0% found this document useful (0 votes)
102 views

Combined Footing Type4

The document summarizes the design of a combined footing supporting two columns. Key details include: - The footing is 4.4m long, 1.8m wide, and 0.7m thick, supporting Column 1 with a load of 571kN and Column 2 with a load of 1406kN. - Soil pressure, moment, and shear calculations are presented. The actual soil pressure and stresses are less than the allowable values, indicating the design is safe. - Reinforcement requirements are calculated as 3439mm^2 of #20 bars along the long direction and 2153mm^2 of #20 bars along the short direction.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views

Combined Footing Type4

The document summarizes the design of a combined footing supporting two columns. Key details include: - The footing is 4.4m long, 1.8m wide, and 0.7m thick, supporting Column 1 with a load of 571kN and Column 2 with a load of 1406kN. - Soil pressure, moment, and shear calculations are presented. The actual soil pressure and stresses are less than the allowable values, indicating the design is safe. - Reinforcement requirements are calculated as 3439mm^2 of #20 bars along the long direction and 2153mm^2 of #20 bars along the short direction.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

DESIGN of COMBINED FOOTING (Axially Loaded) Date: 9/19/2023 10:36

Project: CAMP JOHN HAY MANOR 2E Mark: CF-1


INPUT
MATERIALS:

Concrete: f'c = 20.7 MPa


Steel: fy = 414 MPa
Concrete Unit Weight: = 23.56 kN/m3
Concrete Cover : = 75 mm
Soil Unit Weight. : = 16 kN/m3
Soil Brg. Cap : = 478 kPa
Main Bar: = 20 mm ø
Temp. Bar : = 16 mm ø

FOOTING LOADS:
=
Col 1 : PDL = 317.4 Kn
PLL = 74.57 Kn
Pu = 571 Kn
Col 2 : PDL = 684.84 Kn
PLL = 263.19 Kn
Pu = 1406 Kn
DIMENSIONS:
= 1406.199
thickness T = 0.7 m
length L = 4.4 m
width B = 1.8 m
depth H = 1.2 m
column 1 col thk t = 0.3 m
col width b = 0.5 m
column 2 col thk t = 0.3 m
col width b = 0.5 m
X1 = 0.01 m
X2 = 2.68 mm2
X3 = 1.13 mm2
A required = 2.95
A provided = 7.92

SCHEMATIC DIAGRAMS :

N.G.L.

note: proper computations must be done for x1 to x3


in order that the load resultant coincides w/ the

center of gravit of the footing.

If x1 or x3 is zero, input must be 0.01.

col col
1 2
1/3
2/3
OUTPUT: Pu Pu
SOIL PRESSURES:
qnet = 453.886 kPa
qult = 249.66 kPa
Wushort = 781.22 kN/m
Wulong = 449.39 kN/m Wu
Eff. Depth, dL = 565.00 mm
Eff. Depth, dS = 555.00 mm
Eff. Width, = 1147.50 mm

MOMENTS:
Along long direction:
@center of col. 1 : = 0.03 kN-m
between columns: = -271.54 kN-m
@center of col. 2 : = 458.66 kN-m
Along short direction:
@ face of column: = 165.03 kN-m

SHEARS:
Along long direction:
@ left Face of col1 = 4.49 kN
@ right Face of col1 = -431.82 kN
@ left Face of col2 = 770.31 kN
@ right Face of col2 = -501.07 kN

ACTUAL STRESSES vs. ALLOWABLE :


V punching actual = 0.63 MPa
Vpunching allowable = 1.52 MPa safe against punching shear!
V beam actual = 0.60 MPa
Vbeam allowable = 0.76 MPa safe against beam shear!
=
Actual Soil Pressure: Ptotal / Areaactual
actual ftg.wt. = 188.34 kN
Ptotal = ftg.wt.+ Paxial
Total Weight Ptotal = 1528.3 kN
Actual Soil Pressure qactual = 192.97 kPa
All. Soil Pressure qallow = 478.00 kPa
Actual soil pressure is less than allowable; Safe!

ADOPT: 1.8 X 4.4 X 0.7 combined footing


B X L X T

REINFORCEMENTS:
Along Long Direction:
As1 = 3439.1304 mm2 Provide 11 pcs -- 20 mm-ø bottom bars @ columns
As2 = 3439.1304 mm2 Provide 11 pcs -- 20 mm-ø top bars b/n columns.
Temperature Bars: Provide 16 mm ø @ 150 mm on center
Along Short Direction:
As3 = 2153.6413 mm2 Provide 7 pcs -- 20 mm-ø bottom bars within Be
Temperature Bars: Provide 16 mm ø @ 150 mm on center