STICK (SMAW) ELECTRODE

WEARTECH® WT-6 SMAW


Cobalt • AWS A5.13 ECoCr-A

KEY FEATURES TYPICAL APPLICATIONS


• Cobalt, high chromium, tungsten electrode • Shear Blades
• Excellent for corrosion resistance, wear and galling • Fluid Flow Valves
• Most flexible and widely used of the cobalt alloys due to • Extrusion Screws
overall performance
• Roll Bushings
• Retains hardness up to 930ºF (500ºC)
• High Temperature
• Valve Bearing Surface

WELDING POSITIONS
All

DIAMETERS / PACKAGING
Diameter 10 lb (4.5 kg)
in (mm) Carton

3/32 (2.4) E1060-240X350


1/8 (3.2) E1060-320X350
5/32 (4.0) E1060-400X350
3/16 (4.8) E1060-480X350

DEPOSIT COMPOSITION
%C %Mn %Si %Cr %Ni

Requirements
AWS A5.13 ECoCr-A 0.7-1.4 2.0 max 2.0 max 25-32 3.0 max

Typical Results 1.2 0.9 1.1 27.3 2.5

%Fe %Mo %W %Co Hardness, Rc

Requirements
AWS A5.13 ECoCr-A 5.0 max 1.0 max 3.0 -6.0 Balance Not Required

Typical Results 3.3 0.1 4.60 58 41

TYPICAL OPERATING PROCEDURES


Current (Amps)
Polarity 1/8 in (3.2 mm) 5/32 in (4.0 mm) 3/16 in (4.8 mm)

DC+ 115-135 145-165 175-195

IMPORTANT: SPECIAL VENTILATION AND/OR EXHAUST REQUIRED


Fumes from the normal use of some welding products can contain significant quantities of components - such as chromium and manganese - which can lower the 5.0 mg/m3 maximum exposure guideline for
general welding fume.
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER.
Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

T E S T RE S U LT S
Test results for mechanical properties, deposit or electrode composition and diffusible hydrogen levels were obtained from a weld produced and tested according to prescribed stan-
dards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited to, weld
procedure, plate chemistry and temperature, weldment design and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding
consumable and procedure before use in the intended application.

CU S TO ME R AS S I S TA N CE P O LI CY
The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their
expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond to inquiries to the best of their ability based on informa-
tion provided to them by the customers and the knowledge they may have concerning the application. Our employees, however, are not in a position to verify the information provided or to evaluate the
engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume any liability with respect to such information or advice. Moreover, the provision
of such information or advice does not create, expand, or alter any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty
of merchantability or any warranty of fitness for any customers’ particular purpose is specifically disclaimed.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many
variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.

THE LINCOLN ELECTRIC COMPANY


Publication C7.15.5 | Issue Date 03/16 22801 St. Clair Avenue • Cleveland, OH • 44117-1199 • U.S.A.
© Lincoln Global, Inc. All Rights Reserved. Phone: +1.216.481.8100 • www.lincolnelectric.com

You might also like