Lecture 4 - HEN Design

This document discusses heat exchanger network (HEN) design for process integration and energy efficiency. It covers key concepts like the pinch point and rules for designing heat exchanger matches above and below the pinch to maximize energy recovery within minimum temperature differences.

Uploaded by

Rhuvaynn Vignesh
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 34

CEB4313 – PROCESS INTEGRATION

SYNYHESIS OF HEAT EXCHANGER


NETWORK (HEN)

HEN Design for MER

[email protected]
Significance of the ‘Pinch’
Steam@ 180ºC Heat Sink – only accepts heat
T (ºC) DHH Q
H
“Cooling above
“Heating below pinch”
pinch” • heat from
• Steam is used rejected to CW
for heating • must
of , instead compensate for
of hot stream loss of ∆HH with
• must add additional
CW for steam for
cooling of heating
“Pinch”

CW@ 30ºC
QC DHC
∆H (kW)
Heat Source – only rejects heat
Significance of the ‘Pinch’
Heat Sink = only accepts heat
DHH Q Cross Pinch Heat
H
Transfer - “upsets”
T (ºC)
the heat balance
X-Pinch heat
transfer Implications:
Not enough
process
heat above,
excess heat
below
“Pinch”
Simple Rule:
Exchange only
DHC high Temp with
QC high temp,
DH (kW) low T with low T
Heat Source – only rejects heat
Significance of the ‘Pinch’
Rules for HEN Design

“No Heating QH,min


below the
pinch”
T (ºC)

No heat
transfer

“No Cooling
above the
pinch”
H (kW)
QC,min
HEN DESIGN
HEN Design
Grid diagram

HOT 1

HOT 2 C

COLD 1

H COLD 2
• Hot streams run left to right
• Cold streams run right to left
• Hot streams on top; cold streams on bottom
• Hot utility = H
• Cold utility = C
• Heat exchanger between streams =
HEN Design
Showing the Pinch

PINCH

HOT 1 C

HOT 2

COLD 1

H COLD 2
HEN Design
Accounting for Pinch Implications

"Allowed" "Forbidden"

C C

The implications of the pinch are easily assessed!!


HEN Design
Rules for HEN design

• No process to process heat transfer across the pinch


• No inappropriate use of utilities
• No exchanger has a temperature difference < ΔTmin
HEN Design
Pinch design principle
T

1. Start at the Pinch

2. Then move AWAY

PINCH

ΔH
HEN Design
Above Pinch

TH, in TH, pinch

Tc, out Tc, pinch

CPH > CPC CPH ≤ CPC


T T
PINCH PINCH

∆Tmin ∆Tmin

ΔH ΔH
INFEASIBLE! FEASIBLE
HEN Design
Below Pinch

TH, pinch TH, out

Tc, pinch Tc, in

CPH < CPC CPH ≥ CPC


T T
PINCH PINCH

∆Tmin ∆Tmin

ΔH ΔH
INFEASIBLE ! FEASIBLE
HEN Design
Pinch design principle

1. Start at the Pinch

2. Above Pinch: CPH ≤ CPC

3. Below Pinch: CPH ≥ CPC


HEN Design
Divide at the pinch
CP
PINCH kW • (ºC)-1
170 º 100 º 60 º
3 3

150 º 100 º 30 º
4 1.5

135 º 80 º 20 º
1 2

140 º 80 º
2 4

QHmin = 65 kW QCmin = 105 kW


HEN Design
Design above the Pinch

Rule: CPH ≤ CPC

PINCH CP
170 º 100 º
3 3

150 º 100 º
4 1.5

135 º 80 º
1 2

140 º 80 º
2 4
HEN Design
Design below the Pinch

Rule: CPH ≥ CPC

PINCH CP

100 º 60 º
3 3

100 º 30 º
4 1.5

80 º 20 º
1 2
HEN Design
Sizing the matches

PINCH CP
170 º 100 º
3 3

150 º 100 º
4 1.5

135 º 80 º
1 2
? kW
140 º 80 º
2 4
? kW

Having identified feasible matches,


how big should we make them?
HEN Design
Tick-off heuristic (above pinch design)
CP QSTREAM
170 º 100 º
3 3 210
150 º 100 º
4 1.5 75

135 º 117.5º 80 º
1 2 110
75 kW
140 º 132.5º 80 º
2 4 240
210 kW
210
𝑇𝑥 = 80 + = 132.5℃
4
Maximise loads to "tick off" streams
HEN Design
Fill in the rest

CP QSTREAM
170 º
3 100 º 3 210
150 º
4 100 º 1.5 75

135 º 117.5º 80 º
H 1 2 110
35 kW 75 kW

140 º 132.5º 80 º
H 2 4 240
30 kW 210 kW
HEN Design
Tick-off heuristic (below pinch design)

PINCH CP QSTREAM

100 º 60 º
3 3 120

30 º
4 100 º 1.5 105

80 º 20 º 1 2 120

120 kW
HEN Design
Fill in the rest

PINCH CP QSTREAM

100 º 60 º
3 3 120

100 º 30 º 1.5
4 C 105
105 kW

20 º 80 º
1 2 120

120 kW
HEN Design
Completed design

PINCH CP
170 º 100 º 60 º
3 3

100 º 30 º
150 º 1.5
4 C
105 kW

135 º 117.5º 80 º 20 º
H 1 2
35 kW 75 kW 120 kW
140 º 132.5º 80 º
H 2 4
30 kW 210 kW

QHmin = 65 kW QCmin = 105 kW


HEN Design
Example
CP
PINCH kW • (ºC)-1
250 º 150 º 400 º
3 15

200 º 150 º 80 º
4 25

180 º 140 º 20 º
1 20
140 º
230 º
2 30

QHmin = 750 kW QCmin = 1000 kW


HEN Design
Example: Above Pinch

CP QSTREAM
250 º 203.3 º 150 º
2 15 1500

200 º 150 º 1250


4 25

180 º 140 º
1 20 800
800 kW

230 º 181.7 º 140 º


3 30 2700

1250 kW
HEN Design
Example: Above Pinch

CP QSTREAM
250 º 203.3 º 150 º
2 15 1500

200 º 150 º
4 25 1250

180 º 140 º
1 20 800
800 kW

230 º 205 º 181.7 º 140 º


H 3 30 2700
750 kW 700 kW 1250 kW
HEN Design
Example: Below Pinch

CP QSTREAM
150 º 40 º
2 15 1650

150 º 80 º
4 25 1750

140 º 52.5 º 20 º
1 20 2400
1750 kW
HEN Design
Example: Below Pinch

CP QSTREAM
150 º 106.7 º 40 º
2 C 15 1650
1000 kW
150 º 80 º
4 25 1750

140 º 52.5 º 20 º
1 20 2400
1750 kW 650 kW
HEN Design
Example: Below Pinch

This match violates CP rules


CP QSTREAM
150 º 106.7 º 40 º
2 C 15 1650
1000 kW
150 º 80 º
4 25 1750

140 º 52.5 º 20 º
1 20 2400
1750 kW 650 kW

But it is away from the pinch and therefore feasible


(Must check temperature though!)
HEN Design
Example: Completed design

PINCH
CP

250 º 203.3 º 150 º 106.7 º 40 º


2 C 15
1000 kW
200 º 150 º 80 º
4 25

180 º 140 º 52.5 º 20 º 20


1
800 kW 1750 kW 650 kW
230 º 205 º 181.7 º 140 º
H 3 30
750 kW 700 kW 1250 kW

QHmin = 750 kW QCmin = 1000 kW


HEN Design
Working Session 5

Stream data table


Heat
Supply Target
Stream No Capacity
Temperature Temperature
and Type Flowrate
(°C) (°C)
(kW/°C)
1 Hot 180 80 20
2 Hot 130 40 40
3 Cold 60 100 80
4 Cold 30 120 36

ΔTmin = 10 ºC

Design a Network for Maximum Energy Recovery


𝑻𝒑𝒊𝒏𝒄𝒉,𝒉𝒐𝒕 = 𝟕𝟎℃ 𝑻𝒑𝒊𝒏𝒄𝒉,𝒄𝒐𝒍𝒅 = 𝟔𝟎℃
HEN Design
Working Session 5

CP
STEP 2
70 º 43 º 40 º
2 1 40
C

120 kW
STEP 1

60 º 30 º
1 4 36

1080 kW
HEN Design
Working Session 5
CP

180 º 3 80 º
1 20

130 ºC 70 º
2 2 40

100 º 90 º 60 º
H1 2 3 80
800 kW 2400 kW
120 º 115.6 º 3 60 º 36
H2 4
160 kW 2000 kW
HEN Design
Working Session 5

Maximum Energy Recovery Network


CP

180 º 80 º
1 3 20

130 º 70 º 43 º 40 º
2 2 1 C 40
120 kW

100 º 90 º 60 ºC
H1 2 3 80
800 kW 2400 kW

120 º 115.6 º 60 º 30 º
4 H2 3 1 36
160 kW 2000 kW 1080 kW
HEN Design
Working Session 5
Again Maximum Energy Recovery
CP
140 º 80 º
1 180 º 4 3 20
130 º 70 º 43 º 40 º
2 2 1 C 40
120 kW

100 º 90 º 60 º 3
4 2 80
800 kW 2400 kW
120 º H 93.3 º 60 º 30 º
3 1 4 36
960 kW 1200 kW 1080 kW