LS - Catalogue - Fire Alarm Cable - Final
LS - Catalogue - Fire Alarm Cable - Final
Contents
Unshielded Fire Alarm Cable.……………….................................. 4
Shielded Fire Alarm Cable……………………................................ 6
Unshielded Flame Retardant Fire Alarm Cable………………........ 8
Shielded Flame Retardant Fire Alarm Cable…………………….... 10
Unshielded Fire Resistant Fire Alarm Cable.................................. 12
Shielded Fire Resistant Fire Alarm Cable………………………….. 14
Enable The Cable World!
UNSHIELDED FIRE ALARM CABLE
Descriptions
1
• Multipair twisted cable
• Conductor: IEC 60228 (Class 2 other options are available
pon request) or ASTM (B 3/B 33)
• XLPE/PVC/LSZH insulation and PVC/LSZH Jacket (other
options are available upon request)
• Packaged on Wooden Reel
2 • RoHS compliant
3
Application
• Fire Alarm systems, Public Address, BMS
• Internal wiring of electronic equipment, transmission
measurement and control signals with minium noise
• Inducstrial, Interconnect
1 - Insulated Conductor • Optimized for Analogue Audio System
2 - Insulation
Cable Properties
Conductor
Insulation Shield Drain wire Jacket
Stranded Copper
Maximum Conductor
Cable Counts Mica Tape Tinned strand Resistance at 20°C
mm2 No./mm Thickness (mm) Aluminium Tape copper wire Thickness (mm) Color (Ω/km)
No./mm
Part Numbers
Part Number Description
LS - FA - C A B - XX - YYY
Color Table
Twist Pair (*) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White
Twist Cores (**) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black Red White Green Blue Yellow Brown Orange
Descriptions
1
• Multipair twisted cable with Aluminum Mylar Tape shield
and drain wire
• Conductor: IEC 60228 (Class 2 and other options are
available upon request) or ASTM (B 3/B 33)
2 • PVC/XLPE/LSZH insulation and PVC/LSZH Jacket (other
options are available upon request)
5
Application
• Fire Alarm systems, BMS
• Internal wiring of electronic equipment, transmission
measurement and control signals with minium noise
• Inducstrial, Interconnect
• Optimized for Public Address systems
1 - Insulated Conductor
2 - Drain Wire
Technical Details
3 - Insulation
• Working Voltage: 300/500 V
• Test Voltage (AC) No Breakdown: 2.0kV/5min
4 - Aluminum Tape
• Operating Temperature: -40 – 90 °C
• Insulation resistance: Min. 2.0 G Ω . km
5 - Jacket
Cable Properties
Conductor
Insulation Shield Drain wire Jacket
Stranded Copper
Maximum Conductor
Cable Counts Mica Tape Tinned strand Resistance at 20°C
mm2 No./mm Thickness (mm) Aluminium Tape copper wire Thickness (mm) Color (Ω/km)
No./mm
Part Numbers
Part Number Description
LS - FA - C A B S - XX - YYY
Color Table
Twist Pair (*) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White
Twist Cores (**) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black Red White Green Blue Yellow Brown Orange
Descriptions
• Multipair twisted cable
1
• Conductor: IEC 60228 (Class 2 or other options are
available upon request) or ASTM (B 3/B 33)
• PVC/XLPE/LSZH insulation and Fr-PVC/LSZH Jacket
(other options are available upon request)
• Packaged on Wooden Reel
• RoHS compliant
• Compliant to IEC 60332-1
2
Application
3
• Optimized for Fire Alarm systems
• Internal wiring of electronic equipment, transmission
measurement and control signals with minium noise
• Inducstrial, Interconnect
• Public Address, BMS systems
1 - Insulated Conductor
2 - Insulation
Technical Details
3 - Jacket
• Working Voltage: 600/1000 V
• Test Voltage (AC) No Breakdown: 3.5kV/5min
• Operating Temperature: -40 – 90 °C
• Insulation resistance: Min. 2.0 G Ω . km
Cable Properties
Conductor
Insulation Shield Drain wire Jacket
Stranded Copper
Maximum Conductor
Cable Counts Mica Tape Tinned strand Resistance at 20°C
mm2 No./mm Thickness (mm) Aluminium Tape copper wire Thickness (mm) Color (Ω/km)
No./mm
Part Numbers
Part Number Description
LS - FA - C A B - XX - YYY
Color Table
Twist Pair (*) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White
Twist Cores (**) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black Red White Green Blue Yellow Brown Orange
Descriptions
• Multipair twisted cable with Aluminum Mylar Tape shield
1
and drain wire
• Conductor: IEC 60228 (Class 2 or other options are
available upon request) or ASTM (B 3/B 33)
• PVC/XLPE/LSZH insulation and Fr-PVC/LSZH Jacket
4
Application
5
• Optimized for Fire Alarm systems
• Internal wiring of electronic equipment, transmission
measurement and control signals with minium noise
• Inducstrial, Interconnect
• Public Address, BMS systems
1 - Insulated Conductor
Technical Details
2 - Drain Wire
• Working Voltage: 600/1000 V
3 - Insulation • Test Voltage (AC) No Breakdown: 3.5kV/5min
• Operating Temperature: -40 – 90 °C
4 - Aluminum Tape • Insulation resistance: Min. 2.0 G Ω . km
5 - Jacket
Cable Properties
Conductor
Insulation Shield Drain wire Jacket
Stranded Copper
Maximum Conductor
Cable Counts Mica Tape Tinned strand Resistance at 20°C
mm2 No./mm Thickness (mm) Aluminium Tape copper wire Thickness (mm) Color (Ω/km)
No./mm
Part Numbers
Part Number Description
LS - FA - C A B S - XX - YYY
Color Table
Twist Pair (*) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White
Twist Cores (**) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black Red White Green Blue Yellow Brown Orange
Descriptions
• Multipair twisted cable with Mica Tape
1
• Conductor: IEC 60228 (Class 2 or other options are
available upon request) or ASTM (B 3/B 33)
2 • PVC/XLPE/LSZH insulation and Fr-PVC/LSZH Jacket
(other options are available upon request)
• Packaged on Wooden Reel
• RoHS compliant
• Compliant to IEC 60331 and BS 6387 CWZ
3
Application
4
• Optimized for Fire Alarm systems
• Internal wiring of electronic equipment, transmission
measurement and control signals with minium noise
• Inducstrial, Interconnect
• Public Address, BMS systems
1 - Insulated Conductor
Technical Details
2 - Mica Tape
• Working Voltage: 600/1000 V
3 - Insulation • Test Voltage (AC) No Breakdown: 3.5kV/5min
• Operating Temperature: -40 – 90 °C
4 - Jacket • Insulation resistance: Min. 2.0 G Ω . km
Cable Properties
Conductor
Insulation Shield Drain wire Jacket
Stranded Copper
Maximum Conductor
Cable Counts Mica Tape Tinned strand Resistance at 20°C
mm2 No./mm Thickness (mm) Aluminium Tape copper wire Thickness (mm) Color (Ω/km)
No./mm
Part Numbers
Part Number Description
LS - FA - C M A B - XX - YYY
Color Table
Twist Pair (*) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White
Twist Cores (**) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black Red White Green Blue Yellow Brown Orange
Descriptions
• Multipair twisted cable with Mica Tape, Aluminum Mylar
1
Tape shield and drain wire
• Conductor: IEC 60228 (Class 2 or other options are
2 available upon request) or ASTM (B 3/B 33)
• PVC/XLPE/LSZH insulation and PVC/Fr-PVC/LSZH Jacket
5
Application
6
• Optimized for Fire Alarm systems
• Internal wiring of electronic equipment, transmission
measurement and control signals with minium noise
• Inducstrial, Interconnect
• Public Address, BMS systems
1 - Insulated Conductor
2 - Mica Tape
Technical Details
3 - Drain Wire
• Working Voltage: 600/1000 V
6 - Jacket
Cable Properties
Conductor
Insulation Shield Drain wire Jacket
Stranded Copper
Maximum Conductor
Cable Counts Mica Tape Tinned strand Resistance at 20°C
mm2 No./mm Thickness (mm) Aluminium Tape copper wire Thickness (mm) Color (Ω/km)
No./mm
Part Numbers
Part Number Description
LS - FA - C M A B S - XX - YYY
Color Table
Twist Pair (*) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black/Red Black/White Black/Green Black/Blue Black/Yellow Black/Brown Black/Orange Red/White
Twist Cores (**) 1st 2nd 3rd 4th 5th 6th 7th 8th
Color Black Red White Green Blue Yellow Brown Orange