0% found this document useful (0 votes)
46 views

Axeon 7 JT-series Linked

Safe drinking water is important for everyone. Impurities such as minerals, dissolved solids, heavy metals or nitrates in water can cause an unusual taste or odor, and contaminants can affect otherwise healthy people. To combat poor water quality, AXEON (in partnership with National Testing Laboratories) offers water quality testing.

Uploaded by

Joanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views

Axeon 7 JT-series Linked

Safe drinking water is important for everyone. Impurities such as minerals, dissolved solids, heavy metals or nitrates in water can cause an unusual taste or odor, and contaminants can affect otherwise healthy people. To combat poor water quality, AXEON (in partnership with National Testing Laboratories) offers water quality testing.

Uploaded by

Joanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PRODUCT SPECIFICATIONS

JT– SERIES WALL MOUNT REVERSE


OSMOSIS SYSTEMS
AXEON® JT– Series Wall Mount Reverse Osmosis
Systems offer high production capacities and are fully
equipped with a computer controller, TDS monitor,
multi-stage booster pump, low energy membranes

resistant, powder-coated aluminum frame.

AXEON JT– Series Wall Mount Reverse Osmosis


Systems models are available in capacities of 2,000
and 4,000 gallons per day and feature the EZMount™
two-piece wall mounting system for easy installation.
An optional mobile stand is also available to convert
JT– 4000 Wall Mount
Reverse Osmosis System

FEATURES OPTIONS
• Minitrol Computer Controller • S –150 Computer Controller with
• Multi Color LED Indicator Status Light Feed Flush and Dual TDS
• Pre-Treatment Lockout • S –150 Computer Controller
• Tank Level Input Expander Board
• Low Pressure Monitoring and Alarm • AXEON HF4 – Series Extra Low Energy
Membrane Elements
• AXEON HF1– Series Low Energy Membranes
• AXEON HF5 – Series Ultra Low Energy
• AXEON 5-Micron Sediment Pre-Filter
Membrane Elements
• SS – Series Membrane Housings
• FRP– Series Membrane Housings
• Pentair® Big Grey Cartridge Housing
• Goulds® Multi-Stage Stainless Steel
• Goulds® Multi-Stage Booster Pump Booster Pump
• Concentrate Pressure Gauge • Concentrate Recycle Valve with
• Feed Low Pressure Switch Flow Meter
• GC® Feed Solenoid Valve • High Pressure Tank Switch
• Low Pressure Monitoring and Alarm • Chemical Pump Outlet
• 316L Stainless Steel Concentrate Valve • Optional Mobile Stand
• Permeate and Concentrate Flow Meters
• Pre-Filter Pressure Gauge 0-100 psi
• Post-Filter Pressure Gauge 0-100 psi
• Pump Pressure Gauge 0-300 psi
• John Guest® Push/Pull Fittings with Locking Safety Clips
• White Powder Coated Aluminum Frame
SPECIFICATIONS
MODELS JT– 2000 JT– 4000
Design
Single Pass Single Pass
Feedwater Source (ppm)A TDS < 2000 TDS < 2000
Standard Recovery Rate % 31 64
Flow RatesB
Permeate Flow (gpm / lpm) 1.38 / 5.22 2.78 / 10.52
Minimum Feed Flow (gpm / lpm) 4.38 / 16.60 5.78 / 21
Minimum Concentrate Flow (gpm / lpm) 3 / 11.36 3 / 11.36
Connections
Feed (in) 1 FNPT 1 FNPT
Permeate (in) 1/2 QC 1/2 QC
Concentrate (in) 1/2 QC 1/2 QC
Membranes
Membranes Per Vessel 1 1
Membrane Quantity 1 2
Membrane Size 4040 4040
Nominal Salt Rejection % 99 99
Vessels
Vessel Array 1 1:1
Vessel Quantity 1 2
Pumps
Pump Type Multi-Stage Multi-Stage
Motor HP 1.5 1.5
RPM at 60Hz / 50Hz 3450 / 2900 3450 / 2900
System Electrical
Standard Voltage + Amp Draw C 220V, 60Hz, 1PH, 8.3A 220V, 60Hz, 1PH, 8.3A
220V, 50Hz, 1PH, 8.9AC 220V, 50Hz, 1PH, 8.9AC
220V, 60Hz, 3PH, 5.1AC 220V, 60Hz, 3PH, 5.1AC
High Voltage Service + Amp Draw C 220V, 50Hz, 3PH, 6.1AC 220V, 50Hz, 3PH, 6.1AC
380V, 50Hz, 3PH, 4.5AC 380V, 50Hz, 3PH, 4.5AC
460V, 60Hz, 3PH, 3.5AC 460V, 60Hz, 3PH, 3.5AC
System Dimensions
12 x 48 x 49 / 12 x 48 x 49 /
Approximate Dimensions D L x W x H (in / cm)
30.50 x 122 x 124.50 30.50 x 122 x 124.50
Approximate Weight (lbs / kg) 150 / 68 175 / 79.40

Test Parameters: 550 TDS Filtered (5-Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 150 psi / 10.35 bar Operating Pressure, 77°F / 25°C, Recovery as stated, 7.0 pH.
Data taken after 60 minutes of operation.
A.
applications which do not meet or exceed minimum and maximum operating limits for such conditions.
B.
C. Varies with motor manufacturer.
D. Does not include operating space requirements.

OPERATING LIMITS E
Maximum Feed Temperature (°F / °C) 85 / 29 Maximum Turbidity (NTU) 1

Minimum Feed Temperature (°F / °C) 40 / 4 Maximum Free Chlorine (ppm) 0

Maximum Ambient Temperature (°F / °C) 120 / 49 Maximum TDS (ppm) 2,000

Minimum Ambient Temperature (°F / °C) 40 / 4 Maximum Hardness (gpm) 0

Maximum Feed Pressure (psi / bar) 85 / 6 Maximum pH (continuous) 11

Minimum Feed Pressure (psi / bar) 45 / 3 Minimum pH (continuous) 2

Maximum Operating Pressure (psi / bar) 150 / 10 Maximum pH (cleaning 30 minutes) 13

Maximum SDI Rating <3 Minimum pH (cleaning 30 minutes) 1

E. If any of the feed water parameters are not within the limits given, consult your local dealer or distributer for assistance.