Anaesthesia Workstation
.- :~
_,,
--·
;._.
__
,,_ -
;;
- - ~::
Meditec Enaland
•
At Meditec England we recognize the demands and requirements of the Anaesthetist in the Operating Theatre, and have
taken these into consideration when developing the all-new NeptunePLUS Anaesthesia Workstation. The NeptunePLUS
excels in performance and offers complete flexibility to the Anaesthetist.
• NIST inlets for piped medical gases for 0 2 , N2 0 & Air as standard
• Single Bi-stable system ON I OFF switch for gases & power supply
• Pull out writing table
• Common gas outlet (CGO)
• Open/Close change over switch for convenient switch-over from open to closed system
• Suitable for open, semi-open & closed circuit system application
Auxiliary 0 2 Flowmeter
• Electrical outlets for running other medical equipment (Standard)
• Auxiliary 0 2 outlet with flowmeter as standard
Vaporiser
• Calibration range : 0 to 5% and Oto 8% using a Laser Refractometer.
• Easy to turn dials for Safety Lock to prevent accidental turn on.
.
Features
• High-luminance and wide display • Integrated Pressure, Volume and Oxygen monitoring
• 10.1" Touch screen • Self test, leak test and compliance test
• Ventilation modes: VCV, PCV, SIMV-V, SIMV-P, PSV, • Adult to pediatric mode
SPONT & Manual
• Waveforms: Flow-Time, Volume-Time
• Monitoring Parameters (Measured Values) VT,
• Spirometry Loops: Flow-Volume, Volume-Pressure
Frequency, Fi0 2 , Ppeak, MV , PEEP, Cdyn
• Setting Parameters
• Tidal volume range from 20ml to 1500ml suitable for
VT (Tidal Volume), Frequency, l:E ratio, Tip
Adult , Pediatric &Neonates
(lnspiratory pause time), Pmax, PEEP, Vsens
• Volume compensation and electronic PEEP (Triggering flow sensitivity), SIGH, Tapn, Ptrig
Automatically compensates for fresh gas flow, (Pressure trigger) Plimit, Psupp.
system leak and the compliance change in the circuit
• Alarm Parameters
• Ascending bellows provides immediate visual Continuous Positive Airway Pressure, Airway
information on the adequacy of fresh gas flow and pressure (high & low), Fi0 2 (high & low), MV (high &
gives an indication of any system leak low) , Frequency (high & low), Apnea, NC failure,
Battery low, Self-test failure, 0 2 failure alarm
• Cardiac By-Pass mode
[-.:.:.: -- ~ :._
The Neptune range offers a wide choice of
I- - ~;;;
Monitoring Systems with availability of optional
extended parameters such as AG, BIS, ICG , CO,
4 x IBP, EEG , Para-magnetic 0 2
- ECG EtC0 2
- NIBP - AG ,,
- Sp0 2 - co
- 2xTEMP - IBP
- RESP - BIS
TECHNICAL SPECIFICATIONS
Storage Space Two spacious drawers to hold essential anaesthesia kit and accessories
Castors Large roller bearing anti-static castors with front brakes
Writing Surface Pull out writing table on top of the drawers
.. Monitor Shelf Wide monitor shelf at eye level with securing provision for extra monitor
Cylinder Yokes Color coded gas specific (pin indexed) yokes with sliding stainless steel clamping bars for easy handling.
Holding 0 2 and N,O, 5Ltr water capacity cylinders
Non-return I Minimises risk of back flow of gases , blows off when pressure exceeds 125 CmH 20
Pressure Relief Valve
Regulators Designed for higher efficiency, long service life and reliability for 0 2 and N,O
Oxygen Flush Emergency oxygen flush switch at table level to give 35-70 Ltrs/min for emergencies
0 2 failure warning alarm Self activated electro-pneumatic audio visual warning device to indicate drop in 0 2 pressure below 2.5 Bar
Hypoxic Guard Mixing device to proportion the N,O in such a way that minimum of 25% 0 2 is always delivered in the gas
mixture
Common Gas Outlet (CGO) Conveniently located CGO with ISO tapers for 22 & 15mm connections
Basal flow with On/off Switch 250 ± 50 ml basal flow of Oxygen as soon as machine is switched on (optional)
Pipe Line Gas Inlets Non-interchangeable screw threaded (NIST) pipeline inlets one each for 0 ,, N,O and Air. In case of drop in
piped gas pressure the pin index cylinders take over automatically
Pressure Gauges Large diameter, color coded gauges fitted at convenient angle for better visibility and clarity. One for each of
the pin indexed yokes and one each corresponding to piped gas inlet
Selectatec Brackets Twin Selectatec Block
Breathing Circuits Bains Circuit & Circle Absorber Y-Circuit provided as standard
Certification CE and ISO Certification
Pressure Limit 10-65 cmH 20 Power 100-240 VAC, 50/60 Hz, 6.5A (Max.)