The document discusses Protegra CS reverse osmosis and electrodeionization (RO/EDI) water purification systems. The systems combine RO and EDI technology to produce very high purity water with conductivities below 0.1 μS/cm. The systems are compact, easy to install and maintain, and provide consistent water quality without chemicals. They are suitable for applications requiring ultrapure water such as laboratories, electronics manufacturing, and pharmaceuticals.

Uploaded by

Chillie Hu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

Uv Open Channel

The document discusses Protegra CS reverse osmosis and electrodeionization (RO/EDI) water purification systems. The systems combine RO and EDI technology to produce very high purity water with conductivities below 0.1 μS/cm. The systems are compact, easy to install and maintain, and provide consistent water quality without chemicals. They are suitable for applications requiring ultrapure water such as laboratories, electronics manufacturing, and pharmaceuticals.

Uploaded by

Chillie Hu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PROTEGRA CS® RO/EDI

REVERSE OSMOSIS SYSTEM


CONSISTENTLY HIGH WATER QUALITY WITHOUT Degassing systems to reduce the CO2 content in feed
THE USE OF CHEMICALS water are available – they ensure that the system
The reverse osmosis Protegra CS® RO/EDI systems remains within feed water specifications and protect
are designed to serve the need for high volumes of the EDI-cell.
desalinated water. They produce pure water for many Benefits
applications. The combination of the Protegra CS RO
• Easy plug & play installation (Scope of supply
with the EDI-cell significantly increases the pure water
includes consumables)
quality.
• Compact service-friendly design, operable from all
The compact design with high-quality components sides
and intelligent control places great emphasis on cost- • Dust and splash proof
effectiveness. The plant systems are characterized by • RS 232 interface
a consistent pure water quality. Conductivities of < 0.1 • Service/maitenance report
µS/cm in single-phase and < 0.07 µS/cm in dual-phase • EDI module with separate cation and anion resin
systems are achieved. The TOC content is < 30 ppb. chambers
Germ reduction is achieved by means of the special • Made in Germany
arrangement of the separate bed process and a related
pH-value shift into the acidic range, preventing the Typical Applications
growth of bacteria in work spaces. No system operates • Feed for ultrapure water systems, laboratory
more efficiently and economically, since the EDI-cell washing machines, autoclaves, environmental
has a loss rate of only 10%. Low operating costs and chambers
a minimal maintenance outlay are features of this • General chemistry
system. • Buffer preparation
These systems can be individually equipped with • Photometry
additional options such as different tank sizes and • Spectrophotometry
pressure boosting systems. They represent the core • Protein electrophoreses
element in central water treatment plants in buildings • Microbiological media preparation
and are used with the options necessary for a ring • Electrophoreses
main operation. All systems have a RS 232 interface.
SPECIFICATIONS PROTEGRA CS RO/EDI, EDI-CELL SINGLE STAGE MODULE
Protegra CS RO/ Protegra CS RO/EDI Protegra CS RO/EDI Protegra CS RO/
EDI 120 260 500 EDI 750
Delivery flow rate l/h 120 260 500 750
Pure water quality µS/cm < 0.5 < 0.5 < 0.5 < 0.5
Typical pure water quality µS/cm < 0.1 < 0.1 < 0.1 < 0.1
Max. yield % 75 75 75 75
Max. working pressure bar 14 14 14 14
Power consumption kW/h 0.6 0.75 1.5 1.7
Power supply V/Hz 230 / 50 230 / 50 400 / 50 400 / 50
Dimensions (HxWxD) mm 1650 x 600 x 600 1650 x 600 x 750
Shipping weight kg 151 165 237 291
Catalog number W3T200007 W3T199823 W3T200009 W3T198152

SPECIFICATIONS PROTEGRA CS RO/EDI, EDI-CELL TWIN STAGE MODULE


Protegra CS RO/ Protegra CS RO/EDI Protegra CS RO/EDI Protegra CS RO/
EDI 120 260 500 EDI 750
Delivery flow rate l/h 120 260 500 750
Pure water quality µS/cm < 0.1 < 0.1 < 0.1 < 0.1
Typical pure water quality µS/cm < 0.07 < 0.07 < 0.07 < 0.07
Max. yield % 75 75 75 75
Max. working pressure bar 14 14 14 14
Power consumption kW/h 0.6 0.75 1.5 1.7
Power supply V/Hz 230 / 50 230 / 50 400 / 50 400 / 50
Dimensions (HxWxD) mm 1650 x 600 x 600 1650 x 600 x 750
Shipping weight kg 155 170 290 370

Catalog number W3T199822 W3T199619 W3T200008 W3T197525

SPECIFICATIONS PROTEGRA CS RO/EDI


Protegra CS Protegra CS Protegra CS RO/ Protegra CS
RO/EDI 120 RO/EDI 260 EDI 500 RO/EDI 750
Pressure bar 1-5 1-5 1-5 1-5
Conductivity µS/cm 2000* 2000* 2000* 2000*
Silt density index SDI < 12* < 12* < 12* < 12*
Free chlorine mg/l < 0.5* < 0.5* < 0.5* < 0.5*
Total iron mg/l < 0.1 < 0.1 < 0.1 < 0.1
SiO2** mg/l < 10 < 10 < 10 < 10
CO2** mg/l < 15* < 15* < 15* < 15*

Temperature °C 5 - 35 5 - 35 5 - 35 5 - 35

Hardness °dH 0 0 0 0

* with a pre-filter
** in total not larger than 20 mg/l

Auf der Weide 10, 89312 Günzburg, Germany

+49 (8221) 904-0 [email protected] www.evoqua.com/en/brands/lab

Protegra CS is a trademarks of Evoqua Water Technologies LLC, its subsidiaries or affiliates, in some countries. All information
presented herein is believed reliable and in accordance with accepted engineering practices. Evoqua makes no warranties as to
the completeness of this information. Users are responsible for evaluating individual product suitability for specific applications.
Evoqua assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse
of its products.

© 2019 Evoqua Water Technologies GmbH Subject to change without notice. Protegra CS RO EDI DE.PS.0419

You might also like