Notice:
1. Please read the instruction manual carefully before using the product to avoid damage or accident.
2. Lights should be handled with care.
3. The light should be wired correctly.,
4. The light is not suitable for direct installation on the surface of ordinary combustible materials.
5. Please check the fixture carefully before installation. If any abnormal condition, please contact us .
6. Make sure the lamps are intact before the installation
7. Screws and bolts must be fastened tightly and reliably when installation
8. Installation requires guidance from qualified personel. It could be used outdoors.
Make sure the foundation can support the luminaire.
9.The light source in this luminaire must be replaced by the staff of supplier, the designated
agent, or the similarly qualified electrician only
10. This product is maintenance-free and generally does not require maintenance. Please contact us if you need
maintenance.
www.darmon.com 1/6
Installation guide for S5 All in one solar street light 20-50w
一体式太阳能路灯安装示意图(20~50W)
M8 Set screws
and fastening nuts
Camera
(Optional) Cap
Installation diagram
AC driver (optional)
Set screws and fastening nuts
AC driver (optional)
AC driver (optional)
AC driver (optional)
60.0mm Yellow-green (G) 60.0mm
Yellow-green (G) Blue (N)
Blue (N) Brown (L)
Brown (L)
Assembly steps:
1. According to the unpacking instructions, take out all the lamp accessories and place them on a flat table;
2. The assembly method of the All in one type (20~50W) : open the cover on the hoop bracket, tighten the 4 M8 fastening screws, then lock the cover on the
hoop bracket with screws, and rotate the camera to the card holder (Note: The camera is optional), and finally install it on the lamp body with reference to
the integrated hoop bracket.
Wiring : Connect each wires of the power supply cable to the input wires of the lamp correspondingly, and the input wires of the lamp: brown to the power
grid L (fire wire), blue to the power grid N (zero line), yellow-green wire to the power grid G (ground wire ), and wrap with fire-resistant insulating tape
according to safety regulations. (This wiring scheme is applicable to AC driver type).
Installation steps:
1. Loosen the machine screws fixed on the hoop bracket ;
2. In the direction of the arrow shown in the figure, align the mouth of the fixed hoop bracket with the pole, and slowly slide the pole to the top . ( hoop
bracket angle can be adjusted by ±15°, metal plate angle cannot be adjusted) .
3. Check the level bubble below the lamp. Rotate the light fixture to keep it parallel to the road direction. Tighten 4 machine screws, and finally tighten 4
fastening nuts.
www.darmon.com 2/6
Installation guide for S5 All in one solar street light 60-120w
M8 Set screws
and fastening nuts
Cap
Camera (Optional) Hoop (φ50~60)
Optional parts
AC driver (optional)
Optional parts
Assembly steps:
1. According to the unpacking instructions, take out all the lamp accessories and place them on a flat table;
2. The assembly method of the All in one type (60~120W) : connect the wires between the solar panel and the lamp body, then open the upper cover of the
lamp body, fasten it to the solar panel with screws, lock the lamp with butterfly screws, and install it on the lamp body with reference to the integrated hoop
bracket.
Wiring : Connect each wires of the power supply cable to the input wires of the lamp correspondingly, and the input wires of the lamp: brown to the power
grid L (fire wire), blue to the power grid N (zero line), yellow-green wire to the power grid G (ground wire ), and wrap with fire-resistant insulating tape
according to safety regulations. (This wiring scheme is applicable to AC driver type).
Installation steps:
1. Loosen the machine screws fixed on the hoop bracket ;
2. In the direction of the arrow shown in the figure, align the mouth of the fixed hoop bracket with the pole, and slowly slide the pole to the top . ( hoop
bracket angle can be adjusted by ±15°, metal plate angle cannot be adjusted) .
3. Check the level bubble below the lamp. Rotate the light fixture to keep it parallel to the road direction. Tighten 4 machine screws, and finally tighten 4
fastening nuts.
www.darmon.com 3/6
Installation guide for S5H (20-80w) Installation guide for S5F(20-120W)
Camera (Optional)
Cap
Hoop (φ50~60)
AC driver (optional)
Yellow-green (G)
AC driver (optional)
Blue (N)
Brown (L)
Yellow-green (G) AC driver
(optional)
Blue (N)
Brown (L)
Assembly steps:
1. According to the unpacking instructions, take out all the lamp accessories and place them on a flat table;
2. Open the cover on the hoop bracket, tighten the 4 M8 fastening screws, then lock the cover on the hoop bracket with screws, and rotate the camera to the
card holder (Note: The camera is optional), and finally install it on the lamp body with reference to the integrated hoop bracket.
Wiring : Connect each wires of the power supply cable to the input wires of the lamp correspondingly, and the input wires of the lamp: brown to the power
grid L (fire wire), blue to the power grid N (zero line), yellow-green wire to the power grid G (ground wire ), and wrap with fire-resistant insulating tape
according to safety regulations. (This wiring scheme is applicable to AC driver type).
Installation steps:
1. Loosen the machine screws fixed on the hoop bracket ;
2. In the direction of the arrow shown in the figure, align the mouth of the fixed hoop bracket with the pole, and slowly slide the pole to the top . ( hoop
bracket angle can be adjusted by ±15°, metal plate angle cannot be adjusted) .
3. Check the level bubble below the lamp. Rotate the light fixture to keep it parallel to the road direction. Tighten 4 machine screws, and finally tighten 4
fastening nuts.
www.darmon.com 4/6
Exceptions
Display Area
B1: Press the "+" and "-" keys at the same time to bring up the [Remote Control Settings]
interface and set the correct password.
A: Wrong password
B2. Press the "+" and "-" keys at the same time to bring up the [Remote Control Settings]
Remote controller B: Wrong working mode(IR or wireless)
1 interface, and then select [Infrared Remote Control] or [Wireless Remote Control].
doesnot work C:Short wireless remote distance setting
C1: Press the "+" and "-" keys at the same time to bring up the [Remote Control Settings]
D: Low battery
interface, and then increase the [Remote Distance] option before testing.
D1: Please replace 2 AA (No. 5) batteries.
The red indicator light A1. Check whether the battery board is charged normally and whether the battery board
flashes quickly, the is covered.
4 A Low battery
LED light is off A2. Check whether the battery and battery board wiring is disconnected or loose.
A1. Check whether the battery board is charged properly and the battery board
A: Low battery configuration is correct.
5 Short lighting time
B: High LED lamp power output A2. Select the "Smart Power" option
B1. Check whether the controller current setting is correct and the load power is normal.
A1. please check whether the load wiring is correct and whether the positive and negative
of the LED are reversed.
The red indicator A. LED light is of open circuit B1. please check whether the load wiring is short-circuited, whether the positive and
flashes slowly, and B. LED lamp wiring if of short circuit or The negative LEDs are reversed
7 the LED lamp does number of LED lights in series is too small B2. Please check whether the LED light string is correct and replace the LED lamp with
not light. C. battery is over temperature the one of right number of light strings.
C1. pay attention to the installation environment.
C2. Check whether the setting of <High Temperature Work> is reasonable.
www.darmon.com 5/6
Exceptions
Display area
LIGHT
Flashlight On/Off
BACK
Upward Return
OK
Downward OK
A1. Please check whether the load wiring is correct and whether the positive and negative
poles of the LED are reversed.
A. LED light is open-circuited or the wiring
B1. Please check whether the load wiring is short-circuited, whether the positive and
Controller indicator is short-circuited.
3 flashes quickly B. The battery is overcharged or
negative poles of the LEDs are connected
B2. Please check whether the battery is overcharged (waiting for the lithium battery voltage
overdischarged
to drop to the overcharge return voltage and automatically resume charging) or
overdischarge (wait for charging).
A1. Check whether the battery board is charged properly and the battery board configuration
A Low battery is correct.
5 Short lighting time
B: High power output A2. Open the "Smart Mode" option and set it to high
B1. Check whether the controller current setting is correct and the load power is normal.
www.darmon.com 6/6