds 100 Perc ON ON ON
passed
Function Led's dimmed YES YES YES
passed
LED Defrost OFF OFF OFF
passed
LED Rear Window Heater OFF OFF OFF
passed
LED Air Distrbution Head OFF OFF OFF
passed
LED Air Distrbution Man OFF OFF OFF
passed
LED Air Distrbution Feet OFF OFF OFF
passed
LED Clean Air OFF OFF OFF
passed
LED Recirculation OFF OFF OFF
passed
LED Auto OFF OFF OFF
passed
LED AC OFF OFF OFF
passed
LED OFF OFF OFF OFF
passed
LED Blower Level 6 YES YES YES
passed
LED Blower Level 5 YES YES YES
passed
LED Blower Level 4 YES YES YES
passed
LED Blower Level 3 YES YES YES
passed
LED Blower Level 2 YES YES YES
passed
LED Blower Level 1 YES YES YES
passed
LED Blower Level 0 YES YES YES
passed
***** 11 :
Display*******************************************************************
Display Left and Right: all Segments ON YES YES YES
passed
Display Left Temp Display 'LO', '00.0' - '99.9', 'HI'
passed
Display Right Temp Display 'LO', '00.0' - '99.9', 'HI'
passed
***** 13 :
Inputs********************************************************************
SET: Sensor 001, Wert=1.00 'GRUNDSTELLUNG'
0 Error(s)
***** 16 : Checking
outputs**********************************************************
***** 17 : Quiecent
current**********************************************************
Fault Memory read 1 Error(s)