w1 Technical Description, Installation Manual and User Guide-1
w1 Technical Description, Installation Manual and User Guide-1
ULTRASONIC WATER
PE_QW1_V07
METER QALCOSONIC W1
TECHNICAL DESCRIPTION,
INSTALLATION MANUAL
AND USER GUIDE
TABLE OF CONTENTS
3 SAFETY INFORMATIO
3 1 APPLICATION FIELD
5 2 TECHNICAL DATA
6 2.1 DISPLAY (LCD)
6 2.2 DATA RECORDING AND STORAGE
7 2.3 ALARMS
7 2.4 EXTERNAL COMMUNICATION MODULES AND INTERFACES
8 2.5 PULSE OUTPUTS IN TEST MODE
8 2.6 POWER SUPPLY
8 2.7 MECHANICAL DATA
8 2.8 OPERATION CONDITIONS
8 3 OPERATING PRINCIPLE
9 4 MARKING AND SEALING
9 4.1 MARKING
9 4.2 SEALING
9 5 INSTALATTION
9 5.1 GENERAL REQUIREMENTS
9 5.2 CHECKING CONFIGURATION OF THE METER
10 5.3 MOUNTING
10 5.4 CHECKING OF INSTALLATION AND PARAMETER SETTING
10 6 OPERATION
10 6.1 DISPLAY FUNCTIONS
11 6.2 MENU STRUCTURE
12 6.3 VIEWING THE READINGS IN NORMAL MODE (USER MENU)
13 6.4 VIEWING THE READINGS IN VERIFICATION (TEST) MODE
13 6.5 VOLUME READINGS IN VERIFICATION MODE
13 6.6 INFO (STATUS) CODES
14 6.7 VERIFICATION (TEST) MODE CONTROL
14 6.8 ENDING OF VERIFICATION MODE
14 7 VERIFICATION
14 8 TRANSPORTATION AND STORAGE REQUIREMENTS
15 ANNEX A
15 A.1 DN 20:
16 A.2 DN 15:
17 ANNEX B
18 WARRANTY
EU DECLARATION OF CONFORMITY
AXIOMA Metering UAB, Veterinarų g. 52, Biruliškių k., Kauno raj., Lithuania, hereby declares that the water meter QALCOSONIC W1
conforms to the essential requirements of the following Directives:
2014/32/EU Directive 2014/32/EU of the 26 February 2014 on the harmonisation of electrical equipment designed for use wi-
European Parliament and of the Council the laws of the Member States relating to thin certain voltage limits.
of 26 February 2014 on the harmonisation electromagnetic compatibility (recast). 2014/53/EU Directive 2014/53/EU of the
of the laws of the Member States relating 2014/35/EU Directive 2014/35/EU of the European Parliament and of the Council
to the making available on the market of European Parliament and of the Council of 16 April 2014 on the harmonisation of
measuring instruments (recast). of 26 February 2014 on the harmonisation the laws of the Member States relating to
2014/30/EU Directive 2014/30/EU of the of the laws of the Member States relating the making available on the market of ra-
European Parliament and of the Council of to the making available on the market of dio equipment.
Kaunas, 31/01/2020
EU-Type Examination Certificate No: LT-1621-MI001-034
Quality System Certificate No: KS-1621-MP-003.18
The Notified Body:
Laboratory of Heat Equipment Research and Testing of the Lithuanian Energy Institute, Lithuania, Notified Body Number 1621.
Marking of electrical and into an unsorted municipal waste container trical and electronic equipment. For more
electronic equipment in together with other waste! detailed information about the recycling of
accordance with Article 14 This symbol on the product indicates that this product, please contact your local mu-
(2) of Directive 2012/19/EU it will not be treated as household waste. It nicipal office
It is prohibited to dispose a must be handed over to the applicable ta-
meter marked with this sign ke-back scheme for the recycling of elec-
SAFETY INFORMATION
Before beginning of installation works you • Only qualified technical personnel • Safety guarantees at installation and
must to read this document and follow its may install and maintain water me- service of meter is:
instructions. ters. Personnel must be familiar with - Hermetic fitting of primary flow sen-
The meter is battery-powered (3.6 V), appropriate technical documentati- sor into the pipeline,
risk factors during the meter installation on and general safety instructions. It
- Reliable fastening of water meter at
and service fluid flowing within flow sen- is necessary to follow general safety
installation.
sor with inner pressure up to 1,6 MPa and requirements during installation and
temperature up to 90°C. maintenance process.
WARNING!
Mounting of the sub-assemblies of water meter is permissible only after ensuring of absence of fluid and pressure in the pipeline.
CAUTION:
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
1 APPLICATION FIELD
Ultrasonic water meter QALCOSONIC W1 is designed for measurement of cold and hot water consumption.
The meter corresponds to essential requirements Annexes I and MI 001. The of European Standards EN ISO 4064
requirements of the Technical Regulation meter complies with the requirements and requirements of OIML R49-1.
CLIMATIC ENVIRONMENTAL Temperature range: from -15°C to +70°C Mechanical environment class: M1
CONDITIONS: Humidity: condensing Electromagnetic environment class: E2
axiomametering.com 3
ORDERING CODE COMBINATION OF THE METER *:
Type
axiomametering.com 4
2 TECHNICAL DATA
Ratio of the permanent flow rate to the lower limit of the flow-rate (selectable by the user):
Q3/Q1 = 250 , Q3/Q1 = 315, Q3/Q1 = 400, Q3/Q1 = 800
axiomametering.com 5
WORKING TEMPERATURE RANGE:
The maximum permissible error (MPE) on volumes delivered at flow rate between the transitional flow rate Q2 (included) and
the overload flow rate Q4 (included) is:
• When water temperature ≤ +30 °C +_ 2%
• When water temperature > +30 °C +_3%
The maximum permissible error (MPE) on volumes delivered at flow rate between the minimum flow rate Q1 (included) and the
transitional flow rate Q2 (excluded) for water having any temperature is: +
_ 5%
Lower line with 5-digits for displaying current flow rate in m3/h and special symbols for displaying operation modes. In the
case of battery discharge, all integral readings and archive data shall be saved for at least 16 years and can be accessed by
connecting a power battery in the operating condition.
THE FOLLOWING PARAMETERS OF EACH HOUR, DAY, AND MONTH ARE ACCUMULATED IN THE MEMORY OF THE METER:
axiomametering.com 6
DATA LOGGER CAPACITY:
• Up to 1480 hours for hourly records.
• Up to 1130 days for daily records.
• Up to 36 last months for monthly records.
Archive data storage time not less than 36 months. Storage time of measured integrated parameters even if device is disconnec-
ted from power supply is not less than 16 years.
2.3 ALARMS
Qalcosonic W1 meter has integrated system that informs about certain alarms. Several of them are critical and being
transmitted immediately. Other alarms or events are logged in status byte and transmitted within data telegrams.
All these critical errors are also shown in status byte. It also might show indications of empty pipe, communication credits, battery
lifetime and other.
AVAILABLE COMMUNICATION MODULES FOR DATA TRANSMISSION (ONLY ONE OPTION MIGHT BE SELECTED WHEN
PLACING THE ORDER):
• RF 868 MHz
• RF 433 MHz
• RF 915 MHz
• RF 920,5 MHz
• NB-IoT (frequency bands B1, B3, B5, B8, B20, B28)
All communication interfaces are intend- credit system is implemented into the is summed up. If the limit is expired, the
ed for data reading and meter parametri- meter. Time of communication through interface is blocked and the new time
sation. The meter is produced for being additional interfaces is automatically lim- limit of communications will start only af-
powered only from the internal battery. In ited to save the battery (up to 20 minutes ter the change of the hour (16 seconds for
order to save the battery, communication per month). Unused communication limit each next hour).
axiomametering.com 7
2.5 PULSE OUTPUTS IN TEST MODE
Pulse values are available only in Test Mode and it depends on the nominal flow rate Q3. It is specified in the table below:
3 OPERATING PRINCIPLE
Flow measuring principle is based on section many times and the flow down- functions. From the results of time differ-
ultrasonic measurement method. Ultra- stream between the ultrasonic sensors ence the flow rate is calculated and indi-
sonic signal moves along the measuring have to perform transmitter and receiver cated in display.
WATER METER PERFORMS ALL NECESSARY MEASUREMENT AND DATA STORAGE FUNCTIONS.
BELOW ARE THE MOST IMPORTANT:
• High stability in measuring water volume and detection characteristics of overload
• Calculation of the maximum values and their storage in archive
• Storage of necessary data for reports on set day yearly and monthly
• Archive data storage time 36 months
• Detection of faults
• Displaying values of parameters (optional) and displaying info codes
• Verification and service functions
axiomametering.com 8
4 MARKING AND SEALING
4.1 MARKING
There is following information on the front facture and serial number, permanent flow witch the meter shall be replaced, software
panel of the calculator of the meter: EC- rate Q3 and ratio R (Q3/Q1), temperature version number, IP code, communication
type examination certificate number, man- class, maximum admissible working pres- interface NB-IoT (if installed on the meter).
ufacturer’s trade mark, distributor logo (if sure (MAP), pressure loss class, installation
applicable), type of meter, year of manu- sensitivity class of the meter, latest date by
4.2 SEALING
The meter casing is imperceptibly closed. not apply if the upper cover is opened or body is activated and error code appears
Any unautorized opening of the housing connection between upper cover and the on the meter display.
is impossible without damaging. Addi- housing is damaged. For sealing of meter after installation, there
tional manufacturer protection is not ap- When the upper sealed cover is opened, are provided holes in the meter body (See
plied. The manufacturers warranty does the safety button that installed in the meter Annex B).
5 INSTALATTION
5.1 GENERAL REQUIREMENTS
PRIOR TO INSTALLING THE METER, IT IS NECESSARY:
• to check the complete set of the meter with that specified in the technical documentation.
• to check for any visible mechanical defects.
• to check the configuration of the meter and to change it if necessary.
The meters may only be installed by qualified specialists in accordance with the requirements of this document and the meter instal-
lation design.
NOTE. The transportation mode will turn off automatically (the possibility to change configuration parameters will be turned off) when
the meter starts operation and the volume integrator has accumulated more than 10 litres.
axiomametering.com 9
5.3 MOUNTING
The temperature of the working environ- The straight pipelines in upstream and In order to avoid stresses in the pipelines,
ment should not be higher than 70°C. downstream the meter is not necessary the distance between the meter con-
No special requirements are established (Qalcosonic W1 flow profile sensitivity nection points in the meter installation
for the free space around the meter. It class is U0 D0). place shall correspond to the total length
is important that nearby installations or It is recommended to install meters in of meter with regard to the thickness of
structures do not rest against the hous- pipelines as far as possible from pumps, gaskets.
ing of the meter and do not interfere partitions, and elbows. It is recommended to select meter instal-
with reading the data from the display. Water meters may be in all position (either lation place as far as possible from po-
The meter should be installed at a safe horizontally, vertically or inclined). tential sources of vibration (for example,
distance from other devices emitting Mandatory condition: in the operating pumps).
heat or strong electromagnetic field (in mode, the pipe must have a pressure of The gaskets must match with the pipe
order to prevent disturbance of its work- not less than 30 kPa and the pipe must be diameter. During the installation, gasket
ing environment conditions). fully filled with water. must be exactly centered with the center
Sizes and mounting dimensions of meter Direction of the arrow on the meter must of the pipe cross-section to avoid sticking
are provided in Annex A. match with the flow direction in pipeline. out gaskets inside the pipe.
6 OPERATION
6.1 DISPLAY FUNCTIONS
WATER METER IS EQUIPPED WITH 2-LINE LCD (LIQUID CRYSTAL DISPLAY):
Upper line with 9-digits for displaying measured volume of water.
Lower line with 5-digits for displaying current flow rate and special symbols for displaying operation modes.
Symbol Description
flow is flowing forward
Leakage
flow is flowing
Radio transmitter is active
backwards*
Error symbol is shown when there is a significant meter operation error. For the info code, see the LCD menu item 1.7 in
paragraph 6.2.
axiomametering.com 10
6.2 MENU STRUCTURE
Menu structure in normal mode is presented in Fig. 6.1.
Meter menu stages switches automatically. Individual stages, except total volume and info status code, could be disabled during instal-
lation. Error code is displayed only when an error occurs during meter operation. In normal mode this stage is skipped.
Fig. 6.1 Menu structure in normal mode
TEMPERATURE 2S
DATE 2S
TIME 2S
ERROR CODE 2S
SEGMENT TEST 2S
ID NUMBER 2S
CONTROL NUMBER 2S
axiomametering.com 11
6.3 VIEWING THE READINGS IN NORMAL MODE (USER MENU)
REMARK: here the full list of shown parameters is represented. For the specific meter it can be reduced.
2018 02 25
1.9 Segment test Changes each 1 second
INFO CODE 2S
Total volume
Flow rate
124 000 773 Updated every 10 seconds.
0 - Normal operation
1 - Reconfiguration warning
nXXX 2 - No consumption
4 - Damage of meter housing
8 - Calculator’s hardware failure detected
0 - Normal operation
1 - Leakage
0 - Normal operation
XXnX 4 - Hardware failure detected
8 - Hardware failure detected
0 - Normal operation
axiomametering.com 13
Active info codes are added, if there is detected more than one error. Then the summary indicated info code will be as follows:
Volume pulse values (via optical interface) in verification mode „TEST“ are presented in the table below.
VOLUME
PERMANENT FLOW RATE Q3, M3/H
PULSE VALUE, L/IMP
1,6 0,3
2,5 0,3
4 0,3
Using an optical head and PC with W1 special holder and opening the program mode is activated, meter readings are
TOOL software the meter verification start up window, PC port number (to displayed with resolution of 1 ml. Optical
mode (TEST) can be activated. wich optical head is connected) is en- pulse output of meter might be used or
Optical head should be connected to tered in the field „Com Port“. Click „Wake volume indications could be read direct-
the computer USB interface. After plac- up meter“ button, then click the „Enter ly from LCD.
ing optical head on the meter with the test mode“ button. When the meter TEST
7 VERIFICATION
Metrological control of meter parameters is performed according to requirements defined in EN ISO 4064-1.
• Storage and transportation temperature: from -25°C to 70°C (drained flow part)
• Humidity: not more than 93%
axiomametering.com 14
ANNEX A
Sizes and dimensions of water meter QALCOSONIC W1
A.1 DN 20:
MODEL L, MM
axiomametering.com 15
ANNEX A
Sizes and dimensions of water meter QALCOSONIC W1
A.2 DN 15:
MODEL L, MM
DN15 L80 80
DN15 L105 105
DN15 L110 110
DN15 L165 165
DN15 L170 170
axiomametering.com 16
ANNEX B
Example of sealing water meter after installation.
axiomametering.com 17
WARRANTY
Manufacturer gives warranty that meter parameters will meet the technical requirements, listed in the paragraph 2 of this document, if
transportation, storage and operation conditions will be followed.
Warranty period is 6 years from manufacturing date, with additional possibility to extend it for additional charge.
MANUFACTURER’S ADDRESS:
UAB “Axioma Metering”, Veterinarų g. 52, Biruliškių k., Kauno raj., Lithuania
tel. +370 37 360234, fax. +370 37 360358.
axiomametering.com 18