LM-700 焦度计英文 说明书 SUPORE 2018年4月21日
LM-700 焦度计英文 说明书 SUPORE 2018年4月21日
1 Product introduction
LM-700 can measure the degree of single vision lens, double vision
lens, three visions lens and progressive lens (PPL)quickly and precisely.
This machine has LCD touch screen, on which can show the measured data
and PD of left and right eyes. And it also can show the centering by diagram
marks on the screen and it can help to adjust the optical center of lens
quickly. The 7-inch high-resolution TFT touch screen can show everything
There is brief menu. Just pressing the keys on the screen, the graphs
LM-700 is the auto lens meter which is specialized for lens measurement.
Model LM-700
Sphere √
Cylinder √
Prism √
Progressive √
Color lens √
PD,PH √
Print √
Remarks With PD,PH and Print
1
Auto lens meter operation manual
2 Safe Notice
In this manual, the following marks mean the safe notice, please refer to
the follow:
Notice:
● Don’t open or touch the inner part of machine if not necessary, or it may cause
electric shock or make problem to machine.
● To use the stipulated voltage, if too high or too low, it will influence the
operation or even cause damage to machine or result in electric shock.
● Don’t put the wires under machine, or it will break the wires and cause
cutting-out, fire disaster or electric shock.
● If the metal core of wires is exposed, it should be exchanged right
away,otherwise, it will cause fire disaster or electric shock.
2
Auto lens meter operation manual
Notice:
● Don’t put the machine at some place humid or poisonous or with corrosive
liquid or air.
2.3 搬动时应注意的事项
● Don’t put machine under the sunshine. To keep the suitable temperature and
humidness.
● Notice: if the change of the outside temperature is too big, it will influence the
operation of machine. Then it just need to put machine under the stable
temperature for 3-10 hours, then it can be operated normally.
● Don’t pull the wires or cable, which will damage the machine or hurt people.
● Don’t take machine by seizing the LCD screen when moving machine. You
should hold the base by hands. Or it will hurt people or damage machine.
Notice:
● Don’t put machine in humid place. Any water into machine will cause electric
shock or other machine problem.
● To put machine at smooth place. Any shake during operation will make
machine fall down and may hurt people or damage machine.
3
Auto lens meter operation manual
Notice:
● Don’t operate machine under sunshine or near filament lamp. Don’t install
machine on the place that the surface with strong light reflect, like glass show
box, mirror or polishing desk. Otherwise, these situation will influence the
operation or make error.
● Don’t operate machine at the place against electric fans or air conditioner,
otherwise the dust will be flowed into machine which will influence the
preciseness of measured data.
● Don’t operate the machine at the place with dust or humid and hot, which
will influence operation.
Notice:
● Don’t put too many plugs on one power socket, which will make it too hot and
cause fire disaster.
● There must be ground connection to the power supply to protect the security of
people and machine.
4
Auto lens meter operation manual
Notice:
● To cut off power supply when not run the machine, and put on the dust cover.
Long time connection to power supply will short the usage life of machine. And
without dust for long time, the falling dust will influence the preciseness of
machine.
● Not operate machine for long time, please pull the plug out from power socket,
in case to prevent from fire disaster.
Notice:
● If there is any problem with machine and need to take down the machine for
check, please contact with our agent or our branch office. You need to take all
the responsible to any damage to machine from your personal action to it.
● Don’t scrape the protecting lens which under the lens base, otherwise it will
very influence the preciseness of measured data.
Notice:
● If the LCD screen broken, to knock it into pieces and wash and sweep them
away by alcohol, then to burn them down. If hands touch the liquid crystal, then
to wash hands with water right away. 5
Auto lens meter operation manual
6
Auto lens meter operation manual
3 Introduction to machine
Indicator light
Point button
lens fixing
frame
printer
Lens base
Memory switch
● lens fixing frame: when fixing the lens, to up the frame and down it
with gentle. When take down lens, to up the frame till there is a sound
● Sliding nose frame: which used for measuring PD. To put the nose pad
7
Auto lens meter operation manual
on the frame and move the frame, the PD will be measured out
automatically.
Port
Out power
injection
Fuse cover
FUSE:F2AL250V
USB
connection
● Lens base: which used for putting lens and as the basic point of
measurement. Dust cover: which used for protecting machine from dust.
off machine.
8
Auto lens meter operation manual
● Point button: to mark the center of lens and the optical axis of
astigmatism glasses.
● Lens table button: to dolly moves lens and measure the diameter of lens
(the diameter can be read out by the degree scale under the button.)
● lens table: to fix the direction of lens frame. To put the bottom of
lens frame on the lens table when make the measurement. Don’t move the
Note: no operation for some time, machine will turn to screen saver mode.
The time of this mode can be set in Menu. Back to measure mode, just gentle
L/ R
PD
PH
Time
9
Auto lens meter operation manual
Drone
十:Off center
L/ R
When the left side or right side (L/ R) has been set and the mark showed
up, the degree of the side will be showed under the mark.
PD
10
Auto lens meter operation manual
UV measurement interface
following
Menu shows:
After entering into Menu, to press the corresponding button to change the
11
Auto lens meter operation manual
Step 0.01D,0.12D,0.25D
Cylinder Mix,+,-
Prism No display,X-Y,P-B
10minutes
center
language ENGLISH,Chinese
12
Auto lens meter operation manual
ID setting Yes,no
4 Operation
4.1 Assembling
(1)to check the attached parts: after opening the package, to check all
(2)to find a smooth place without direct sunshine and put down machine
well.
(3)to connect with power supply: to plug the power output injection of
4.2 Test
(2)the test data should be 0D without any lens. To turn on the power so
Note: if all the data showed on measurement menu are not 0, then it means
that the protecting glass is dirty, which is in lens base. To blow off the
dust by the balloon. If it is still dirty, then to wipe it with lens cloth.
It should be cleaned every short time. Be sure to move lens base up while
13
Auto lens meter operation manual
4.3 Operation
In PD measuring, the sliding nose pad frame will direct the left
or right side and it will measure out the PD of left or right while
2、Lens settings
To put the lens on the lens base, and the convexity upward.
14
Auto lens meter operation manual
3、Lens fixing
To move lens to make the drone(十) to the center. When the distance
between the drone and center less than 0.5△,the shape of the drone will
be as a cross (十);When the drone at the very place at center, the shape
of the drone will be a thicker cross(十). There are two ways to confirm
A:to press the memory key and the data will be saved. When data be saved,
the direction type of astigmatism +/- can be changed. To press clear key,
according to the settings, then there is no need to press memory key anymore,
and the direction type of astigmatism +/- can be changed. To press clear
15
Auto lens meter operation manual
Normal measurement
(1)to press L/ R key to move the drone (十) to the center. When the
distance between the two less than 0.5△, the shape of the drone will be
shape will be a thicker cross (十). To press memory key (or automatical
16
Auto lens meter operation manual
(2)to press L/ R key to measure the other lens, and repeat action(1).
Figure 4.4 measurement of finished lens and save the data of left side
(3)to rotate the lens table knob to move the lens table till touch the
bottom of lens frame, and move sliding nose pad frame to the center of lens
frame. To move the lens to make the drone(十) close to the center,when the
distance between the two less than 0.5△, the shape of the drone will be
shape will be a thicker cross (十). To press memory key (or automatical
17
Auto lens meter operation manual
Figure 4.5 measurement of finished lens and save the data of left and
right side
(4)to check the other lens, to move the sliding nose pad frame along with
no need to set the Abbe number when measure the high index lens. The measured
18
Auto lens meter operation manual
4、to press print, then the machine will print out the data.
(1) To put the far vision part(far vision range) of lens on the lens base.
19
Auto lens meter operation manual
Figure 4.8 measurement of far vision range and measured data saving
When the shape of the drone as (十)or (十), to press the Memory key, then
To move the lens toward yourself till the near vision part(near vision
range) of the lens on the lens base. To press Mode, there will be AD1 on
the screen. When the notice showed under the drone as “close to the
Memory , then the measured data of near vision part will be confirmed. And
20
Auto lens meter operation manual
The way to measure far vision part of three vision lens and double vision
a. To move the lens toward yourself till the center of near vision part
on the lens base. Then to press Mode, there will be AD1 showed on the screen.
When the notice showed under the drone as “close to the center”(there
is no need to focus the center perfectly), to press the Memory , then the
measured data of the center of near vision part will be confirmed. Then
b. To move the near vision part to the lens base, then press Mode, there
will be AD2 showed on the screen. When the notice showed under the drone
to press the Memory , then the measured data of near vision part will be
confirmed.
21
Auto lens meter operation manual
To press the lens mode exchange key to enter into the PPL measuring
mode. During this measurement, the Memory key should be used. There are
To mark the lens with the special eyes ports supplied by manufacturer
and make the lens convexity upward. In the near vision range, to keep the
horizontal reference line in horizontal and lock the lens. To measure the
far vision range first, and to move the lens up and down and from left to
right to make the drone just on the center of the cross line. When the drone
as the thicker cross (十), and to press the Memory key, the data of far
vision range be confirmed. Then to move lens till the near eyes ports on
the lens base, there will be ADD and measured data showed on screen, just
22
Auto lens meter operation manual
There is no marks for range on lens when measure with the progressive screen. So be
(2)to measure the parameter of the far vision range. The center of far vision range is
close to the center of the frame. The measuring way is same as that of item 6 above.
23
Auto lens meter operation manual
To move the lens with frame by moving the knob and dam-board outward. The optical
center of near vision range is close to the center of frame, to find the optical center of
near vision range by moving it from left to right. Watching the ADD on the screen, to
(1) to point out the pupil center: to let customer to wear glasses and
look into the distance, and point out the pupil center on every lens.
Note: the diameter of the point should be smaller than 1mm. If too bigger,
D 0.03cm/m 0°
(4)Lens settings
24
Auto lens meter operation manual
(6) to put one eyes ports on the center of lens base(no need for center
focusing).
(7) to press the Memory key (Note: if data with error, it means that the
eyes ports is just on the measuring optical. It just needs to move the lens
(1) to move the drone(+) to the center cross line, the shape of drone
will be turned to the thicker one(十). If it is the lens with frame, then
(2)to make the astigmatism axis to show the data: to rotate the lens
till there shows the data, which will be showed through axis. If the thicker
(3)to make the data of prism lens: to make the data of prism same as
that of the matchable lens. When choose the rectangular coordinates, the
“I” on screen mean inward, “O” means outward, “D” means downward,
“U” means upward. To put the measured lens on the lens base, with gentle
rotation to make the basic prism data same as the data if the matchable
lens.
(4)to mark on lens: to rotate the point button, and to mark out the
three points on lens which in the same horizontal line of lens table. When
25
Auto lens meter operation manual
take the lens down, to up the lens fixing frame till there is a “KA” sound,
then to take the lens. (Don’t touch the marks, otherwise they will be not
clear.)
5 Maintenance
( 4)To keep machine clean. Don’t use the organic solution like
(5)No operation for long time, to cut off power supply and pull out
the plug;
(6)To put on the dust cover when not use the machine.
26
Auto lens meter operation manual
(1) open the printer cover plate, place printing paper and then cove
r the printer
(1) when machine is dirty, please wipe machine with soft dry cloth. If
there is any dirty spot, to wipe by cloth with neutral detergent then clean
(2) to clean the protecting glass by balloon to blow away the dust. If
it is still dirty, to wipe it with clean dry cloth. To clean the protecting
glass regularly and move up the lens base when clean it.
The lens base should be taken down while turning off machine and clean
the light transfer glass, then to put on the lens base and turn on machine
to calibrate again (Below is the clean to the light transfer glass after
27
Auto lens meter operation manual
(3) to hold machine by hands from the base of machine and move machine;
(1)maintenance
Anything problem with machine can not be settle according to the manual,
Machine : LM-700
better choice )
28
Auto lens meter operation manual
pollution;
● Before your action with the useless machine, please contact with
29
Auto lens meter operation manual
30
Auto lens meter operation manual
7 Performance parameter
Figure 7.1 performance parameter
The range of measurement
Sphere 0m-1to±25m-1
Cylinder 0m-1to±10.00m-1
Astigmatism 0° to 180°
measurement range
Dioptric (0.01/0.12/0.25)m-1
Prism (0.01/0.12/0.25)cm/m
Mode of measurement
Cylinder +,±,-
Prism X-Y,P-B
Other parameters
31
Auto lens meter operation manual
Power 25VA
32