Legrand 56661 Datasheet

The document provides information on P17 combined units, which are products for distributing power close to equipment. It includes details on the units' descriptions, uses, ranges of options, dimensions, connection methods, technical characteristics, wiring diagrams, standards, and accessories. The units come in various configurations including single and multi-socket units, with switches, sockets, and protection devices for different current types. Diagrams and specifications are given for panel mounting and surface mounting units.

Uploaded by

helmi.rifki
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
130 views19 pages

Legrand 56661 Datasheet

The document provides information on P17 combined units, which are products for distributing power close to equipment. It includes details on the units' descriptions, uses, ranges of options, dimensions, connection methods, technical characteristics, wiring diagrams, standards, and accessories. The units come in various configurations including single and multi-socket units, with switches, sockets, and protection devices for different current types. Diagrams and specifications are given for panel mounting and surface mounting units.

Uploaded by

helmi.rifki
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

87045 LIMOGES Cedex

Telephone: +33 (0)5 55 06 87 87 - Fax: +33 (0)5 55 06 88 88

P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

CONTENTS Page

1. Description . . . . . . . . . . . . . . . . . . . . . 1
2. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3. Range . . . . . . . . . . . . . . . . . . . . . . . . 1-3
4. Dimensions . . . . . . . . . . . . . . . . . . . . 4-8
5. Connection . . . . . . . . . . . . . . . . . . . . . 9
6. Technical characteristics . . . . . . . . . 9-10
7. Wiring diagrams . . . . . . . . . . . . . . 11-15
8. Standards . . . . . . . . . . . . . . . . . . . 16-18
9. Accessories . . . . . . . . . . . . . . . . . . . . 19

1. DESCRIPTION 3. RANGE
• Product for distributing power close to equipment 3.1 Single socket units
• Supply of several current types (amps/volts) for industrial and/or • Single socket units with switch (surface and panel mounting version)
domestic pin configuration 16 and 32 A
• Power supply for one or more devices • Single socket units with switch and rail (surface and panel mounting
• Protection of users and circuits: version) 16 and 32 A
- off-load connection and disconnection provided by units • Single socket unit 63 A
equipped with switched socket with double mechanical
interlock Panel Single unit with Single unit with
- protection by MCB, RCBO, RCD (RCCB) mounting switch and switch and rail
• Material: plastic socket with junction box (5 modules)
• Colour: RAL 7035 switch
• IK08
3P+E 0 572 94 0 972 98 0 589 18
• IP44, IP55, IP66 400V 63A
• Classe II 3P+E+T 0 572 95 0 589 10 0 572 99

2. USE • Single ELV combined unit


• Switch with double mechanical interlock:
1st interlock: switch cannot be turned on unless a plug has been Panel Panel Surface
inserted mounting mounting mounting
2nd interlock: plug cannot be removed when the switch is on socket without socket with socket wit-
• Marking of the switch ON and OFF positions rail with protection hout rail with
• Transparent window to view protection devices transformer device and transformer
• Cable entries to be drilled 150 VA transformer 150 VA
• Equipped or to be equipped with panel mounting sockets with 160 VA
standard fixing centres (70 x 70)
• Plug-in system: socket can be wired quickly in the cover independently 24V 16A 2P 0 589 26 0 589 25 0 589 27
of the box already fixed to the wall

3.2 Multi-socket combined units


Combined units with 2 IP44 sockets
Cat. No. 0 589 20 (can take up to 3 sockets)
External dimensions: W 265 x H 441 mm
13 Lexic modules max.
In A : 16 A according to IEC 61439-2 and 61439-3
1 x 16 A 2P 24 V (faceplate socket with transformer 150 VA)
1 x 16 A 2P+E 230 V IP44 socket
1 x blanking plate for a third socket
1 x 2-pole MCB 6 A (Cat. No. 0 064 64 or 4 077 80)
1 x 2-pole MCB 16 A (Cat. No. 0 064 68 or 4 077 84)
1 x 2-pole MCB 32 A (Cat. No 0 064 61 or 4 077 77)

Cat. No. 589 21 (can take up to 3 sockets)


External dimensions: W 265 x H 441 mm
13 Lexic modules max.
In A : 40 A according to IEC 61439-2
: 30 A according to IEC 61439-3
1 x 16 A 2P+E 230 V IP44 socket
1 x 32 A 3P+N+E 400 V IP44 socket
1 x blanking plate for a third socket
1 x 2-pole MCB 16 A (Cat. No. 0 064 68 or 4 077 84)
1 x 4-pole MCB 32 A (Cat. No. 0 065 66 or 4 079 01)

Technical sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

1/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

3. RANGE (continued) 3. RANGE (continued)


Cat. No. 0 589 30 Combined units with 5 sockets
External dimensions: W 125 x H 371 mm Cat. No. 0 589 22
5 Lexic modules max. External dimensions: W 405 x H 441 mm
In A : 20 A according to IEC 61439-2 and 61439-3 18 Lexic modules max.
2 x 16 A 2P+E 230 V IP44 sockets In A : 32 A according to IEC 61439-2 and 61439-3
1 x 2-pole MCB 20 A (Cat. No. 4 077 85) 2 x 16 A 2P 24 V ELV socket with transformer 150 VA
1 x 16 A 2P+E 250 V domestic pin configuration socket
Cat. No. 0 589 31 1 x 16 A 2P+E 230 V IP44 socket
External dimensions: W 125 x H 371 mm 1 x 16 A 3P+E 400 V IP44 socket
5 Lexic modules max. 1 x 4-pole RCCB 40 A (Cat. No. 0 086 94 or 4 116 61)
In A : 20 A according to IEC 61439-2 and 61439-3 1 x 2-pole MCB 6 A (Cat. No. 4 077 80)
2 x 16 A 2P+E 250 V domestic pin configuration sockets 1 x 3-pole MCB 16 A (Cat. No. 4 078 29)
1 x 2-pole MCB 20 A (Cat. No. 4 077 85) 1 x 2-pole MCB 2 A (Cat. No. 4 077 77)
1 x 2-pole MCB 20 A (Cat. No. 4 077 85)
Cat. No. 0 589 32
External dimensions: W 125 x H 371 mm 3.3 Multi-socket combined units with faceplates
5 Lexic modules max. To be equipped with 16 A sockets with standard fixing centres (70 x 70)
In A : 20 A according to IEC 61439-2 and 61439-3 only or domestic pin configuration sockets 0 576 71 and 0 576 72.
1 x 16 A 2P+E 230 V IP44 socket
Cat. No. No. of modules Characteristics Ext. dim. (HxW)
1 x 16 A 3P+E 400 V IP44 socket
1 x 4-pole MCB 20 A (Cat. No. 4 078 99) 0 577 07 5 for 3 x 16 A sockets 421 x 125

0 577 08 12 for 4 x 16 A sockets 441 x 265


Cat. No. 0 589 37
External dimensions: W 125 x H 371 mm 0 577 09 18 for 6 x 16 A sockets 441 x 405
5 Lexic modules max.
In A : 20 A according to IEC 61439-2 and 61439-3 3.4 Self assembly combined units: bases for junctions
1 x 16 A 2P+E 230 V IP44 socket
Cat. No. Characteristics Ext. dim. (HxW)
1 x 16 A 2P+E 250 V domestic pin configuration socket
1 x 2-pole MCB 20 A (Cat. No. 4 077 85) 0 577 00 for 1 interlocked socket or 1 faceplate 280 x 125 421 x 125
for 2 interlocked sockets or 2 faceplates
0 577 01 501 x 265
Combined units with 3 sockets 280 x 125
Cat. No. 0 589 33 for 3 interlocked sockets or 3 faceplates
0 577 02 501 x 405
External dimensions: W 125 x H 421 mm 280 x 125
5 Lexic modules max.
In A : 20 A according to IEC 61439-2 and 61439-3 Note: Some Cat. Nos. in this range will only be sold until stocks run out.
2 x 16 A 2P+E 250 V domestic pin configuration sockets
1 x 16 A 2P+E 230 V IP44 socket 3.5 Combined unit for use in refrigerated containers
1 x 2-pole MCB 20 A (Cat. No. 4 077 85) Cat. No. 0 657 106
Combined unit 3P+E 32 A 440 V - earth at 3 o’clock - with switch and IP
Cat. No. 0 589 34 (can take up to 4 sockets) 66/67 socket outlet
External dimensions: W 265 x H 441 mm Perishable goods are transported in refrigerated containers by road, sea
12 Lexic modules max. and rail all over the world. The power is supplied by a combined unit
In A : 20 A according to IEC 61439-2 and 61439-3 designed for use in refrigerated containers by long haulage companies
2 x 16 A 2P+E 250 V domestic pin configuration sockets (container terminals, transit areas, railway stations, ports, airports,
1 x 16 A 2P+E 230 V IP44 socket warehouses, ships, etc.).
1 x 2-pole MCB 20 A (Cat. No. 4 077 85)
1 x blanking plate for a fourth socket Associated mobile products:
Plug: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 571 26
Combined unit with 4 sockets Mobile socket:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 571 46
Cat. No. 0 589 35 (can take up to 5 sockets)
External dimensions: W 265 x H 501 mm Associated fixed product:
12 Lexic modules max. Panel mounting socket: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 571 16
In A : 40 A according to IEC 61439-2 and 61439-3
2 x 16 A 2P+E 250 V domestic pin configuration sockets 120
Fix.106
1 x 16 A 2P+E 230 V IP44 socket 152
M20/M25

M20/M25

1 x 32 A 3P+E 400 V IP44 socket 20


1 x 2-pole MCB 20 A (Cat. No. 4 077 85) Ø 6,2 10 PE

1 x 3-pole MCB 32 A (Cat. No. 4 078 32)


1 x 4-pole RCCB 63 A (Cat. No. 4 116 62) Fix.70
1 x blanking plate for a fifth socket
Fix.190
Fix.216
230

Cat. No. 0 589 36 (can take up to 5 sockets)


25

External dimensions: W 265 x H 501 mm M25/


Ø29
46

12 Lexic modules max. Ø6


In A : 40 A according to IEC 61439-2 and 29 A according to 61439-3
2 x 16 A 2P+E 250 V domestic pin configuration sockets 6,2
PE
1 x 16 A 2P+E 230 V IP44 socket
M20/M25
M20/M25

1 x 32 A 3P+N+E 400 V IP44 socket


1 x 2-pole MCB 20 A (Cat. No. 4 077 85)
1 x 4-pole MCB 32 A (Cat. No. 4 079 01)
1 x 4-pole RCCB 63 A (Cat. No. 4 116 62)
1 x blanking plate for a fifth socket

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 2/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

3. RANGE (continued)
3.5 Self assembly combined units: bases and boxes

Example configuration of a combined unit

MCBs, RCCB, etc.

Base Faceplate Sockets Combined unit

COMBINED UNITS HEIGHT 220 MM TO 441 MM

BASES FOR 220 X 125 MM FACEPLATES 220 X 125 MM FACEPLATES

1 x 16 or 32 A 2 x 16 A 1 x 63 A
Surface Base for up to Base for up to Base for up to Plain plate
socket sockets socket
mounting box 2 x16 A sockets 4 x16 A sockets 6 x16 A sockets

Take wall mounting lugs


Cat. No. 0 019 69

220 x 125 mm(5) 441 x 265 mm(5)


371 x 125 mm(5) 441 x 405 mm(5)
13-module DIN
5-module DIN rail 20-module DIN rail
rail

Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No

1 0 577 10(7) 1 0 589 38(7) 1 0 577 05(8) 1 0 577 06(8) 5 0 577 12 5 0 577 13(2) 2 0 577 17 5 0 577 15

COMBINED UNITS HEIGHT 280 MM TO 501 MM

BASES FOR 280 X 125 MM FACEPLATES 280 X 125 MM FACEPLATES

1 x 16 or 32 A
2 x 16 A or 32 socket 3 x 16 A
Surface Base for up to Base for up to Base for up to Plain plate
A sockets and 1 x 63 A sockets (3)
mounting box 3 x 16 A sockets 6 x16 A sockets x 16 A sockets socket
Take wall mounting lugs
Cat. No. 0 019 69

280 x 125 mm(5) 421 x 125 mm(5) 501 x 265 mm(5) 501 x 405 mm(5)
5-module DIN rail 13-module DIN rail 20-module DIN rail

Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No Pack Cat. No

0 577 0 577 0 577


3 0 577 11(7) 1 0 577 20(7) 1 0 577 03(8) 1 0 577 04(8) 4 2 4 4 0 577 16
18(2) 19(2) 14(2)

(1) Can take a key-operated lock Cat. No. 0 577 35 - (2) Supplied with blanking plate
(3) To be mounted horizontally except 16 A domestic pin sockets which must be mounted vertically (IP44 with plug inserted)
(4) IP 54 cover closed - IP 44 connected (5) External dimensions: H x W - (6) For faceplate Cat. No. 0 577 17/19
(7) Can be pole-mounted using kit Cat. No. 0 364 46/47/48/49 (see data sheet in e-catalogue for compatibility) - (8) See 1 + 7 - (9) Wiring required for pilot wire

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 3/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

4. DIMENSIONS 4. DIMENSIONS (continued)


Surface or panel mounting 16/32 A single unit with switch Surface mounting 63 A single unit with switch and rail
Cat. Nos. 0 572 99/0 589 18
125 122

501
550
IP 44 Dimensions (mm) IP 55 Dimensions (mm)
Cat. No. A B Cat. No. A B
2P+E 0 566 01 127 122 0 566 21 133 128
LV
3P+E 0 566 05 129 124 0 566 25 134 129 175
16 A
3P+N+E 0 566 06 130 125 0 566 26 135 130
2P+E 0 566 09 138 133 0 566 29 143 138 Panel mounting 63 A single unit with switch
LV
3P+E 0 566 13 138 133 0 566 33 143 138
Cat. Nos. 0 572 94/95
32 A 160
3P+N+E 0 566 14 139 134 0 566 34 144 139 125 129
Refer to these dimensions for similar Cat. Nos.
Surface or panel mounting 16/32 A single unit with rail and switch
320

ELV sockets and combined units


Cat. No. 0 589 25
125
Fix.107 140

IP 44 Dimensions (mm) IP 55 Dimensions (mm)


Cat. No. A B C Cat. No. A B C
Fix.115

Fix.100
2P+T 0 566 40/41 290 125 155 0 566 60/61 300 125 155
LV
16

3P+T 0 566 45 290 125 155 0 566 65 300 125 155


16 A
280

3P+N+T 0 566 46 290 125 155 0 566 66 300 125 155


2P+T 0 566 49 295 125 155 0 566 69 310 125 155
Fix.147

LV
3P+T 0 566 53 295 125 155 0 566 73 310 125 155
32 A
3P+N+T 0 566 54 295 125 155 0 566 74 310 125 155
Refer to these dimensions for similar Cat. Nos. Ø 3,5
Fix.107
Surface mounting 63 A single unit with switch (without rail)
Cat. Nos. 0 572 98/0 589 10

Cat. No. 0 589 26


Fix.202
220

10

Ø 3,5 90
Fix.107
120
125
170

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 4/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

4. DIMENSIONS (continued) 4. DIMENSIONS (continued)


Cat. No. 0 589 27 5 sockets with MCB + RCCB + transformer
125 Cat. No. 0 589 22
Entry to drill Entry to drill
Fix.86 Max. M32 31 122
Max. M32
405 31
Fix. 314
20
220

5
F ix .95

10°

Fix. 350
441
Entry to drill
Max. M25 25
18
100
128 25
180
Entry
18 to drill
Max. M25 128
2 sockets with MCB and transformer 140 140
Cat. No. 0 589 20
265 122
Entry to drill 2 sockets with MCB
Fix.174 Max. M32 31
Cat. Nos. 0 589 30/32
125 Entry to drill
Max. M32
Fix. 86
10 107

31
Fix.350
441

Fix. 290
361

25

Entry to drill
Max. M25 25
52 88 17
128 128
Entry to drill
Max. M25

2 sockets with MCB Cat. No. 0 589 31


Cat. No. 0 589 21 125 Entry to drill
265 Entry to drill 122 Max. M32
Fix. 174 Max. M32 Fix. 86
31 10 107

31
Fix. 290
361
Fix. 350

25
441

17

Entry to drill 110


Max. M25
25
Cat. No. 0 589 37
Entry to drill
125 Entry to drill
52 88 Max. M25
137 Max. M32
Fix. 86
10 107

31
Fix. 290
361

25

17

Entry to drill 128


Max. M25

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 5/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

4. DIMENSIONS (continued) 4. DIMENSIONS (continued)


3 sockets with MCB Multi-socket combined units equipped with faceplates
Cat. No. 0 589 33 Cat. No. 0 577 07
125 Entry to drill 107
Fix. 70 Max. M32 31

Max. M32
Entry to drill

Rail fixed
by 2
Fix. 351
421

screws

Cover with
20 window

Entry to drill
23 Max. M20
111

Cat. No. 0 589 34


265 122
Entry to drill Max. M20
Fix. 174 Max. M32 31 Entry to drill

Cat. No. 0 577 08


Fix. 350
441

Max. M32
Entry to drill

25

Entry to drill
88 Max. M25 Rail fixed
52 by 2
128 screws

4 sockets with MCB and RCCB


Cat. Nos. 0 589 35/36 Cover with
window
Entry to drill
Max. M32
265 122
Fix. 174 31

Max. M25
Fix. 210

Entry to drill
501

Fix. 200

20

47 93

Entry to drill A
Max. M20

A
0 589 35 119
0 589 36 120

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 6/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

4. DIMENSIONS (continued) 4. DIMENSIONS (continued)


Cat. No. 0 577 09 Bases
Cat. Nos. 0 577 01/03
Max. M32
Cover with 265 122
Entry to drill window
Fix. 174 31

5
Maxi M32

Fix. 210

501
Rail fixed

Fix. 200
by 2
screws
Maxi M20
20

47 93 46

Cat. Nos. 0 577 02/04


405 122
Fix. 314 31

Max. M32
Entry to drill
5

Maxi M32
Fix. 210

501
Fix. 200

Maxi M20
20

140 140 46
18

Cat. No. 0 577 05


265 122
Fix. 174 31
5

Maxi M32
Fix. 350

441

Maxi M25 25

52 88 76,5

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 7/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

4. DIMENSIONS (continued) 4. DIMENSIONS (continued)


Cat. No. 0 577 06 Boxes
405 122 Cat. Nos. 0 577 10/11
125 46
Fix. 314 31
Fix.70 maxi 21
125 76,5 M25
Fix.86 31
maxi
M32
5

Maxi M32

5
Fix. 210
220
Fix. 350

280
441

Fix. 95
5
maxi
M25
20
Maxi M25 25 18 25

maxi
23 M20
140 140 76,5
18
Faceplates
Cat. Nos. 0 577 12/13/15/17
Cat. Nos. 0 577 00/20
125 107
Fix. 70 31

maxi
130

M32
5

Entry
to
drill
Fix. 351

421

Cat. Nos. 0 577 14/16/18


280

46
20

maxi
23 M20
Entry
to
drill

Cat. No. 0 589 38


Entry
125 to drill 107
Fix. 86 Max. 31
M32
Cat. No. 0 577 19
10

130
5
Fix. 290
361

Entry
to drill
Max.
M25

17,5 25
72

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 8/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

5. CONNECTION AND PROTECTION 6. TECHNICAL CHARACTERISTICS (continued)


5.1 Connection of units 6.5 Operating temperatures
Cable cross-section inside the unit, according to the current rating: -25°C/+40°C
(see §8.2)
Reminder of circuit breaker derating according to ambient temperature.
5.2 Protection A standardised circuit breaker is adjusted to operate at In at an ambient
The combined units are equipped with Lexic modular MCB and/or temperature of 30 °C.
Lexic RCCB (see page 1/2). The nominal characteristics of this device are modified according to
the ambient temperature inside the cabinet or the enclosure where the
NB: According to the required use, it is essential to check that circuit breaker is located.
protection against indirect contact (residual current) and protection
against overloads and short circuits (Lexic circuit breakers) are both Ambient temperature/IM
provided.
In -10 °C 0 10 °C 20 °C 30 °C 40 °C
Caution: A residual current device does not provide protection against
overloads and short circuits. 0.5 A 0.6 0.57 0.55 0.52 0.5 0.47
Short-circuit withstand: For the short-circuit withstand of modular
0.8 A 0.96 0.92 0.88 0.84 0.8 0.76
circuit breakers, RCBOs and RCCBs, refer to the performance pages
for these products in the current Legrand catalogue. 1A 1.17 1.1 1.07 1.03 1 0.97
2A 2.34 2.21 2.14 2.06 2 1.94
Reminder of the ratings for units equipped with RCCB
Rating Sensitivity
3A 3.5 3.36 3.24 3.12 3 2.88
-16 A.......................25 A RCCB 4A 4.7 4.44 4.28 4.12 4 3.88
-32 A.......................40 A RCCB 30mA
-40 A.......................63 A RCCB 6A 7 6.6 6.4 6.18 6 5.8
8A 9.6 9.2 8.8 8.4 8 7.6

6. TECHNICAL CHARACTERISTICS 10 A 11.5 11.1 10.7 10.3 10 9.7


6.1 Glow wire test 13 A 15 14.3 13.9 13.4 13 12.6
- live parts: 850 °C
16 A 18.7 18 17.3 16.6 16 15.4
- housing: 650 °C
20 A 23.2 22.4 21.6 20.8 20 19.2
6.2 Dielectric strength
25 A 29.5 28.3 27.2 26 25 24
- equipped with IEC sockets: 2,500 V
- equipped with domestic sockets: 2,000 V 32 A 37.8 36.5 34.9 33.3 32 30.7
40 A 48 46 44 42 40 38
6.3 UV resistance
IDose rate: 550 W/m2 50 A 60 57.5 55 52,5 50 47.5
Test duration: 168 hours
63 A 75.6 72.5 69.9 66.1 63 59.8
Infrared and ultraviolet filter in order to get as close to the solar
spectrum as possible
6.6 Resistance to chemical agents
6.4 Breaking capacities
Aqueous solutions Housing Window
16A 32A 63A
Cold water . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ ++
AC 23 8.4 kW 16.8 kW Warm water . . . . . . . . . . . . . . . . . . . . . . . . . . . + ++
AC 22 Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- ++
33 kW
AC 23B 5% saline solution . . . . . . . . . . . . . . . . . . . . . . ++ ++
Oxygenated water . . . . . . . . . . . . . . . . . . . . . . - ++
Water + detergent . . . . . . . . . . . . . . . . . . . . . . + -
Water + surfactants . . . . . . . . . . . . . . . . . . . . . + +
Formic aldehide . . . . . . . . . . . . . . . . . . . . . . . . - ++
Alcohols
Ethanol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . + +
Methanol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . + -
Propanol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ -
Butanol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ -
Glycols
Ethylene glycol . . . . . . . . . . . . . . . . . . . . . . . . - +
Phenols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - -
Cresols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bases
Ammonia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . + -
Sodium hydroxide (caustic soda) . . . . . . . . . . ++ -
Sodium hypochlorite (bleach 12°) . . . . . . . . . . ++ +
Potassium hydroxide (potash) . . . . . . . . . . . . . ++ -
Oxydizing strong acids
Concentrated acetic acid . . . . . . . . . . . . . . . . . + ++

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 9/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

6. TECHNICAL CHARACTERISTICS (continued) 6. TECHNICAL CHARACTERISTICS (continued)

Housing Window
Nitric acid 5% . . . . . . . . . . . . . . . . . . . . . . . . . - ++ Resistance to chemical agents at ambient temperature according to risk of
Sulfuric acid 10% . . . . . . . . . . . . . . . . . . . . . . . + ++ exposure by spraying
Hydrochloric acid 30% . . . . . . . . . . . . . . . . . . . . + (++) excellent resistance (continuous exposure)
(+) good resistance (long-term exposure)
Perchloric acid 70% . . . . . . . . . . . . . . . . . . . . . . + (-) limited resistance (brief exposure possible)
Hydrofluoric acid 70% . . . . . . . . . . . . . . . . . . . - ++ (--) poor resistance (exposure to be avoided)
Chromic acid 50% . . . . . . . . . . . . . . . . . . . . . . + +
Phosphoric acid 30% . . . . . . . . . . . . . . . . . . . . + +
Weak acids
Diluted acetic acid < 25% . . . . . . . . . . . . . . . . ++ ++
Citric acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ ++
Lactic acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ ++
Formic acid . . . . . . . . . . . . . . . . . . . . . . . . . . . - -
Uric acid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ +
Animal oils and fats
Lard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . + -
Butter, cream . . . . . . . . . . . . . . . . . . . . . . . . . . ++ ++
Vegetable oils and fats
Linseed oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ -
Groundnut/olive oil . . . . . . . . . . . . . . . . . . . . . ++ +
Castor oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ ++
Glycerin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - -
Mineral oils and fats
Paraffin (vaseline) . . . . . . . . . . . . . . . . . . . . . . ++ ++
Engine oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -
Silicone oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . ++ ++
Cutting oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . + -
Hydraulic fluid . . . . . . . . . . . . . . . . . . . . . . . . . + --
Hydrocarbons
Unleaded petrol . . . . . . . . . . . . . . . . . . . . . . . . + -
Diesel oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . + +
Kerosene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . + +
White spirit . . . . . . . . . . . . . . . . . . . . . . . . . . . . + -
Chlorinated solvents
Trichloroethylene . . . . . . . . . . . . . . . . . . . . . . . - --
Trichloroethane . . . . . . . . . . . . . . . . . . . . . . . . - -
Perchloroethylene . . . . . . . . . . . . . . . . . . . . . . - --
Methyl chloride . . . . . . . . . . . . . . . . . . . . . . . . -- --
Carbon tetrachloride . . . . . . . . . . . . . . . . . . . . - --
Chloroform . . . . . . . . . . . . . . . . . . . . . . . . . . . . --
Aromatic solvents
Benzen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - -
Toluene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - -
Xylene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - -
Alphatic solvents
Hexane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - +
Heptane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluoride solvents
Trichlorofluoromethane . . . . . . . . . . . . . . . . . . - --
Ketones
Acetone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- --
Methyl ethyl ketone . . . . . . . . . . . . . . . . . . . . . -- --
Ethyl acetate . . . . . . . . . . . . . . . . . . . . . . . . . . -- --
Terpenes
Turpentine . . . . . . . . . . . . . . . . . . . . . . . . . . . . - -

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 10/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

7. WIRING DIAGRAMS
Cat. No. 0 589 20

Cat. No. 0 589 21

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 11/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

7. WIRING DIAGRAMS (continued)


Cat. No. 0 589 22

Cat. Nos. 0 589 30/31/37

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 12/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

7. WIRING DIAGRAMS (continued)


Cat. No. 0 589 32

Cat. Nos. 0 589 33/34

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 13/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

7. WIRING DIAGRAMS (continued)


Cat. No. 0 589 35

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 14/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

7. WIRING DIAGRAMS (continued)


Cat. No. 0 589 36

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 15/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

8. STANDARDS
• EN 60309-1 and IEC 60309-1 (conception)
• EN 60309-2 and IEC 60309-2 (interchangeability)
• EN 60309-4 and IEC 60309-4 (with locking device)
• EN 60529 and IEC 60529
• EN 62262 and IEC 62262
• EN 610439-1 and IEC 61439-1

8.1 Standards 61 439


• IEC 61439-2 and IEC 61439-3

Low-voltage switchgear assembly normative change:

The IEC 60439 standard series has been replaced by the IEC 61439 standard series. This series describes the construction and verification require-
ments for low-voltage switchgear assemblies.
It is applicable to electricity distribution in industry, construction sites and household environments.
IEC 61439-1 defines the general rules, and cannot be used alone.
For each context of use, an IEC 61439- X standard is applicable. All the points discussed refer systematically to the relevant chapter of IEC 61439-1,
adding any details or amendments associated with the context of use.
• IEC 61439-2: Power switchgear assemblies
• IEC 61439-3: Distribution boards intended to be operated by ordinary persons (DBO)
• IEC 61439-4: Particular requirements for assemblies for construction sites (ACS)
Important points in relation to switchgear assemblies:

Important points in relation to switchgear assemblies:


Definitions:

• Original manufacturer: Organisation that has carried out the original design and associated verification of an assembly
• Assembly manufacturer: Organisation taking responsibility for the completed assembly.
• User: Party who will specify, purchase, use and/or operate the assembly, or someone acting on their behalf.
Assembly manufacturer obligations
• Obligation to comply with the design and construction rules of IEC61439-x
• Obligation to test as per IEC61439
• Obligation to furnish a “Design Verification”
• Obligation to provide specific information:
On a label (or similar) attached to the product, legible on the installed product for some of the information to be provided.
In the “assembly manufacturer’s” technical documentation for the remaining information to be provided (characteristics, handling instructions,
installation, operation, maintenance).

Responsibilities:

The user is responsible for clearly specifying the installation and operating conditions (site, ambient temperatures, etc.).

The original manufacturer is responsible for carrying out the design, original manufacture, associated verifications and producing the technical docu-
mentation and verifications.
The assembly manufacturer producing an assembly is responsible for carrying out the mandatory tests and verifications. They must also issue a
design verification and ensure compliance with information requirements.
The assembly manufacturer, if converting, supplementing or modifying an assembly in accordance with IEC61439, is responsible for carrying out
further verifications, carrying out further tests, and providing further design and information verifications. In other words, in this case, the original
manufacturer loses its status as an assembly manufacturer.
Note:
As regards the latter paragraph, the rationale applies for subsequent maintenance operations, with the exception of the replacement of a component
if it is replaced by an identical apparatus to that specified on the verification or equivalent if its heat dissipation, once connected, is less than or equal
to the original apparatus.

Legrand offering:

Legrand P17 range equipped units

All of the items in these two product ranges have been modified and verified in order to meet IEC61439-2 and/or IEC61439-3 requirements.

For all of these items, Legrand is classified as both an “original manufacturer” and as an “assembly manufacturer” as per the standard. We remain
at your disposal to provide verifications.

The conditions of use (voltage, currents, ambient temperatures, etc.), assembly and wiring must correspond to the actual use.

Legrand P17 “bespoke” equipped units.

Based on the conditions of installation and use provided by the customer, our teams verify whether the envisaged configuration is eligible for the
target IEC61439-X standard. If this is the case, following the order of the “bespoke” product, our teams will be able to provide the compliance
documents on request.

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 16/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

Legrand P17 range ready-to-assemble units

These units are compatible with the IEC 61439-2 and/or IEC 61439-3 standards.

The compliance of the complete assembly is henceforth obligatorily within the remit of the “assembly manufacturer” (manufacturer finalising
assembly and wiring). The manufacturer of the ready-to-assemble cabinet is not in a position to guarantee compliance, failing knowledge of the
conditions of use and the possibility of carrying out the tests and verifications required by the standard. Hence, the verifications, tests, certificates
and documents to be furnished are the responsibility of the manufacturer finalising the wiring. Therefore, the assembly manufacturer is responsi-
ble for the certification of the complete assembly with its equipment.

In brief: Standard or configured Legrand P17 equipped units suitable for qualifying for IEC61439-X offer installer clients a “ready-to-install” solution
that is “verified, tested, validated as per the standard criteria”. The compliance documents are made available and make reference to the inspec-
tion body once the product is installed and used under the defined conditions.

Normative ambient temperature:


The cabinet is suitable for use in an environment from -5°C to +40°C (with a mean temperature < +35°C over 24 hours)

Overheating verification as per the standard IEC61439-1 + IEC61439-X:


Two types of overheating test are to be carried out: Individual tests and assembly tests
Individual tests:
Each circuit is tested individually at full load. (e.g. a C32 is charged to 32A)

Assembly tests:
The assembly must be tested with each circuit charged to its Rated current multiplied by the RDF coefficient of the cabinet without exceeding the
Total current InA of the unit.
Where:

RDF = Cabinet rated diversity factor.


This factor, the value of which is recommended by the standard but which remains up to the choice of the manufacturer, accounts for the fact that
not all the circuits of an assembly are ever charged to the maximum at the same time. The Legrand range complies with the values recommended
by the standard.
E.g.: IEC61439-2 recommends an RDF of 0.9 between 2 and 3 circuits and an RDF of 0.8 between 4 and 5 circuits

Table 101 – Assumed load values

Type of load Assumed load factor


Table 101 – Assumed load values
Distribution – 2 and 3 circuits 0.9
Number of output circuits Assumed load factor
Distribution – 4 and 5 circuits 0.8
2 and 3 0.8
Distribution – 6 and 9 circuits 0.7
4 and 5 0.7
Distribution – 10 or more cir- 0.6
cuits 6 to 9 inclusive 0.6
Electric controlgear 0.2 10 and over 0.5
Motor 100 kW 0.8
Motors > 100 kW 1.0

IEC 61439-2 IEC 61439-3

InA = Unit rated current


This is the maximum load current of the unit. InA is used to design the protection to be set up at head end.

Overheating:
The standard stipulates maximum overheating levels not to be exceeded, when thermal stabilisation is achieved, on the input terminals, on the
device handles, on accessible surfaces. etc.
Moreover, integrated products (circuit breakers, RCDs, connectors, etc.) must operate under temperature conditions permitted by their reference
standard. Inside the unit, the ambient temperature is greater than its external temperature. Despite this, the products should function correctly.

As regards circuit breakers, the nominal characteristics are dependent on the temperature in their vicinity.
The equipped units have been tested at an external ambient temperature of 20°C, therefore greater inside. The indicated currents account for this.
For other ambient temperature values, it is necessary to refer to the circuit breaker derating chart.
By way of example: derating chart of circuit breaker 4 077 84

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 17/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

Ambient Temperature / In
In (A) - 25°C - 10° C 0 10° C 20° C 30° C 40° C 50° C 60° C 70° C
0,5 A 0,62 0,6 0,57 0,55 0,52 0,5 0,47 0,42 0,40 0,38

1A 1,5 1,4 1,3 1,2 1,1 1 0,9 0,8 0,7 0,6

1,5 A 1,9 1,8 1,7 1,7 1,6 1,5 1,5 1,4 1,4 1,3

2A 2,8 2,6 2,5 2,3 2,2 2 2 1,9 1,8 1,7

3A 3,8 3,6 3,5 3,3 3,2 3 2,9 2,8 2,7 2,6

3,5 A 4,5 4,2 4,0 3,9 3,7 3,5 3,4 3,3 3,2 3,1

5A 6,4 6,0 5,8 5,5 5,3 5,0 4,8 4,7 4,5 4,6

6A 7,5 7,0 6,6 6,4 6,2 6,0 5,8 5,6 5,4 5,3

10 A 12,5 11,5 11,1 10,7 10,3 10,0 9,7 9,3 9,0 8,7

13 A 16,3 15,0 14,3 13,9 13,4 13,0 12,6 12,1 11,7 11,3

16 A 20,0 18,7 18,0 17,3 16,6 16,0 15,4 14,7 14,1 13,5

20 A 25,0 23,2 22,4 21,6 20,8 20,0 19,2 18,4 17,6 16,8

25 A 31,5 29,5 28,3 27,2 26,0 25,0 24,0 22,7 21,7 20,7

30 A 38,3 36,0 34,5 33,0 31,5 30,0 28,8 27,3 26,1 24,9

32 A 41,0 37,8 36,5 34,9 33,3 32,0 30,7 29,1 27,8 26,5

40 A 51,0 48,0 46,0 44,0 42,0 40,0 38,0 36,0 34,0 32,0

50 A 64,0 60,0 57,5 55,0 52,5 50,0 47,5 45,0 42,5 40,0

63 A 80,6 75,6 72,5 69,9 66,1 63,0 59,8 56,1 52,9 49,7

Other tests stipulated by the standard:

Numerous tests and numerous verifications are stipulated in the standard in order to assess product compliance. (IP, Shock, Fire resistance, Di-
electric voltage, Shock voltage, etc.)

All of these tests have been carried out. They confirm the compliance of the various items in the P17 “bespoke” unit range with the IEC61439-1 +
IEC61439-2 standards and for the most part with IEC61439-1 + IEC61439-3.

8.2 Classification of P17 Cat. Nos. in relation to standard 61439

Protection
Rated class: class
Min. connection Protection
Cat. Nos. Voltage Frequency diversity IEC 61439-2 InA IEC 61439-3 InA I or class II
cross-section class
factor (double
(mm2)
(RDF) Insulation)

0 589 20 230V~ 50/60 Hz 2.5 mm2 rigid 0.9 IP 44 YES 16 YES 16


0 589 21 400V~ 50/60 Hz 10 mm2 rigid 0.9 IP 44 YES 40 YES 30
0 589 22 400V~ 50/60 Hz 10 mm2 rigid 0.9 IP 44 YES 32 YES 32
0 589 30 230V~ 50/60 Hz 4 mm2 rigid 1 IP 44 YES 20 YES 20
0 589 31 230V~ 50/60 Hz 4 mm2 rigid 1 IP 44 YES 20 YES 20
0 589 32 400V~ 50/60 Hz 4 mm2 rigid 1 IP 44 YES 20 YES 20
0 589 33 230V~ 50/60 Hz 4 mm2 rigid 1 IP 44 YES 20 YES 20
0 589 34 230V~ 50/60 Hz 4 mm2 rigid 1 IP 44 YES 20 YES 20
0 589 35 400V~ 50/60 Hz 10 mm2 rigid 0.9 IP 44 YES 40 YES 40
0 589 36 400V~ 50/60 Hz 10 mm2 rigid 0.9 IP 44 YES 40 YES 29
0 589 37 230V~ 50/60 Hz 4 mm2 rigid 1 IP 44 YES 20 YES 20

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003

CONTENTS 18/19
P17 combined units Cat. Nos: 0 566 XX - 0 572 XX - 0 577 XX - 0 589 XX

9. ACCESSORIES 9. ACCESSORIES (continued)


9.1 Handles 9.5 Wall mounting lug
Cat. No. 0 019 69
Set of 4 wall mounting lugs
for 265 and 405 mm combined units
Vertical and horizontal mounting

Supplied with lugs to wind the cable for combined unit with:
5 Lexic modules (577 20/589 33): Cat. No. 0 577 37
12 Lexic modules: Cat. No. 0 577 38
18 Lexic modules: Cat. No. 0 577 39

9.2 Key lock


Cat. No. 0 577 35 9.6 Vertical plate mounting kit
Cat. Nos. 0 364 46/47/48/49

0 364 46 0 364 47 0 364 48 0 364 49

0 577 01/03/05 --- --- ---

0 577 02/04/06 --- --- ---

0 577 00/10
0 577 11/20 --- --- ---
For locking the viewing window for optimum safety 0 589 33
0 589 30/31/32
0 589 37/38
--- --- ---
9.3 Emergency stop and emergency break
0 589 40/41
Plates with Osmoz buttons --- --- ---
0 589 42/43
Osmoz emergency stop button
Cat. No. 0 577 40 0 589 50/51/52
0 589 53/54/57
--- ---
For cutting off the power supply to the units
Plate fixed on pre-drilled faceplate
0 598 41 --- --- ---
Supplied in parts ready for assembly
Supplied with push-pull 2 NC contact block
0 598 43 --- --- ---
Osmoz emergency break button
Cat. No. 0 577 45 0 598 46 --- --- ---
For cutting off the power supply to the units
Plate fixed on pre-drilled faceplate 0 589 22/34
Supplied in parts ready for assembly 0 589 35/36 --- --- ---
Supplied with push-pull 1 NO contact blo 0 598 47/48

9.4 IP55 adaptor


Cat. No. 0 539 48
Takes Mosaic mechanisms
2 modules (except special surface mounting type)
No support frame needed

9.7 Tensioner/crimper tool


Cat. No. 0 364 45
Used for tensioning and crimping the cable sleeve

Data sheet: F00140EN/05 Updated: 15/11/2018 Created: 14/12/2003