Go to Windows "Start" > "All Programs" > "Keyspan USB Serial Adapter" > "Keyspan Serial
Assistant" to access the following window that will default to the "Adapter Status" tab indicating
which communications port the adapter is mapped to. The example below indicates that "COM4" is
selected and the MD22 spectrophotometer should have no problem communicating with the PREVU*
and Cholesterol 1,2,3 software providing that "COM4" is selected in that software's "Options"
window.
✉ Contact Call
https://www.xrite.com/service-support/com_port_mapping_with_keyspan_usb_serial_adapter 1/6
8/15/23, 10:35 PM COM Port Mapping with Keyspan USB Serial Adapter
The "Properties" tab states the current configuration and allows the user to test it by clicking on the
"Test This Port". "PASSED" or "FAILED" will appear in the "Serial Test Status" box.
✉
https://www.xrite.com/service-support/com_port_mapping_with_keyspan_usb_serial_adapter 2/6
8/15/23, 10:35 PM COM Port Mapping with Keyspan USB Serial Adapter
The "Port Mapping" tab allows you to configure a different communications port for the "Keyspan
USB Serial Adapter". It would be advisable to select "Show All COM Assignments" before
considering a making any changes. In the example below "COM2" is not in use and will be
selected. Having the mode selected as "Dynamic" will allow the user to successfully connect to each
of the PC's USB ports.
✉
https://www.xrite.com/service-support/com_port_mapping_with_keyspan_usb_serial_adapter 3/6
8/15/23, 10:35 PM COM Port Mapping with Keyspan USB Serial Adapter
After selecting another COM port ("COM2" in this example), confirmation window will appear.
Make sure that you are selecting the proper COM port (in this example: "COM2") and then select
"Yes" to continue.
A second confirmation window will indicate a successful remapping of the port. Select "OK".
✉
https://www.xrite.com/service-support/com_port_mapping_with_keyspan_usb_serial_adapter 4/6
8/15/23, 10:35 PM COM Port Mapping with Keyspan USB Serial Adapter
More detailed information on the "Keyspan USB Serial Adapter Assistant" can be accessed by
selecting the "Help" tab and then selecting the "User's Manual" as shown below:
If the customer is using PREVU* software, the spectrophotometer will automatically select the proper
COM port as long as it is "COM1", "COM2", "COM3", or "COM4". If the customer is using
Cholesterol 1,2,3 software and they still receive the following error while trying to open the software:
✉
https://www.xrite.com/service-support/com_port_mapping_with_keyspan_usb_serial_adapter 5/6
8/15/23, 10:35 PM COM Port Mapping with Keyspan USB Serial Adapter
Select "OK" to the "Error" window and the Cholesterol 1,2,3 home screen will appear. Click on the
"Options" icon as circled in red below:
In the resulting window, select the proper COM port ("COM2" in this example)and then select
"OK".
Close out of the software and then reopen it to test. No communications error should appear if
properly configured.
✉