Test Report 3494964
Test Report 3494964
TEST REPORT
For
Henry Ding
EMC Leader
Reviewed By:
Note: This test report was prepared for the customer shown above and for the device described herein. It may not be
duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Chengdu).
Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and
offenders may be prosecuted to the fullest extent of the law. This report was valid only with a valid digital
signature.
Bay Area Compliance Laboratories Corp. (Chengdu)
TABLE OF CONTENTS
GENERAL INFORMATION
The Quanzhou Wouxun Electronics Co., Ltd.’s product, model number: KG-UV9D (FCC ID:
WVTWOUXUN12) (the "EUT") in this report was a Two-Way Radio, which was measured
approximately: 6.15 cm (L) x 3.39 cm (W) x 12.5 cm (H), rated input voltage: DC7.4V from Li-ion
battery or DC 12V from adapter.
Adapter Information:
Model: CA-001
Input:AC 100-240V 50/60Hz 0.3A
Output:DC12V 500Ma
Note: The series product, models KG-UV9D, KG-UV8D, KG-UV8D(Plus), KG-UV7D, KG-UV9D(Plus),
KG-UV83, KG-UV86, KG-UV66, KG-UV899, KG-UV8A, KG-UV8E, KG-UV8F, KG-UV8G, KG-UV8H,
KG-UV8T are electrically identical, we selected KG-UV9D for fully testing, and the details of the differences
between them were explained in the attached declaration letter.
*All measurement and test data in this report was gathered from final production sample, serial number:
170418050 (assigned by the BACL, Chengdu). It may have deviation from any other sample. The EUT
supplied by the applicant was received on 2017-04-18, and EUT conformed to test requirement.
Objective
This test report is prepared on behalf of Quanzhou Wouxun Electronics Co., Ltd. in accordance
with Part 2, Subpart J, and Part 15-Subparts A and B of the Federal Communications
Commission’s rules.
The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class
B.
Related Submittal(s)/Grant(s)
NO Related Submittal(s)/Grant(s)
Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2014, American
National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage
Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz.
The Bay Area Compliance Laboratories Corp. Chengdu’s measurement Uncertainties (calculated
for a k=2 Coverage Factor corresponding to approximately 95% Coverage) were as follows:
-For all of the AC Line Conducted Emissions Tests reported herein: ±3.17 dB.
-For of all of the direct Radiated Emissions Tests reported herein are:
30 MHz to 200 MHz: ±4.7 dB;
200 MHz to 1 GHz: ±6.0 dB;
1 GHz to 6 GHz: ±5.13dB; and,
6 GHz to 40 GHz: ±5.47dB.
And the uncertainty will not be taken into consideration for all test data recorded in the report.
Test Facility
The test site used by BACL to collect test data is located in the 5040, HuiLongWan Plaza, No. 1,
ShaWan Road, JinNiu District, ChengDu, China.
Test site at BACL has been fully described in reports submitted to the Federal Communication
Commission (FCC). The details of these reports have been found to be in compliance with the
requirements of Section 2.948 of the FCC Rules on April 24, 2015. The facility also complies with
the radiated and AC line conducted test site criteria set forth in ANSI C63.4-2014.
The Federal Communications Commission has the reports on file and is listed under FCC
Registration No.: 910975. The test site has been approved by the FCC for public use and is listed
in the FCC Public Access Link (PAL) database.
The system was configured for testing in a typical fashion (as normally used by a typical user).
Equipment Modifications
EUT Setup
The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The
specification used was with the FCC Part 15 B Class B limits.
The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in
the middle.
The Adapter was connected to the main LISN with a 120V/60Hz AC power source.
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.
During the conducted emission test, the EMI test receiver was set with the following configurations:
* Statement of Traceability: BACL(Chengdu) attests that all of the calibrations on the equipment items
listed above were traceable to NIM or to another internationally recognized National Metrology Institute
(NMI), and were compliant with the NIST HB 150-2016 Normative Annex B “Implementation of traceability
policy in accredited laboratories”.
Test Procedure
During the conducted emission test, the Adapter was connected to the outlet of the first LISN and
the other support equipments were connected to the outlet of the second LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.
All data was recorded in the Quasi-peak and average detection mode.
VC = VR + AC + VDF
Herein,
VC: corrected voltage amplitude
The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the maximum
limit. The equation for margin calculation is as follows:
Test Data
Environmental Conditions
Temperature: 26.2 C
Relative Humidity: 56 %
ATM Pressure: 99.7 kPa
80
70
Quasi-Peak Limit
60
Average Limit
50
Level in dBμ
40
30
20
10
0
150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Frequency in Hz
80
70
Quasi-Peak Limit
60
Average Limit
50
Level in dBμ
40
30
20
10
0
150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Frequency in Hz
EUT Setup
Below 1GHz:
Above 1GHz:
The radiated emission tests were performed at the 3 meters distance in chamber, using the setup
accordance with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B
limits.
During the radiated emission test, the EMI test receiver was set with the following configurations:
Test Procedure
During the radiated emissions, the Adapter was connected to the first AC floor outlet and the other
support equipments were connected to the second AC floor outlet.
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied
with all installation combinations.
The data was recorded in the Quasi-peak detection mode for below 1 GHz, peak and average
detection mode above 1 GHz.
The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and
subtracting the Amplifier Gain from the Meter Reading. The basic equation is as follows:
Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the
applicable limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The
equation for margin calculation
is as follows:
Test Data
Environmental Conditions
Temperature: 26 C
Relative Humidity: 38 %
ATM Pressure: 102kPa
30MHz-5GHz:
SG Frequency: 145MHz
Receiver Rx Antenna Cable Amplifier Corrected
Frequency Limit Margin
Reading Polar Factor loss Gain Amplitude
(MHz) Detector (dBμV/m) (dB)
(dBμV) (H/V) (dB(1/m)) (dB) (dB) (dBμV/m)
77.53 51.33 QP H 7.88 0.45 28.41 31.25 40.00 8.75
113.42 39.94 QP H 13.97 0.56 28.21 26.26 43.50 17.24
175.5 48.15 QP H 11.43 0.93 27.95 32.56 43.50 10.94
238.55 42.74 QP H 12.24 1.08 27.55 28.51 46.00 17.49
332.64 28.34 QP H 14.73 1.17 27.68 16.56 46.00 29.44
361.74 32.08 QP H 15.70 1.49 27.93 21.34 46.00 24.66
38.73 48.59 QP V 16.30 0.38 28.52 36.75 40.00 3.25
76.56 55.72 QP V 7.83 0.46 28.41 35.60 40.00 4.40
130.88 42.12 QP V 14.66 0.71 28.15 29.34 43.50 14.16
173.56 49.49 QP V 11.52 0.92 27.96 33.97 43.50 9.53
237.58 40.6 QP V 12.20 1.09 27.56 26.33 46.00 19.67
336.52 27.15 QP V 14.77 1.15 27.70 15.37 46.00 30.63
1245 45.68 PK H 23.44 2.32 26.57 44.87 74.00 29.13
1245 35.1 AV H 23.44 2.32 26.57 34.29 54.00 19.71
1130.261 51.39 PK V 23.14 2.16 26.68 50.01 74.00 23.99
1130.261 40.6 AV V 23.14 2.16 26.68 39.22 54.00 14.78
1350.701 52.57 PK V 23.71 2.46 26.47 52.27 74.00 21.73
1350.701 41.66 AV V 23.71 2.46 26.47 41.36 54.00 12.64
2452.906 50.98 PK V 23.36 3.00 26.88 50.46 74.00 23.54
2452.906 40.18 AV V 23.36 3.00 26.88 39.66 54.00 14.34
Applicable Standard
FCC §15.121
EUT Setup
For FCC §15.121 (b) Scanning Receiver Cellular Band Rejection Test
Power Supply
Test Procedure
2) Apply a RF signal to the receiver input port at lowest, middle and highest channel frequencies of
receiver operation band.
3) Adjust the audio output level of the receiver to it’s rated value with the distortion less than 10%.
4) Adjust the RF Signal Generator Output Power to produce 12 dB SINAD without the audio output
power dropping by more than 3 dB.This output level of the RF SG at each channel frequency is the
sensitivity of the receiver.
5) Select the lowest or worse-case sensitivity level for all of the bands as the reference sensitivity.
6) Adjust the RF Signal Generator output to a level of +60 dB above the reference sensitivity
obtained in step 5) and its frequency to the frequency points in the cellular band.
7) Set the Receiver squelch to threshold, the signal required to open the squelch must be lower
than the reference sensitivity level.
8) Set the receiver in a scanning mode and allow it to scan through it’s complete receiving range.
9) If the receiver unsquelched or stopped on any frequency, receiving at this frequency, then adjust
the signal generator output level until 12 dB SINAD is produced, this level is the spurious value and
the difference between the reference sensitivity and the spurious value is the rejection ratio and
must be at least 38dB.
10) Repeat above procedure at the frequencies 824.5, 836.0, and 848.5 MHz for the mobile band,
and 869.1, 881.5, and 893.5MHz for the cellular base band.
* Statement of Traceability: BACL (Chengdu) attested that all calibrations have been performed, traceable
to National Primary Standards and International System of Units (SI).
Test Data
Environmental Conditions
Temperature: 26 C
Relative Humidity: 38 %
ATM Pressure: 102kPa
EUT’s
Test Spurious Value of Reference
Scanning Rejection Rejection
Frequencies of Cellular Frequencies Sensitivity for
Frequency Ratio Ratio Limit
Cellular Band for 12 dB SINAD 12 dB SINAD
Band (dB) (dB)
(MHz) (dBm) (dBm)
(MHz)
824.5, 836.0,
144-148 848.5,
> -51.2 -116.5 < -65.3 < -38.0
420-450 869.1, 881.5,
893.5
Result
Compliance with the requirements specified in Part 15.121 for scanning receiver.