QALCOSONIC W1

AXIOMA METERING UAB

ULTRASONIC WATER
PE_QW1_V07

METER QALCOSONIC W1
TECHNICAL DESCRIPTION,
INSTALLATION MANUAL
AND USER GUIDE
TABLE OF CONTENTS

3 SAFETY INFORMATIO
3 1 APPLICATION FIELD
5 2 TECHNICAL DATA
6 2.1 DISPLAY (LCD)
6 2.2 DATA RECORDING AND STORAGE
7 2.3 ALARMS
7 2.4 EXTERNAL COMMUNICATION MODULES AND INTERFACES
8 2.5 PULSE OUTPUTS IN TEST MODE
8 2.6 POWER SUPPLY
8 2.7 MECHANICAL DATA
8 2.8 OPERATION CONDITIONS
8 3 OPERATING PRINCIPLE
9 4 MARKING AND SEALING
9 4.1 MARKING
9 4.2 SEALING
9 5 INSTALATTION
9 5.1 GENERAL REQUIREMENTS
9 5.2 CHECKING CONFIGURATION OF THE METER
10 5.3 MOUNTING
10 5.4 CHECKING OF INSTALLATION AND PARAMETER SETTING
10 6 OPERATION
10 6.1 DISPLAY FUNCTIONS
11 6.2 MENU STRUCTURE
12 6.3 VIEWING THE READINGS IN NORMAL MODE (USER MENU)
13 6.4 VIEWING THE READINGS IN VERIFICATION (TEST) MODE
13 6.5 VOLUME READINGS IN VERIFICATION MODE
13 6.6 INFO (STATUS) CODES
14 6.7 VERIFICATION (TEST) MODE CONTROL
14 6.8 ENDING OF VERIFICATION MODE
14 7 VERIFICATION
14 8 TRANSPORTATION AND STORAGE REQUIREMENTS
15 ANNEX A
15 A.1 DN 20:
16 A.2 DN 15:
17 ANNEX B
18 WARRANTY
EU DECLARATION OF CONFORMITY
AXIOMA Metering UAB, Veterinarų g. 52, Biruliškių k., Kauno raj., Lithuania, hereby declares that the water meter QALCOSONIC W1
conforms to the essential requirements of the following Directives:

2014/32/EU Directive 2014/32/EU of the 26 February 2014 on the harmonisation of electrical equipment designed for use wi-
European Parliament and of the Council the laws of the Member States relating to thin certain voltage limits.
of 26 February 2014 on the harmonisation electromagnetic compatibility (recast). 2014/53/EU Directive 2014/53/EU of the
of the laws of the Member States relating 2014/35/EU Directive 2014/35/EU of the European Parliament and of the Council
to the making available on the market of European Parliament and of the Council of 16 April 2014 on the harmonisation of
measuring instruments (recast). of 26 February 2014 on the harmonisation the laws of the Member States relating to
2014/30/EU Directive 2014/30/EU of the of the laws of the Member States relating the making available on the market of ra-
European Parliament and of the Council of to the making available on the market of dio equipment.

Kaunas, 31/01/2020
EU-Type Examination Certificate No: LT-1621-MI001-034
Quality System Certificate No: KS-1621-MP-003.18
The Notified Body:
Laboratory of Heat Equipment Research and Testing of the Lithuanian Energy Institute, Lithuania, Notified Body Number 1621.

For EU Customers only - WEEE Marking

Marking of electrical and into an unsorted municipal waste container trical and electronic equipment. For more
electronic equipment in together with other waste! detailed information about the recycling of
accordance with Article 14 This symbol on the product indicates that this product, please contact your local mu-
(2) of Directive 2012/19/EU it will not be treated as household waste. It nicipal office
It is prohibited to dispose a must be handed over to the applicable ta-
meter marked with this sign ke-back scheme for the recycling of elec-

SAFETY INFORMATION
Before beginning of installation works you • Only qualified technical personnel • Safety guarantees at installation and
must to read this document and follow its may install and maintain water me- service of meter is:
instructions. ters. Personnel must be familiar with - Hermetic fitting of primary flow sen-
The meter is battery-powered (3.6 V), appropriate technical documentati- sor into the pipeline,
risk factors during the meter installation on and general safety instructions. It
- Reliable fastening of water meter at
and service fluid flowing within flow sen- is necessary to follow general safety
installation.
sor with inner pressure up to 1,6 MPa and requirements during installation and
temperature up to 90°C. maintenance process.

WARNING!
Mounting of the sub-assemblies of water meter is permissible only after ensuring of absence of fluid and pressure in the pipeline.
CAUTION:
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

• The meter can be used at ambient • Storage and transportation temperatu-


temperature: -15°C ... +70°C re: -25°C ... +70°C (drained flow part)

1 APPLICATION FIELD
Ultrasonic water meter QALCOSONIC W1 is designed for measurement of cold and hot water consumption.

The meter corresponds to essential requirements Annexes I and MI 001. The of European Standards EN ISO 4064
requirements of the Technical Regulation meter complies with the requirements and requirements of OIML R49-1.

CLIMATIC ENVIRONMENTAL Temperature range: from -15°C to +70°C Mechanical environment class: M1
CONDITIONS: Humidity: condensing Electromagnetic environment class: E2

axiomametering.com 3
ORDERING CODE COMBINATION OF THE METER *:

Meter QALCOSONIC W1 QW1 _ _ _ _ _ _

Type

THE RATIO R (Q3/Q1): CODE


250 1
315 2
400 3
800 4

PERMANENT FLOW OVERALL END CODE


RATE Q3, M3/H LENGTH L, MM CONNECTIONS
1,6 80 G ¾ 11
1,6 105 G¾ 12
1,6 110 G¾ 13
1,6 165 G¾ 14
1,6 170 G¾ 15
2,5 80 G¾ 21
2,5 105 G¾ 22
2,5 110 G¾ 23
2,5 165 G¾ 24
2,5 170 G¾ 25
2,5 105 G1 31
2,5 110 G1 32
2,5 130 G1 33
2,5 165 G1 34
2,5 190 G1 35
4 105 G1 41
4 110 G1 42
4 130 G1 43
4 165 G1 44
4 190 G1 45

COMMUNICATION INTERFACE TYPE: CODE


RF 868 MHz 0
RF 433 MHz 1
RF 915 MHz 2
RF 920,5 MHz 3
NB - IoT 4

COMMUNICATION PROTOCOL: CODE


S1 1x
T1 2x
C1 3x
LORA WAN X1
SIGFOX X2

EXTRA COMMUNICATION INTERFACE: CODE


NONE 0

TEMPERATURE CLASS: CODE


Temperature class T 30 1
Temperature class T 30/90 2
Temperature class T 90 3
Temperature class T 50 4

axiomametering.com 4
2 TECHNICAL DATA
Ratio of the permanent flow rate to the lower limit of the flow-rate (selectable by the user):
Q3/Q1 = 250 , Q3/Q1 = 315, Q3/Q1 = 400, Q3/Q1 = 800

The technical data of the meter are provided in Table 1.1.


1.1. Table

PERMANENT JOINING PRESSURE


OVERLOAD MINIMUM TRANSITIONAL THRESHOLD OVERALL
FLOW RATE RATIO R TO THE LOSS
FLOW RATE FLOW RATE FLOW RATE VALUE, LENGTH L,
Q3/Q1 PIPELINE CLASS ΔP
Q3, M3/H Q4, M3/H Q1, M3/H Q2, M3/H M3/H MM
(THREAD – G) (BAR X 100)
1,6 250 2 0,0064 0,010 0,001 G ¾ 80 Δp 25
1,6 250 2 0,0064 0,010 0,001 G¾ 105 Δp 25
1,6 250 2 0,0064 0,010 0,001 G¾ 110 Δp 25
1,6 250 2 0,0064 0,010 0,001 G¾ 165 Δp 25
1,6 250 2 0,0064 0,010 0,001 G¾ 170 Δp 25
1,6 315 2 0,005 0,008 0,001 G ¾ 80 Δp 25
1,6 315 2 0,005 0,008 0,001 G¾ 105 Δp 25
1,6 315 2 0,005 0,008 0,001 G¾ 110 Δp 25
1,6 315 2 0,005 0,008 0,001 G¾ 165 Δp 25
1,6 315 2 0,005 0,008 0,001 G¾ 170 Δp 25
1,6 400 2 0,004 0,0064 0,001 G ¾ 80 Δp 25
1,6 400 2 0,004 0,0064 0,001 G¾ 105 Δp 25
1,6 400 2 0,004 0,0064 0,001 G¾ 110 Δp 25
1,6 400 2 0,004 0,0064 0,001 G¾ 165 Δp 25
1,6 400 2 0,004 0,0064 0,001 G¾ 170 Δp 25
2,5 250 3,125 0,01 0,016 0,001 G¾ 80 Δp 40
2,5 250 3,125 0,01 0,016 0,001 G¾ 105 Δp 40
2,5 250 3,125 0,01 0,016 0,001 G¾ 110 Δp 40
2,5 250 3,125 0,01 0,016 0,001 G¾ 165 Δp 40
2,5 250 3,125 0,01 0,016 0,001 G¾ 170 Δp 40
2,5 400 3,125 0,0062 0,010 0,001 G¾ 80 Δp 40
2,5 400 3,125 0,0062 0,010 0,001 G¾ 105 Δp 40
2,5 400 3,125 0,0062 0,010 0,001 G¾ 110 Δp 40
2,5 400 3,125 0,0062 0,010 0,001 G¾ 165 Δp 40
2,5 400 3,125 0,0062 0,010 0,001 G¾ 170 Δp 40
2,5 800 3,125 0,0031 0,005 0,001 G¾ 80 Δp 40
2,5 800 3,125 0,0031 0,005 0,001 G¾ 105 Δp 40
2,5 800 3,125 0,0031 0,005 0,001 G¾ 110 Δp 40
2,5 800 3,125 0,0031 0,005 0,001 G¾ 165 Δp 40
2,5 800 3,125 0,0031 0,005 0,001 G¾ 170 Δp 40
2,5 250 3,125 0,01 0,016 0,001 G1 105 Δp 25
2,5 250 3,125 0,01 0,016 0,001 G1 110 Δp 25
2,5 250 3,125 0,01 0,016 0,001 G1 130 Δp 25
2,5 250 3,125 0,01 0,016 0,001 G1 165 Δp 25
2,5 250 3,125 0,01 0,016 0,001 G1 190 Δp 25
2,5 400 3,125 0,0062 0,010 0,001 G1 105 Δp 25
2,5 400 3,125 0,0062 0,010 0,001 G1 110 Δp 25
2,5 400 3,125 0,0062 0,010 0,001 G1 130 Δp 25
2,5 400 3,125 0,0062 0,010 0,001 G1 165 Δp 25
2,5 400 3,125 0,0062 0,010 0,001 G1 190 Δp 25
4 250 5 0,016 0,025 0,002 G1 105 Δp 40
4 250 5 0,016 0,025 0,002 G1 110 Δp 40
4 250 5 0,016 0,025 0,002 G1 130 Δp 40
4 250 5 0,016 0,025 0,002 G1 165 Δp 40
4 250 5 0,016 0,025 0,002 G1 190 Δp 40
4 400 5 0,01 0,016 0,002 G1 105 Δp 40
4 400 5 0,01 0,016 0,002 G1 110 Δp 40
4 400 5 0,01 0,016 0,002 G1 130 Δp 40
4 400 5 0,01 0,016 0,002 G1 165 Δp 40
4 400 5 0,01 0,016 0,002 G1 190 Δp 40
4 800 5 0,005 0,008 0,002 G1 105 Δp 40
4 800 5 0,005 0,008 0,002 G1 110 Δp 40
4 800 5 0,005 0,008 0,002 G1 130 Δp 40
4 800 5 0,005 0,008 0,002 G1 165 Δp 40
4 800 5 0,005 0,008 0,002 G1 190 Δp 40

axiomametering.com 5
WORKING TEMPERATURE RANGE:

Meter temperature class T30 (0,1°C ... 30°C)


Meter temperature class T50 (0,1°C ... 50°C)
Meter temperature class T30/90 (30°C ... 90°C)
Meter temperature class T90 (0,1°C ... 90°C)

• Maximum admissible working pressure (pressure class) 16 bar (MAP16)


• Flow profile sensitivity class U0 D0
• Volume measurement units m3
• Resolution of a displaying device 0,001 m3
• Displaying range 999999,999 m3

The maximum permissible error (MPE) on volumes delivered at flow rate between the transitional flow rate Q2 (included) and
the overload flow rate Q4 (included) is:
• When water temperature ≤ +30 °C +_ 2%
• When water temperature > +30 °C +_3%

The maximum permissible error (MPE) on volumes delivered at flow rate between the minimum flow rate Q1 (included) and the
transitional flow rate Q2 (excluded) for water having any temperature is: +
_ 5%

If the flow-rate exceeds the maximum value Q4:


• When the flow-rate Q ≤ 1.2 ∙ Q4, the flow-rate measurement and calculations are continued.
• When the flow-rate Q > 1.2 ∙ Q4, calculations are performed using flow-rate value 1.2 ∙ Q4 and the info code
“Maximum allowed value of flow rate is exceeded” is recorded and the duration of that status is calculated.

2.1 DISPLAY (LCD)


THE DEVICE IS EQUIPPED WITH 2-LINES LCD (LIQUID CRYSTAL DISPLAY):
Upper line with 9-digits for displaying measured volume of water:
• Readings in normal mode: m3 ( three digits after decimal point).
• Readings in verification (TEST) mode: m3 (six digits after decimal point).

Lower line with 5-digits for displaying current flow rate in m3/h and special symbols for displaying operation modes. In the
case of battery discharge, all integral readings and archive data shall be saved for at least 16 years and can be accessed by
connecting a power battery in the operating condition.

2.2 DATA RECORDING AND STORAGE


In its memory, meter accumulates an archive of hourly, daily, and monthly measured parameters. Archive data can be read only by
remote data reading means, mentioned in 2.4 paragraph. Data archive values, which are also additionally showed on the display, are
specified in Paragraph 6.4.

THE FOLLOWING PARAMETERS OF EACH HOUR, DAY, AND MONTH ARE ACCUMULATED IN THE MEMORY OF THE METER:

1 Integral volume of water


2 Integral volume of water in the forward direction
3 Informational flow in the reverse direction
4 Maximum flow rate value and date
5 Info (Status) code
6 Total operating time
7 Operating time without error
8 Temperature

axiomametering.com 6
DATA LOGGER CAPACITY:
• Up to 1480 hours for hourly records.
• Up to 1130 days for daily records.
• Up to 36 last months for monthly records.

Archive data storage time not less than 36 months. Storage time of measured integrated parameters even if device is disconnec-
ted from power supply is not less than 16 years.

2.3 ALARMS
Qalcosonic W1 meter has integrated system that informs about certain alarms. Several of them are critical and being
transmitted immediately. Other alarms or events are logged in status byte and transmitted within data telegrams.

BY DEFAULT ENABLED CRITICAL ALARMS (SINCE 2020.06.01):


• Leakage (occurs when constant flow rate within 24 hours is more than 0.25/0.5/1% of Q3.
Disappears after 1 hour, if constant flow rate within that hour is less than configured value).
• Burst (occurs when constant flow rate within 60 minutes is more than 5/10/20% of Q3.
Disappears after 32 seconds, if constant flow rate within that period of time is less than configured value).
• Freeze (occurs when water temperature reaches about 2/3/4/5°C).
• Tamper (occurs when meter is opened or damaged).

BY DEFAULT DISABLED CRITICAL ALARMS:


• Negative flow (occurs when meter detects negative flow).
• No consumption (occurs when there was no water for the last 3/7/30 days).

All these critical errors are also shown in status byte. It also might show indications of empty pipe, communication credits, battery
lifetime and other.

2.4 EXTERNAL COMMUNICATION MODULES AND INTERFACES


Optical interface is integrated in Qal- in the test (verification) mode. It is activat- There is also NFC (Near Field Communi-
cosonic W1 meter by default. It is intend- ed by sending 1 second pulse sequence (5 cation) interface integrated by default. It is
ed for data reading, changing parameters minutes after the end of communication intended for data reading only.
of meter and for outputting optical pulses is automatically deactivated).

AVAILABLE COMMUNICATION MODULES FOR DATA TRANSMISSION (ONLY ONE OPTION MIGHT BE SELECTED WHEN
PLACING THE ORDER):
• RF 868 MHz
• RF 433 MHz
• RF 915 MHz
• RF 920,5 MHz
• NB-IoT (frequency bands B1, B3, B5, B8, B20, B28)

DATA IN QALCOSONIC W1 METER CAN BE TRANSMITTED USING THE FOLLOWING PROTOCOLS:


• wMBus T1
• wMBus S1
• wMBus C1
• SIGFOX
• LORA WAN
• CoAP

All communication interfaces are intend- credit system is implemented into the is summed up. If the limit is expired, the
ed for data reading and meter parametri- meter. Time of communication through interface is blocked and the new time
sation. The meter is produced for being additional interfaces is automatically lim- limit of communications will start only af-
powered only from the internal battery. In ited to save the battery (up to 20 minutes ter the change of the hour (16 seconds for
order to save the battery, communication per month). Unused communication limit each next hour).

axiomametering.com 7
2.5 PULSE OUTPUTS IN TEST MODE
Pulse values are available only in Test Mode and it depends on the nominal flow rate Q3. It is specified in the table below:

Permanent flow rate, Q3, m3/h 1,6 2,5 4,0

Pulse value, m3/imp 0,001 0,002 0,004

2.6 POWER SUPPLY


Meter is powered with one or two internal AA-size 3.6V lithium (Li-SOCl2) batteries with a service life of at least 16 years. Batteries
cannot be replaced. Accurate battery lifetime depends also on data transmission frequency.

2.7 MECHANICAL DATA


Dimensions of Qalcosonic W1 water meter are not greater than 75 mm x 77 mm x 190 mm (DN20, L190).
WEIGHT OF DIFFERENT SIZES OF QALCOSONIC W1 WATER METERS ARE SHOWN IN THE TABLE BELOW:

END CONNECTIONS (OVERALL LENGTH) WEIGHT OF METER, NOT MORE THAN, KG

G3/4“ (80 mm) 0,3


G3/4“ (105 mm) 0,3
G3/4“ (110 mm) 0,3
G3/4“ (165 mm) 0,3
G3/4“ (170 mm) 0,3
G1“ (105 mm) 0,4
G1“ (110 mm) 0,4
G1“ (130 mm) 0,4
G1“ (165 mm) 0,4
G1“ (190 mm) 0,4

2.8 OPERATION CONDITIONS


Enclosure protection class: IP68
OPERATING CONDITIONS: • relative humidity up to 100%, Installation: Indoor or outdoor
• ambient temperature form -15°C condensing Mechanical environment class: M1
to 70°C • atmospheric pressure 86 kPa to Electromagnetic environment class: E2
106.7 kPa

3 OPERATING PRINCIPLE
Flow measuring principle is based on section many times and the flow down- functions. From the results of time differ-
ultrasonic measurement method. Ultra- stream between the ultrasonic sensors ence the flow rate is calculated and indi-
sonic signal moves along the measuring have to perform transmitter and receiver cated in display.

WATER METER PERFORMS ALL NECESSARY MEASUREMENT AND DATA STORAGE FUNCTIONS.
BELOW ARE THE MOST IMPORTANT:
• High stability in measuring water volume and detection characteristics of overload
• Calculation of the maximum values and their storage in archive
• Storage of necessary data for reports on set day yearly and monthly
• Archive data storage time 36 months
• Detection of faults
• Displaying values of parameters (optional) and displaying info codes
• Verification and service functions

axiomametering.com 8
4 MARKING AND SEALING
4.1 MARKING
There is following information on the front facture and serial number, permanent flow witch the meter shall be replaced, software
panel of the calculator of the meter: EC- rate Q3 and ratio R (Q3/Q1), temperature version number, IP code, communication
type examination certificate number, man- class, maximum admissible working pres- interface NB-IoT (if installed on the meter).
ufacturer’s trade mark, distributor logo (if sure (MAP), pressure loss class, installation
applicable), type of meter, year of manu- sensitivity class of the meter, latest date by

THE FOLLOWING IS INDICATED ON THE HOUSING OF WATER METER:


• Type of connection (thread or relative diameter)
• Flow direction

4.2 SEALING
The meter casing is imperceptibly closed. not apply if the upper cover is opened or body is activated and error code appears
Any unautorized opening of the housing connection between upper cover and the on the meter display.
is impossible without damaging. Addi- housing is damaged. For sealing of meter after installation, there
tional manufacturer protection is not ap- When the upper sealed cover is opened, are provided holes in the meter body (See
plied. The manufacturers warranty does the safety button that installed in the meter Annex B).

5 INSTALATTION
5.1 GENERAL REQUIREMENTS
PRIOR TO INSTALLING THE METER, IT IS NECESSARY:
• to check the complete set of the meter with that specified in the technical documentation.
• to check for any visible mechanical defects.
• to check the configuration of the meter and to change it if necessary.

The meters may only be installed by qualified specialists in accordance with the requirements of this document and the meter instal-
lation design.

5.2 CHECKING CONFIGURATION OF THE METER


Prior to installing the meter, it must be verified whether its configuration complies with the requirements for the specific facility and it
must be changed if necessary.
THE FOLLOWING PARAMETERS SHALL BE VERIFIED (THE FACTORY SETTINGS FOR THE METER ARE THEIR STANDARD ONES):
• volume measurement units
• displayed volume resolution (point position)
• set day of year and month
• customer number
• internal clock time

NOTE. The transportation mode will turn off automatically (the possibility to change configuration parameters will be turned off) when
the meter starts operation and the volume integrator has accumulated more than 10 litres.

axiomametering.com 9
5.3 MOUNTING
The temperature of the working environ- The straight pipelines in upstream and In order to avoid stresses in the pipelines,
ment should not be higher than 70°C. downstream the meter is not necessary the distance between the meter con-
No special requirements are established (Qalcosonic W1 flow profile sensitivity nection points in the meter installation
for the free space around the meter. It class is U0 D0). place shall correspond to the total length
is important that nearby installations or It is recommended to install meters in of meter with regard to the thickness of
structures do not rest against the hous- pipelines as far as possible from pumps, gaskets.
ing of the meter and do not interfere partitions, and elbows. It is recommended to select meter instal-
with reading the data from the display. Water meters may be in all position (either lation place as far as possible from po-
The meter should be installed at a safe horizontally, vertically or inclined). tential sources of vibration (for example,
distance from other devices emitting Mandatory condition: in the operating pumps).
heat or strong electromagnetic field (in mode, the pipe must have a pressure of The gaskets must match with the pipe
order to prevent disturbance of its work- not less than 30 kPa and the pipe must be diameter. During the installation, gasket
ing environment conditions). fully filled with water. must be exactly centered with the center
Sizes and mounting dimensions of meter Direction of the arrow on the meter must of the pipe cross-section to avoid sticking
are provided in Annex A. match with the flow direction in pipeline. out gaskets inside the pipe.

5.4 CHECKING OF INSTALLATION AND PARAMETER SETTING


If meter is installed correctly, the display of the meter should display flow readings (when there is flow).
It is necessary to check whether the meter is installed in the correct direction or there is no air in the system.

6 OPERATION
6.1 DISPLAY FUNCTIONS
WATER METER IS EQUIPPED WITH 2-LINE LCD (LIQUID CRYSTAL DISPLAY):
Upper line with 9-digits for displaying measured volume of water.
Lower line with 5-digits for displaying current flow rate and special symbols for displaying operation modes.

FLOW ARROW MEANINGS: SPECIAL SYMBOLS ON LCD:

Symbol Description
flow is flowing forward
Leakage

flow is flowing
Radio transmitter is active
backwards*

arrow is not displayed flow does not flow Pipeline is empty

Pipe is cracked (Burst)


REMARK: for reverse flow, the meter shows backflow m3/h
and an error code is also sent, due to backflow.
Fault (Error)
The direct water volume summation record remains
unchanged (unless chosen differently).
Battery replacement time

Error symbol is shown when there is a significant meter operation error. For the info code, see the LCD menu item 1.7 in
paragraph 6.2.

axiomametering.com 10
6.2 MENU STRUCTURE
Menu structure in normal mode is presented in Fig. 6.1.
Meter menu stages switches automatically. Individual stages, except total volume and info status code, could be disabled during instal-
lation. Error code is displayed only when an error occurs during meter operation. In normal mode this stage is skipped.
Fig. 6.1 Menu structure in normal mode

TOTAL VOLUME FLOW RATE 10 S

FORWARD FLOW VOLUME 10 S

REVERSE FLOW VOLUME 10 S

TEMPERATURE 2S

DATE 2S

TIME 2S

ERROR CODE 2S

VOLUME ON SET DAY / DATE 10 S

SEGMENT TEST 2S

ID NUMBER 2S

CONTROL NUMBER 2S

axiomametering.com 11
6.3 VIEWING THE READINGS IN NORMAL MODE (USER MENU)
REMARK: here the full list of shown parameters is represented. For the specific meter it can be reduced.

ID PARAMETER VALUE (EXAMPLE) REMARKS

1.1 Total volume


Flow rate
100 771
1 331
1.2 Forward flow volume 100 771
1.3
Informational volume
of total reverse flow
3 771
1.4 Water temperature value

1.5 Date 2018 02 25


1.6 Real time 10 12
1.7 Info (error) code 10 12
100 771
Accumulated volume
1.8
on set day and date

2018 02 25
1.9 Segment test Changes each 1 second

1.10 User identification number 000000 134


1.11 Control number 8800
The indication of irrelevant parameters can be turned off. Also, parameters that are not relevant to the set meter configuration will not
be indicated.
The indication of parameters can be turned on or off by means of the configuration software „W1 TOOL“ through the optical interface
when installing the meter (if the meter is in the transportation mode).

6.4 VIEWING THE READINGS IN VERIFICATION (TEST) MODE


Menu structure in verification (test) mode is presented in the Fig 6.2.

HIGH - RESOLUTION VOLUME / FLOW RATE 10 S

INFO CODE 2S

Fig. 6.2 Menu structure in verification (test) mode

6.5 VOLUME READINGS IN VERIFICATION MODE


PARAMETER VALUE (EXAMPLE) REMARKS

Total volume
Flow rate
124 000 773 Updated every 10 seconds.

Flow rate value and

1 331 inscription „tESt“ changes every


second

Forward flow volume 124 000 773


6.6 INFO (STATUS) CODES
Operating status is encoded by a 4-digit code on LCD:

CODE NUMBER DESCRIPTION

0 - Normal operation
1 - Reconfiguration warning
nXXX 2 - No consumption
4 - Damage of meter housing
8 - Calculator’s hardware failure detected
0 - Normal operation
1 - Leakage

XnXX 2 - Pipe is cracked (Burst)


4 - Optical communication temporarily stopped
8 - Low battery (less than 12 months lifetime left)

0 - Normal operation
XXnX 4 - Hardware failure detected
8 - Hardware failure detected
0 - Normal operation

1 - No signal; the flow sensor is not filled with water


XXXn
2 - Reverse flow
4 - Flow rate is greater than 1,25∙Q4 (indicated q=1,25∙Q4)
8 - Freeze alert

axiomametering.com 13
Active info codes are added, if there is detected more than one error. Then the summary indicated info code will be as follows:

3 - corresponds errors 2 + 1 A - corresponds errors 8 + 2 D - corresponds errors 8 + 4 + 1


5 - corresponds errors 4 + 1 B - corresponds errors 8 + 2 + 1 E - corresponds errors 8 + 4 + 2
7 - corresponds errors 4 + 2 + 1 C - corresponds errors 8 + 4 F - corresponds errors 8 + 4 + 2 +1
9 - corresponds errors 8 + 1

6.7 VERIFICATION (TEST) MODE CONTROL


In verification (test) mode it is possible to achieve precise results within short measuring time.
In the test mode, the meter:

• indicates the increased resolution of flow values.


• forms volume pulses through the optical interface.

Volume pulse values (via optical interface) in verification mode „TEST“ are presented in the table below.

VOLUME
PERMANENT FLOW RATE Q3, M3/H
PULSE VALUE, L/IMP
1,6 0,3
2,5 0,3
4 0,3

Using an optical head and PC with W1 special holder and opening the program mode is activated, meter readings are
TOOL software the meter verification start up window, PC port number (to displayed with resolution of 1 ml. Optical
mode (TEST) can be activated. wich optical head is connected) is en- pulse output of meter might be used or
Optical head should be connected to tered in the field „Com Port“. Click „Wake volume indications could be read direct-
the computer USB interface. After plac- up meter“ button, then click the „Enter ly from LCD.
ing optical head on the meter with the test mode“ button. When the meter TEST

6.8 ENDING OF VERIFICATION MODE


Using an optical head and PC with W1 TOOL software the meter verification mode (TEST) is returned to the operating mode. After
opening the program startup window, click „Wake up meter“, then click „Enter user mode“. The meter returns to the normal mode.
Also, meter returns to its normal mode automatically in 24 hours after activation of TEST mode.

7 VERIFICATION
Metrological control of meter parameters is performed according to requirements defined in EN ISO 4064-1.

8 TRANSPORTATION AND STORAGE REQUIREMENTS


Packed meters may be transported in any type of covered vehicle. Equipment should be anchored reliably to avoid shock and possi-
bility to shift inside vehicle. Meters should be protected against mechanical damage and shock. No aggressive chemical substances
should be stored together because of corrosion hazard.

• Storage and transportation temperature: from -25°C to 70°C (drained flow part)
• Humidity: not more than 93%

axiomametering.com 14
ANNEX A
Sizes and dimensions of water meter QALCOSONIC W1

A.1 DN 20:

MODEL L, MM

DN20 L105 105


DN20 L110 110
DN20 L130 130
DN20 L165 165
DN20 L190 190

axiomametering.com 15
ANNEX A
Sizes and dimensions of water meter QALCOSONIC W1

A.2 DN 15:

MODEL L, MM

DN15 L80 80
DN15 L105 105
DN15 L110 110
DN15 L165 165
DN15 L170 170

axiomametering.com 16
ANNEX B
Example of sealing water meter after installation.

axiomametering.com 17
WARRANTY
Manufacturer gives warranty that meter parameters will meet the technical requirements, listed in the paragraph 2 of this document, if
transportation, storage and operation conditions will be followed.
Warranty period is 6 years from manufacturing date, with additional possibility to extend it for additional charge.

MANUFACTURER’S ADDRESS:

UAB “Axioma Metering”, Veterinarų g. 52, Biruliškių k., Kauno raj., Lithuania
tel. +370 37 360234, fax. +370 37 360358.

axiomametering.com 18