0% found this document useful (0 votes)
25 views

5 9

Uploaded by

Al Furkhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
25 views

5 9

Uploaded by

Al Furkhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 2
[GROUP 9 AUTOMATIC WARMINGUP FUNCTION "55 nusraces See? Pit ue CPU comrler 1. Cluster reads engine coolant temperature through the temperature sensor, and if the cooiant ‘temperature is less than 30°C, it turns the warming-up lamp ON and sends warming-up control signal {othe CPU controler. 2. When the CPU controler receives the warming-up control signal from the cluster, it changes the ‘governor motor position and set the engine speed 16 1250 pm, At the same time, the mode display ‘on cluster is not changed. 3. If the coolant temperature increases upto 30°C, or an operator changes mode set among the ‘warming up function, the CPU controller cancels the automatic warming up function. ‘4, Logle table(1) Condition Function - ~Mode : Defaut - + Coclant temperature : : chats |“ othen ao ner enghoih) erg pti ot 1 -Warring-yp lamp : ON ~ Coclant temperature: above 30°C ~ Default mode -Warrringup ime : above minutes | -Defaultmode canceled | ~Chengedmode set by operator ~ Changed mode + Fany ofthe above conditions is applicable, the euiomatic warring up function is canceled Were? | Coolant temperature: above 30°C \Werming-up lamp : OFF 5-15 5. Logic tabley2) Coolanttemp. < 30°C | —Coolantternp. > 30°C Description Signal Low(OVy High(6V) Warring-up Cluster one ON OFF Mode Default Defauit ‘CPU controller

You might also like