Assignment
Assignment
1. A Building is to be constructed over a site that has the soil stratification shown in Fig1 :
Using the data given below, design rectangular footing:
Determine the area of a rectangular footing that can safely transfer the load from the superstructure
without shear failure, i.e. bearing capacity failure.
Determine the depth of the footing and provide the necessary reinforcements and show the
reinforcement details/sketches.
Check the requirement for Development length, Embedment Length for Column Reinforcement, and
bearing stress.
The load from the superstructure; DL =2000KN, LL=500 Mx=1000Kn.m, & My = 10 Kn.m.
The footing is to be placed at a depth of 1.5 m below the ground surface.
Assume the foundation to be a flexible foundation.
Ground water table exists at ground surface.
Use concrete C-30 and steel S-400.
Column size: 35 cm by 50cm with 8Φ20
Use Hansen’s Bearing Capacity equation. Use F.S= 2.
Design method:-Limit state design method and class I work
Fig.1Subsurface profile
2: (Combined footing)
Design the combined footing shown in Fig.2 below having property line restriction at C1 if the column loads
from the superstructure are as follows:
Table 1:
Axial Mx
Column size load(KN) (KN.m) My(KN.m)
C1 40cmx40cm 500 0 0
C2 35cmx35cm 1600 0 0
3: (Combined footing)
Design a rectangular combined footing shown in Fig.3 below for the loading conditions shown in table 2:
Table 2: