0% found this document useful (0 votes)
27 views

2017 559 Seg en KB

This document provides information on the Belt Conveyor-Pull Rope Switch SEG, including its application, function, technical data, selection table, mounting, connection drawing, and dimensions. The SEG is an emergency stop switch used on conveyor belt systems as a supplementary safety measure. It has a cast iron housing, red release lever, and blue reset lever. Actuating the pull rope triggers the emergency stop signal via positively opening contacts.

Uploaded by

01666754614
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

2017 559 Seg en KB

This document provides information on the Belt Conveyor-Pull Rope Switch SEG, including its application, function, technical data, selection table, mounting, connection drawing, and dimensions. The SEG is an emergency stop switch used on conveyor belt systems as a supplementary safety measure. It has a cast iron housing, red release lever, and blue reset lever. Actuating the pull rope triggers the emergency stop signal via positively opening contacts.

Uploaded by

01666754614
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Belt Conveyor-Pull Rope Switch

SEG

Leaflet No. Kiepe 559


APPLICATION
Kiepe pull-rope emergency stop switches type SEG are used in Kiepe pull-rope emergency stop switch types SEG comply with
accordance with the requirements of EN 620 as well as BGI 710 and Machinery Directive 2006/42/EC.
in conformity with DIN EN ISO 13850 as emergency stop devices as They must only be used in control electrical circuits.
supplementary safety measures on conveyor belt systems. The pull
The SEG cast iron housing offers space for up to 3 simultaneously
rope is symmetrically tensioned on both sides of the red release
switching NO and NC contacts. Taking into consideration the safety
lever.
data and maintenance recommendations, the pull-rope emergency
The devices are suitable for outdoor use and applications where stop switch type SEG can be used in safety circuits in accordance
the ambient temperature varies considerably. with DIN EN ISO 13849 up to Performance Level e (PLe).
With the pull-rope system functionally aligned, the emergency
stop signal can be triggered over a distance of up to about 100 m
for each switch.

FUNCTION
The pull-rope emergency stop switch is actuated by a pull rope 1 The emergency stop signal is performed with positive-making
connected on both sides of the red release lever. The contacts are normally closed (NC) contacts in accordance with the closed circuit
actuated by a spring supported cam disc (snap action function). principle.
At the same time, up to three NC and NO contacts are actuated After the emergency stop function is triggered, the switching
simultaneously and a cross comparison of the contacts can be mechanism is locked in the shut-off position "0". When the blue
performed with an external control unit. reset lever is actuated in switch position "1", the switching con-
tacts are reactivated and the conveyor belt is prepared for being
turned back on again.
Resetting the pull-rope emergency stop switch must not cause the
conveyor system to start up.

T E C H N I C A L D ATA

Designation Pull-rope emergency stop switch type SEG


Emergency stop device with latching function
Type of actuation Bidirectional
Spring-loaded ("snap action")
Complies with DIN EN ISO 13850; DIN EN 60947-5-5;
DIN EN 60947-5-1
Suited for Control units and systems in accordance with DIN EN 60204

Mechanics
Enclosure Cast iron, EN-GJL-200
Finish DD-paint
Enclosure – yellow (RAL 1004)
Release lever – red (RAL 3000)
Reset lever – blue (RAL 5010)
Mounting 2 slotted holes for M10 screws
Installation position Horizontal, tilt angle up to about 15°
Pull-rope length Up to approx. 100 m
Actuation force 30 N ± 10 N
Weight 5.23 kg
Electrical system
Switching system Up to 3 NC and NO contacts
Cam operated positive-making switches
Cable entry Threaded holes 2x M25 x 1.5 with each 1x screwed cable gland:
Sealing area Ø 11 mm to Ø 16 mm; 1x screw plug
Utilization category AC-15: 230 V; 6 A
DC-13: 110 V; 1.1 A
Connection cross section 1 mm2 to 2.5  mm2
Protective conductor connection In the casing; M4
Rated insulation voltage Ui 400 V
Rated impulse withstand voltage Uimp 2.5 kV, degree of pollution III
Conventional thermal current Ith 16 A
Contact reliability 1 2 million switching operations
Ambient conditions in accordance with DIN EN 60947-5-5
Permissible ambient temperature -25°C ... +70°C
Extended ambient temperature range -40°C ... +70°C (type SEG 7xx)
Protection rating IP 67 in accordance with EN 60529
Safety data in accordance with DIN EN ISO 13849 and EN 61062
Safety functions Emergency stop incl. latching
Manual reset
Usable in accordance with DIN EN ISO 13849-1 Up to PLe (depending on customer application)
B10d value 24,000 actuations

S E L E C T I O N TA B L E

Type Contact Integrated Order number


configuration signal lamp
NC NO
SEG 001 1 1 91.056 400.001
SEG 002 2 2 91.056 400.002
SEG 004 1 1 x 91.056 400.004
SEG 005 2 2 x 91.056 400.005
Further models available on request

Equipment options:
Gold-plated contacts
Ventilation membran
Signal lamps for 230 V or 24 V
Devices for two-wire bus line

Spare parts and accessories:


Screwed cable gland M25 x 1.5 (sealing area 11 mm to 16 mm) 113.52.02.20.01
Screw plug M25 x 1.5 113.52.87.20.02
Replacement lamp: BA 15D 220 V-260 V / 5 W 331.09.08.02.01

MOUNTING
Pull-rope emergency stop switches of types SEG are each fastened as well as the protective conductor connection. The pull-rope 1 is
to the substructure in installation position with 2 M8 screws, tensioned by tension springs 2 between the anchor hooks 3 and
centered between the anchor hook 3 of the pull-rope system (see fastened onto the red release lever.
the mounting diagram).
After the tension springs 2 have been adjusted, the actuation
Electrical connection is performed with the device open using the force and path for triggering the switch must be tested to ensure
screwed cable gland included in the delivery, directly on the screw compliance with specified requirements.
joints of the switching elements and the lamp fitting (option)

MOUNTING DIAGRAM

release lever
3 2 5 8 7 6 1 7 4

1 Pull rope 5 Quick link


2 Tension spring 6 Rope support
3 Anchor hook 7 Clamp
4 Turnbuckle 8 Thimble
CONNECTION DRAWING
Switching elements in accordance with DIN EN 60617
(the maximum configuration is shown)

DIMENSIONS

15° 15°
M25 x 1.5

M25 x 1.5
11
141

124
12

38

177

11
101

70

205

Subject to change without notice.