Smart Task 02
Smart Task 02
PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System
Project: VCE_Task2
Variant: New simulation variant
No 3D scene defined, no shadings
System power: 100 kWp
PVsyst TRIAL
Krishna Nagar, Delhi - India
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: VCE_Task2
Variant: New simulation variant
PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23
PVsyst TRIAL
with v7.3.4
Project summary
Geographical Site Situation Project settings
Krishna Nagar, Delhi Latitude 28.66 °N Albedo 0.20
India Longitude 77.29 °E
Altitude 184 m
Time zone UTC+5.5
Meteo data
Krishna Nagar, Delhi
Meteonorm 8.1 (1996-2015), Sat=100% - Synthetic
System summary
PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 304 units Nb. of units 0.8 unit
Pnom total 100 kWp Pnom total 83.3 kWac
Pnom ratio 1.204
Results summary
Produced Energy 142967 kWh/year Specific production 1425 kWh/kWp/year Perf. Ratio PR 82.69 %
PVsyst TRIAL
Project and results summary
Main results
Loss diagram
Predef. graphs
Table of contents
PVsyst TRIAL
PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 2/6
Project: VCE_Task2
Variant: New simulation variant
PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23
PVsyst TRIAL
with v7.3.4
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model TSM-330DD14A(II) Model PVS-100-TL
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 330 Wp Unit Nom. Power 100 kWac
Number of PV modules 304 units Number of inverters 5 * MPPT 17% 0.8 unit
Nominal (STC) 100 kWp Total power 83.3 kWac
Modules 16 Strings x 19 In series Operating voltage 360-1000 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.20
Pmpp 90.5 kWp No power sharing between MPPTs
U mpp 642 V
I mpp 141 A
PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 100 kWp Total power 83 kWac
Total 304 modules Nb. of inverters 1 unit
Module area 590 m² 0.2 unused
Cell area 530 m² Pnom ratio 1.20
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 76 mΩ Loss Fraction -0.4 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 3/6
Project: VCE_Task2
Variant: New simulation variant
PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23
PVsyst TRIAL
with v7.3.4
Main results
System Production
Produced Energy 142967 kWh/year Specific production 1425 kWh/kWp/year
Perf. Ratio PR 82.69 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
February 109.2 56.8 17.39 135.0 132.1 11821 11594 0.856
March 156.2 73.2 23.50 175.8 171.9 14795 14514 0.823
April 173.0 82.8 29.58 175.3 171.0 14321 14036 0.798
May 183.6 103.1 33.48 172.0 167.2 13978 13711 0.795
June 171.0 102.6 33.08 154.8 150.2 12747 12509 0.805
July 148.6 93.0 31.38 135.8 131.7 11317 11100 0.815
August 144.2 96.2 30.40 139.2 135.3 11706 11482 0.822
September 140.7 77.3 29.05 150.1 146.3 12518 12276 0.815
October 123.9 72.0 26.25 143.6 140.5 12119 11886 0.825
November 92.3 55.1 19.97 116.8 114.2 10217 10027 0.856
December 84.1 49.8 14.82 111.9 109.4 10041 9846 0.877
Year 1612.8 909.2 25.21 1723.5 1680.7 145769 142967 0.827
PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 4/6
Project: VCE_Task2
Variant: New simulation variant
PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23
PVsyst TRIAL
with v7.3.4
Loss diagram
1613 kWh/m² Global horizontal irradiation
+6.9% Global incident in coll. plane
PVsyst TRIAL
-0.21% PV loss due to irradiance level
PVsyst TRIAL
-0.01% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
142967 kWh Available Energy at Inverter Output
142967 kWh Energy injected into grid
PVsyst TRIAL
PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 5/6
Project: VCE_Task2
Variant: New simulation variant
PVsyst V7.3.4
VC0, Simulation date:
15/06/23 12:23
PVsyst TRIAL
with v7.3.4
Predef. graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
15/06/23 PVsyst Evaluation mode Page 6/6