N2XBY
N2XBY
Construction Data
Application :
Nom. Overall Cable Copper Conductor
For installation indoors, cable channels and in
Cross Diameter Weight ground, for industry installations, switchgear,
Section XLPE Insulation
and power station, if there is a risk that low
Area approx. approx. mechanical damage may occur. PVC Inner Sheath
mm² mm kg/km
Special Features on Request Aluminium Tape Armor
16 16.0 419 • Fire Resistance
25 16.2 488 • Oil Resistance
PVC Sheath
• UV Resistance
35 17.3 597 • Flame Retardant Cat. A, B, C
50 19.1 764 • Flame Retardant Non Category
• Anti Termite
70 21.5 994
• Anti Rodent
95 23.0 1,256 • Low Smoke Zero Halogen
120 25.0 1,516
150 27.0 1,804
185 29.0 2,221 Note :
Conductor Shape
240 32.0 2,829
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
300 35.0 3,409 25 - 500 sqmm supplied in non compacted circular stranded (rm) or compacted
400 39.0 4,326 circular stranded (cm) conductor shape
Electrical Data
Conductor Inductance Current - Carrying Capacity at 30° C * Short
circuit current
Nom. DC AC Trefoil Flat
at
Cross Resistance Resistance formation formation in air in ground in air in ground 1 sec
Sect. at 20°C at 90°C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XBY
N2XBY 22xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Steel Tape Armor, PVC Sheathed)
Standard Specification : SPLN 43-8
Construction Data
Application :
Nom. Overall Cable Copper Conductor
For installation indoors, cable channels and in
Cross Diameter Weight ground, for industry installations, switchgear, XLPE Insulation
Section and power station, if there is a risk that low
Area approx. approx. mechanical damage may occur. PVC Inner Sheath
mm² mm kg/km
Special Features on Request
Steel Tape Armor
1.5 15.0 328 • Fire Resistance
2.5 15.0 341 • Oil Resistance
• UV Resistance
4 15.0 361 PVC Sheath
• Flame Retardant Cat. A, B, C
6 16.1 431 • Flame Retardant Non Category
• Anti Termite
10 18.0 574 • Anti Rodent
16 20.5 753 • Low Smoke Zero Halogen
25 23.5 1,047
35 25.5 1,323
Note :
50 28.5 1,580 Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
70 32.5 2,140
conductor shape
95 36.5 2,810 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
120 41.5 3,824
150 45.5 4,606 Standard Packing
1.5 - 120 sqmm supplied in wooden drum @ 1000 m
185 50.5 5,663
150 - 300 sqmm will be suplied in wooden drum on available length
240 56.0 7,102 Length Tolerance per drum ± 2%
300 61.5 8,675
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XBY
N2XBY 33xx(1.5-300)
(1.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Steel Tape Armor, PVC Sheathed)
Standard Specification : SPLN 43-8
Construction Data
Application :
Nom. Overall Cable Copper Conductor
For installation indoors, cable channels and in
Cross Diameter Weight ground, for industry installations, switchgear, XLPE Insulation
Section and power station, if there is a risk that low
Area approx. approx. mechanical damage may occur.
PVC Inner Sheath
mm² mm kg/km
Special Features on Request Steel Tape Armor
1.5 15.0 334 • Fire Resistance
2.5 15.0 353 • Oil Resistance
• UV Resistance PVC Sheath
4 15.6 408 • Flame Retardant Cat. A, B, C
6 16.8 498 • Flame Retardant Non Category
• Anti Termite
10 18.9 679
• Anti Rodent
16 21.5 908 • Low Smoke Zero Halogen
25 24.5 1,283
35 27.0 1,643
50 29.0 1,870 Note :
Conductor Shape
70 33.5 2,596
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
95 38.0 3,747 conductor shape
120 41.5 4,548 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
150 46.0 5,542 50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
185 51.0 6,781
Standard Packing
240 56.5 8,634
1.5 - 95 sqmm supplied in wooden drum @ 1000 m
300 61.5 10,506 120 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XBY
N2XBY 44xx(2.5-300)
(2.5-300) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Steel Tape Armor, PVC Sheathed)
Standard Specification : SPLN 43-8
Construction Data
Application : Copper Conductor
Nom. Overall Cable
For installation indoors, cable channels and in
Cross Diameter Weight ground, for industry installations, switchgear, and
Section XLPE Insulation
power station, if there is a risk that low mechanical
Area approx. approx. damage may occur.
PVC Inner Sheath
mm² mm kg/km
Special Features on Request :
Steel Tape Armor
2.5 15.3 376 • Fire Resistance
4 16.6 473 • Oil Resistance
• UV Resistance PVC Sheath
6 18.0 584 • Flame Retardant Cat. A, B, C
10 20.5 816 • Flame Retardant Non Category
• Anti Termite
16 23.0 1,106 • Anti Rodent
25 26.5 1,580 • Low Smoke Zero Halogen
35 29.5 2,040
50 33.0 2,416
Note :
70 38.0 3,349 Conductor Shape
2.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
95 43.0 4,828
conductor shape
120 48.0 5,920 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape
150 54.0 7,238
50 - 300 sqmm supplied in sector shaped stranded (sm) conductor
185 58.0 8,769
Standard Packing
240 64.5 11,225
2.5 - 70 sqmm supplied in wooden drum @ 1000 m
300 70.5 13,682 95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XBY
N2XBY 55xx(4-50)
(4-50) mm²
mm² 0.6/1
0.6/1 kV kV
Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Steel Tape Armor, PVC Sheathed)
Standard Specification : SPLN 43-8
Construction Data
Application : PVC Filler
Nom. Overall Cable
For installation indoors, cable channels and in
Cross Diameter Weight Copper Conductor
ground, for industry installations, switchgear,
Section and power station, if there is a risk that low XLPE Insulation
Area approx. approx. mechanical damage may occur.
PVC Inner Sheath
mm² mm kg/km
Special Features on Request Steel Tape Armor
4 17.8 552 • Fire Resistance
• Oil Resistance
6 19.3 689 • UV Resistance PVC Sheath
10 22.0 966 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
16 25.0 1,320 • Anti Termite
• Anti Rodent
25 29.0 1,902 • Low Smoke Zero Halogen
35 32.5 2,482 • Nylon Coated
50 38.0 3,486
Note :
Conductor Shape
4 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 50 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
4 - 50 sqmm supplied in wooden drum @ 1000 m
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Short
Capacity circuit current
Nom. DC AC
at 30°C * at
Cross Resistance Resistance 1 sec
Sect. at 20°C at 90°C in air in ground
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification