Reinforced Concrete Column: Defining Condition
Reinforced Concrete Column: Defining Condition
C2
Design Parameters:
Main Bars Loc -Z Ast
h= 600 mm d' = 50 mm fs1 = 3 - 550.00 603.186
b= 300 mm Main bars = 16 mm Ø fs2 = 2 - 425.00 402.124
fc' = 21 Mpa Mux = 155.27 KNm fs3 = 2 - 300.00 402.124
fy = 275 Mpa Pu = 288.43 KN fs4 = 2 - 175.00 402.124
b₁ = 0.85 Escon = 600 Mpa fs5 = 3 - 50.00 603.186
Es = 200 Gpa Shear parameters
Defining Condition; Nvh = 2 , lateral ties leg
0.65 , Ԑt ≤ Ԑty if fs > fy, use fy Nvb = 5 , lateral ties leg
Ø= Val , Ԑty ˂ Ԑt ˂ 0.005 fyt = 230 Mpa, lateral ties
0.90 , Ԑt ≥ 0.005 Ties, Td = 10 mm Ø
Val = Use 0.65 in transition Region
MAXIMUM AXIAL CAPACITY Ag = 180000 NSCP 422.4.2.2
Pcn = 0.8 [0.85 fc' (Ag-As) + fy As] = 3,066.75 kN
Ø= 0.65 , Pcu = Ø Pcn = 1,993.39 kN
BALANCE CONDITION CAPACITY, Ø = 0.65 TENSION CONTROLLED CAPACITY,
Ԑy = fy / Es = 0.00138 Ԑt = -0.005
Cb = Ԑc d/Ԑc + Ԑy = 377.14 mm Ct = Escon d/(Escon-Es Ԑt) = 206.25
ab = βC = 320.57 mm at = βC = 175.31
from strain diagram As[fy or fs] from strain diagram As[fy or fs]
fs1 = 600(d-C)/C = 275.00 T1 = 165.88 KN, Tension fs1 = 600(d-C)/C = 1000.00 T1 =
fs2 = 600(C-Z2)/C = -76.14 C2 = -30.62 KN, Tension fs2 = 600(C-Z2)/C = -636.36 C2 =
fs3 = 600(C-Z3)/C = 122.73 C3 = 49.35 KN, Compression fs3 = 600(C-Z3)/C = -272.73 C3 =
fs4 = 600(C-Z4)/C = 321.59 C4 = 110.58 KN, Compression fs4 = 600(C-Z4)/C = 90.91 C4 =
fs5 = 600(C-Z5)/C = 520.45 C5 = 165.88 KN, Compression fs5 = 600(C-Z5)/C = 454.55 C5 =
Cc = .85 f'c ab = 1716.66 KN Cc = .85 f'c ab =
[∑Fv = 0], Pbn =C2+C3+C4+C5+Cc - T = 1846.0 KN [∑Fv = 0], Pbn =C2+C3+C4+C5+Cc - T =
[∑MT = 0], find e = x-z, z= 250.00 mm [∑MT = 0], find e = x-z, z= 250
PbnX = C2X2+C3X3+C4X4+C5X5+CcXc PbnX = C2X2+C3X3+C4X4+C5X5+CcXc
eb = 184.42 mm ØPb = 1199.9 KN et = 324.82 mm ØPt = 679.59
Mb = 340.43 KNm ØMb = 221.28 KNm Mt = 220.75 KNm ØMt = 198.67
ECCENTRICALLY LOADED SECTION CAPACITY, Ø = .90 CHECK SHEAR, Øv = 0.75
due to applied load, ex = 538.33 Vc = 0.17[1+(Pu/14Ag)]√fc' b dt = 143.25
[∑Fv = 0], Pbn =C2+C3+C4+C5+Cc -T Av = π Td² Nv / 4 = 157.1
[∑MT = 0], PbnX =C2X2+C3X3+C4X4+C5X5+CcXc Smax, min (16db, 48dties and least col dimension)
C = 160.83 mm a = 136.70 mm 16 db =
fs1 = 600(d-C)/C = 1451.92 T1 = 165.88 KN, Tension 48 dties =
fs2 = 600(C-Z2)/C = -985.57 C2 = 110.58 KN, Tension Least Column dimension =
fs3 = 600(C-Z3)/C = -519.23 C3 = 110.58 KN, Tension
fs4 = 600(C-Z4)/C = -52.88 C4 = 21.27 KN, Tension
fs5 = 600(C-Z5)/C = 413.46 C5 = 165.88 KN, Compression
Cc = .85 f'c ab = 732.04
Pnx = 489.60 ØPn = 440.64 KN > 288.43 Pass!
Mnx = 263.57 ØMn = 237.21 KNm > 155.27 Pass!
Therefore use, 600x300mm 12-16mm Ø longitudinal bars (GRADE 40) with 10mm Ø lateral ties space at,
2@50, 10@70mm , and Rest 200mm O.C, BOTH ENDS.
160.83 1
Lo = max [h, b, H/6, 450mm] = 600 mm
sh = min [0.25(min(h, b), 6 Td, 150mm] = 70 mm
0.900
3 - 16mm Ø
b
5 - 16mm Ø Inte
h 3,500.00
FORCE TRANSFER GUIDE FROM STAAD RESULT OR EQUIVALENT SOFTWARE
Mz (Staad) = Mux = 155.27 < 237.21 Pass! , ex =538.33 mm 3,000.00
My (Staad) = Muy = 4.12 < 29.88 Pass! , ey =14.28 mm
ØPnx = 440.64 > 288.43 Pass! > 440.6
2,500.00
ØPny = 2092.11 > 288.43 Pass! < 2092.1
, ex = 538.3 mm
2,000.00
Col Height, H = 3.05 Floor to Beam Bottom , ey = 14.3 mm
Ø = .90 Length factor, K = 0.5 Refer (Sheet 2) 29.9
< 1,500.00
mm Column Slenderness (Unbraced Column, KL/r ≤ 22), 406.2.5
mm KL/rx = 8.47 < 22 Ok! 8.47 <
1,000.00 22
As[fy or fs] KL/ry = 16.94 < 22 Ok! 16.94 < 22
165.88 KN, T 237.2 275.00 275.00
-110.58 KN, T 500.00 -76.14
-76.14
Dimension Limits, 418.7.2.1
-109.67 KN, T 250 mm 300 Ok!
36.56 KN, C Ratio Limit 0.4 0.50 Ok! - r
165.88 KN, C 0
8.47222 50 100
938.7984 KN Main reinforcement Ratio Ast = 2412.74 16.9444
755.1 KN 0.01Ag < Ast > 0.06Ag Ok! 177587.26
mm 1775.8725684 10655.235
Traverse Reinforcements, 418.7.5.4 2412.74 h 143.3
679.59 KN No of Leg Req, h = 4 Increase Leg! b 130.2
198.67 KNm No of Leg Req, b = 2 Ok! 217.751094797444
217.751094797444
143.25 130.23 KN 256 217.751094797444
157.1 392.7 mm² At Lo only Vc = 143.25
east col dimension) At Lo only 143.25 550.0 157.1
256 mm 130.23 250.0 392.7
480 mm Side = h m With Seismic Provision, NSCP 2015 Sec 418.7.5
300 mm H Col mark Vu Vs Smax Seismic req QTY DIST
0 - 0.1m 39 (91.25) 217.75 50 2 50 Pass!
Lo
0.1 - 0.6m 39 (91.25) 217.75 70 10 70 Pass!
Mid > 0.6m 39 (91.25) 217.75 100 Rest 200 Fail!
Vs = (Vu/Ø) - Vc First lat ties Min of 50mm from Face of Support
S = Av fyt d / Vs
1
000.00
1 1 k
0 FALSE 1 790
500.00 0 FALSE 1
0 #N/A 1 -0.002
000.00 5 -0.005
275 40
415 60
T
Cs'
Cc
ONTROLLED CAPACITY,
SION CONTROLLED CAPACITY,
with
mm