[GROUP 9 AUTOMATIC WARMINGUP FUNCTION "55
nusraces
See?
Pit ue
CPU comrler
1. Cluster reads engine coolant temperature through the temperature sensor, and if the cooiant
‘temperature is less than 30°C, it turns the warming-up lamp ON and sends warming-up control signal
{othe CPU controler.
2. When the CPU controler receives the warming-up control signal from the cluster, it changes the
‘governor motor position and set the engine speed 16 1250 pm, At the same time, the mode display
‘on cluster is not changed.
3. If the coolant temperature increases upto 30°C, or an operator changes mode set among the
‘warming up function, the CPU controller cancels the automatic warming up function.
‘4, Logle table(1)
Condition Function
- ~Mode : Defaut -
+ Coclant temperature : :
chats |“ othen ao ner enghoih) erg pti ot 1
-Warring-yp lamp : ON
~ Coclant temperature: above 30°C ~ Default mode
-Warrringup ime : above minutes | -Defaultmode
canceled | ~Chengedmode set by operator ~ Changed mode
+ Fany ofthe above conditions is
applicable, the euiomatic warring up
function is canceled
Were? | Coolant temperature: above 30°C \Werming-up lamp : OFF
5-155. Logic tabley2)
Coolanttemp. < 30°C | —Coolantternp. > 30°C Description
Signal Low(OVy High(6V)
Warring-up Cluster
one ON OFF
Mode Default Defauit ‘CPU controller