0% found this document useful (0 votes)
528 views

Guide For 150B1 01074848 Parameter Modification Through Maintenance Tool

The document provides instructions for modifying parameters of a 150B1 lithium battery through a maintenance tool. It describes preparing a USB to RS485 serial cable, connecting the battery and laptop, running the tool software, and changing the equivalent cell number from 16 to 15.

Uploaded by

Ronmel Facundo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
528 views

Guide For 150B1 01074848 Parameter Modification Through Maintenance Tool

The document provides instructions for modifying parameters of a 150B1 lithium battery through a maintenance tool. It describes preparing a USB to RS485 serial cable, connecting the battery and laptop, running the tool software, and changing the equivalent cell number from 16 to 15.

Uploaded by

Ronmel Facundo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Guide for 150B1(01074848) Parameter

Modification through Maintenance Tool

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.


1. Preparing
1)Serial Cable(USB to RS485)
➢ Check the PO if the cable is included.

➢ If Not, need prepare it according to the guide in next page.

2) Laptop with Microsoft system.

3) Maintenance Tool which can be obtained from Support.


https://support.huawei.com/carrier/navi?coltype=software#col=software&detailI
d=PBI1-22782510&path=PBI1-7921455/PBI1-21439559/PBI1-21439583/PBI1-
21100577/PBI1-21522802

HUAWEI TECHNOLOGIES CO., LTD. 2


1. Preparing
Pls disconnect the communication
cable between li battery and SMU
USB to RS485 cable Preparation when connects to maintenance tool

LAN Cable
Connect to RS485-USB Adapter Connect to
computer Recommended: UT-890A Battery COM_IN Lithium Battery
or COM_OUT

Wire sequence of a straight-through


cable

UT-890A Driver document:

Usually the Windows will


automatically install the driver. If not,
pls manually install the driver based
on the Windows system type.

HUAWEI TECHNOLOGIES CO., LTD. 3


2. Modify the Equivalent Cells
1) Connect the laptop and li battery through serial cable, Pls disconnect the communication cable between li
battery and SMU when connects to maintenance tool

2) Run the tool

3) Select Serial Port


Check the port number:

Right click

HUAWEI TECHNOLOGIES CO., LTD. 4


Modify the Equivalent Cells
4) Change the Equivalent Cell to 15


Change the Equivalent Cell
Number 16 to 15, and Submit

HUAWEI TECHNOLOGIES CO., LTD. 5


3. Check the Alarm Parameters in SMU

01074848-007 ESM-48150B1 User Manual


https://support.huawei.com/carrier/docview!d
ocview?nid=DOC1100586892&topicId=9236c0
57

HUAWEI TECHNOLOGIES CO., LTD. 6

You might also like