A. INTRODUCTION
Criterion 4, "Environmental and Dynamic Effects Design Bases," of Appendix A, "General Design
Criteria for Nuclear Power Plants," to 10 CFR Part 50, "Domestic Licensing of Production and Utilization
Facilities," requires, in part, that structures, systems, and components important to safety be designed to
accommodate the effects of and to be compatible with the environmental conditions associated with
normal operation, maintenance, testing, and postulated accidents. Criterion 19, "Control Room," requires
that a control room be provided from which actions can be taken to operate the nuclear power unit safely
under normal conditions and to maintain it in a safe condition under accident conditions.
Releases of hazardous chemicals can result in the control room becoming uninhabitable. This
regulatory guide describes assumptions acceptable to the NRC staff for use in assessing the habitability of
the control room during and after a postulated external release of hazardous chemicals from mobile or
stationary sources, offsite or onsite. This guide also provides guidance acceptable to the NRC staff for the
protection of control room operators against an accidental release of such hazardous chemicals, including
chlorine. Regulatory Guide 1.95, “Protection of Nuclear Power Plant Control Room Operators Against an
Accidental Chlorine Release,” provided guidance on storing chlorine onsite, described acceptable design
features and procedures for the protection of nuclear power plant control room operators against an
accidental onsite chlorine release, and outlined emergency procedures that need to be initiated in the event
of a chlorine release.
Regulatory guides are issued to describe and make available to the public such information as methods acceptable to the NRC staff for implementing specific parts of the
NRC’s regulations, techniques used by the staff in evaluating specific problems or postulated accidents, and data needed by the NRC staff in its review of applications
for permits and licenses. Regulatory guides are not substitutes for regulations, and compliance with them is not required. Methods and solutions different from those set
out in the guides will be acceptable if they provide a basis for the findings requisite to the issuance or continuance of a permit or license by the Commission.
This guide was issued after consideration of comments received from the public. Comments and suggestions for improvements in these guides are encouraged at all times,
and guides will be revised, as appropriate, to accommodate comments and to reflect new information or experience. Written comments may be submitted to the Rules
and Directives Branch, ADM, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.
Regulatory guides are issued in ten broad divisions: 1, Power Reactors; 2, Research and Test Reactors; 3, Fuels and Materials Facilities; 4, Environmental and Siting;
5, Materials and Plant Protection; 6, Products; 7, Transportation; 8, Occupational Health; 9, Antitrust and Financial Review; and 10, General.
Single copies of regulatory guides (which may be reproduced) may be obtained free of charge by writing the Distribution Services Section, U.S. Nuclear Regulatory
Commission, Washington, DC 20555-0001, or by fax to (301)415-2289, or by email to [email protected]. Electronic copies of this guide, along with other recently
issued guides, are available on the internet at NRC’s home page, <WWW.NRC.GOV>, in the Electronic Reading Room. This guide has accession number ML013100014.
This Revision 1 of Regulatory Guide 1.78 incorporates and withdraws Regulatory Guide
1.95 since many regulatory positions in these two guides are the same or similar. This revision also
updates certain regulatory positions based on more current knowledge of the subject. This guide
does not consider the explosion hazard of these chemicals, which is addressed separately in
Regulatory Guide 1.91, “Evaluations of Explosions Postulated To Occur on Transportation Routes
Near Nuclear Power Plants” (Ref. 1), nor does it address flammability hazards, which are
addressed separately in Regulatory Guide 1.189, “Fire Protection for Operating Nuclear Power
Plants” (Ref. 2).
The information collections contained in this regulatory guide are covered by the
requirements of 10 CFR Part 50, which were approved by the Office of Management and Budget,
approval number 3150-0011. If a means used to impose an information collection does not display
a currently valid OMB control number, the NRC may not conduct or sponsor, and a person is not
required to respond to, the information collection.
B. DISCUSSION
The control room of a nuclear power plant should be appropriately protected from
hazardous chemicals that may be discharged as a result of equipment failures, human errors, or
events and conditions outside the control of the nuclear power plant. Sources of hazardous
chemicals could be mobile or stationary and could include storage tanks, pipelines, fire-fighting
equipment, tank trucks, railroad cars, and barges.
This guide has been revised to provide guidance on control room habitability during a
postulated hazardous chemical release, including chlorine. The guide describes assumptions and
criteria for screening out release events that need not be considered in the evaluation of control
room habitability. The guide also provides guidance on performing detailed evaluations of control
room habitability and on screening criteria, including the distance between the release source and
the control room, the frequency of shipments (to calculate release frequency from a mobile
source), the quantity and duration of a release, toxicity of released chemicals, meteorological
conditions (for dispersion calculations), and the rate of air infiltration into the control room. The
guide covers both toxic and asphyxiating chemicals, but recognizes that the asphyxiating
chemicals should only be considered if their release results in displacement of a significant
fraction of the control room air. The Occupational Safety and Health Administration (OSHA)
provides guidance on what is considered an oxygen-deficient atmosphere.
This revision of Regulatory Guide 1.78 updates specifications of toxicity limits based on
more recent data (Regulatory Position 3), brings risk insights into the process, and makes the
guidance more performance-based. Consistent with risk-informed regulatory decision-making,
this revision encourages licensees to make greater use of risk insights in submitting applications
for plant-specific changes to the licensing basis, using the guidance provided in Regulatory Guide
1.174 (Ref. 3). At the same time, the revision continues to provide latitude to the licensees for the
use of traditional engineering approaches. Also, consistent with the intent of SECY-00-0191
(Ref. 4) on performance-based initiatives, this revision provides performance-based guidance
rather than traditional prescriptive guidance.
1.78-2
The June 1974 version of Regulatory Guide 1.78 specified a 2-minute exposure to given
concentration limits of certain toxic chemicals. The 2-minute exposure criterion was based on the
time a control room operator is expected to take to don a respirator and protective clothing. The
concentration limits were based on outdated and often unverifiable references. Further, only a
limited number of chemicals have the toxicity limits specified in the 1974 guide. The National
Institute for Occupational Safety and Health (NIOSH) has published updated toxicity limits for
many hazardous chemicals, based on the Immediately Dangerous to Life and Health (IDLH)
exposure level concept (Ref. 5). The IDLH value or limit, based on a 30-minute exposure level, is
defined as one that is likely to cause death or immediate or delayed permanent adverse health
effects if no protection is afforded within 30 minutes. The IDLH exposure limits were developed
for respirator selection for a large number of chemicals, including those covered in this regulatory
guide. The use of IDLH values as toxicity limits is considered appropriate since it provides an
adequate margin of safety as long as control room operators use protective measures within 2
minutes after the detection of hazardous chemicals; they therefore would not be subjected to
prolonged exposures at the IDLH concentration levels. Therefore, these limits are included in this
revision of Regulatory Guide 1.78.
Many of the regulatory positions in the original Regulatory Guides 1.78 and 1.95 are the
same or similar. This revision combines these two guides, thereby making the positions
applicable to all toxic chemicals, including chlorine, that should be considered in the control room
habitability evaluation. Combining the two guides eliminates certain duplication of efforts for
licensees in submitting their applications and streamlines the NRC staff review process.
C. REGULATORY POSITION
The following guidance is provided for evaluating the habitability of a nuclear power plant
control room during a postulated hazardous chemical release.
1. HAZARD SCREENING
Chemicals stored or situated at distances greater than 5 miles from the plant need not be
considered because, if a release occurs at such a distance, atmospheric dispersion will dilute and
disperse the incoming plume to such a degree that either toxic limits will never be reached or there
would be sufficient time for the control room operators to take appropriate action. In addition, the
probability of a plume remaining within a given sector for a long period of time is quite small.
1.78-3
If sources of hazardous chemicals such as those listed in Table 1 are known or projected to
be present within a 5-mile radius of the plant, and in quantities less than those shown in the table
of examples in Appendix A for a given toxicity limit and stable meteorological conditions, these
sources need not be considered in the evaluation of control room habitability. Appendix A to this
guide also contains a simplified procedure for adjusting the quantities given in the table to
appropriately account for the toxicity limit of a specific chemical, the meteorological conditions of
a particular site, and the air exchange rate of a control room. The calculations in Appendix A are
included as examples of the guidance.
Any hazardous chemical stored onsite within 0.3 miles of the control room in a quantity
greater than 100 pounds should be considered for control room habitability evaluation. Hazardous
chemicals should not be stored within the close proximity (generally within 330 feet or less) of a
control room or its fresh air inlets, including ventilation system intakes and locations of possible
infiltration such as penetrations. Small quantities for laboratory use, 20 pounds or less, are
exempt. The maximum allowable inventory in a single container stored at specified distances
beyond 330 feet from the control room or its fresh air inlet varies according to the distance and the
control room type.
If there are several chemical containers, only the failure of the largest container is normally
considered in the evaluation unless the containers are interconnected in such a manner that failure
of a single container could cause a release from several containers.
If hazardous chemicals such as those listed in Table 1 are known or projected to be shipped
by rail, water, or road routes outside a 5-mile radius of a nuclear power plant, the shipments need
not be considered further for evaluation for the same reason stated in the screening criteria for
stationary sources. If the shipments are within a 5-mile radius of a nuclear power plant, estimates
of the frequencies of these shipments should be considered in the evaluation of control room
habitability. Shipments are defined as being frequent1 if there are 10 total shipments per year for
truck traffic, 30 per year for rail traffic, or 50 per year for barge traffic. These frequencies are
based on transportation accident statistics, conditional spill probability given an accident, and a
limiting criterion for the number of spills or releases. These accident rates have remained
relatively constant for many years, therefore it is not necessary to revise these frequencies (Ref. 5).
Mobile sources need not be considered further if the total shipment frequency for all
hazardous chemicals, i.e., all hazardous chemicals considered as a singular cargo category without
further distinction of the nature of these chemicals, does not exceed the specified number by traffic
type. Frequent shipments, i.e., shipments exceeding the specified number by traffic type, need not
be considered in the analysis if the quantity of hazardous chemicals is less than the quantity shown
in the table in Appendix A (adjusted for the appropriate toxicity limit, meteorology, and control
room air exchange rate).
1
For explosive hazards, a lower number of shipments would be considered frequent since the effects of an explosion would be
independent of wind direction.
1.78-4
:
TABLE 1
This table lists commonly encountered chemicals but the list is not all-inclusive. A more complete
list of chemicals is in Reference 5.
a
Adapted from NUREG/CR-6624, “Recommendations for Revision of Regulatory Guide 1.78” (Ref. 5).
b
Parts of vapor or gas per million parts of air by volume at 25-C and 760 torr (standard temperature and pressure).
c
Approximate milligrams of particulate per cubic meter of air, at standard temperature and pressure, based on listed ppm values.
:
For release of hazardous chemicals from stationary sources or from frequently shipped
mobile sources in quantities that do not meet the screening criteria, detailed analysis should be
performed for control room habitability. Licensees are encouraged to make use of risk
information, particularly when requesting related license amendments. The guidance for risk
evaluation is provided in Regulatory Position 2. Licensees may continue to use the traditional
engineering approach for control room habitability evaluation; the guidance for this approach is
provided in Regulatory Position 3.
2. RISK EVALUATION
For releases of hazardous chemicals from stationary sources or from frequently shipped
mobile sources in quantities that do not meet the screening criteria in Regulatory Position 1.1 or
1.78-5
1.2, detailed analyses should be performed for control room habitability. Licensees may provide
risk information to demonstrate that the radiological risk to the public from such toxic chemical
releases is small, consistent with the Commission’s Safety Goal Policy Statement. Release of
toxic chemicals that have the potential to result in a significant concentration in the control room
need not be considered for further detailed evaluation if the releases are of low frequencies (10-6
per year or less) because the resultant low levels of radiological risk are considered acceptable. If
demonstrated, an acceptable level of risk may be used by licensees to support license amendment
requests.
Table 1 gives the toxicity limits (in ppm by volume and mg/m3) for the chemicals listed; a
more complete list of chemicals and their toxicity limits is provided in Reference 5. These limits
are based on the immediately dangerous to life and health (IDLH) exposure level concept (Ref. 7)
formulated by the National Institute for Occupational Safety and Health (NIOSH). The IDLH
value or limit, based on a 30-minute exposure level, is defined as one that is likely to cause death
or immediate or delayed permanent adverse health effects if no protection is afforded within 30
minutes. For each chemical considered, the IDLH limit can be tolerated for 2 minutes without
physical incapacitation (for example, severe coughing, eye burn, or severe skin irritation) of an
average human. Thus, a 2-minute exposure to the IDLH limits provides an adequate margin of
safety in protecting control room operators, and these limits are recommended (Ref. 5). It is
expected that a control room operator will take protective measures within 2 minutes (adequate
1.78-6
time to don a respirator and protective clothing) after the detection and, therefore, will not be
subjected to prolonged exposure at the IDLH concentration levels.
If toxicity limits of released chemicals are not available and no detection instruments are
available in the control room for the hazardous chemicals under consideration, the human
detection threshold, such as the odor threshold, may be used.
Two types of industrial accidents should be considered for each source of hazardous
chemicals: maximum concentration accidents and maximum concentration-duration accidents.
1.78-7
:
TABLE 2
CHEMICAL
CONTROL ROOM
1. Volume of the control room, including the volume of all other areas supplied by the
control room emergency ventilation system
2. Normal flow rates in cubic feet per minute for
- unfiltered inleakage or makeup air
- filtereda makeup air
- filtered recirculated air
3. Emergency flow rates for the above
4. Time required to isolate the control room
a
"Filtered air" refers to the air filtered through filters that have an established removal capability for the particular
chemical being considered.
:8
For both types of accidents, release of contents during an earthquake, tornado, or flood
should be considered for chemical container facilities that are not designed to withstand these
natural events. In the evaluation of control room habitability, it may also be appropriate to
consider hazardous chemical releases coincident with the radiological consequences (e.g., of a
design basis loss-of-coolant accident for plants that are vulnerable to both events simultaneously)
and demonstrate that such coincident events do not produce an unacceptable level of risk.
For chemicals that are not gases at 100-F and normal atmospheric pressure but are liquids
with vapor pressures in excess of 10 torr, consideration should be given to the rate of flashing and
boiloff to determine the rate of release to the atmosphere and the appropriate time duration of the
1.78-8
release. For lighter-than-air gases, the buoyancy effect should be considered in determining the
dispersion characteristics.
Irrespective of the dispersion model or the analysis tool used, the value of the atmospheric
dilution factor between the release point and the control room that is used in the analysis should
be that value that is exceeded only 5% of the time.
When boiloff or a slow leak is analyzed, the effects of density on vertical diffusion may be
considered if adequately substantiated by reference to data from experiments. The density effect
of heavier-than-air gases should not be considered for releases of a violent nature or for released
material that becomes entrained in the turbulent air near buildings. The density (buoyancy) effect
of lighter-than-air gases may be considered if adequately substantiated by reference to data.
The air flows for infiltration, makeup, and recirculation should be considered for both
normal and accident conditions. The volume of the control room and all other rooms, including
the ventilation systems, that share the same ventilating air, during both normal conditions and
accident conditions, should be considered.
The control room and emergency ventilation system should have low-leakage
construction. Low-leakage dampers or valves should be installed on the upstream side of
recirculation fans or other locations where negative system pressure exists and where inleakage
from contaminated atmospheric ambient air is possible.
The inleakage characteristics of the control room envelope during a hazardous chemical
challenge should be determined by testing. The testing should be conducted to a recognized
industry standard and performed to demonstrate control room envelope inleakage with systems
and components configured and operating as they would in the event of a hazardous chemical
challenge. Any test determining inleakage should ensure that the control room envelope, its
1.78-9
associated ventilation systems, and ventilation systems in adjacent areas are all aligned,
functioning, and performing in a manner consistent with the licensing bases.
A comprehensive test identifies all inleakage associated with the envelope. It is not
necessary to identify all inleakage sources. However, it is imperative that the testing to determine
inleakage be based upon the limiting condition for the type of challenge. This limiting condition
may change as systems, components, and operating modes are modified. An effective method
that has been used and accepted by the staff to perform a test of envelope inleakage is ASTM
E741- 95, “Standard Test Method for Determining Air Change in a Single Zone by Means of a
Tracer Gas Dilution” (Ref. 9). Additional guidance on control room envelope inleakage
determination for control room habitability testing is being developed and will be published as a
regulatory guide.
4. PROTECTION MEASURES
For adequate protection of the control room operators against the types of accidental
releases discussed above, features should be included in the plant design to (1) provide capability
to detect such releases, (2) isolate the control room if there is a release, (3) make the control room
sufficiently leak tight, and (4) provide equipment and procedures for ensuring the use of breathing
apparatus by the control room operators. Provisions that are adequate for the large instantaneous
release will also provide protection against the low-leakage-rate release. The guidance for Item 3
is provided in Section 3.4. The guidance for other design features is provided below. Licensees
may select and implement specific protection measures as long as these measures ensure adequate
protection. Implementation of protection measures for a particular chemical species may be
excluded if the detailed evaluation of control room habitability shows that the highest
concentration predicted in the control room is below the toxicity limit.
The detection system should be able to detect and signal a concentration level that is
significantly lower than the IDLH level, for example, a concentration level of 5 ppm for chlorine.
The detection system should be qualified for all expected environments, including severe
environments. The system should also be designated as Seismic Category I and be qualified as
such. The installation of the detectors should ensure that they are protected from adverse
temperature effects. The manufacturer's recommendations for maintenance, testing, and
calibration, as well as adjustment to such recommendations that are made by licensees, are
acceptable provided they follow sound engineering practices and are compatible with the
proposed application.
Human detection, i.e., smell, may be appropriate when no detection instruments are
available in the control room for given chemical types.
1.78-10
Quick-response detectors should be located in the fresh air inlets (both normal and
emergency air intakes). It may also be appropriate, depending on the design, to have separate
channels of detectors for fresh air inlets and to have detectors in the control room envelope
ventilation system recirculation lines. The system response time, which incorporates the detection
response time, the valve closure time, and associated instrument delays, should be less than or
equal to the isolation time.
Remote detectors may be located at storage and unloading locations. These detectors may
be placed and the detector trip points adjusted to ensure detection of either a leak or a container
rupture. A detector trip signal should isolate the control room before the toxic chemical arrives at
the isolation dampers. The detector trip signal should also set off an alarm and provide a readout
in the control room. An alternative to the installation of remote detectors would be to provide an
isolation system that uses local detectors with a very short isolation time.
The capability to close the air ducts of the control room with dampers and thus isolate the
control room should be considered in the evaluation of control room habitability. For onsite
storage, the capability to manually isolate the control room should be provided. Upon detection of
a toxic chemical, a detector should initiate complete closure of isolation dampers to the control
room with minimal delay. The isolation time is a function of the control room design, in
particular, the inleakage characteristics. If the detectors are upstream from the isolation dampers,
credit will be allowed for the travel time between the detectors and the dampers.
The isolation system and its components, the recirculating filter system, and the air
conditioning system should meet IEEE Std 603-1991, "Criteria for Safety Systems for Nuclear
Power Generating Stations" (Ref. 10), since these systems are needed to maintain a habitable
environment in the control room during design basis radiological events.
For plants that isolate control rooms, steps should be taken to ensure that the isolated
exchange rate is not inadvertently increased by design or operating error. Ventilation equipment
for the control room and for the adjacent zones should be reviewed to ensure that enhanced air
exchange between the isolated control room and the outside will not occur. All doors leading to
the control room should be kept closed when not in use.
If the evaluation of possible accidents for any hazardous chemical indicates that the
applicable toxicity limits may be exceeded in the control room, measures should be in place to
provide adequate protection to control room operators. The use of full-face self-contained
pressure-demand-type breathing apparatus (or the equivalent) and protective clothing should be
considered. Adequate air capacity for the breathing apparatus (at least 6 hours) should be readily
available onsite to ensure that sufficient time is available to transport additional bottled air from
offsite locations. This offsite supply should be capable of delivering several hundred hours of
bottled air. Sufficient units of breathing apparatus should be provided for the emergency crew.
1.78-11
Storage provisions for breathing apparatus and procedures for its use should be such that
operators can begin using the apparatus within 2 minutes after detection of a hazardous release.
Breathing apparatus, air supply equipment, and protective clothing should meet the criterion that a
single toxic gas event would not render nonfunctional the total inventory of such protective
equipment.
5. EMERGENCY PLANNING
The licensee should have written emergency procedures to be initiated in the event of a
hazardous chemical release within or near the plant. These procedures should address both
maximum concentration accidents and maximum concentration-duration accidents and should
identify the most probable chemical releases at the station. Methods of detecting the event by
station personnel, both during normal workday operation and during minimum staffing periods
(late night and weekend shift staffing), should be discussed. Special instrumentation that has been
provided for the detection of hazardous chemical releases should be described; the description
should include the action initiated by the detecting instrument and the level at which this action is
initiated. The emergency procedures should describe the isolation of the control room, the use of
protective breathing apparatus or other protective measures, and maintenance of the plant in a safe
condition, including the capability for an orderly shut down or scram. Criteria and procedures for
evacuating nonessential personnel from the station should also be described.
The emergency planning should include training emergency planning personnel on the use
of instruments. It should also include periodic drills on the procedures.
Arrangements should be made with Federal, State, and local agencies or other cognizant
organizations for the prompt notification of the nuclear power plant when accidents involving
hazardous chemicals have occurred within 5 miles of the plant.
D. IMPLEMENTATION
The purpose of this section is to provide information to licensees and applicants regarding
the NRC staff’s plans for using this revised regulatory guide.
1.78-12
REFERENCES
2. USNRC, “Fire Protection for Operating Nuclear Power Plants,” Regulatory Guide 1.189,
April 2001.1
7. NIOSH, “NIOSH Pocket Guide to Chemical Hazards,” National Institute for Occupational
Safety and Health, 1997.
8. J.V. Ramsdell, Jr., and S.A. Stage, “Computer Codes for Evaluation of Control Room
Habitability (HABIT V1.1),” NUREG/CR-6210, Supplement 1 (Prepared for the NRC by
Pacific Northwest National Laboratory), USNRC, October 1998.3
1
Single copies of regulatory guides, both active and draft, may be obtained free of charge by writing the Reproduction and
Distribution Services Section, OCIO, USNRC, Washington, DC 20555-0001, or by fax to (301)415-2289, or by email to
<[email protected]>. Active guides may also be purchased from the National Technical Information Service on a
standing order basis. Details on this service may be obtained by writing NTIS, 5285 Port Royal Road, Springfield, VA 22161;
telephone (703)487-4650; online <http://www.ntis.gov/ordernow>. Copies of active and draft guides are available for inspection
or copying for a fee from the NRC Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDR’s mailing address
is USNRC PDR, Washington, DC 20555; telephone (301)415-4737 or (800)397-4209; fax (301)415-3548; email
<[email protected]>.
2
May be read or downloaded from NRC’s web site, WWW.NRC.GOV, through The Commission’s Activities.
3
Copies are available at current rates from the U.S. Government Printing Office, P.O. Box 37082, Washington, DC 20402-9328
(telephone (202)512-1800); or from the National Technical Information Service by writing NTIS at 5285 Port Royal Road,
Springfield, VA 22161; (telephone (703)487-4650; www.ntis.gov/ordernow. Copies are available for inspection or copying for a
fee from the NRC Public Document Room at 11555 Rockville Pike, Rockville, MD; the PDR’s mailing address is USNRC PDR,
Washington, DC 20555; telephone (301)415-4737 or (800)397-4209; fax (301)415-3548; email is [email protected].
1.78-13
9. ASTM, “Standard Test Method for Determining Air Change in a Single Zone by Means of
a Tracer Gas Dilution, ASTM Standard E741-95, American Society for Testing and
Materials, 1995.
10. IEEE, “Criteria for Safety Systems for Nuclear Power Generating Stations, “ IEEE Std
603-1991, Institute of Electrical and Electronics Engineers, 1991.4
4
Copies may be obtained from IEEE Service Center, 445 Hoes Lane, Piscataway, New Jersey 08855-1331.
1.78-14
APPENDIX A
The weights presented in the following table are based on a toxicity limit of 50 mg/m3; air
exchange rates of 0.015, 0.06, and 1.2 per hour, respectively; and a Pasquill stability category F
representing the worst 5% of meteorological conditions observed at a majority of nuclear plant
sites.
An air exchange rate of 0.015 (i.e., 0.015 of the control room air by volume is
replaced by atmospheric ambient air in one hour) is considered representative of a “tight”
control room that has very low-leakage construction features and automatic isolation
capabilities. An air exchange rate of 0.06 per hour is considered representative of a control
room that has normal leakage construction features and automatic isolation capabilities,
whereas an air exchange rate of 1.2 per hour is considered representative of a control room
with construction features that are not as efficient for leakage control and without automatic
isolation capabilities.
If the toxicity limit, air exchange rate, or meteorological conditions are different
from the assumptions used in the table, simple calculations using the following procedures
can be performed to determine the weights of hazardous chemicals that are to be considered
1.78-15
for the control room evaluation. Note that the weights in the table are based on EXTRAN
calculations without the wake effect correction.
Toxicity Limit
The weights presented in the table are directly proportional to the toxicity limit. If a
particular chemical has a toxicity limit of 500 mg/m3, the weights from the table (based on
50 mg/m3) should be increased by a factor of 10.
The weights in the table are inversely proportional to the air exchange rate. If a
control room has an exchange rate of 2.4 per hour, the weights from the table (based on 1.2
per hour) are decreased by a factor of two. In other words, the weights are appropriately
adjusted for the actual fresh air exchange rate. The current crop of control rooms with
automatic isolation capabilities may have leakage characteristics different from those listed
in the Table. Again, appropriate adjustments of weight should be made based on the actual
air exchange rate. It should be noted that the use of an air exchange rate of less than 0.06
per hour for an isolated control room requires that the control room leakage rate be verified
by periodic field testing.
E 2.5
F 1.0
G 0.4
1.78-16
REGULATORY ANALYSIS
A draft regulatory analysis was published with the draft of this guide when it was
published for public comment (DG-1087, February 2001). No changes were necessary, so a
separate value/impact statement for Revision 1 of Regulatory Guide 1.78 has not been prepared.
A copy of the draft value/impact statement is available for inspection or copying for a fee in the
NRC’s Public Document Room at 11555 Rockville Pike, Rockville, MD, under DG-1087. An
electronic version of DG-1087 is available in the NRC’s Electronic Reading Room under
accession number ML010440064.