Program
User's manual
Saint-Petersburg
2015
CONTENTS
1 Program View.......................................................................................................... 3
1.1 Change Of Size And Position Of Window Showing Measured Thickness .... 3
1.2 Changing Of Units Of Measurement Along Axes Of Time And Amplitude . 4
1.3 Setting Of Parameters Of Signal Generation, Processing And Display ......... 5
1.3.1 Agc Switching On/Off ...................................................................... 6
1.3.2 Selection Of Thickness Measurement Mode And Number Of
Strobes ........................................................................................................... 6
1.3.3 Accumulations Number Selection .................................................... 8
1.3.4 Waveform (A-Scan) View Selection ................................................ 9
1.3.5 Selection Of Number Of Pulses In Burst .......................................... 9
1.4 Results Saving ............................................................................................... 10
1.5 A-Scan Scaling And Movement ................................................................... 11
2 «Thickness Measure» Menu.................................................................................. 12
2.1 Thickness Measurement Mode ..................................................................... 12
2.2 Flaw Detector Mode ...................................................................................... 12
2.3 Calibration Mode .......................................................................................... 14
2.3.1 Selection Of Material From List ..................................................... 14
2.3.2 Calibration Using Specified Thickness .......................................... 15
2.3.3 Calibration Using Specified Acoustic Speed .................................. 15
3 «Presets» Menu ..................................................................................................... 17
+7(812) 385-54-28
[email protected] 2
ScanView Program. User’s Manual
1 PROGRAM VIEW
The ScanView program starts automatically when the EM2210 thickness gauge
is connected to a tablet or other device with the program installed. The user can start
the program manually too. At the first start a window shown in Fig. 1 opens. At the
next starts the program opens the window on which it was closed.
+7(812) 385-54-28
[email protected] 3
ScanView Program. User’s Manual
By default, the “Small” window size is set. Three options for size of the
window showing measured thickness are shown in Fig. 3.
+7(812) 385-54-28
[email protected] 4
ScanView Program. User’s Manual
+7(812) 385-54-28
[email protected] 5
ScanView Program. User’s Manual
Fig. 5. How to open and hide the settings menu for the parameters of signal generation, processing and
display
+7(812) 385-54-28
[email protected] 6
ScanView Program. User’s Manual
After selection of this mode, one strobe appears on the screen. The user can
move the strobe along the A-scan and change its length. The example of the window
with the strobe is shown in Fig. 8.
+7(812) 385-54-28
[email protected] 7
ScanView Program. User’s Manual
To move the strobe, touch the centre of the strobe and move the strobe to the
desired position holding the touch. To change the length of the strobe, touch the
centre of the strobe by one finger and move the other finger horizontally across the
screen (see Fig. 8).
The position of the maximum found in the strobe is displayed in the upper left
corner of the screen (see Fig. 9).
+7(812) 385-54-28
[email protected] 8
ScanView Program. User’s Manual
+7(812) 385-54-28
[email protected] 9
ScanView Program. User’s Manual
To change the number of pulses in the burst, touch the “Pulse count” button in
the settings menu. Then in the opened window shown in Fig. 12 select the required
number of pulses.
Fig. 12. Selection of the number of pulses in the burst of the probing signal
As a result, the window shown in Fig. 14 opens and the user can enter the name
of the file and select the file format: text file *.crv, picture *.png or both. To select
the file format, check the corresponding box.
+7(812) 385-54-28
[email protected] 10
ScanView Program. User’s Manual
The files are stored in “MyFiles” directory in a subfolder with the operator
name. The operator name and working directory can be changed in the program
settings (see paragraph 3).
+7(812) 385-54-28
[email protected] 11
ScanView Program. User’s Manual
The window allows the user to choose one of three measurement modes:
Thickness measurement mode (default setting);
Calibration mode;
Flaw detector mode.
+7(812) 385-54-28
[email protected] 12
ScanView Program. User’s Manual
In the flaw detector mode there are two windows located one under another:
Top window displays A-scan and two strobes;
Lower window displays a “P” parameter.
Search of the presence of the pitting corrosion is carried out for a test object of
a fixed thickness. The first strobe must be located so that it overlaps the first back-
wall echo. The second strobe must be located between the first and second back-wall
echoes so that it does not overlap them.
The “P” parameter is the ratio of the amplitude of the second strobe maximum
to the amplitude of the first strobe maximum. In the absence of defects, this ratio is
close to 0 since there are no echo signals between the back-wall echoes. In the
presence of a defect corresponding to the pitting corrosion, the amplitude of the back-
wall echo decreases and weak signals appear between the back-wall echoes due to
reflection from the defect. In this case, the value of the “P” parameter increases.
There are two thresholds that can be set by the user (red and yellow triangles)
in the lower window. Exceeding the threshold due to the presence of a defect is
accompanied by an audio warning. Sound for the thresholds can be set in the program
settings.
+7(812) 385-54-28
[email protected] 13
ScanView Program. User’s Manual
+7(812) 385-54-28
[email protected] 14
ScanView Program. User’s Manual
The EM2210 measures thickness using shear wave. The typical value of the
propagation speed of a shear wave in steel is 3250 m/s.
The program allows the user to add materials to the list.
2.3.2 Calibration using Specified Thickness
To calibrate the acoustic speed using the specified thickness of the test object,
place the EM2210 thickness gauge on a test sample with the specified thickness.
Then touch the “Value” label in the window shown in Fig. 18. As a result, the
window shown in Fig. 20 opens.
Enter the specified thickness of the test object in the window using the virtual
numeric keypad and touch the “OK” button. In this case, the program calculates the
acoustic speed of the material and saves it to the EM2210 memory.
CAUTION!
To increase the accuracy of calibration, increase the number of accumulations (see
paragraph 1.3.3).
2.3.3 Calibration using Specified Acoustic Speed
To calibrate the EM2210 using the specified acoustic speed, touch the “Speed”
label in the window shown in Fig. 18. As a result, the window shown in Fig. 21
opens.
+7(812) 385-54-28
[email protected] 15
ScanView Program. User’s Manual
Enter the specified acoustic speed for the material of the test object in the
window using the virtual numeric keypad and touch the “OK” button. In this case, the
program saves acoustic speed value to the EM2210 memory.
CAUTION!
The EM2210 measures thickness using shear wave. The typical value of the
propagation speed of a shear wave in steel is 3250 m/s.
+7(812) 385-54-28
[email protected] 16
ScanView Program. User’s Manual
3 «PRESETS» MENU
To open the main program settings menu, touch the “Settings” button with the
finger (see Fig. 22). As a result, the window shown in Fig. 23 opens.
The window allows the user to set the following program settings:
Operator name (account name);
Name of the working directory where the monitoring results are saved;
Colour for A-scan and strobes displaying;
Alarm sound of exceeding the thresholds for the flaw detector mode.
To switch from the setting mode to the measurement mode touch the
“Measure” button.
+7(812) 385-54-28