Smart Task 02

This document is a simulation report from PVsyst for a 100 kWp grid-connected solar photovoltaic system located in Krishna Nagar, Delhi, India. The system consists of 304 solar modules in 16 strings of 19 modules each, with a total module area of 590 square meters. Annual system production is estimated to be 142,967 kWh with a specific yield of 1,425 kWh/kWp and performance ratio of 82.69%.

Uploaded by

Rachit Gupta
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

Smart Task 02

This document is a simulation report from PVsyst for a 100 kWp grid-connected solar photovoltaic system located in Krishna Nagar, Delhi, India. The system consists of 304 solar modules in 16 strings of 19 modules each, with a total module area of 590 square meters. Annual system production is estimated to be 142,967 kWh with a specific yield of 1,425 kWh/kWp and performance ratio of 82.69%.

Uploaded by

Rachit Gupta
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Version 7.3.

PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System

Project: VCE_Task2
Variant: New simulation variant
No 3D scene defined, no shadings
System power: 100 kWp

PVsyst TRIAL
Krishna Nagar, Delhi - India

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: VCE_Task2
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23

PVsyst TRIAL
with v7.3.4

Project summary
Geographical Site Situation Project settings
Krishna Nagar, Delhi Latitude 28.66 °N Albedo 0.20
India Longitude 77.29 °E
Altitude 184 m
Time zone UTC+5.5

Meteo data
Krishna Nagar, Delhi
Meteonorm 8.1 (1996-2015), Sat=100% - Synthetic

System summary

PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 30 / 0 °

System information
PV Array Inverters
Nb. of modules 304 units Nb. of units 0.8 unit
Pnom total 100 kWp Pnom total 83.3 kWac
Pnom ratio 1.204

Results summary
Produced Energy 142967 kWh/year Specific production 1425 kWh/kWp/year Perf. Ratio PR 82.69 %

PVsyst TRIAL
Project and results summary

Main results
Loss diagram
Predef. graphs
Table of contents

General parameters, PV Array Characteristics, System losses


2
3
4
5
6

PVsyst TRIAL

PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 2/6
Project: VCE_Task2
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23

PVsyst TRIAL
with v7.3.4

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model TSM-330DD14A(II) Model PVS-100-TL
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 330 Wp Unit Nom. Power 100 kWac
Number of PV modules 304 units Number of inverters 5 * MPPT 17% 0.8 unit
Nominal (STC) 100 kWp Total power 83.3 kWac
Modules 16 Strings x 19 In series Operating voltage 360-1000 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.20
Pmpp 90.5 kWp No power sharing between MPPTs
U mpp 642 V
I mpp 141 A

PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 100 kWp Total power 83 kWac
Total 304 modules Nb. of inverters 1 unit
Module area 590 m² 0.2 unused
Cell area 530 m² Pnom ratio 1.20

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 76 mΩ Loss Fraction -0.4 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss IAM loss factor


Loss Fraction 2.0 % at MPP Loss Fraction 0.2 % ASHRAE Param.: IAM = 1 - bo (1/cosi -1)
bo Param. 0.05

PVsyst TRIAL

PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 3/6
Project: VCE_Task2
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23

PVsyst TRIAL
with v7.3.4

Main results
System Production
Produced Energy 142967 kWh/year Specific production 1425 kWh/kWp/year
Perf. Ratio PR 82.69 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 85.9 47.3 13.20 113.3 110.8 10189 9989 0.879

PVsyst TRIAL
February 109.2 56.8 17.39 135.0 132.1 11821 11594 0.856
March 156.2 73.2 23.50 175.8 171.9 14795 14514 0.823
April 173.0 82.8 29.58 175.3 171.0 14321 14036 0.798
May 183.6 103.1 33.48 172.0 167.2 13978 13711 0.795
June 171.0 102.6 33.08 154.8 150.2 12747 12509 0.805
July 148.6 93.0 31.38 135.8 131.7 11317 11100 0.815
August 144.2 96.2 30.40 139.2 135.3 11706 11482 0.822
September 140.7 77.3 29.05 150.1 146.3 12518 12276 0.815
October 123.9 72.0 26.25 143.6 140.5 12119 11886 0.825
November 92.3 55.1 19.97 116.8 114.2 10217 10027 0.856
December 84.1 49.8 14.82 111.9 109.4 10041 9846 0.877
Year 1612.8 909.2 25.21 1723.5 1680.7 145769 142967 0.827

PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 4/6
Project: VCE_Task2
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23

PVsyst TRIAL
with v7.3.4

Loss diagram
1613 kWh/m² Global horizontal irradiation
+6.9% Global incident in coll. plane

-2.49% IAM factor on global

1681 kWh/m² * 590 m² coll. Effective irradiation on collectors

efficiency at STC = 17.01% PV conversion

168630 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.21% PV loss due to irradiance level

-10.66% PV loss due to temperature

+0.35% Module quality loss

-2.15% Mismatch loss, modules and strings

-0.99% Ohmic wiring loss


146153 kWh Array virtual energy at MPP
-1.91% Inverter Loss during operation (efficiency)
-0.27% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage

PVsyst TRIAL
-0.01% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
142967 kWh Available Energy at Inverter Output
142967 kWh Energy injected into grid

PVsyst TRIAL

PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 5/6
Project: VCE_Task2
Variant: New simulation variant

PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23

PVsyst TRIAL
with v7.3.4

Predef. graphs
Daily Input/Output diagram

PVsyst TRIAL

PVsyst TRIAL System Output Power Distribution

PVsyst TRIAL

PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 6/6

You might also like