0% found this document useful (0 votes)
30 views

Class 10 - Design of Footing 1

This document provides design calculations for a spread footing to support a wall. It includes: 1) Calculating the effective bearing pressure and determining the footing width is 6 feet based on the dead and live loads. 2) Checking the bearing pressure for strength and calculating the factored moment and shear. 3) Sizing the depth and reinforcement based on the shear strength and development length requirements. 4) Specifying #5 bars at 9.5 inches for shear reinforcement and 12 inches for temperature and shrinkage reinforcement.

Uploaded by

Md Wazkuruni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views

Class 10 - Design of Footing 1

This document provides design calculations for a spread footing to support a wall. It includes: 1) Calculating the effective bearing pressure and determining the footing width is 6 feet based on the dead and live loads. 2) Checking the bearing pressure for strength and calculating the factored moment and shear. 3) Sizing the depth and reinforcement based on the shear strength and development length requirements. 4) Specifying #5 bars at 9.5 inches for shear reinforcement and 12 inches for temperature and shrinkage reinforcement.

Uploaded by

Md Wazkuruni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

12/11/2020

Design of Footings-1
Chap-16 (14th ed.); Chap-15 (15th ed.)

Prof. Dr. Md. Nazrul Islam


Department of Civil Engineering
Dhaka University of Engineering & Technology
(DUET), Gazipur.
Email: [email protected]
HP: 01716539548

FIGURE-16.1: Types of spread footing


2

1
12/11/2020

2
12/11/2020

3
12/11/2020

Given:
a = wall size =16 in.
DL = 14 k/ft, LL = 10 k/ft
qa = 4.5 k/sft (at 4 ft below grade)
f′c = 4 ksi, fy = 60 ksi.

Design a footing for this wall.

Solution:

Let, footing thickness (t)=12 in.


Selfweight = t/12*150 psf
= 150 psf
Weight of fill
= Depth of fill  unit weight of soil
= (4 - 1)  100 = 300 psf
Effective bearing pressure
qe = qa - (selfweight + weight of fill)
= 4.5*1000 – (150 + 300)
= 4050 psf.
Footing width (b) = (DL+LL)/qe
= (14+10)*1000/4050 = 5.93 ft. ≈ 6 ft. (say) 8

4
12/11/2020

Bearing pressure for strength design


qu = (1.2DL+1.6LL)/b
= (1.214 + 1.610)1000/6
= 5470 psf.

Factored moment at section 1-1


Mu = [qu{(b-a)/2}2]/2
= [5470{(6-16/12)/2}212]/2
= 178,900 in-lb/ft.

Shear at section 2-2 (let, d = 9 in.)


Vu = qu{(b-a)/2 - d}
= 5470{(6 - 16/12)/2 - 9/12}
= 8670 lb/ft. 9

Design shear strength

= 1138d lb/ft
= Vu = 8670

Or, d = 7.6 in.< dprovided = 12 – 3 (cover) – 0.5 (5/8)


= 8.7 in. ≈ 8.5 OK.

10

5
12/11/2020

Steel Area

Using Graph A.1b:

Use #5 bar @ 9.5 in. c/c.

11

12

6
12/11/2020

Development Length:

From Table-A.10

= (612 – 16)/2 - 3 = 25 in. OK

13

14

7
12/11/2020

Longitudinal Temp and Shrinkage Reinf.

= 0.26 in2/ft.
Use #5 bar @ 12 in. c/c.