CEMTEC Schmierliste - BWG-L
CEMTEC Schmierliste - BWG-L
Remark
For regreasing only use the prescribed brand of grease acc. to the lubrication instructions. If an other brand of grease is used, the grease in the bearing casing has to be removed and must be filled with the prescribed grease quantity for first filling.
1
Greases may only be mixed, if the saponification base as well as the basic oil types are equal. The viscosity of the basic oil should roughly also be equal.
2 Avoid a mixture of different lubricants ! In case of change to another lubricant type and / or manufacturer the compatibility is to be checked and actions against unintentional mixing are to be attempted if necessary.
3 In case of possible differences to this list because of special instructions by part manufacturers, gear unit and motor manufacturers these special documents must be considered
4 Check the grease filling of the labyrinth seal prior to the commissioning.
Relating Document
Document No. Revision Document Name
QTY. OF
EQUIP-MENT GREASE Delivery PRIMARY RELUBRICATION INTERVAL FOR FURTHER CHANGE
POS NO.
NO.
LUBRICATION DENOMINATION OF COMPONENT LUBRICATION TYPE QUANTITY QUANTITY [g]
CHANGE QUANTITY
RELUBRICATION
FIRST CHANGE INTERVAL
INTERVAL
POINTS SPECIFICATIONS Status
K2K-20 grease
01 2 Drive pulley, (bearing) grease gun filled 0,9 kg 0,07 kg 1800 h / every 3 month
as per DIN 51 825
02 2 Tension pulley, (bearing) (4) Bearings are maintenance-free; Labyrinth seal: Automatic lubricator
Main drive:
K2K-20 grease as per DIN
03 2 Motor (bearings) grease gun filled 30 g 17000 h
51 825