HM 80225
HM 80225
G400, G600
Hardware Reference Guide
MK-94HM8022-05
June 2016
© 2015, 2016 Hitachi, Ltd. All rights reserved.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic
or mechanical, including copying and recording, or stored in a database or retrieval system for
commercial purposes without the express written permission of Hitachi, Ltd., or Hitachi Data Systems
Corporation (collectively “Hitachi”). Licensee may make copies of the Materials provided that any such
copy is: (i) created as an essential step in utilization of the Software as licensed and is used in no
other manner; or (ii) used for archival purposes. Licensee may not make any other copies of the
Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents.
Hitachi reserves the right to make changes to this Material at any time without notice and assumes
no responsibility for its use. The Materials contain the most current information available at the time
of publication.
Some of the features described in the Materials might not be currently available. Refer to the most
recent product announcement for information about feature and product availability, or contact
Hitachi Data Systems Corporation at https://support.hds.com/en_us/contact-us.html.
Notice: Hitachi products and services can be ordered only under the terms and conditions of the
applicable Hitachi agreements. The use of Hitachi products is governed by the terms of your
agreements with Hitachi Data Systems Corporation.
By using this software, you agree that you are responsible for:
1. Acquiring the relevant consents as may be required under local privacy laws or otherwise
from authorized employees and other individuals to access relevant data; and
2. Verifying that data continues to be held, retrieved, deleted, or otherwise processed
in accordance with relevant laws.
Notice on Export Controls. The technical data and technology inherent in this Document may be
subject to U.S. export control laws, including the U.S. Export Administration Act and its associated
regulations, and may be subject to export or import regulations in other countries. Reader agrees to
comply strictly with all such regulations and acknowledges that Reader has the responsibility to obtain
licenses to export, re-export, or import the Document and any Compliant Products.
Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries.
AIX, AS/400e, DB2, Domino, DS6000, DS8000, Enterprise Storage Server, eServer, FICON,
FlashCopy, IBM, Lotus, MVS, OS/390, PowerPC, RS/6000, S/390, System z9, System z10, Tivoli,
z/OS, z9, z10, z13, z/VM, and z/VSE are registered trademarks or trademarks of International
Business Machines Corporation.
Active Directory, ActiveX, Bing, Excel, Hyper-V, Internet Explorer, the Internet Explorer logo,
Microsoft, the Microsoft Corporate Logo, MS-DOS, Outlook, PowerPoint, SharePoint, Silverlight,
SmartScreen, SQL Server, Visual Basic, Visual C++, Visual Studio, Windows, the Windows logo,
Windows Azure, Windows PowerShell, Windows Server, the Windows start button, and Windows Vista
are registered trademarks or trademarks of Microsoft Corporation. Microsoft product screen shots are
reprinted with permission from Microsoft Corporation.
iPad is a trademark of Apple Inc., registered in the U.S. and other countries.
All other trademarks, service marks, and company names in this document or website are properties
of their respective owners.
2
Hitachi Virtual Storage Platform G400, G600 Hardware Reference
Contents
Preface......................................................................................................................7
Safety and environmental notices..............................................................................................8
General safety guidelines.............................................................................................................9
Handling of heavy parts......................................................................................................10
Preventing electric shock....................................................................................................10
Avoiding rotating or moving parts.....................................................................................10
Preventing machine damage..............................................................................................11
Working when the storage system is turned on.............................................................11
Precautions when using the storage system...................................................................11
Procedures in an emergency..............................................................................................12
For electric shock...........................................................................................................12
For fire.............................................................................................................................12
Intended audience......................................................................................................................12
Product version...........................................................................................................................13
Release notes..............................................................................................................................13
Changes in this revision.............................................................................................................13
Document conventions..............................................................................................................13
Conventions for storage capacity values.................................................................................14
Accessing product documentation...........................................................................................15
Getting help.................................................................................................................................15
Comments....................................................................................................................................15
1 Product overview.............................................................................................17
Block configuration.....................................................................................................................19
File- and block-level configuration...........................................................................................19
Hitachi Virtual Storage Platform G400 model.........................................................................19
Hitachi Virtual Storage Platform G600 model.........................................................................20
Features........................................................................................................................................22
Scalability.....................................................................................................................................22
Examples of supported Hitachi Virtual Storage Platform G400 configurations..........22
Examples of supported Hitachi Virtual Storage Platform G600 configurations..........22
Maximum number of mounted drive trays.......................................................................23
3
Hitachi Virtual Storage Platform G400, G600 Hardware Reference
2 Hardware description.....................................................................................25
Storage system controllers........................................................................................................26
CBLM controller.....................................................................................................................26
CBLM with front panel bezel........................................................................................26
CBLM front panel without bezel..................................................................................27
CBLM rear panel.............................................................................................................28
Controller interfaces...................................................................................................................30
Front end module descriptions...........................................................................................30
8 Gbps Fibre Channel board LEDs and connectors..................................................30
16 Gbps Fibre Channel board LEDs and connectors................................................31
10 Gbps iSCSI board LEDs and connectors (optical)...............................................32
10 Gbps iSCSI board LEDs and connectors (copper)...............................................33
LAN blade LEDs and connectors........................................................................................34
Back end module LEDs and connectors............................................................................35
Storage system drive trays........................................................................................................35
Small form factor (SFF) drive tray.....................................................................................35
SFF with front panel bezel............................................................................................35
SFF front panel without bezel......................................................................................36
SFF rear panel................................................................................................................37
Large form factor (LFF) drive tray.....................................................................................38
LFF with front panel bezel............................................................................................38
LFF front panel without bezel......................................................................................38
LFF rear panel................................................................................................................39
Flash module drive (FMD) tray...........................................................................................40
FMD with front panel bezel..........................................................................................40
FMD front panel without bezel....................................................................................41
FMD rear panel...............................................................................................................42
Dense intermix drive tray...................................................................................................43
Dense intermix drive tray with front panel bezel......................................................43
Dense intermix drive tray display LEDs......................................................................44
Dense intermix drive tray rear panel..........................................................................45
SFF and LFF AC power supply unit LEDs and connectors..............................................46
Hitachi Virtual Storage Platform SVP server...........................................................................46
Service processor description.............................................................................................46
SVP front panel.....................................................................................................................47
SVP rear panel......................................................................................................................48
Index....................................................................................................................121
□ Intended audience
□ Product version
□ Release notes
□ Document conventions
□ Getting help
□ Comments
Preface 7
This symbol on the product or on its packaging means that your electrical and electronic equipment
should be disposed at the end of life separately from your household wastes.
There are separate collection systems for recycling in the European Union. For more information,
contact the local authority or the dealer where you purchased the product.
Recycling
A nickel-metal hydride battery is used in the Cache Backup Battery.
A nickel-metal hydride battery is a resource that can be recycled. When you want to replace the
Cache Backup Battery, call the service personnel. They will dispose of it for you. This nickel-metal
hydride battery, which is designated as recycling product by a recycling promotion low, must be
recycled.
The mark posted on the Cache Backup Battery is a three-arrow mark that indicates a recyclable part.
8 Preface
Preface 9
Read the following safety guidelines carefully and follow them when you
conduct maintenance of the machine:
• Do not use materials that are outside the specifications for the storage
system.
• Use the spare parts, consumables, and materials for maintenance that are
specified in this manual; otherwise, personal injury, system damage, and
degradation in system quality can occur.
• Keep the maintenance area neat.
• Always put away parts, materials, and tools when not in use.
10 Preface
Procedures in an emergency
For electric shock
• Before performing maintenance, be sure that there is no potential electric
hazard in the maintenance area, such as insufficient grounding or a wet
floor.
• Before performing maintenance, observe where the emergency poweroff
switches are located and be sure you know how to operate them.
• Unless otherwise instructed, remove all power sources to the storage
system before starting work. Switching off the storage system power
supplies is not sufficient. When power is fed from a wall or floor outlet,
unplug the power supply cord, or turn off the switch on the power
distribution panel or board.
• If the power supply has a lockout device, lock the device after powering off
the storage system and retain the key. Attach a notice on the panel or
board prohibiting the use of the switch.
• If the machine power has been already turned off, confirm that
these conditions have been satisfied.
For fire
Intended audience
This document is intended for system administrators, Hitachi Data
Systems representatives, and authorized service providers who install,
configure, or operate VSP Gx00 models .
Release notes
Read the release notes before installing and using this product. They may
contain requirements or restrictions that are not fully described in this
document or updates or corrections to this document. Release notes are
available on Hitachi Data Systems Support Connect: https://
support.hds.com/en_us/documents.html.
Document conventions
This document uses the following typographic conventions:
Convention Description
Bold • Indicates text in a window, including window titles, menus, menu options,
buttons, fields, and labels. Example:
Click OK.
• Indicates emphasized words in list items.
Italic • Indicates a document title or emphasized words in text.
• Indicates a variable, which is a placeholder for actual text provided by the
user or for output by the system. Example:
pairdisplay -g group
(For exceptions to this convention for variables, see the entry for
angle brackets.)
Monospace Indicates text that is displayed on screen or entered by the user. Example:
pairdisplay -g oradb
< > angle brackets Indicates variables in the following scenarios:
Preface 13
Logical storage capacity values (for example, logical device capacity) are
calculated based on the following values:
14 Preface
Open-systems:
• OPEN-V: 960 KB
• Others: 720 KB
1 KB 1,024 (210) bytes
1 MB 1,024 KB or 1,0242 bytes
1 GB 1,024 MB or 1,0243 bytes
1 TB 1,024 GB or 1,0244 bytes
1 PB 1,024 TB or 1,0245 bytes
1 EB 1,024 PB or 1,0246 bytes
Getting help
Hitachi Data Systems Support Connect is the destination for technical support
of products and solutions sold by Hitachi Data Systems. To contact technical
support, log on to Hitachi Data Systems Support Connect for contact
information: https://support.hds.com/en_us/contact-us.html.
Comments
Please send us your comments on this document to [email protected].
Include the document title and number, including the revision level (for
example, -07), and refer to specific sections and paragraphs whenever
possible. All comments become the property of Hitachi Data Systems
Corporation.
Thank you!
Preface 15
The storage systems have dual controllers that provide the interface to a data
host. Each controller contains its own processor, dual in-line cache memory
modules (DIMMs), cache flash memory (CFM), battery, and fans. Each
controller also has an Ethernet connection for out-of-band management using
Hitachi Device Manager - Storage Navigator. If the data path through one
controller fails, all hard drives remain available to data hosts using a
redundant data path through the other controller. The storage system allows
a defective controller to be replaced.
The Virtual Storage Platform G400, G600 can be equipped with NAS
modules. The NAS modules provide file access through CIFS, NFS and FTP
protocols and block access using iSCSI protocols in addition to the block
access provided directly by iSCSI and FC I/O modules.
□ Block configuration
□ Scalability
18 Product overview
Hitachi Virtual Storage Platform G400, G600 Hardware Reference
Block configuration
A block configuration supports the Fibre Channel and Internet Small
Computer System Interface (iSCSI) protocols, and consists of:
• Two controllers
• One or more drive trays
• One 1U block service processor server (SVP)
Product overview 19
Related references
• Examples of supported Hitachi Virtual Storage Platform
G400 configurations on page 22
Related references
• Examples of supported Hitachi Virtual Storage Platform
G600 configurations on page 22
Scalability
All storage systems offer pay-as-you-grow scalability by allowing you to
hot- add drives as you need them.
Maximum number of
Drive tray Maximum number of drives supported
drive trays
supported
22 Product overview
4 48 FMDs
4 48 FMDs
Number of mounted drive trays for VSP G400 Maximum number of mounted drives for VSP
(up to 12 per path) G400
16 0 384 192
13 1 372 216
12 2 408 264
9 3 396 288
8 4 432 336
5 5 420 360
4 6 456 408
1 7 444 432
0 8 480 480
Product overview 23
The maximum number of drive trays that can be installed per path is 8.
Number of mounted drive trays for VSP G600 Maximum number of mounted drives for VSP
(up to 6 per path) G600
24 0 576 288
21 1 564 312
20 2 600 360
17 3 588 384
16 4 624 432
13 5 612 456
12 6 648 504
9 7 636 528
8 8 672 576
5 9 660 600
4 10 696 648
1 11 684 672
0 12 720 720
The maximum number of drive trays that can be installed per path is 12.
24 Product overview
□ Controller interfaces
Hardware description 25
Hitachi Virtual Storage Platform G400, G600 Hardware Reference
Storage system controllers
Every storage system has two controllers. The controllers contain fans and
power supplies, and provide the interfaces between a host and the
storage system.
A controller manages the I/O between the host system and data volumes.
CBLM controller
CBLM with front panel bezel
26 Hardware description
Note: Removing a controller can cause the POWER, READY, WARNING, and
ALARM LEDs on the front panel to activate. These LEDs return to the on
status after the storage system recovers from the controller replacement.
Hardware description 27
7 ALM LED (for cache flash Red: Cache flash memory can
memory) be removed.
28 Hardware description
4 LAN blade
Hardware description 29
1 NAS module
2 Front end module
4 LAN blade
Controller interfaces
Controllers provide interfaces for connecting, powering, and configuring and
managing the storage system. They also have LEDs to show the status of the
storage system.
30 Hardware description
Port Assignments
CHB-1A 1A 3A 5A 7A
CHB-1B 1B 3B 5B 7B
CHB-1C 1C 3C 5C 7C
CHB-1D 1D 3D 5D 7D
CHB-1E 1E 3E 5E 7E
CHB-1F 1F 3F 5F 7F
CHB-1G 1G 3G 5G 7G
CHB-1H 1H 3H 5H 7H
CHB-2A 2A 4A 6A 8A
CHB-2B 2B 4B 6B 8B
CHB-2C 2C 4C 6C 8C
CHB-2D 2D 4D 6D 8D
CHB-2E 2E 4E 6E 8E
CHB-2F 2F 4F 6F 8F
CHB-2G 2G 4G 6G 8G
CHB-2H 2H 4H 6H 8H
Hardware description 31
Port Assignments
CHB-1A 1A 3A
CHB-1B 1B 3B
CHB-1C 1C 3C
CHB-1D 1D 3D
CHB-1E 1E 3E
CHB-1F 1F 3F
CHB-1G 1G 3G
CHB-1H 1H 3H
CHB-2A 2A 4A
CHB-2B 2B 4B
CHB-2C 2C 4C
CHB-2D 2D 4D
CHB-2E 2E 4E
CHB-2F 2F 4F
CHB-2G 2G 4G
CHB-2H 2H 4H
32 Hardware description
Hardware description 33
Off: no link.
3 PORT LED Green: link has been made.
Blinking: communication is
occurring.
34 Hardware description
Hardware description 35
36 Hardware description
1 ENC N/A
2 POWER LED Green: ENC is in the power-on
state.
3 LOCATE LED • This LED indicates the
location of the chassis.
• The LED can be lit or turned
off by the maintenance
utility.
Hardware description 37
38 Hardware description
8 9 10 11
4 5 6 7
0 1 2 3
1 ENC N/A
2 POWER LED Green: ENC is in the power-on
state.
3 LOCATE LED Amber:
Hardware description 39
40 Hardware description
Slow blink:
• DKC-F710I-1R6FM/3R2FM:
insufficient battery capacity
in the flash module drive.
• DKC-F810I-1R6FN/3R2FN/
6R4FN: flash module drive
built-in capacitor is charged.
If the storage system is
turned on, the LED stops
blinking when the capacitor
is charged completely
(about two minutes).
Hardware description 41
9, 10, 11
6, 7, 8
3, 4, 5
0, 1, 2
1 ENC N/A
2 POWER LED Green: ENC is in the power-on
state.
3 LOCATE LED Amber:
• This LED indicates the
location of the chassis.
• The LED can be lit or turned
off by the maintenance
utility.
42 Hardware description
Hardware description 43
Note: Drives are organized as follows, starting from the rear of the drive
tray and moving left to right. In the above figure on the left, the rear of the
drive tray is at the top.
• Rear of drive tray: 48 - 59
• 36 - 47
• 24 - 35
• 12 - 23
• Front of drive tray: 00 - 11
44 Hardware description
Hardware description 45
Note: This product is also designed for IT power distribution systems with
phase-to-phase voltage.
46 Hardware description
Three of the four RJ-45 ports (the ones that connect to the controllers and
the IP network) are configured as a bridge. The SVP can be addressed using
the default IP address 192.168.0.15.
In the unlikely event you cannot connect to the SVP using the default IP
address, use the following emergency login: http://<default SVP IP
address>/dev/storage/<model number><system serial number>/
emergency.do. For example:
Users are responsible for adopting the appropriate security procedures with
the SVP, including:
• Applying Windows security patches.
• Turning on automatic Windows updates or using the manual
Windows update method.
• Installing antivirus software that has been tested and approved by Hitachi.
• Installing the latest SVP firmware releases from Hitachi.
Hardware description 47
Number Description
LAN3 LAN4
LAN1 LAN2
Note: After the Initial Startup Wizard is run, the SVP can be used in non-
bridge mode. In this mode, the cables can be removed from SVP ports LAN3
and LAN4 and attached to switches. For more information, contact customer
support.
48 Hardware description
At installation, the modes are set to their default values, as shown in the
following table. If you think these mode settings should be changed, discuss
these settings with your Hitachi Data Systems team. The System Option
Modes can be changed by a Hitachi Data Systems representative only.
The following table was up to date at the time this manual was published.
However, the System Option Mode information might change in firmware
releases that precede the next release of this manual. Contact your Hitachi
Data Systems team for the latest information about System Option Modes.
Note:
Mode 22 = ON:
73-03-01-00/00 or higher: 64
Mode 22 = OFF:
Mode 80 = ON:
Mode 80 = OFF:
Notes:
122 For Split or Resync request from the Mainframe host OFF
and Storage Navigator,
(1) For HUS VM, this mode is applied to use scripts etc
that are used on Lightning 9900 and Lightning 9900 V.
Mode 292=ON:
When switching the port attribute, issue the OLS (100 ms)
first, and then reset the Chip.
Mode 292=OFF:
Notes:
Note:
The mode 448 setting takes effect only when mode 449 is
set to OFF.
Mode 449 = ON
Notes:
*a:
*b:
Notes:
Note that the line band can be changed from the window for
changing JNL group options.
467 In case of using the following features, the current copy ON
processing slows down if the dirty percentage is 60% or
larger, and it stops if the dirty percentage is 75% or larger.
Mode 467 is to prevent the dirty percentage from over 60%
so that the host performance is not affected.
Notes:
471 Since the SIM-RC(*) that are generated when the usage OFF
rate of Pool used by Snapshot exceeds the threshold value
can be resolved by users, basically they are not reported to
the maintenance personnel.
- HUS VM:
Notes:
- HUS VM:
Notes:
enabled.
Note:
Even when mode 506 is set to ON, the Delta Resync may
fail and only the total data copy of the Delta Resync
function is allowed if the necessary journal data does not
exist on the primary subsystem used for the Delta Resync
operation.
561 This option is used to allow Quick Restore for OFF
external volumes with different Cache Mode settings.
589 When this option is ON, the frequency of progress update of OFF
disconnection is changed.
Notes:
689 This option is used to slow down the initial copy and resync OFF
copy operations when the Write Pending rate on RCU
exceeds 60%.
Notes:
690 This option is used to prevent Read JNL or JNL Restore OFF
when the Write Pending rate on RCU exceeds 60% as
follows:
696 This mode is available to enable or disable the QoS function. OFF
Note:
701 This option is used to issue the Read command at the OFF
LU discovery operation using UVM.
Notes:
704 To reduce the chance of MIH, this option can reduce the N/A
priority of SI, VM, CoW Snapshot, Flash Copy or Resync
copy internal IO requests so that host IO has a higher
priority. This mode creates new work queues where
these jobs can be assigned with a lower priority.
Note:
Notes:
Notes:
Not to set the Protect attribute for the target DP-VOL using
the DRU, when any Write operation is requested to the
area where the page allocation is not provided at a time
when HDP Pool is full.
Notes:
-The threshold of Pool is high (e.g., 95%) and the Pool may
be full.
USP V/VM:
Notes:
Notes:
Notes:
745 This option enables to change the area where the OFF
information is obtained as the Characteristic1 item from
SYMMETRIX.
Notes:
2. Enable the setting of EMC SCSI Flag SC3 for the port of
the SYMMETRIX storage of EMC connected with USP V/VM
and disable the setting of Flag SPC2. If the setting of EMC
SCSI Flag SC3 is not enabled or the setting of Flag SPC2
is enabled, the effect of this mode may not be achieved.
Notes:
Notes:
Notes:
(3) This function is available for all the TC Sync and GAD
pairs on the subsystem, unable to specify the pairs that
are using this function or not.
(11) The mode works for the pair for which initial
pair creation or Resync operation is executed.
(15) The mode does not support paths between DKCs using
iSCSI in VSP Gx00/Fx00. (Configuration where DKC paths
of Fibre and iSCSI coexist is not supported.)
803 While a DP pool VOL is blocked, if a read or write I/O is OFF
issued to the blocked pool VOL, this mode can enable the
Protect attribute of DRU for the target DP-VOL.
Notes:
Notes:
857 This option enables or disables to limit the cache allocation OFF
capacity per MPB (VSP / VSP G1000) or MPU (HUS VM) to
within the prescribed capacity (*) except for Cache
Residency.
Notes:
Notes:
Notes:
Notes:
1. Apply the mode when the usage of upper tier is low and
that of lower tier is high.
898 By the combination of System Option Mode 898 and 897 OFF
setting, the expansion width of Tier Range upper I/O
value (IOPH) can be changed as follows.
Notes:
899 In combination with the system option mode 900 setting, OFF
whether to execute and when to start the I/O synchronous
copy change as follows.
Notes:
Notes:
For tier1 (drive type is SSD), pages are allocated until the
capacity reaches the limit.
Notes:
Notes:
908 The mode can change CM capacity allocated to MPBs with OFF
different workload.
Notes:
Example:
930 When the mode is set to ON, all of the zero data page OFF
reclamation operations in processing are stopped. (Also the
zero data page reclamation cannot be started.)
See the system option mode 930 sheet for relationship with
system option mode 755.
Notes:
Notes:
Notes:
1070 The mode changes the processing for a group operation OFF
with GAD CTG.
Notes:
1097 This mode disables the warning LED to blink when specific Inactive
SIMs are reported.
Note:
□ Removing cables
Power up the flash module drives using power from the storage system for
at least 90 minutes every month. Failing to do so may render a flash module
drive unusable and will abrogate replacement under the terms of the
warranty.
1. Press the main switch for three seconds until the POWER LED blinks.
2. Verify that the POWER LED on the front of the storage system
changes from green to amber.
It can take from 25 minutes to 4 hours for the POWER LED to turn amber,
depending on the configuration of the system (check after 33 minutes).
3. To stop the power supply from supplying power, remove the power
cables from the power supply units on the controller chassis and drive
box.
If the storage system is connected to a PDU, you can stop the power
supply by turning off the PDU breaker.
Note: If the storage system does not receive power for more than
six months, the battery can become discharged and possibly
damaged. To avoid this situation, charge the battery for more than
three hours at least once every six months.
Removing cables
Observe the following instructions when removing cables form the storage
system.
To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch
and remove the SAS cable (2).
To remove a LAN cable, push the top of the LAN cable connector (1)
to release the latch and remove the LAN cable (2).
The following table lists the required roles for using specific Maintenance
Utility operation windows.
Procedure
3. Create a new user account. Specify the User Name, Account Status,
Authentication and User Group. Click Finish.
Procedure
4. Click Edit.
5. For Account Status, click Disable, and then click Finish.
Procedure
4. Click Remove.
The Confirm window opens.
Procedure
Procedure
□ Model lists
□ Replacement parts
□ Electrical specifications
□ Environmental specifications
□ Battery specifications
□ RAID specifications
□ iSCSI specifications
□ iSCSI standards
□ Regulatory compliance
DW800-CBL 4U chassis 1
Power supply unit 2
Backup module 8
DW-F800-CTLM Controller 2
DW-F800-BAT Battery 6
DW-F800-DBF 2U chassis 1
ENC 2
Power supply unit 2
Power cable (0.9 m) 2
Power cable (2.5 m) 2
Front bezel (2U) 1
Power cables
SAS cables
Optical cables
Replacement parts
Part replacement is required to maintain high performance. Replacement of
parts is covered by the maintenance service contract.
Battery unit
Replacement period
Three years.
Note: The battery is designed to protect the data in the cache memory in an
emergency, such as a sudden power failure. In these situations, follow the
normal power down procedure. If not, the battery might reach its lifespan
earlier than expected and become unusable within three years. When
replacing the battery, follow the given procedure for disposing a used
battery.
1 CBLM
Drive tray
1 SFF drive tray
1 LFF drive tray
1 FMD drive
tray
1 Dense intermix drive tray
Drive size
Item Specification
2.5-inch drive (SFF) 3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm)
3.5-inch drive (LFF and dense intermix 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm)
drive tray)
Flash Module Drive (flash module drive 5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm)
tray)
3.5-inch drive (LFF and dense intermix 393.85, 1152.79, 1729.29, 3916.14, 5874.22
drive tray)
Mixing SFF, LFF, FMD, and dense intermix drive trays might affect
the maximum number of drives that can be mounted.
SFF 24
LFF 12
Host interface
RAID specifications
D: Data drive, P: Parity drive.
Item Specification
VSP G600:240
Maximum volume size 3 TB (or 4 TB if using the LDEVs of other storage
systems)
Maximum volumes/host groups and iSCSI 2048
targets
Maximum volumes/parity groups 2048
Item Specification
SDRAM 1 G bytes
Start-up time
Item
Chassis size
Dense intermix drive tray 18.97 x 40.51 x 6.92 inches (482 x 1,029 x 176
mm)
(includes the depth of the cable-management
arms)
Mass (value of maximum configuration when all controllers and drives are
mounted)
Component Specification
Required height
Component Specification
CBLM 4U
SFF 2U
LFF 2U
DBF 2U
Dense intermix drive tray 4U
Cache specifications
Item Specification
Note:
• All 12 slots must be fully installed
with DIMMs.
• Each DIMM is replaceable when they
fail.
• The DIMM is not common and
cannot be used with DKC DIMM.
When the storage system enters Cache Backup mode, the amber WARNING
LED goes on to when the system starts. This warning indicates that the
battery charge has dropped significantly and the remaining battery capacity
is not sufficient; the storage system will continue operating with the Write
Cache function disabled.
When the battery is charged, the warning indication disappears, and the
storage system continues the operation in the Write Cache function.
The warning indication disappears within six hours. Even when the warning is
shown, normal operation is assured in Write-Through. Read and write
performance is lowered because the Write Cache function is disabled.
If the storage system is not charged for more than six months, the battery
can become overcharged and sustain unrecoverable damage. To avoid this
situation, charge the battery more than 3 hours every six months.
Insulation performance
Electrical specifications
Item Controller Drive tray
Input voltage (operable voltage AC 200-240 +6%/-11% SFF, LFF, FMD, and dense
range) (V) intermix drive tray: AC 200-240
+6%/-11%
Frequency (Hz) 50/6 ±1
0
Number of phases, cabling Single-phase with protective grounding
Heat value (normal) (kJ/h) CBLM: 2160 or less SFF drive tray: 1120 or less
Steady-state power (VA/W)3 CBLM: 1600/1560 or less SFF drive tray: 480/460 or less
Environmental specifications
Temperature
Caution: The following VSP Gx00/Fx00 storage system components are not
supported in high-temperature environments. Do not operate the following
components at temperatures of 40°C or higher:
• DB60 dense drive tray
• HDS provided service processor (SVP) server
• First-generation FMDs (non-DC2 FMDs)
Transport, storage -22°F to 140°F -22°F to 140°F -22°F to 140°F (-30°C to 60°C)
(-30°C to (-30°C to
60°C) 60°C)
Temperature 10 or less
change rate
(°C/h)
Temperature 10 or less
change rate
(°C/h)
State Percentage
Operating 8 to 80
Non-operating 8 to 90
Vibration
State m/s2
Impact
State m/s2
Operating 20 or less
(10 ms, half sine wave)
Non-operating 50 or less
(10 ms, half sine wave)
Transport (packed) 80 or less
Altitude
Dense intermix
State Controller SFF and LFF drives
drive tray
Atmosphere
Avoid areas exposed to corrosive gas and salty air.
Acoustic Noise
32°C or less)1
Non- 55 dB 55 dB 71 dB (Environmental
operati temperature 32°C or less)1, 2,
ng 3, 4
Notes:
1. The system's internal temperature controls the rotating speed of the fan module. Therefore,
this standard value might be exceeded if the maximum load continues under high-
temperature environment or if a failure occurs in the system.
2. Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient
temperature, drive configuration, and operating status. Maximum volume can reach 79 dB
during maintenance procedure for a failed ENC or power supply.
3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes
from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating
status.
Battery specifications
The following table shows the lifetime expectancy of the batteries installed in
the storage system.
RAID specifications
SFF, LFF, dense
Item Controller intermix drive trays
(range for setup)
iSCSI specifications
Item Specification Comments
Host connections 255 (maximum per iSCSI port) With Linux software
initiator, the maximum
number decreases.
Maximum transfer unit (MTU) 1,500, 4,500, 9,000 bytes Jumbo frame, MTU size greater
(Ethernet frame) than 1500
iSCSI name Both iqn3 and eui4 types The unique iqn value is
are supported automatically set when a target
is made. iSCSI name is
configurable.
CHAP user registration Max 512 users per iSCSI port N/A
Note:
1. JP1, HiCommand Dynamic Link Manager. Pass switching is achieved. Not supported on
Microsoft Windows Vista and Windows 7 operating systems.
2. IP Security. Authentication and encryption of IP packets. The storage system does not
support IPsec.
3. iqn: iSCSI Qualified Name. The iqn consists of a type identifier, "iqn," a date of domain
acquisition, a domain name, and a character string given by the individual who acquired the
domain. Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar
4. eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and
an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef
iSCSI standards
The following standards apply to the management, maintenance, and iSCSI
data ports. To configure this system, use switches that comply with the
following standards:
• IEEE 802.1D STP
• IEEE 802.1w RSTP
• IEEE 802.3 CSMA/CD
• IEEE 802.3u Fast Ethernet
• IEEE 802.3z 1000 BASE-X
• IEEE 802.1Q Virtual LANs
• IEEE 802.3ad Dynamic LACP
• IEEE 802.3ae 10 Gigabit Ethernet
• RFC 768 UDP
• RFC 783 TFTP
• RFC 791 IP
• RFC 793 TCP
• RFC 1157 SNMP v1
• RFC 1231 MIB II
• RFC 1757 RMON
• RFC 1901 SNMPv2
Regulatory compliance
This equipment has been tested and certified for compliance with the
following standards.
KN22 KC Korea
KN24 KC Korea
EN61000-3.2:2006+A1 CEmarking EU
+A2
EN61000-3.3:2008 CEmarking EU
EN60950-1:2006+A1 CEmarking EU
Caution: The HDS supplied SVP server is not supported in high temperature
environments. Do not operate the SVP server at temperatures of 40°C or
higher.
• Cores: 2
• SmartCache: 2 MB
Index 121
U
P user administration 83
parts, replacement 103
powering off the storage system 81
R
RAID specifications 113
rear panels
CBLM controller 28
dense intermix drive tray 45
flash module drive tray 42
large form factor drive tray 39
service processor 48
small form factor drive tray 37
regulatory compliance 117
removing cables 81
removing user accounts 91
replacement parts 103
restoring user account information 94
roles 84
S
SAS cables
removing 81
scalability 22
service processor
front panel 47
122 Index
Corporate Headquarters
2845 Lafayette Street
Santa Clara, California 95050-2639
U.S.A.
www.hds.com
Americas
+1 408 970 1000
[email protected]
Asia Pacific
+852 3189 7900
[email protected]
MK-94HM8022-05
June 2016