Course description

M111
Harmony Control Unit – Rack I/O with Composer

Learn the INFI 90 Open/Symphony


system architecture and Harmony Control
Unit hardware. Create and monitor
a process control strategy utilizing
Composer software.

Course type and methods − − Configure and implement Multi-Function Processor (MFP),
This is an instructor led workshop with short presentations and Bridge Controller (BRC) and various I/O modules along with
demonstrations, extended exercises, and hands-on sessions their support equipment
and discussion. − − Establish MFP/BRC redundancy
− − Perform on-line configuration
Student profile − − Read the field input/output external connection drawings
This training is targeted to students responsible for DCS
component selection, installation, maintenance and process Main topics
control implementation and documentation. It is also a − − Symphony/INFI 90 Open control system architecture
prerequisite for anyone planning to attend course M202, − − Symphony/INFI 90 Open control system data communication
Composer Automation Architect. − − Harmony Function Code programming basics
− − Symphony/INFI 90 Open control system diagnostics
Prerequisites
Students should have a basic knowledge of process control Duration
and operations concepts. Basic knowledge and usage of The duration is 5 days.
applications running on the Windows® operating system is also
recommended.

Course objectives
Students will learn about the features of the Symphony/INFI 90
Open control system and the Harmony Control Unit hardware
components. Using a simple process control loop model as a
base project, students will utilize Composer software to create a
process control strategy for monitoring, tuning, and diagnostics.

Upon completion of this course the participants will be able to:

−− Incorporate Symphony/INFI 90 Open hardware into the


process strategy
−− Interpret conventional ABB cabinet arrangement drawings
−− Recognize basic function codes
−− Establish data highway communication
Course outline

Day 1 Day 2 Day 3 Day 4


−− Course overview −− Review: questions and −− Review: questions and −− Review: questions and
−− Introductions answers answers answers
−− Symphony/ INFI 90 Open −− Harmony process controllers −− Composer project definition −− Harmony Rack I/O module
overview −− Cabinet arrangement −− Closed loop configuration hardware
−− Symphony/ INFI 90 Open drawings −− On-line configuration −− Harmony Rack I/O module
loop communications −− Introduction to Harmony configuration
−− Symphony/ INFI 90 Open Function Codes

3BUS095106 SM2010-029
node communications

Day 5
−− Review: questions and
answers
−− Harmony Rack I/O module
configuration
−− Open lab

To register contact the North America Customer Service Center


or visit our website.

North America Customer Service Center


29801 Euclid Avenue
Wickliffe OH 44092 1832, USA
Tel: 1 800 HELP 365 (1 800 435 7365)
Outside USA/Canada: +1 440 585 7804
Option 2, then 4 for training
Fax: +1 860 298 3656
E-mail: [email protected]
Web: www.abb.us/abbuniversity

© 2011 ABB Inc.


ABB reserves the right to change specifications without notice.

You might also like