0% found this document useful (0 votes)
88 views

Compact MCCB

The document describes Schneider Electric's Compact MCCB product line, which ranges from 100A to 3200A. It includes the Compact NSX line from 100A-630A, the Compact NS line from 630A-1600A, and another Compact NS line from 1600A-3200A. It provides details on their sizes, ratings, types of tripping devices, performance levels, standards compliance, installation methods, and available auxiliaries and accessories.

Uploaded by

bolu8jam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views

Compact MCCB

The document describes Schneider Electric's Compact MCCB product line, which ranges from 100A to 3200A. It includes the Compact NSX line from 100A-630A, the Compact NS line from 630A-1600A, and another Compact NS line from 1600A-3200A. It provides details on their sizes, ratings, types of tripping devices, performance levels, standards compliance, installation methods, and available auxiliaries and accessories.

Uploaded by

bolu8jam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 95

ComPact MCCB

Angelina Priscilla
SGP Associate – Business Offer Manager
Power Products

Confidential Property of Schneider Electric

Internal
The 100 to 3200 A Compact range
Schneider Electric's moulded case reference range

Compact NS
1600b to 3200

Compact NS
630b to 1600

Compact NSX
400 to 630

Compact NSX
100 to 250

Schneider Electric - EasyPact TVS - 11/2012 2


Internal
The 100 to 630 A Compact NSX range
Advanced, high-performance and flexible

LV circuit breaker or switch ( 690 V)

Fixed or withdrawable

2 sizes, 5 ratings
● 100/160/250 A: 2P (3P), 3P, 4P
● 400/630 A: 3P, 4P Fixed version

3 types of tripping devices


● Thermomagnetic up to 250 A
● Electronic
● Advanced electronic incorporating
measurement and communication

Switchboard display unit Withdrawable version


Accessories and auxiliaries
Schneider Electric - EasyPact TVS - 11/2012 3
Internal
The 630b to 3200 A Compact NS range

2 sizes, 8 ratings
● 630/800/1000/1250/1600 A : 3P, 4P
● 1600/2000/2500/3200A : 3P, 4P

Reduced safety clearance ensured by


the arc chute filters

Limiter built into the same volume

Micrologic control unit

Auxiliaries and control units common


with Masterpact NT and NW

Schneider Electric - EasyPact TVS - 11/2012 4


Internal
Icu and Ics performance of
Compact NSX 100 to 630A
New performance levels

Icu (kA) 415 V Ics = 100 % Icu


L 150

S 100

H 70
N 50
F 36
B 25

NSX100 NSX160 NSX250 NSX400 NSX630

Schneider Electric - EasyPact TVS - 11/2012 5


Internal
Icu and Ics performance of
Compact NS 630b to 3200A

Icu (kA) 415 V Ics performance en % Icu

LB 200

L 150

H 70 85

N 50 70

630b 800 1000 1250 1600 1600b 2000 2500 3200

Schneider Electric - EasyPact TVS - 11/2012 6


Internal
International standards

CSA
IEC
UL IEC JIS

IEC

IEC
IEC

Marine Certifications

Schneider Electric - EasyPact TVS - 11/2012 7


Internal
Way of installation 1/2

On panel On rail On rail DIN

NSX 100 to 250 n n n

NSX 400 to 630 n n

NS 630b to 1600 n n

NS 1600b to 3200 n

Panel Rail DIN rail


Schneider Electric - EasyPact TVS - 11/2012 8
Internal
Way of installation 2/2
Installation Connection Control

Withdr. Withdr. on Rear Front By


fixed manual electric rotary
on base chassis connec. connec. cable

NSX 100 to 250 n n n n n n n n n

NSX 400 to 630 n n n n n n n n n

n n n n n n n n
NS 630b to 1600
LB save

NS 1600b to 3200 n n n

fixed Withdrawable on base Withdrawable on chassis


Schneider Electric - EasyPact TVS - 11/2012 9
Internal
Protection
- Wide choice of interchangeable
tripping devices
- Trip units for Compact NSX 100 to
630A
- Trip units for Compact NS 630b to
3200A
Trip units for Compact NSX 100 to 630A

Compact NSX 100 to 250 Compact NSX 400 to 630

Thermo-magnetic
TM-D/TM-G

Micrologic 2.2/ 2.2-M/Vigi4.2 Micrologic 2.3/2.3E-M/ Vigi 4.3

Measurement
Communication
Micrologic 5/6.2 (E/E-M) Micrologic 5/6.3 (E/E-M)

Schneider Electric - EasyPact TVS - 11/2012 12


Internal
Trip units for Compact NS 630b to 3200A

2. 0 A Type of current protection None A E P

2 : Distribution L, I 2.0 2.0 A 2.0 E


Type of
current
protection 5 : Selective L, S, I 5.0 5.0 A 5.0 E 5.0 P

Version 6 : Selective and earth-fault protection


L, S, I, G 6.0 6.0 A 6.0 E 6.0 P

Type of 7 : Selective protection with


measurement earth-leakage protection L, S, I, V 7.0 A 7.0 E 7.0 P

Schneider Electric - EasyPact TVS - 11/2012 13


Internal
Auxiliaries and
accessories
- Auxiliaries and accessories Compact
NSX 100 to 630A
- Auxiliaries and accessories Compact
NS 630b to 1600A
- Auxiliaries and accessories Compact
NS 1600b to 3200A
Auxiliaries and accessories
Compact NSX 100 to 630A
Electrical auxiliaries

Auxiliary contacts

Rotary handle

Motor mechanism

Locking

Connection

Measurement unit

Schneider Electric - EasyPact TVS - 11/2012 15


Internal
Auxiliaries and accessories
Compact NS 630b to 1600A
Electrical auxiliaries

Auxiliary contacts

Rotary handle

Spreader

Lead-seal cover

Motor mechanism

Locking

Operation counter

Connection

Schneider Electric - EasyPact TVS - 11/2012 16


Internal
Auxiliaries and accessories
Compact NS 1600b to 3200A
Electrical auxiliaries

Auxiliary contacts

Locking

Connection

Schneider Electric - EasyPact TVS - 11/2012 17


Internal
New Offer
ComPacT NS

Confidential Property of Schneider Electric

Internal
1. New Trip unit design
Only cosmetic evolution
• Plastic dark grey
• New labels and keypads
No functional evolutions
• Same electronic
• Same physical shapes

New CR created only for MCCB


• Trip units (including switch)
• Long time rating plugs
• Sensor plugs
• Performer plugs

Internal
2. New front cover design
Transparency to align with ComPacT NSX & NSXm

A
• Front cover
A
• New material & marking B
• New color for push-to-trip + new marking
• New color for Neutral rotary switch
C
• New nameplate labels
D

•Rotary handle: (direct & extended)

B D
C

Internal
3. New toggle design
Ergonomic touch and visibility to align with ComPacT NSX & NSXm

Improve ergonomic Improve visibility


• Soft touch material • Toggle with integrated LED as an option
• Consistent with small MCCBs design • LED blinking in trip position

Internal
4. New meaningful commercial references
ComPacT NS630b – 3200A New Generation
New meaningful and simpler commercial references (complete breaker)
Old reference New reference
33478 C 12 N 3P 20 F M

NS 1250A 50kA 3Poles Mic 2.0 Fixed Manual


Breaking capacity kA
Range Rating (A) Number of poles Trip unit type Fixed or Withdrawable Manual or Electrical
220/415 V
C: NS 06: 630A N: 50 kA 3P: 3 poles 20 : Mic 2.0 F : Fixed M : Manual operated
08: 800A H: 70 kA 4P: 4 poles 50 : Mic 5.0 W : Withdrawable E : Electrical
10: 1000A L: 150 kA 60 : Mic 6.0
12: 1250A LB: 200 kA 2E : Mic 2.0E
16: 1600A NA: switch 5E : Mic 5.0E
20: 2000A 6E : Mic 6.0E
25: 2500A 7A : Mic 7.0A
32: 3200A …..

…..

Approx. 460 new commercial references.


Internal
Accessories
Accessories impacted by the project additional to common accessories with ComPacT NSX

Make internal accessories visible :


• MN/MX → add a label visible through the window

Optional OF/SD :
• Zigbee
• Screwless for fixed version

• Other accessories → no change

Internal
New ComPacT NS scope
What is in scope:
• Manual operated
(breaker + switch)
(fixed and withdrawable)
• Trip unit
• Toggle
• Rotary handles (in later delivery)
• Coil
• Auxiliary contact OF/SD

What is out of scope:


• Electrically Operated. Other accessories not impacted, motor mechanism, terminals, interphase barriers,
terminal shields, escutcheon ….

Internal
GoPact MCCB
Robust | Simple
The high-quality, affordably priced answer to the competitive diffused market

Angelina Priscilla
SGP Associate – Business Offer Manager
Power Products

Confidential Property of Schneider Electric

Internal
MCCB | Target Segments
Market Residential Buildings Data center Energy Industry
segments

Sub
segments Multi- Comm. Hotel Hospital Industrial Data center Utility Renewable Light industry O&G MMM Transporta Telecom
home buildings buildings (…) tion

Social housing, Comm.+ Govt. Non-star, < 50 bed / Non Critical


Low spec Packaging Poultry Crude Palm Textile
Target for Standard resi Low end Tier 4-5 community Bldgs:
Material Agri Oil (CPO) EV Charger
apps, Utility
Basic bldg. (incomer) buildings, cities hospitals Warehouse
Boards Handling Cooperative Petrol Pump
Retail Stores Packaging

Confidential Property of Schneider Electric | Page 26

Internal
Robust
Mechanical Life | Electrical Life | Temperature resilience

High Mechanical Life High Electrical Life High Temperature Resilience


15,000 to 30,000 cycles 3,000 to 8,000 cycles Operates at 55C without derating1

The Robust built ensures “Fit and Forget” for most diffused applications

Confidential Property of Schneider Electric | Page 27


1 Except for GoPact 125 (40C)
Internal
Simple
Simplified offer structure | Optimized reference list

Documentation Selection Ordering Installation


Simplified catalogue Optimized reference list (299 Nos) mySE Accessories: Click based
Pictorical instruction sheet Product Selector Ecommerce Ergonomic plug in base

A Simplified Offer for the New and Experienced users of the diffused market

Confidential Property of Schneider Electric | Page 28

Internal
Introducing GoPact MCCB!
5 (GoPact 125 to 800)
Frame Sizes

TMD1 (Fixed and Adjustable thermal) & ETU2


Trip Units (200 breaker references)

10KA to 70KA
Breaking Capacity

16A to 800A
Rated Current

3P3D & 4P4D3


Poles

Wide Range (99 references)


of Accessories

Confidential Property of Schneider Electric | Page 30


1 TMD: Thermal Magnetic 2 ETU: Electronic Trip Unit 3 100% overload protection on 4th poleInternal
GoPact | Offer Overview

Rated Current (A)

16 125

20 160

25 200

32 250

40 320

50 400

63 500

80 630

100 800
● TM-D + Thermal Adjustability - meeting needs of standard electrical distribution & utility business
● Cover Medium Offer gap @800 A (TMD + E.T.U.)
● Open to E-commerce GTM
Internal
GoPact | Accessories
Insulation Auxiliaries Power Connection Accessories

Short Terminal Shield Terminal Extension Shunt Trip


Spreaders Release
(MX)
Long Terminal Shield Rear Connectors

Internal Accessories
External Accessories

Interphase Barriers Steel bare cable connectors Voltage


Release
(MN)

Control Accessories Electrical Auxiliaries


Auxiliary
Contact
(OF)
Direct Rotary Handle Plug in Base Kit

Extended Rotary Handle Trip Alarm


Contact
Conversion Kit for (SD)
Plug In Base

Confidential Property of Schneider Electric | Page 32

Internal
Offer Specifics
Setting up ETU | Plug In Base | Rotary Handle with Padlocking

Confidential Property of Schneider Electric | Page 37

Internal
Adjusting Thermal Settings | GoPact125 - 800 (TMD)
Overload protection settings adjustable on all TMD breakers

GoPact125 GoPact200-800
Maximum In & Ii ● Knob based adjustability for setting Ir
(across frames)

In Ii ● 0.8 to 1.0 Ir adjustability in


Range Nominal Impulse GoPact125 breaker
Current Current

GoPact200 200A 2400A


● 0.7 to 1.0 Ir adjustability in
GoPact250 250A 3000A
GoPact200 to GoPact800 breakers
GoPact400 400A 4800A

GoPact800 800A 6400A ● Time delay and magnetic protection


Ir = 0.7 to 1x In adjustability not available in TMD
Ii = 12x In

● Adjustability is provided to protect


the load → Cross section of the
In = Rated Current cable should be in accordance with
Ii = Rated Instantaneous the nominal current
short circuit Current

Ir adjustment dial
Number of Poles and Detection
Ir = Rated Overload Setting Current
Confidential Property of Schneider Electric | Page 38

Internal
Electronic Tripping Unit (ETU) Setting | GoPact800 (1/2)
In ETU 2.4, 2.4 refers to 2 levels of protection (LS or LI) and availability only on Frame 4 (Go800)
Offer LSIN safety characteristics i.e. Overload (L), Short circuit (S), Instantaneous (I) and Overload protection in Neutral (N)

Default setting will


be all levers in max
/ ON condition

1 2 3 4 5 6 7 8

ON / OFF Rated current ON / OFF Time Delay with Instantaneous or Ii or Isd ON / OFF Short ON / OFF
Overload (Ir) adjustability Thermal 4 curve settings Short Circuit trip adjustability time protection Neutral
protection from 0,25x to Memory (INST / STS) Mode Protection
1.0x

All values from 0.25 to Memorizes the 3s @6Ir Above 1.2x of STS All values from 1.5 to 8 I2t = OFF (constant In ON state, for 4P
1 can be covered in previous state of 10s @6Ir setting, INST will (for 800A) / 10 (for time curve at 150ms) breaker, neutral fully
0.05 intervals using the breaker tripping or 3s @7.2Ir override STS 630A) / 12 (for 500A) protected at Ir
4 switches level of current and 10s @7.2Ir can be covered in 0.5 I2t = ON (inverse time
Ir=In[0.25 + ∑(W)] responds accordingly Ti = 40ms intervals using the 5 curve)
Tsd = 150ms switches
Confidential Property of Schneider Electric | Page 39 Isd=Ir[1.5 + ∑(X)]
Internal
Electronic Tripping Unit (ETU) Settings | GoPact800 (2/2)
Time Delay Setting (4) | INST / STS (5) | Ii / Isd adjustability (6) | Short time protection mode (7)

5 INST / STS & ON / OFF Short


4 Time Delay Setting for 6 Ii / Isd Adjustability
Overload Protection time protection mode
7
6Ir @ 10s Adjustability from 1.5x to 8x / 10x / 12x (Steps of 0.5)

DIP Switches

Basis Ir value change from 1.5 to


10 10 12x line shifts to the right 10 11 12 13 14 1.5 + σ𝟏𝟒
𝒌=𝟏𝟎
Trip Time (sec)

Trip Time (sec)


6Ir @ 3s
STS – I2t ON
7.2Ir @ 10s 500A 1.5 0.5 1 2 3 4 =12

0.15 STS – I2t OFF 630A 1.5 0.5 1 2 2 3 =10


3
0.04 INST
800A 1.5 0.5 1 1 2 2 =8
7.2Ir @ 3s

1 1.5
6 7.2 2 10
x Ir x Ir
Current Multiple Current Multiple

● Both INST and STS cannot be selected Maximum 22 combinations up to 12x


4 overload trip curves can be set
● In case of a short circuit fault that is 1.2x the
STS setting, an INST trip is executed
● I2t helps in delaying short circuit trip
Confidential Property of Schneider Electric | Page 40

Internal
Plug In Base | GoPact800 vs Other frames
Plug in base helps with fast replacement. In off condition, MCCB can be detached without removing power connections from base

● Plug in Base and conversion kit


references can be purchased
Plug In Base separately (E.g. spare breaker with
conversion kit)

● Ergonomically designed
GoPact800 Plug In base and
conversion kit to ensure easy
fitment and handling

Conversion Kit ● In built mechanical safety lock to


Handle / Gripper
prevent breaker plug out in ON
condition

● Mounting Screws for additional


Mounting 1/2 3 4 safety while fixing the Breaker in
Screw
Plug in Base (Safety provided via
Mounting Assembly interlock in GoPact800)

Confidential Property of Schneider Electric | Page 41

Internal
Rotary & Extended Rotary Handle How to Padlock?
Padlocking | Safety Interlock | Door Defeat
GoPact125 GoPact200 GoPact250 GoPact400 GoPact800

Direct
Rotary
Handle Safety Interlock Mechanism

Extended
Rotary
Handle


Door Defeat Mechanism
Clear ON / OFF / TRIP Button ● Ingress Protection: Extended (IP54), Direct (IP20)
● 3 padlocks can be used with diameter from 5 to 8mm ● Door Interlock in ON condition, with defeat facility
● Padlocking only possible with Direct / Extended ROM ● Door interlock in OFF condition with padlock feature
● Direct access to trip through TEST button (after door (Only in extended ROM)
defeat in extended version)

Confidential Property of Schneider Electric | Page 42

Internal
Annexures

Confidential Property of Schneider Electric | Page 46

Internal
GoPact | Technical Specifications (1/2)
EN / IEC 60947-2 → Certified by Dekra Product Material Compliance (Green Premium Label) CE Mark
Standards & IEC 60947-1 RoHS1 REACh2 PEP3 EoLI4
Certifications IEC 60947-5-1 (2011/65/UE)
(2015/863/UE)

Product Robustness Product Compactness (Fixed) Other Features


Line Load Reversibility ✓
Mechanical Life (No: of Operations): 30K Weight Weight Dimensions Dimensions Utilization Category
Frame
(15K for Go400 / 800, 25K for Go250) Size
(3P) (4P) (W x D x H) - 3P (W x D x H) - (60947-2) A
Kg Kg (mm) 4P (mm) Fixed, Plug in
Mounting Options
Base
Electrical Life (Operations @415VAC): 3K to 8K6 Horizontal,
Go125 0.7 0.9 75 x 60 x 130 100 x 60 x 130
Mounting Positions Vertical, Lying
Max temperature w/o derating: 55C (40C for Go125) > > Down
Max / Min operating temperature: -20C to +55C Go200 0.9 1.1 75 x 60 x 130 100 x 60 x 130 Test Button ✓
Max / Min Storage temperature: -35C to +85C Trip Unit
Interchangeability ×
Go250 1.9 2.4 105 x 90 x 165 140 x 90 x 165
Max altitude w/o derating: 2Km (Derating chart till 5Km)
DC Application ×
Motor Protection ×
Go400 3.5 4.5 120 x 105 x 205 160 x 105 x 205
Pollution Degree Conformance: III Marine Use ×
Go800 6.9 8.9 180 x 105 x 250 240 x 105 x 250
Cascading / Selectivity ×
Earth Leakage Protection ×
Capacitor Protection ×
Remote Operation
6 5K → 125A reference in Go125, 6K → 200A reference in Go200, 5K → Go400, 3K → Go800 (Motorized / Digital) ×
Confidential Property of Schneider Electric | Page 47 5 FTFM: Fixed Thermal Fixed Magnetic, ATFM: Adjustable Thermal Fixed Magnetic, LSIN: Long, Short, Instantaneous & Neutral
1 Restriction of Hazardous Substances (RoHS) 2 Registration, Evaluation, Authorization & Restriction ofInternal
Chemicals 3 Product Environmental Profile 4 End of Life Instructions
GoPact | Technical Specifications (2/2)
Altitude & Temperature Derating Charts

10KA1 15KA1 30KA1

36KA1 50KA1

25KA1 36KA1

50KA1 70KA1

25KA1 36KA1

Confidential Property of Schneider Electric | Page 48


1 Icu @415V Internal
GoPact | GoPact125 Frame

Breaker / Accessory Options Product Characteristics

Mechanical Life 30,000 cycles


3 Pole 4 Pole
125A – 5000 cycles
Electrical Life
Single Break Double Break 100A – 8000 cycles

100% (10KA &15KA)


Ics = % of Icu
TMD ETU 50% (30KA)

Max temp. without


Adjustable 40C
Fixed overload derating
overload
Rated Impulse
6
Withstand Voltage (KV)
Undervoltage
Shunt Trip (MX)1
Release (MN) # operations / minute 4

Auxiliary Contact (OF / SD) Weight (Kg) Fixed (3P / 4P) – 0.7 / 0.9

Dimensions (W*D*H) 3P – 75*60*130


mm 4P – 100*60*130
Direct / Extended Interphase
Rotary Handle barriers IP20 – Termination
Ingress Protection (IP)
IP40 – Panel Cutout Area
Terminal Shields
Spreaders
(Long / Short) Pole to pole distance
25
Steel Bare Cable
(Pitch in mm)
Rear Connectors
Connectors
Conversion Kit
Plug in Base
(Plug in base)

Offered Not Offered 1 MX only available in AC supply voltage version


Internal
GoPact | GoPact200 Frame

Breaker / Accessory Options Product Characteristics

3 Pole 4 Pole Upto 160A: 30K cycles


Mechanical Life
200A: 20K cycles

Single Break Double Break Upto 160A: 8000 cycles


Electrical Life
200A: 6000 cycles

TMD ETU Ics = % of Icu 100%

Adjustable Max temp. without


Fixed overload 55C
overload derating

Rated Impulse
8
Undervoltage Withstand Voltage (KV)
Shunt Trip (MX)
Release (MN)
# operations / minute 4
Auxiliary Contact (OF / SD)
Fixed (3P / 4P) – 0.9 / 1.1
Weight (Kg)
Plug in (3P / 4P) – 1.5 / 2.4

Direct / Extended Interphase Dimensions (W*D*H) 3P – 75*60*130


Rotary Handle barriers3 mm 4P – 100*60*130

Terminal Shields IP20 – Termination


Spreaders1 Ingress Protection (IP)
(Long / Short) IP40 – Panel Cutout Area

Steel Bare Cable Pole to pole distance


Rear Connectors 25
Connectors2 (Pitch in mm)
Conversion Kit
Plug in Base
(Plug in base)
1 Spreaders provided by default if 200A purchased for Go200. 2
Steel bare cable connectors not provided for 200A
3 Separate Interphase barrier reference provided in case 200A

Offered Not Offered breakers mounted on Plug In base are placed side by side
Internal
GoPact | GoPact250 Frame

Breaker / Accessory Options Product Characteristics

3 Pole 4 Pole Mechanical Life 25K cycles

Electrical Life 8000 cycles


Single Break Double Break
Ics = % of Icu 100%
TMD ETU
Max temp. without
55C
Adjustable
derating
Fixed overload
overload Rated Impulse
8
Withstand Voltage (KV)
Undervoltage
Shunt Trip (MX) # operations / minute 2
Release (MN)
Fixed (3P / 4P) – 1.9 / 2.4
Auxiliary Contact (OF / SD) Weight (Kg)
Plug in (3P / 4P) – 3.4 / 4.2

Dimensions (W*D*H) 3P – 105*90*165


mm 4P – 140*90*165
Direct / Extended Interphase
Rotary Handle barriers IP20 – Termination
Ingress Protection (IP)
IP40 – Panel Cutout Area
Terminal Shields
Spreaders
(Long / Short) Pole to pole distance
35
Steel Bare Cable (Pitch in mm)
Rear Connectors
Connectors
Conversion Kit
Plug in Base
(Plug in base)

Offered Not Offered


Internal
GoPact | GoPact400 Frame

Breaker / Accessory Options Product Characteristics

3 Pole 4 Pole Mechanical Life 15K cycles

Electrical Life 5000 cycles


Single Break Double Break
Ics = % of Icu 100%
TMD ETU
Max temp. without
55C
Adjustable
derating
Fixed overload
overload Rated Impulse
8
Withstand Voltage (KV)
Undervoltage
Shunt Trip (MX) # operations / minute 2
Release (MN)
Fixed (3P / 4P) – 3.5 / 4.5
Auxiliary Contact (OF / SD) Weight (Kg)
Plug in (3P / 4P) – 7 / 9

Dimensions (W*D*H) 3P – 120*105*205


mm 4P – 160*105*205
Direct / Extended Interphase
Rotary Handle barriers IP20 – Termination
Ingress Protection (IP)
IP40 – Panel Cutout Area
Terminal Shields
Spreaders
(Long / Short) Pole to pole distance
40
Steel Bare Cable (Pitch in mm)
Rear Connectors
Connectors
Conversion Kit
Plug in Base
(Plug in base)

Offered Not Offered


Internal
GoPact | GoPact800 Frame

Breaker / Accessory Options Product Characteristics

3 Pole 4 Pole Mechanical Life 15K cycles

Electrical Life 3000 cycles


Single Break Double Break
Ics = % of Icu 100%
TMD ETU
Max temp. without
55C
Adjustable derating
Fixed overload
overload
Rated Impulse
8
Withstand Voltage (KV)
Undervoltage
Shunt Trip (MX) # operations / minute 1
Release (MN)

Fixed (3P / 4P) – 6.9 / 8.9


Auxiliary Contact (OF / SD) Weight (Kg)
Plug in (3P / 4P) – 19 / 24

Dimensions (W*D*H) 3P – 180*105*250


mm 4P – 240*105*250
Direct / Extended Interphase
Rotary Handle barriers IP20 – Termination
Ingress Protection (IP)
Terminal Shields IP40 – Panel Cutout Area
Spreaders1
(Long / Short)
Pole to pole distance
60
Steel Bare Cable (Pitch in mm)
Rear Connectors
Connectors
Conversion Kit
Plug in Base
(Plug in base)

Offered Not Offered 1 Spreaders provided as separate references for 630A and 800A
Internal
Comparison | GoPact & EZC Complementary offers
creating a comprehensive
Medium Basic portfolio

GoPact EZC
UL Certification
Certification
Switchboard Certification × ✓ EZC → VERSATILE
Suited for project
Motor Protection MCCB (Magnetic Only)
opportunities covering
Advanced Marine Use Approval industrial, marine and
Protection
Earth Leakage Protection (Vigi Protection) × ✓ 1
building applications
Capacitor Protection
Breaker Poles: Available in 1 & 2 pole × ✓
Configuration
Options Rated Service Voltage 415V 415V, 440V, 550V
Fixed, Plug In Base, Din
Breaker Mounting Options Fixed, Plug In Base
Rail
Max Temperature without Derating 55C 50C
Physical & Mechanical Life (Nos) 15K to 30K 10K to 13K
Electrical
Electrical Life (Nos) 3K to 8K 3K to 5K
GoPact → ROBUST
Characteristics Suited for small building
Rated Current (A) 16A to 800A 15A to 630A applications (sold as loose
Breaking Capacity: Unique Ratings 70KA 7.5KA, 18KA component)
Thermal Adjustability ✓ ×
Electronic Tripping ✓ ×
1 ELCB available in EZC range upto 250A
Confidential Property of Schneider Electric | Page 54
Return
Internal
MCCB Offers Comparison
Parameter Compact NSX EasyPact CVS EasyPact EZC GoPact MCCB
Frame size Two (100-250A and 400-630A) Two (100-250A and 400-630A) Three (100A, 250A and 400- Five (125A, 200A, 250A, 400A,
630A) 800A)
Current ratings 16-630A 16-630A 15-600A 16-800A

Breaking capacity (Icu at 36kA to 200kA 25/36/50kA 7.5kA to 50kA 10kA to 70kA
415V AC)
Breaking capacity (Ics at 415V Ics = 100% x Icu Ics = 100% x Icu Ics = 50% x Icu Ics = 100% x Icu
AC) (except Go125 30kA, 50%)
Operational voltage Up to 690V AC 220/ 415/440V AC 220/ 415/440V AC 415V AC

Trip units 100-250A TMD/TMG/MA/Mic2/5/6.0 or E TMD/MA (all with adjustable TMD (all with fixed settings) TMD (Fixed on Go125 /
(all with adjustable settings) settings) Adjustable)

Trip units 400-630A Mic2/5/6.0 or E (all with TMD/MA/ETS2.3 (all with TMD/MA/ETS2.3 (all with fixed TMD/ETU 2.4 (LSIN)
adjustable settings) adjustable settings) settings)
Communication option Yes No No No

Versions Fixed, Plug-in, Withdrawable Fixed Fixed, Plug-in (upto 250A) Fixed & Plug-In (from Go200)

Accessory Rotary handle/Motor Rotary handle/earth-leakage Rotary handle/earth-leakage Rotary handle/plug-in


Mechanism/earth-
leakage/plug-in
Certification IEC, CE, CCC, UL508, Marine, IEC, CE, CCC, other local IEC, CE, CCC, UL508**, IEC
other local Marine

Internal
Internal
GoPact MTS
Robust | Simple
The high-quality, affordably priced answer to the competitive diffused market

Confidential Property of Schneider Electric

Internal
What is Changeover Switch?

SUPPLY 1

SUPPLY 2
`

CHANGEOVER SWITCH

Internal
Open Transition
(Break Before Make)

Types of
Transfer Closed Transition
Switches (Make Before Break)

Open Or Closed Transition


With Bypass Isolation Switch

Confidential Property of Schneider Electric


Internal
Applications
(Primary Source)

Source

Source
Transformer

(Back up Source)
DG

Motor starter
Conventional
Soft Starter
Motor
M

Load Load
Load
Switching of the power supply Switching between Bi-directional motor
Reliable Changeover from one load to another load Soft Starter & application
between either primary in order to ensure that they conventional starter Inversion of the Source
and backup sources both age at an equal rate connected to the phases supplying a motor
same motor load in order to modify the
direction of rotation

60

Internal
Offer Introduction | Switches, Spares & Accessories

Confidential Property of Schneider Electric | Page 61

Internal
Introducing GoPact MTS!
6 (GoPact 63 to 2000)
Frame Sizes

Pre-fitted accessories
No need to order separately

5.9 kApeak to 105 kApeak


Short Circuit Making Capacity

63A to 2000A
Rated Current

Simple Range (17 references only)

IEC Compliant
60947-3, 60947-6-1

Confidential Property of Schneider Electric | Page 62

Internal
GoPact | Offer Overview
FRAME 100A 200A 315A

CURRENT RATINGS 63 100 125 160 200 250 315

630A 1000A 2000A

400 630 630 800 1000 1250 2000


1600

Internal
GoPact | Accessories
Accessories are part of the product delivery

*Need to buy separately


Internal
Technical information

Confidential Property of Schneider Electric | Page 65

Internal
Main features to remember
Staggered Full safety Flip-able Handle Dual shaft position
Termination guaranteed

Easy access to Phase barriers, terminal Convenient manual Center & Side Handle
terminals for cable shrouds and Source operation operation
termination & separators is given as a (From 250A onwards)
inspection standard offering

Phase
Barrier Terminal
Shrouds

Source
Separator

Internal
Direct handle version – 63A & 100A

Internal
Self Interlocked Mechanism

Internal
Staggered terminals

69

Internal
Safety features

Phase Barriers: Terminal Shrouds:


Isolation between phases Finger proof terminals

Source Separator:
Isolation between
incoming sources

70

Internal
Dual shaft position

71

Internal
Flip-able handle

72

Internal
Auxiliary
Auxiliary contactKit kit

Auxiliary Kit : Click-fit and fully enclosed

Internal
Auxiliary
Universal Kit
mounting

Internal
Commercial References – Identification & Ordering Codes
Transfer Switch References (30 Nos) + Accessory References (49 Nos) = Total References (79 Nos) [Including Wave 1.1]

Confidential Property of Schneider Electric | Page 75

Internal
GoPact | Product Identification
Meaningful and easy to understand product coding

Commercial Reference: GM10D4N0634BEE

Confidential Property of Schneider Electric | Page 76

Internal
GoPact | MTS – Commercial References

17 MTS
References
(Opened in Wave 1)

13 more MTS
references to be
added in Wave 1.1

(Direct Handle vesions


for Frame 2 to Frame 6)

Confidential Property of Schneider Electric | Page 77

Internal
GoPact | Accessories & Spares– Commercial References (1/2)
Accessories
*
50
Accessory & Spare Part
References
Spare Parts

Confidential Property of Schneider Electric | Page 78

Internal
GoPact | Accessories & Spares– Commercial References (2/2)
Spare Parts
*

Confidential Property of Schneider Electric | Page 79

Internal
TransferPacT Automatic
The All-in-One transfer solution

Sales PPT

Confidential Property of Schneider Electric

Internal
Get to Know TSE

Confidential Property of Schneider Electric | Page 81

Internal
A day of John-the importance of power continuity
Elevator Subway

Bank Meeting Room

Healthcare Opera

Confidential Property of Schneider Electric | Page 82

Internal
TSE- the important part to keep power continuity

What did the day of John bring to us?

Critical loads must not be powered off

Critical loads must be powered by alternate source

How to transfer loads between sources?

Transfer Switching Equipment-TSE

Confidential Property of Schneider Electric | Page 83

Internal
Classification of TSE
IEC 60947-6-1:
equipment containing one or more switching devices and associated operating mechanism for
disconnecting load circuits from one supply and connecting to another supply

MTSE By physical RTSE By Signal ATSE Self Acting


operations

manually operated TSE remotely operated TSE automatic TSE


Feature:manual&Non electrical Feature:remote operated,friendly with Feature:self acting, including related
operated, cheap, slow in transfer system integration, complicate wiring devices for sensing and transfer.

Confidential Property of Schneider Electric | Page 84

Internal
Composition of ATSE

Control Unit Drive Breaking Cell

Confidential Property of Schneider Electric | Page 85

Internal
Composition of ATSE
Three Parts
Drive Breaking Cell
Control Unit

Confidential Property of Schneider Electric | Page 86

Internal
Composition of ATSE
Three Parts
Control Unit Breaking Cell
Drive

Confidential Property of Schneider Electric | Page 87

Internal
Composition of ATSE
Three Parts
Control Unit Drive
Breaking cell

Confidential Property of Schneider Electric | Page 88

Internal
TransferPacT Automatic
Product Structure

TransferPacT Automatic TransferPacT Active Automatic 2 frames, 2 types of control


panel (HMI)

32A-100A, 220V~440V,
2P, 3P, 4P available
32A-100A 32A-100A
80A-160A, 220V~440V
3P,4P

Utilization category AC-33B,


500ms transfer speed

Suitable for
U-U, U-G applications
80A-160A 80A-160A

Typical end distribution


ATSE

Rotary switch version LCD version

Confidential Property of Schneider Electric | Page 89

Internal
TransferPacT Automatic
Product Standards Compliance

Comply with the latest product standards and certification

CB CE CCC UKCA EAC


International European China Compulsory UK Declaration Europe Declaration
Electrician Directive certification
Certification

Internal
TransferPacT Automatic
Product Feature

COMPACT Ultra-FAST
design reduce 30% size, in transfer speed less than
fit in any panel 200 ms, maximized uptime

EASY Real ATSE


for installation and Non-derived, manufactured
commissioning according to TSE standard
IEC 60947-6-1

Confidential Property of Schneider Electric | Page 91

Internal
Product Value Prop
Sales presentation

Confidential Property of Schneider Electric | Page 92

Internal
Enhanced safety and power availability
TransferPacT Be the guardian for your operation

Enhanced Power Availability

Transfer in Vast Short circuit Best-in-class


500ms Application capabilities electromagnetic
AC33B protection

Confidential Property of Schneider Electric | Page 93

Internal
Simplest connectivity
Connectivity as a given, for operational efficiency

EcoStruxureTM Architecture

Apps,
Analytics &
Services
EcoStruxure Asset EcoStruxure EcoStruxure EcoStruxure
Advisor Power Advisor Resource Advisor Microgrid Advisor
End-to-end Cybersecurity

Cloud and/or On Premise

Edge
Control
EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure
Power Gateway Facillity Expert Power Monitoring Expert Power SCADA Operation Microgrid Operation

9 Series Pact Series PowerLogicTM SeT Series GalaxyTM ASCO

Connected
Products
Final level of protection World Class Breaker Power Quality, Uptime Comprehensive, robust Uninterruptable 3-Phase Automatic
In electrical distribution & Switches & Efficiency portfolio of power distribution and PowerFor IT and Industrial Transfer Switch
World Class Breaker motor control centers applications

& Switches

Confidential Property of Schneider Electric | Page 94

Internal
Key Values Efficiency

• Easy upgrade with hot swap function


Reduced size 2P 3P 4P
• One size for 2, 3, 4P, simple panel design.
• Built in controller
• Built in DPS and sensing wire, all in one transfer switch
• Compact design with reduced panel cost

• Plug and play function module can


be installed through life cycle

• Simplified and clear installation.


• no additional wiring andaccessories or components
needed.

Confidential Property of Schneider Electric | Page 95

Internal
TransferPacT Automatic segmentation and application
Segmentation

Data centers Transportations Buildings Healthcare

Confidential Property of Schneider Electric | Page 96

Internal
TransferPacT Active Automatic

A Embedded HMI: two types

B Controller Extension module


G H
C External HMI
A E F Auxiliary contacts for
D
D Transfer Switch positions

E Single line diagram

B F Slider for Manual transfer

G Isolator for dielectric test

H Power connection
C

Confidential Property of Schneider Electric | Page 97

Internal
TransferPacT Automatic – Product features
Controller

Controller

Major Characteristic Automatic Active Automatic

Loss of Voltage Yes Yes


Under/Over Voltage Yes Yes
Under/Over Frequency Yes Yes
Phase unbalance No Yes
Remote control Yes Yes
Loadshedding Yes Yes
Transfer Inhibit Yes Yes
Gen start/stop Yes Yes
Fire protection Yes Yes
Communication No Yes
Time delays Yes Yes
Event log No Yes

Confidential Property of Schneider Electric | Page 98

Internal
TransferPacT Automatic – Product features
Switch

ATSE

Major Characteristic Frame 100A Frame 160A


Ith 100A 160A
Poles 2,3,4 3,4
Rated Current(A) 32,40,50,63,80,100 80,100,125,160
Icw=5kA/100ms Icw=10kA/100ms
Icm=15kA Icm=20kA
Short circuit capabilities
Iq=50kA with MCCB Iq=70kA with MCCB
100kA with fuse 100kA with fuse
Insulating voltage Ui (V AC) 800V 800V
Impulse withstand voltage Uimp (V AC) 6kV 8kV
AC-33B (32A, 40A, 50A, 63A)
Utilization Category AC-33B
AC-32B (80A,100A)
Position Indication LED+Aux contact(Acc) LED+Aux contact(Acc)
Installation DIN Rail/Plate DIN Rail/Plate

Confidential Property of Schneider Electric | Page 99

Internal
TransferPacT Automatic Family – Frame 100A
Dimension H*W*D mm: 164*351*95
Weight: 5.6kG

• GB/T14048.11,IEC60947-6-1,EN 60947-6-1
• Rated current 32-100A, rated voltage 220-440V
• 2,3,4 pole
• Electrical and mechanical interlock, avoid simultaneous
closing on both source
• Utilization category AC-33B, AC-33iB (80.100A)
• Solenoid drive, transfer time less than 200ms
• Full short-circuit capabilities including Icw
• Suitable for isolation
• DIN Rail or plate installation

Confidential Property of Schneider Electric | Page 100

Internal
TransferPacT Automatic Family – Frame 160A
Dimension H*W*D mm: 164*351*95
Weight: 5.6kG

• GB/T14048.11,IEC60947-6-1,EN 60947-6-1
• Rated current 80-160A, rated voltage 220-440V
• 3,4 pole
• Electrical and mechanical interlock, avoid simultaneous
closing on both source
• Utilization category AC-33B
• Solenoid drive, transfer time less than 200ms
• Full short-circuit capabilities including Icw
• Suitable for isolation
• DIN Rail or plate installation

Confidential Property of Schneider Electric | Page 101

Internal
TransferPacT Automatic – Function modules

Two steps to upgrade Automatic to Active Automatic

1. unplug the rotary

2. insert the LCD

Upgrade complete

No power interruption and hot swap

For replacement, it’s the same

Confidential Property of Schneider Electric | Page 102

Internal
TransferPacT Automatic – Function modules

Two items needed to have external view for Automatic


Active Automatic

1. external HMI

2. connecting cable

Exact function with embedded HMI, higher priority.

No external power supply needed

External HMI Cable

Confidential Property of Schneider Electric | Page 103

Internal
Internal

You might also like