Camesa EMC Catalog
Camesa EMC Catalog
PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.2 ft/Kft/Klbs (2.50 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 4.3 Ω/Kft (14.1 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,600 lbs (24.9 KN) Nominal
Maximum Suggested Working Tension: 2,800 lbs (12.5 KN)
Number and Size of Wires:
Inner Armor 15 x 0.0243” (0.617 mm)
Outer Armor 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 132 lbs (0.59 KN)
Outer Armor 286 lbs (1.27 KN)
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 2 23–July–10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342– 0531
9
PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.7 ft/Kft/Klbs (3.0 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 16.0 Ω/Kft (52.5 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,700 lbs (20.9 KN) Nominal
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 deg. F at low exposure to H2S + CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent; is applied between armor layers.
∗ The insulation temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
11
PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.9 ft/Kft/Klbs (3.30 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 22.0 Ω/Kft (72.2 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,200 lbs (23.0 KN) Nominal
Maximum Suggested Working Tension: 2,600 lbs (11.6 KN)
Number and Size of Wires:
Inner Armor 15 x 0.0243” (0.617 mm)
Outer Armor 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 125 lbs (0.56 KN)
Outer Armor 272 lbs (1.21 KN)
∗ The armor wires are made of UNS R30035 (MP35N), a nickel-cobalt corrosion resistant alloy steel and coated with
anti-corrosion compound for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23 – July – 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
10
PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 3.0 ft/Kft/Klbs (3.4 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 18.5 Ω/Kft (60.7 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,900 lbs (21.8 KN) Nominal
Maximum Suggested Working Tension: 2,450 lbs (10.9 KN)
Number and Size of Wires:
Inner Armor 15 x 0.0243” (0.617 mm)
Outer Armor 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 116 lbs (0.52 KN)
Outer Armor 252 lbs (1.12 KN)
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 425 deg, F, at medium levels of H2S & CO2
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342–0531
7
PROPERTIES:
Cable Diameter: 0.185” +0.004” -0.002” (4.70mm + 0.10mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 3.0 ft/Kft/Klbs (3.37 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC
Armor Electrical Resistance: 6.0 Ω/Kft (19.7 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,000 lbs (17.8 KN) Nominal
Maximum Suggested Working Tension: 2,000 lbs (8.9 KN) Nominal
Number and Size of Wires:
Inner Armor 12 x 0.0220” (0.559 mm)
Outer Armor 12 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 103 lbs (0.46 KN)
Outer Armor 272 lbs (1.21 KN)
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 2 23 –July – 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
5
PROPERTIES:
Cable Diameter: 0.101” +0.004” -0.002” (2.56mm + 0.10mm -0.05mm)
Minimum Shave Diameter: 6” (15 cm)
Cable Stretch Coefficient 13.1 ft/Kft/Klbs (14.72 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 300 VDC
Conductor AWG Rating 24
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 22.0 Ω/Kft (72.2 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 1,000 lbs (4.4 KN) Nominal
Maximum Suggested Working Tension: 500 lbs (2.2 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0140” (0.356 mm)
Outer Armor 18 x 0.0140” (0.356 mm)
Average Wire Breaking Strength:
Inner Armor 42 lbs (0.19 KN)
Outer Armor 42 lbs (0.19 KN)
• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
• Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at
68 deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
• SUPERSEAL a special pressure seal agent, is applied between armor layers.
• The temperature rating assumes a normal gradient for both temperature and weight.
• All values shown are nominal or typical values.
Rev: 2 23-July – 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
6
PROPERTIES:
Cable Diameter: 0.126” +0.004” -0.002” (3.20mm + 0.10mm -0.05mm)
Minimum Shave Diameter: 7” (18 cm)
Cable Stretch Coefficient 6.5 ft/Kft/Klbs (7.30 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 300 VDC
Conductor AWG Rating 24
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 13.0 Ω/Kft (42.6 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 1,600 lbs (7.1 KN) Nominal
Maximum Suggested Working Tension: 800 lbs (3.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0175” (0.444 mm)
Outer Armor 18 x 0.0175” (0.444 mm)
Average Wire Breaking Strength:
Inner Armor 65 lbs (0.29 KN)
Outer Armor 65 lbs (0.29 KN)
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 2 23-July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
12
PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 2.5 ft/Kft/Klbs (2.81 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 4.4 Ω/Kft (14.4 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,600 lbs (24.9 KN) Nominal
Maximum Suggested Working Tension: 2,800 lbs (12.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 215 lbs (0.96 KN)
Outer Armor 215 lbs (0.96 KN)
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
14
PROPERTIES:
Cable Diameter: 0.224” +0.005” – 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 3.1 ft/Kft/Klbs (3.5 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 18.1 Ω/Kft (59.4 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,900 lbs (21.8 KN) Nominal
Maximum Suggested Working Tension: 2,450 lbs (10.9 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 189 lbs (0.84 KN)
Outer Armor 189 lbs (0.84 KN)
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 425 F at medium levels of H2S & CO2.
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494; Fax (281) 342 – 0531
15
7/32” (5.69 mm)
MONOCONDUCTOR
1N22 - MP35N
CORROSION
RESISTANT
PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 2.9 ft/Kft/Klbs (3.30 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 22.0 Ω/Kft (72.2 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,200 lbs (23.0 KN) Nominal
∗ The armor wires are made of UNS R30035 (MP35N), a nickel-cobalt corrosion resistant alloy steel and coated with
anti-corrosion compound for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23 – July–10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Facsimile (281) 342 - 0531
13
PROPERTIES:
Cable Diameter: 0.224” +0.005” – 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 3.1 ft/Kft/Klbs (3.5 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 18.1 Ω/Kft (59.4 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,700 lbs (20.9.0 KN) Nominal
Maximum Suggested Working Tension: 2,350 lbs (10.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 181 lbs (0.81 KN)
Outer Armor 181 lbs (0.81 KN)
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494; Fax (281) 342 – 0531
7/32” (5.69 mm)
MONOCONDUCTOR
1N22
PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 2.5 ft/Kft/Klbs (2.81 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 4.4 Ω/Kft (14.4 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,200 lbs (23.1 KN) Nominal
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F.
∗ SUPERSEAL; a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
16
PROPERTIES:
Cable Diameter: 0.258” +0.005” - 0.002” (6.55mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 1.9 ft/Kft/Klbs (2.13 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 3.0 Ω/Kft (9.84 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 7,000 lbs (31.1 KN) Nominal
Maximum Suggested Working Tension: 3,500 lbs (15.6 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0358” (0.909 mm)
Outer Armor 18 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 272 lbs (1.21 KN)
Outer Armor 272 lbs (1.21 KN)
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL;,a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
17
1/4” (6.55 mm)
MONOCONDUCTOR
1N25 – S75
CORROSION
RESISTANT
PROPERTIES:
Cable Diameter: 0.258” +0.005” – 0.002” (6.55mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.3 ft/Kft/Klbs (2.60 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 16.5 Ω/Kft (54.13 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 6,000 lbs (26.7 KN) Nominal
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Facsimile (281) 342 - 0531
18
PROPERTIES:
Cable Diameter: 0.258” +0.005” - 0.002” (6.55mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.3 ft/Kft/Klbs (2.60 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 10.0 Ω/Kft (32.9 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 6,500 lbs (28.9 KN) Nominal
∗ Insulation is rated to 500°F, Armor wires are rated to 425°F at medium levels of H2S+CO2.
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F.
Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent; is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
19
PROPERTIES:
Cable Diameter: 0.288” +0.005” - 0.002” (7.32mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 16” (41 cm)
Cable Stretch Coefficient 1.55 ft/Kft/Klbs (1.74 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.8 Ω/Kft (9.2 Ω/Km)
MECHANICAL:
Cable Breaking Strength: 10,200 lbs (45.4 KN) Nominal
∗ The armor wires are Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection
during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, it is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
∗ Not recommended for use in any sour and / or corrosive environment.
Rev. 02 23–July–10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 – 0531
20
PROPERTIES:
Cable Diameter: 0.288” +0.005” – 0.002” (7.32mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 16” (41 cm)
Cable Stretch Coefficient 1.9 ft/Kft/Klbs (2.13 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 10.0 Ω/Kft (32.8 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 7800 lbs (34.7 KN) Nominal
Ends Free:
Maximum Suggested Working Tension: 3, 900 lbs (17.4 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0400” (1.016 mm)
Outer Armor 18 x 0.0400” (1.016 mm)
Average Wire Breaking Strength:
Inner Armor 302 lbs (1.34 KN)
Outer Armor 302 lbs (1.34 KN)
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA, INC. 1615 Spur 529 PO. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494; Fax (281) 342 – 0531
21
PROPERTIES:
Cable Diameter: 0.322” +0.005” - 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (46 cm)
Cable Stretch Coefficient 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed 11,400 lbs (50.7 KN) Nominal
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPER SEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
22
PROPERTIES:
Cable Diameter: 0.322” +0.005” – 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (46 cm)
Cable Stretch Coefficient 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 13
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 11,400 lbs (50.7 KN) Nominal
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPER SEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
23
PROPERTIES:
Cable Diameter: 0.322” +0.005” – 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (45 cm)
Cable Stretch Coefficient 1.6 ft/Kft/Klbs (1.8 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 11.2 Ω/Kft (36.7 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 9,700 lbs (43.2 KN) Nominal
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23– July – 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
24
PROPERTIES:
Cable Diameter: 0.322” +0.005” – 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (46 cm)
Cable Stretch Coefficient 1.6 ft/Kft/Klbs (1.8 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 11.2 Ω/Kft (36.7 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 9,700 lbs (43.2 KN) Nominal
∗ Insulation is rated to 500 deg. F. Armor wires are rated to 425 F at medium levels of H2S & CO2.
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68 deg.
F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev. 02 23 –July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
25
PROPERTIES:
Cable Diameter: 0.380” +0.006” - 0.002” (9.65mm + 0.15mm -0.05mm)
Minimum Shave Diameter: 21” (53 cm)
Cable Stretch Coefficient 1.0 ft/Kft/Klbs (1.12 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.5 Ω/Kft (4.92 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed 15,000 lbs (66.7 KN) Nominal
Maximum Suggested Working Tension: 7,500 lbs (33.4 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0525” (1.334 mm)
Outer Armor 18 x 0.0525” (1.334 mm)
Average Wire Breaking Strength:
Inner Armor 585 lbs (2.60 KN)
Outer Armor 585 lbs (2.60 KN)
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev:02 23 –July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Facsimile (281) 342 - 0531
26
PROPERTIES:
Cable Diameter: 0.425” +0.006” - 0.002” (10.80mm + 0.15mm -0.05mm)
Minimum Shave Diameter: 24” (61 cm)
Cable Stretch Coefficient 0.70 ft/Kft/Klbs (0.79 m/Km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 13
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.2 Ω/Kft (3.94 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 19,500 lbs (86.8 KN) Nominal
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F.
Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev:02 23 –July– 10
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
27
PROPERTIES:
Cable Diameter: 0.186” +0.004” - 0.002” (4.80 mm + 0.10mm - 0.05mm)
Minimum Shave Diameter: 10” (25 cm)
Cable Stretch Coefficient 4.25 ft/Kft/Klbs (4.78 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 300 VDC
Conductor AWG Rating 23
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 6.7 Ω/Kft (22.0 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 3,100 lbs (13.8 KN) Nominal
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of six wires around one center wire. Voids in the copper strand are filled with
a water-blocking agent to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax (281) 342-0531
28
5/16” (8.3mm)
7-CONDUCTOR
7H32
PROPERTIES:
Cable Diameter: 0.325” +0.005” - 0.002” (8.25mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (45 cm)
Cable Stretch Coefficient 1.8 ft/Kft/Klbs (2.02 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 22
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.3 Ω/Kft (7.5 Ω/Km)
MECHANICAL:
• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
• Core assembly – Conductors are bound with conductive tape and voids are filled with conductive filler and string.
Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
• The temperature rating assumes a normal gradient for both temperature and weight.
• Center conductor construction is 7×0.0100”. The typical resistance is reduced by approximately 5 to 10% and the
capacitance is increased by approximately 5 to 10% in comparison to the outer conductors.
• All values shown are nominal or typical values.
Rev: 02 23-July-10
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 777471 Phone (281)342-4494 Facsimile (281) 342-0531
30
7/16” (10.82mm)
7-CONDUCTOR
7H42–HS
PROPERTIES:
Cable Diameter: 0.426” +0.005” - 0.002” (10.82mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 24” (61 cm)
Cable Stretch Coefficient 0.75 ft/Kft/Klbs (0.84 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.2 Ω/Kft (3.9 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 17,600 lbs (78.3 KN) Nominal
Maximum Suggested Working Tension: 8800 lbs (39.2 KN)
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 7×0.0128”. The typical capacitance is decreased by approximately 5 to 10% in
comparison to the outer conductors.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax (281) 342-0531
33
0.474” (12.0mm)
7-CONDUCTOR
Extra High
Strength
7H47–EHS
PROPERTIES:
Cable Diameter: 0.474” +0.005” - 0.002” (12.04mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 26” (66 cm)
Cable Stretch Coefficient 0.61 ft/Kft/Klbs (0.69 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1100 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.1 Ω/Kft (3.6 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 24,500 lbs (109 KN) Nominal
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax. (281) 342-0531
33
0.474” (12.0mm)
7-CONDUCTOR
Extra High
Strength
7H47–EHS
PROPERTIES:
Cable Diameter: 0.474” +0.005” - 0.002” (12.04mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 26” (66 cm)
Cable Stretch Coefficient 0.61 ft/Kft/Klbs (0.69 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1100 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.1 Ω/Kft (3.6 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 24,500 lbs (109 KN) Nominal
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax. (281) 342-0531
0.474” (12.04mm)
7-CONDUCTOR
7H47RA-HSN
PROPERTIES:
Cable Diameter: 0.474” +0.005” - 0.002” (12.04mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 26” (66 cm)
Cable Stretch Coefficient 0.61 ft/Kft/Klbs (0.69 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1100 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.1 Ω/Kft (3.6 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 23,600 lbs (105 KN) Nominal
• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
• Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
• Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg.
F.
• The temperature rating assumes a normal gradient for both temperature and weight.
• Center conductor construction is 6×0.0142” with a non-conductive center member and insulated with PFA. The
typical resistance is 9.2 Ω/Kft and the typical Capacitance could be from 44 to 48 pF/ft.
**The value of the typical capacitance could be with a variation From 42 to 46 pF/ft.
CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax (281) 342-0531
31
15/32” (11.79mm)
7-CONDUCTOR
7J46
PROPERTIES:
Cable Diameter: 0.464” +0.005” - 0.002” (11.79mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 20” (51 cm)
Cable Stretch Coefficient 0.77 ft/Kft/Klbs (0.87 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.3 Ω/Kft (4.3 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 18,000 lbs (80.1 KN) Nominal
Maximum Suggested Working Tension: 9,000 lbs (40.0 KN)
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax: (281) 342-0531
32
15/32” (11.79mm)
7-CONDUCTOR
High Strength
7J46 - HS
PROPERTIES:
Cable Diameter: 0.464” +0.005” - 0.002” (11.79mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 20” (51 cm)
Cable Stretch Coefficient 0.77 ft/Kft/Klbs (0.87 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.3 Ω/Kft (4.3 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 19,100 lbs (85.0 KN) Nominal
Maximum Suggested Working Tension: 9,550 lbs (42.5 KN)
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax: (281) 342-0531
29
3/8” (9.60mm)
7-CONDUCTOR
7Q38 – HS
PROPERTIES:
Cable Diameter: 0.378” +0.005” - 0.002” (9.60mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 19” (48 cm)
Cable Stretch Coefficient 1.4 ft/Kft/Klbs (1.57 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.8 Ω/Kft (5.9 Ω/Km)
MECHANICAL:
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 7×0.0128”. The typical capacitance is decreased by approximately 5 to 10% in
comparison to the outer conductors.
∗ All values shown are nominal or typical values.
REV. 1 23–July–10
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax (281) 342-0531
34
0.484” (12.29 mm)
7-CONDUCTOR
Extra
High Strength
7Q48
PROPERTIES:
Cable Diameter: 0.484” +0.006” - 0.003” (12.29mm + 0.15mm -0.076mm)
Minimum Shave Diameter: 27” (69 cm)
Cable Stretch Coefficient (Nominal): 0.61 ft/Kft/Klbs (0.69 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.00 Ω/Kft (3.3 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 27,100 lbs (120.6 KN) Nominal
CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax: (281) 342–0531
36
0.490” (12.45mm)
7-CONDUCTOR
Extra-Extra
High Strength
7Q49 – EEHS
PROPERTIES:
Cable Diameter: 0.490” +0.006” - 0.002” (12.45mm + 0.15mm -0.051mm)
Minimum Shave Diameter: 25” (64 cm)
Cable Stretch Coefficient (Nominal): 0.60 ft/Kft/Klbs (0.67 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.00 Ω/Kft (3.3 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 29,500 lbs (131.3 KN) Nominal
CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg. Texas 77471 Phone (281)342–4494 Fax (281) 342–0531
35
0.490” (12.45mm)
7-CONDUCTOR
Extra
High Strength
7Q49 – EHS
PROPERTIES:
Cable Diameter: 0.490” +0.006” - 0.002” (12.45mm + 0.15mm -0.051mm)
Minimum Shave Diameter: 25” (64 cm)
Cable Stretch Coefficient (Nominal): 0.60 ft/Kft/Klbs (0.67 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.00 Ω/Kft (3.3 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 25,750 lbs (114.6 KN) Nominal
CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg. Texas 77471 Phone (281)342–4494 Fax (281) 342–0531
37
0.521” (13.23mm)
7-CONDUCTOR
7Q52
PROPERTIES:
Cable Diameter: 0.521” +0.007” - 0.003” (13.23mm + 0.18mm -0.076mm)
Minimum Shave Diameter: 26” (67 cm)
Cable Stretch Coefficient (Nominal): 0.58 ft/Kft/Klbs (0.65 m/km/5KN)
ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 0.85 Ω/Kft (2.8 Ω/Km)
MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 25,500 lbs (113.5 KN) Nominal
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
∗ All values shown are nominal or typical values.
Rev: 02 23-July– 10
CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone (281) 342–4494 Fax: (281) 342–0531
38
DYCAM
CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
Swab and dycam min sheave
Min.
sheave Ø
P. O. Box 1048, 1615 Spur 529, Rosenberg, TX 77471 Tel. 281-342-4494 Fax. 281-342-0531
Email: [email protected]
39
SWAB LINES
MECHANICAL CHARACTERISTICS
Breaking Strength 13.9 Klb 21.6 Klb
Maximum Suggested Tension 6.9 Klb 10.8 Klb
Weight (207.6 lb/Kft) (394 lb/Kft)
Diameter Tolerance +--2%
Calculated Stretch Coefficient 1.10 ft/Kft/Klb +-2%
∗ The armor wires are Galvanized Improved Plow Steel (GIPS) with anticorrosion compound for protection during
shipping and storing.
∗ SUPERSEAL, a special pressure seal agent could be applied between armor layers.
∗ Recommended maximum working load at 50 % of total cable breaking strength.
Rev: 02 23–July– 10
CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 777471 Phone (281) 342-4494 Facsimile (281) 342-0531