0% found this document useful (0 votes)
142 views

Concrete Test Report

This document is a concrete cube test report from the Central Regional Laboratory in Sibu, Sarawak for a bridge project in Julau. It provides the results of compression testing on 6 concrete cubes with dimensions of 150x150x150 mm. The cubes were cast on August 11th and tested on August 18th and September 8th at 7 and 28 days. All cubes met or exceeded the target compressive strength of 40 N/mm2. The highest strength was 48.0 N/mm2. The report concludes with notes that the test results only apply to the samples received and that cube information was provided by the customer.

Uploaded by

Frasser George
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views

Concrete Test Report

This document is a concrete cube test report from the Central Regional Laboratory in Sibu, Sarawak for a bridge project in Julau. It provides the results of compression testing on 6 concrete cubes with dimensions of 150x150x150 mm. The cubes were cast on August 11th and tested on August 18th and September 8th at 7 and 28 days. All cubes met or exceeded the target compressive strength of 40 N/mm2. The highest strength was 48.0 N/mm2. The report concludes with notes that the test results only apply to the samples received and that cube information was provided by the customer.

Uploaded by

Frasser George
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CMLMS/CRL/SOPT/1/R

PUSAT MAKMAL BAHAN-BAHAN,


JABATAN KERJA RAYA SARAWAK.
(CENTRAL REGIONAL LABORATORY)
CENTRAL REGIONAL LABORATORY,
JKR SARAWAK,
Ground and 1st Floor, Bangunan Kerajaan Negeri, Jalan Awang Ramli Amit,
96000 Sibu, Sarawak.
Tel: 084-210929 Fax: 084-210143

CONCRETE CUBE TEST REPORT


Test Standard MS 26 Part 2 :1991 (Cube Compression)

*Project DESIGN AND BUILD AND NEGOTIATED - MEMBINA JAMBATAN NG. LASI, JULAU
Date Issued 08/09/2023
Date Tested 08/09/2023
Request Form No. 2023/CRL/CC/01251
Name of person making cubes Romeano
11/08/2023 21:00 Condition of
#Date, time and place of
Test Report Ref. 2023/CRL/CC/01251/CT/01-2 PM, Sarikei, specimen when Satisfactory
sampling
Julau received
*Number and norminal size of 6 units, Date of receipt of
*Client Frasser Anak George Michael 14/08/2023
specimens (mm) 150x150x150 specimen
*Method of compaction (hand or
Avg. lab
vibration) including type of Hand 27
*Sample Covering temperature, °C
PWD/CRL/LAB/04/2023/PT.03/56 equipment used
Ref.
Avg. lab
*Condition of curing and storage Water 71.5
humidity, %

IDENTIFICATION TEST RESULTS NOTES / REMARKS


Cube Size (mm) Failure Location of Condition
Concrete
Laboratory Cube grade Date Age Weight Density Maximum Compressive samples of Mode of
ref. no. ID Length Width Height Tested (days) (kg) (kg/m3 ) Load (kN) Strength description specimen failure
(N/mm2 ) etc. at test
(Calibrated) (N/mm2 )
R.C Wall &
R.C Wing
1251A 001 152.3 153.6 150.0 Grade 40 18/08/2023 7 8.3091 2370 925.2 39.5 Saturated Satisfactory
Wall (Level 1)
Abutment A1
R.C Wall &
R.C Wing
1251B 002 152.4 150.0 152.2 Grade 40 18/08/2023 7 8.3096 2390 965.3 42.0 Saturated Satisfactory
Wall (Level 1)
Abutment A1
R.C Wall &
R.C Wing
1251C 003 152.1 150.0 153.3 Grade 40 18/08/2023 7 8.3069 2380 947.2 41.5 Saturated Satisfactory
Wall (Level 1)
Abutment A1
R.C Wall &
R.C Wing
1251D 004 154.2 155.1 152.3 Grade 40 08/09/2023 28 8.5157 2340 1150.7 48.0 Saturated Satisfactory
Wall (Level 1)
Abutment A1
R.C Wall &
R.C Wing
1251E 005 153.0 153.6 150.0 Grade 40 08/09/2023 28 8.3643 2370 1102.8 47.0 Saturated Satisfactory
Wall (Level 1)
Abutment A1
R.C Wall &
R.C Wing
1251F 006 152.1 152.8 152.3 Grade 40 08/09/2023 28 8.1086 2290 1071 46.0 Saturated Satisfactory
Wall (Level 1)
Abutment A1

Remarks : -

Page 1 of 2
APPROVED SIGNATORY
(MUHAMAD AQMAL HAZIZI BIN HILL
JUNAIDI)

This Test Report remains the property of the JKR Laboratory; no corrections / amendments are to be made and it shall not be reproduced in part without prior
Note
written consent from the Lab Management
The Lab is not responsible for the correctness of sampling/ preparation and curing of cubes. Cubes information (including grade and casting date) are provided by
customer. This test results applies the the sample as received only
Disclaimer
i) * This information is provided by the customer
ii) # This information is provided by the customer and can have an significant effect on the test results

--- End of Report ---