Aoc 20i Aoc 20s Shimadzu
Aoc 20i Aoc 20s Shimadzu
AOC-20i / AOC-20s
Design goals set and surpassed in AOC-20 Series
...Ideal sample handling with high throughput, data reliability and traceability.
Auto Injector
AOC-20i
Sample introduction is a key aspect of any gas chromatographic system.
The auto injector must be able to inject samples into a variety of injection ports,
including split/splitless, direct (WBI), cool on column (OCI) or programmed
temperature vaporization (PTV).
Injection parameters also must be controlled to best suit your sample analysis.
The new AOC-20 (Automatic Operation Controller) does all of this and more,
providing the ideal solution for your laboratory challenges.
The AOC-20 provides the highest degree of reliability. This means that the unit
produces reproducible results, with a minimum of problems such as bent needles,
evaporating samples, etc. Maintaining reproducible results requires that periodic
maintenance be performed, such as changing the injection port septa or syringe.
With the AOC-20, these procedures are simple and you can comfortably perform
them without fear of adversely affecting instrument performance.
The challenge in today's laboratory is processing large sample numbers and various
vial types in an automated fashion. In addition, ever decreasing detection limits
demand increased flexibility for different injection techniques, including large
volume injection (LVI), solvent flush, and solvent flush with a second solvent.
The AOC-20 meets these challenges and enhances throughput to meet your
productivity goals.
Auto Sampler
AOC-20s
Flexible sample handling of up to 150 vials, greatly enhances laboratory
productivity!
The AOC-20s Auto Sampler carousel and robotic arm provide for sample transport
to the AOC-20i Auto Injector using 1.5 mL and 4.0 mL vials. The system is smart too!
It can tell the difference between the vial types by reading the information from
the vial tray in use. The AOC-20i/AOC-20s is a powerful automation tool for the GC
laboratory that allows the user to take full advantage of the GC system's
capabilities.
AOC-20i configured with the GC-2014
4
Ideal Sample Handling means that the sample LabSolutions s oftware for fur t h er
is injected the way you want it to be! c onvenienc e!
Injection mode choices include traditional, solvent flush,
solvent flush with a second solvent and large volume
injection.
These choices provide solutions to various analytical
challenges and problems. The traditional mode is used for
most applications.
However, the solvent flush mode is effective in reducing the
effects of boiling point discrimination, while the solvent flush
with a second solvent mode allows for the addition of an
internal standard for quantitative calculations or retention
index. Large volume injection mode is effective in analyzing
trace components.
In solvent flush mode, after drawing the sample into the syringe, air
may be drawn into the needle tip to prevent evaporation of the
sample from the needle.
AIR
Sample Solvent E a sy O p e ra ti o n
LabSolutions offers both ease of operation and extensive
Solvent flush with a second solvent mode allows for the addition of an functionality by utilizing a common operating environment
internal standard or a second solvent perhaps more conducive to the shared throughout the LabSolutions series, including such
"solvent effect" in splitless injection. features as an Assistant Bar and Data Explorer, to provide a
user interface that can be operated intuitively and learned in
AIR a short time.
H i g h P ro d u cti v i ty
In a dual injection system, it permits chromatographic
Sample
Internal
Solvent
analysis of eight flowpaths simultaneously.
Standard
G L P /G MP C o mp l i a n t
Large volume injection mode supports PTV trace analysis User management, audit trail, validation support, and
Plunger speeds can be varied from fast, medium, to slow. precision management support functions achieve
Optional 50µL and 250µL syringes are also supported as is the comprehensive GLP/GMP compliance.
multiple re-injection mode which allows volumes larger than
the maximum syringe volumes to be injected. F l e x i b l e R e p o rt F u n cti o n s
The Hyper-report functions offer a flexible report format,
similar to Microsoft Word. These functions permit simple and
efficient report generation and maintenance of analysis data.
Summary report output is possible.
AOC-20i /AOC-20s
Auto Injector/Auto Sampler 5
Variab
6
50µL
Depth
250µL
78mm
Optional large volume syringe for large volume injection (LVI) with PTV.
Width 126mm
Variable plunger speed at injection facilitates standard and
LVI techniques.
ble syringe injection speed allows for optimization based upon injection port mode.
Diameter 320mm
8
Ideally designed for productivity and intelligent too!
9
Specifications
AOC-20i AOC-20s
Sample injection method Liquid sample injection via special microsyringe
Sample volume 0.1~8.0µL, 0.1µL steps (using 10µL syringe)
Number of samples 6 vials (with option, 12 possible) 1.5mL sample vials 150 vials
4mL sample vials 96 vials
Sample vials Glass construction, 1.5mL, 4mL, screw top, Teflon-coated septum
Rinse solvent vial Glass construction, 4mL, screw top, Teflon-coated septum
Type of sample injection 3 Modes: Traditional, Solvent Flush and Solvent Flush with a Second Solvent
Cross contamination Less than 10-4 (as determined with a 1% diphenyl in hexane using 4 solvent rinses)
Priority sample A priority sample injection can be injected during a sample sequence, then the sequence can be resumed.
Dual injection system Available on GC-2010 platform One set of AOC-20s can feed sample vials
to two sets of AOC-20i
Double your productivity with the dual tower AOC-20 (GC-2010/2010 Plus only)
The AOC-20 series includes a dual tower auto injector option which
doubles the productivity of a single dual injector, dual detector gas
chromatograph.
It may be operated in seven different modes from the keyboard or
random access from GCsolution. The AOC-20s provides sample transport.
The highest productivity is then assured for applications such as simple
high sample throughput on identical GC analysis channels or for dual
column confirmation. In either case, the AOC-20 dual tower
configuration is a powerful tool for laboratory productivity.
10
Instrument, Accessory, Supplies
A OC-2 0 S er ie s M ai n Bodi es
AOC-20s Auto Sampler 221-72300-31 Includes: sample carousel and 6 1.5mL sample vial racks
AOC-20i /AOC-20s
Auto Injector/Auto Sampler 11
AOC-20i / AOC-20s
G a s C h ro m a to g ra p h s
Wo rk s ta ti on , D a ta P ro ce sso r
Chromatopac C-R8A
This compact instrument incorporates all the
functions required for chromatography.
The numerous peak processing functions
and quantitative calculations are included.
The hardware validation software (accessed
with the VP key) supports GLP/GMP and ISO
requirements.
The C-R8A includes a high speed RS-232C
port (19,200 bps) as standard for
networking.
Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its
affiliates, whether or not they are used with trademark symbol “TM” or “®”.
Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu
disclaims any proprietary interest in trademarks and trade names other than its own.