Lab Experiment On Buckling of Struts

The document describes measurements taken from three samples of a structural member under different loads. For each sample, the length, width, thickness, and moment of inertia are provided. Deflection readings were recorded at mid-span under loads of 30, 50, 70, 90, and 110 Newtons. Load-deflection graphs were plotted for each sample to determine the modulus of elasticity. Sample 1 had a modulus of 120, Sample 2 was 103.48, and Sample 3 was 140.

Uploaded by

Izz Amriee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

Lab Experiment On Buckling of Struts

The document describes measurements taken from three samples of a structural member under different loads. For each sample, the length, width, thickness, and moment of inertia are provided. Deflection readings were recorded at mid-span under loads of 30, 50, 70, 90, and 110 Newtons. Load-deflection graphs were plotted for each sample to determine the modulus of elasticity. Sample 1 had a modulus of 120, Sample 2 was 103.48, and Sample 3 was 140.

Uploaded by

Izz Amriee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Length of member = 60mm

Width of member = 24.80mm


Thickness of member = 3.10mm
Moment of inertia of member = 446400mm4
Dial gauge reading, 1 div = 0.01 mm

Mid-span Mid-span
Load, P (N) d/P (mm/N)
deflection, d (div) deflection, d (mm)

30 13 13 x 0.01 = 0.13 0.004


50 40 40 x 0.01 = 0.40 0.008
70 85 85 x 0.01 = 0.85 0.012
90 121 121 x 0.01 = 1.21 0.013
110 125 125 x 0.01 = 1.25 0.011

Mid-span Mid-span
Load, P (N) d/P (mm/N)
deflection, d (div) deflection, d (mm)

30 6 6 x 0.01 = 0.06 0.002


50 8 8 x 0.01 = 0.08 0.0016
70 8 8 x 0.01 = 0.08 0.0011
90 15 15 x 0.01 = 1.15 0.0128
110 15 15 x 0.01 = 1.15 0.0105

Mid-span Mid-span
Load, P (N) d/P (mm/N)
deflection, d (div) deflection, d (mm)

30 9 9 x 0.01 = 0.09 0.003


50 18 18 x 0.01 = 0.18 0.0036
70 47 47 x 0.01 = 0.47 0.0067
90 75 75 x 0.01 = 0.75 0.0083
110 116 116 x 0.01 = 1.16 0.0105
Sample 1
Sample 2
Sample 3
Graf for sample 1

1.4

1.2

1
Mid-span deflection

0.8

0.6

0.4

0.2

0
0.004 0.008 0.012 0.013 0.011

deflection/load

Graf for sample 2

1.4

1.2

1
Mid-span deflection

0.8

0.6

0.4

0.2

0
0.002 0.0016 0.0011 0.0128 0.0105

deflection/load
Graf for sample 3

1.4

1.2

1
Mid-span deflection

0.8

0.6

0.4

0.2

0
0.003 0.0036 0.0067 0.0083 0.0105

deflection/load

MG1 = 120

MG2 = 103.48

MG3 = 140