Hfe82v 300C
Hfe82v 300C
Features
● Ceramic brazing sealed technology guarantees no risk of arc
leaking and ensures no fire or explosion.
● Filled with gas ( mostly hydrogen) to effectively prevent the
oxidation burnt when exposed to electricity; the contact resistance
is low and stable, and the parts exposed to electricity can
meet IP67 protection level.
● Carrying current 300A continuously at 85°C.
● Insulation resistance is 1000MΩ(1000 VDC), and dielectric
strength between the coil and contacts is 2.6kV, which meets
the requirements of IEC 60664-1.
RoHS compliant
24 ≤18 ≥2 6
Max. switching voltage 1000 VDC
Max. breaking current 2000A(750 VDC)1op
Max. switching power 300kW
CHARACTERISTICS
Type 450V Type 750V
Insulation resistance 1000MΩ(1000 VDC)
Making:7.5×104ops Making:7.5×104ops
(Steady140A, (Steady140A, Between coil & contacts 2600 VAC 1min
Contact Voltage Contact Voltage Dielectric
20 VDC) 20 VDC) strength Between open contacts 2600 VAC 1min
Breaking:1000ops Breaking:500ops Operate time (at rated volt.) ≤30ms
(450 VDC,300A) (750 VDC,300A)
Electrical endurance 2) Release time (at rated volt.) ≤10ms
Breaking:1000ops Breaking:500ops
(450 VDC,-300A) (750 VDC,-300A) Close:588 m/s2
Shock Functional
Open:196 m/s2
Breaking:1op Breaking:1op resistance
(450 VDC,2000A) (750 VDC,2000A) Destructive 588m/s2
Breaking:1op Breaking:1op
Vibration resistance 10Hz ~ 500Hz 49m/s2
(450 VDC,-2000A) (750 VDC,-2000A)
Humidity 5% ~ 85% RH
300A:Cont.
Ambient temperature -40ºC ~ 85ºC
450A 5min
Current carrying 3) Load terminal structure M6 screw terminal female
600A 2min
capacity
Unit weight Approx.370g
900A 30s
Outline Dimensions 88.3x42.5x74.5mm(HC5)
1000A 25s 85.1x42.5x74.5mm(HC5Y)
Notes: 1) The above values are the initial values. Notes:The above values are the initial values measured at room temperature.
2) Unless otherwise specified, the temperature of eletrical endurance
is at 23°C and the on-off ratio is 0.6s:5.4s.
The coil was not connected to the surge suppression device
during the test. Please note that the use of a well-connected diode
will greatly increase the release time of the relay, resulting in a
reduced lifetime.
3) Ambient temperature is at 85°C and cross section area of wire
is 100mm2 min. See Fig. Endurance Capacity Curve for more
information.
HONGFA RELAY
ISO9001 IATF/TS16949 ISO14001 OHSAS18001 IECQ QC 080000 CERTIFIED 2022 Rev. 1.01
1
ORDERING INFORMATION
Outline Dimensions
HFE82V-300C/XXX-XX-H-C5-1
-0.5
0
2xM6
+1
0
56.5±0.3
25.5±0.3 2xØ6 0
+0.1
70.5±0.2
84.5±0.4
88.3±0.5
2
OUTLINE DIMENSIONS, MOUNTING HOLE, TERMINAL ARRANGEMENT Unit: mm
Outline Dimensions
HFE82V-300C/XXX-XX-H-C5-1(917)
-0.5
0
2xM6
+1
0
56.5±0.3
85.1±0.4
2xØ6 +0.1
0
25.5±0.3
70.5±0.2
84.5±0.4
2xØ6 +0.1
0
70.5±0.2
3
WIRING DIAGRAM Unit: mm
C:Connector
(Configured by customers:THB 0435 series, Yazaki 7283-1020)
Female housing:
0435316
Spacer:
0435318
Crimping terminal:
0117505
4
CHARACTERISTIC CURVES
100000
300A Cont.
Safe Operation Temperature
10000
450A 500s
Functional Temperature
1000 600A 200s
450A 300s Short-circuit Capacity Curve
1000A 50s
100 600A 120s
1200A 25s
1000A 25s
10
1200A 15s
1
5000A 350ms
0.1 6000A 150ms
7000A 60ms
0.01
8000A 6ms
0.001 10000A 1.5ms
100 1000 10000
Current (A)
Notes:
1.The upper limit of safe operation temperature and functional temperature are 180oC and 130oC respectively.
2.If the product needs to be operated for a long time, the upper temperature limit should not exceed 130oC.
3.The ambient temperature is 85oC, and the cross section area of the wire is ≥100mm2.
4.When the relay is operated under current ≥2000A for a long-term, it may weld without fire or explosion.
5.The dash-dotted line refers to the short-circuit capacity curve of the relay without fire or explosion; when the short-circuit current is≥6000A,
the contact may open.
9.0
8.0
Pick-up
7.0
6.0
5.0
4.0
3.0
2.0 Drop-out
1.0
0.0
-40 -20 0 20 40 60 85
Temperature(°C)
5
CAUTIONS
1. In case of loosening, please use washer when mount the relay with M5 screw, and the torque within 3N.m to 4N.m, The screw tightening torque
at terminals shall be within 6N.m to 8N.m. The torque beyond the range may cause damage.
Mounting for load terminal Mounting for relay body
Mounting way Torque requirement Hole dia. of copper bus bar Thickness of copper bus bar Mounting way Torque requirement
M6 Screw 6N.m ~ 8N.m Ø6.0mm~Ø6.5mm 2mm~3mm M5 Screw 3N.m ~ 4N.m
2. Relay terminal lock vertically, please pre-lock first and then lock when installing ,repeat locking is not recommended.
3. When the customer uses special crews and nuts,such as nylok,need to communicate and confirm with Hongfa.
4. When the customer has special installation requirement,such as upside down,multi busbar connection,need to communicate and confirm with Hongfa.
5. Be careful that oils and foreign matter do not stick to the main terminal part and please use the wire with min. cross section area 100mm2, otherwise
the terminal parts may have abnormal heating.
6. The recommended thickness of copper bus-bar is 3mm, otherwise it may cause screw loose or can not guarantee a tight mounting.
7. Cautions of mounting for relay body:
Unrecommended method
The hole of mounting plate at customer-side is too large.
Enlarged Schematic Diagram:
M6
Recommended method
The hole in mounting plate at customer-side is M5
Enlarged Schematic Diagram:
M5
Screw
Spring Washer
Flat Washer (Deformed)
When use M5 screw, the thickness and strength of the washer needs to be guaranteed
or it may deform and burst the cover.
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to choose
the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co.,Ltd. All rights of Hongfa are reserved.