Power Control Cable
Power Control Cable
108&3$0/530-$"#-&4
26"-*5:3&-*"#*-*5:
/6)"40."/
INTRODUCTION
Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of:
• HV, MV and LV Cables
i8FBU/VIBT0NBODFBTFMFTTMZTUSJWFUP
• Enamelled Copper Wires
• Oxygen Free Continuous Cast Copper Wire Rods
BDIJFWFQSPEVDUFYDFMMFODFUISPVHI • Drawn Copper Conductors
505"-26"-*5:."/"(&.&/5UPQSPWJEF Our state-of-the-art manufacturing facilities with cutting edge technology ensure that our products meet with
highest quality standards. All our products utilize only OXYGEN FREE HIGH CONDUCTIVITY
UIFCFTUWBMVFUPPVSDVTUPNFST*UJTPVS ELECTRONIC GRADE Copper produced through the Outokompu UPCAST technology, producing minimum
99.99% pure copper with oxygen content less than 5 ppm. The usage of /XYGEN &REE (IGH #ONDUCTIVITY #OPPER
NJTTJPOUPQSPEVDFHMPCBMMZDPNQFUJUJWF ENABLES US IN ACHIEVING QUALITY EXCELLENCE
Our range of World-class HV, MV and LV Cables includes Single & Multi Core Armoured and Un-armoured
QSPEVDUTUISPVHIDPOUJOVPVT
Cables, Specialty, Control, Instrumentation and also LSF, FRLS, LSOH & Custom Cables to meet the
requirements of a broad spectrum of applications ranging from 0OWER $ISTRIBUTION )NDUSTRIAL 0ETROCHEMICAL /IL
EFWFMPQNFOUPGQSPEVDUJPODBQBCJMJUJFT 'AS !ERONAUTICAL #ONSTRUCTIONS )NSTRUMENTATION (OSPITALS (OTELS 3ECURITY ETC
TLJMMTFUTBOETJNVMUBOFPVTMZ The Cables are produced in compliance to the requirements of BS, IEC, VDE, ASTM, ICEA & UL
specifications. The #ABLES ARE ROUTINELY TYPE TESTED by acclaimed independent international certifying agencies
DPOUSJCVUJOHUPJOEVTUSJBMBOE confirming compliance to respective standards.
Nuhas IS COMMITTED TO DELIVER QUALITY PRODUCTS that conform to relevant International standards and 1UALITY
FDPOPNJDEFWFMPQNFOUPG0NBOw
ASSURANCE IS THE DRIVING FORCE BEHIND THE #OMPANYS OPERATIONS
/UR 1UALITY -ANAGEMENT 3YSTEM HAS BEEN CERTIlED TO CONFORM TO )3/ BY "!3%# 5+
Our quality cycle encompasses raw material and consumable sourcing, in-process production controls and
certification of finished goods prior to delivery. A well-equipped in-house quality assurance facility, manned by
qualified professionals from the industry, ensures that all products delivered meet stringent quality controls
and parameters. Our state-of-the-art laboratory is equipped to test as per relevant international standards as
also to individual customer specifications.
The company endeavours to cater to the domestic, regional and global markets while maintaining the sanctity
of our pristine environment.
.EW PRODUCT DEVELOPMENT is a continuing process at Nuhas Oman LLC and we at Nuhas Oman ceaselessly
strive to achieve product excellence through TOTAL QUALITY MANAGEMENT to provide the best value to
our customers.
1
TABLE 1
Four Core
10 0.7 0.8 0.9 1.5 17.5 580 35 0.9 1.0 1.6 1.8 28.5 2330
16 0.7 0.8 1.25 1.5 20.0 835 50 1.0 1.0 1.6 1.9 31.5 2940
25 0.9 0.8 1.25 1.6 19.5 995 70 1.1 1.2 2.0 2.1 37.0 4150
Two Core
35 0.9 1.0 1.6 1.7 22.5 1395 95 1.1 1.2 2.0 2.2 40.5 5300
50 1.0 1.0 1.6 1.8 25.5 1735 120 1.2 1.4 2.5 2.3 47.0 6940
70 1.1 1.0 1.6 1.9 28.5 2250 150 1.4 1.4 2.5 2.4 50.0 8170
95 1.1 1.2 2.0 2.0 32.0 3055 185 1.6 1.4 2.5 2.6 55.0 9850
120 1.2 1.2 2.0 2.1 34.5 3635 240 1.7 1.6 2.5 2.7 62.0 12480
150 1.4 1.2 2.0 2.2 38.0 4360 300 1.8 1.6 2.5 2.9 68.0 15100
185 1.6 1.4 2.5 2.4 42.0 5495 400 2.0 1.8 3.15 3.2 78.0 19710
240 1.7 1.4 2.5 2.5 48.5 7000 1.5 0.6 0.8 0.9 1.4 15.5 420
300 1.8 1.6 2.5 2.6 53.0 8450 2.5 0.7 0.8 0.9 1.4 17.0 500
400 2.0 1.6 2.5 2.8 58.5 10335 4 0.7 0.8 1.25 1.5 19.0 700
1.5 0.7 0.8 0.9 1.3 12.5 290 6 0.7 0.8 1.25 1.5 20.5 855
Five Core
2.5 0.7 0.8 0.9 1.4 14.0 350 10 0.7 0.8 1.25 1.6 23.0 1170
4 0.7 0.8 0.9 1.4 15.0 420 16 0.7 1.0 1.6 1.7 26.0 1660
6 0.7 0.8 0.9 1.4 16.0 505 25 0.9 1.0 1.6 1.8 30.0 2285
10 0.7 0.8 1.25 1.5 19.5 800 35 0.9 1.0 1.6 1.9 33.0 2530
16 0.7 0.8 1.25 1.6 21.0 1035 50 1.0 1.2 2.0 2.0 38.5 3920
25 0.9 1.0 1.6 1.7 23.0 1465 70 1.1 1.2 2.0 2.2 43.5 5170
Three Core
2 3
TABLE 2
Four Core
10 1.0 0.8 1.25 1.6 20.0 770 35 1.2 1.0 1.6 1.9 31.0 2520
16 1.0 0.8 1.25 1.6 21.5 935 50 1.4 1.2 2.0 2.0 35.0 3405
25 1.2 1.0 1.6 1.7 22.5 1225 70 1.4 1.2 2.0 2.1 39.0 4375
Two Core
35 1.2 1.0 1.6 1.8 24.5 1515 95 1.6 1.2 2.0 2.2 43.5 5675
50 1.4 1.0 1.6 1.9 28.0 1900 120 1.6 1.4 2.5 2.4 50.0 7305
70 1.4 1.0 1.6 1.9 30.0 2375 150 1.8 1.4 2.5 2.5 53.5 8630
95 1.6 1.2 2.0 2.1 35.0 3300 185 2.0 1.6 2.5 2.6 58.5 10400
120 1.6 1.2 2.0 2.2 37.0 3845 240 2.2 1.6 2.5 2.8 66.0 13130
150 1.8 1.2 2.0 2.3 40.5 4590 300 2.4 1.6 2.5 3.0 72.0 15895
185 2.0 1.4 2.5 2.4 44.0 5765 400 2.6 1.8 3.15 3.3 82.0 20655
240 2.2 1.4 2.5 2.5 51.5 7350 1.5 0.6 0.8 0.9 1.4 14.5 380
300 2.4 1.6 2.5 2.7 56.5 8885 2.5 0.7 0.8 0.9 1.5 16.0 495
400 2.6 1.6 2.5 2.9 62.0 10850 4 0.8 0.8 1.25 1.5 19.0 720
1.5 0.6 0.8 0.9 1.4 12.5 295 6 0.8 0.8 1.25 1.6 20.5 885
Five Core
2.5 0.7 0.8 0.9 1.4 14.0 370 10 1.0 1.0 1.6 1.7 26.0 1450
4 0.8 0.8 0.9 1.4 15.5 465 16 1.0 1.0 1.6 1.7 28.0 1845
6 0.8 0.8 1.25 1.5 18.0 650 25 1.2 1.0 1.6 1.9 32.5 2530
10 1.0 0.8 1.25 1.6 21.0 925 35 1.2 1.0 1.6 1.9 35.0 2750
16 1.0 0.8 1.25 1.6 23.0 1160 50 1.4 1.2 2.0 2.1 41.0 4280
25 1.2 1.0 1.6 1.7 24.5 1595 70 1.4 1.2 2.0 2.2 46.0 5495
Three Core
4 5
TABLE 3
Four Core
35 0.9 1.0 1.6 1.8 27.5 2355
Two Core
Five Core
6 0.7 0.8 0.9 1.4 16.0 515
10 0.7 0.8 1.25 1.5 19.0 815 10 0.7 0.8 1.25 1.6 22.0 1190
16 0.7 0.8 1.25 1.6 21.0 1050 16 0.7 1.0 1.6 1.7 26.0 1680
25 0.9 1.0 1.6 1.7 23.0 1485 25 0.9 1.0 1.6 1.8 30.5 2315
Three Core
35 0.9 1.0 1.6 1.8 25.0 1860 35 0.9 1.0 1.6 1.9 34.0 2560
50 1.0 1.0 1.6 1.8 27.5 2330 50 1.0 1.2 2.0 2.0 39.5 3960
70 1.1 1.0 1.6 1.9 31.5 3055 70 1.1 1.2 2.0 2.2 45.0 5215
95 1.1 1.2 2.0 2.1 36.0 4190
120 1.2 1.2 2.0 2.2 39.5 5085
150 1.4 1.4 2.5 2.3 44.5 6450
185 1.6 1.4 2.5 2.4 48.5 7615
240 1.7 1.4 2.5 2.6 53.5 9595
300 1.8 1.6 2.5 2.7 58.5 11665
400 2.0 1.6 2.5 2.9 65.0 14305
6 7
TABLE 4
Four Core
10 0.7 1.8 15.0 325 35 0.9 1.8 23.5 1530
16 0.7 1.8 16.5 450 50 1.0 1.9 26.0 2030
25 0.9 1.8 16.0 615 70 1.1 2.0 30.5 2840
Two Core
Five Core
2.5 0.7 1.8 11.5 165 10 0.7 1.8 18.5 655
4 0.7 1.8 12.5 220 16 0.7 1.8 20.5 965
6 0.7 1.8 14.0 285 25 0.9 1.8 24.5 1450
10 0.7 1.8 16.0 435 35 0.9 1.8 27.5 1585
16 0.7 1.8 17.5 615 50 1.0 2.0 31.5 2560
25 0.9 1.8 18.0 880 70 1.1 2.1 36.5 3570
Three Core
8 9
TABLE 5
Four Core
10 1.0 1.8 16.5 370 35 1.2 1.8 25.0 1660
16 1.0 1.8 18.0 495 50 1.4 1.9 28.0 2215
25 1.2 1.8 17.0 675 70 1.4 2.1 32.0 3050
35 1.2 1.8 19.0 880 95 1.6 2.2 37.0 4140
Two Core
Five Core
2.5 0.8 1.8 12.0 190 10 1.0 1.8 20.0 745
4 1.0 1.8 14.0 265 16 1.0 1.8 22.0 1065
6 1.0 1.8 15.5 340 25 1.2 1.8 26.5 1595
10 1.0 1.8 17.5 495 35 1.2 1.9 29.0 1730
16 1.0 1.8 19.0 685 50 1.4 2.1 34.0 2805
Three Core
10 11
TABLE 6 TABLE 7
ARMOURED CONTROL CABLES - XLPE INSULATION ARMOURED CONTROL CABLES - PVC INSULATION
Reference standards BS 5467 Applications Reference standards BS 6346 Applications
For installation underground, indoor ducts and For installation underground, indoor ducts and
Construction 1) Oxygen free Electronic in open where mechanical protection is Construction 1) Oxygen free Electronic in open where mechanical protection is
Copper Conductor required or for higher tensile stresses during Copper Conductor required or for higher tensile stresses during
2) XLPE Insulation installation and operation. Suitable for 2) PVC Insulation installation and operation
3) Galvanized steel wire armour comparatively higher operating tenperature 3) Galvanized steel wire armour
4) PVC sheath with XLPE insulation. 4) PVC sheath Technical data
Max. Operating temperature: 70ºC
Technical data
Max. Operating temperature: 90ºC Voltage: 600/1000 V
Voltage: 600/1000 V No. of Area of Thickness of Nom Armour wire Nom Approximate Approximate
cores conductor Insulation thickness of Diameter thickness of overall diameter Cable Weight
No. of Area of Thickness of Nom Armour wire Nom Approximate Approximate bedding oversheath
cores conductor Insulation thickness of Diameter thickness of overall diameter Cable Weight nos mm2 mm mm mm mm mm kg/km
bedding oversheath 7 1.5 0.6 0.8 0.9 1.4 15.0 470
nos mm2 mm mm mm mm mm kg/km 12 1.5 0.6 0.8 1.25 1.5 19.0 815
7 1.5 0.6 0.8 0.9 1.4 15.0 455 19 1.5 0.6 0.8 1.25 1.6 21.5 1100
12 1.5 0.6 0.8 1.25 1.5 19.0 725 27 1.5 0.6 1.0 1.6 1.7 26.0 1625
19 1.5 0.6 0.8 1.25 1.6 21.5 965 37 1.5 0.6 1.0 1.6 1.8 28.5 1910
27 1.5 0.6 1.0 1.6 1.7 26.0 1380 48 1.5 0.6 1.0 1.6 1.9 32.5 2320
37 1.5 0.6 1.0 1.6 1.7 28.5 1675 7 2.5 0.7 0.8 1.25 1.5 17.5 735
48 1.5 0.6 1.0 1.6 1.8 32.0 2080 12 2.5 0.7 0.8 1.25 1.6 22.0 1070
7 2.5 0.7 0.8 0.9 1.4 16.5 590 19 2.5 0.7 1.0 1.6 1.7 26.0 1625
12 2.5 0.7 0.8 1.25 1.6 22.0 965 27 2.5 0.7 1.0 1.6 1.8 30.0 2080
19 2.5 0.7 1.0 1.6 1.7 26.0 1465 37 2.5 0.7 1.0 1.6 1.9 33.5 2645
27 2.5 0.7 1.0 1.6 1.8 30.0 1845 48 2.5 0.7 1.2 2.0 2.1 39.0 3495
37 2.5 0.7 1.0 1.6 1.8 33.0 2275 7 4.0 0.8 0.8 1.25 1.6 20.0 920
48 2.5 0.7 1.2 2.0 2.0 38.5 3080 12 4.0 0.8 1.0 1.6 1.7 26.5 1555
7 4.0 0.7 0.8 1.25 1.5 19.5 850 19 4.0 0.8 1.0 1.6 1.8 30.0 2035
12 4.0 0.7 1.0 1.6 1.6 25.0 1405 27 4.0 0.8 1.2 2.0 2.0 36.5 2995
19 4.0 0.7 1.0 1.6 1.7 29.0 1850 37 4.0 0.8 1.2 2.0 2.1 40.0 3690
27 4.0 0.7 1.0 1.6 1.9 34.0 2385 48 4.0 0.8 1.2 2.0 2.2 45.5 4495
37 4.0 0.7 1.2 2.0 2.0 38.5 3360
48 4.0 0.7 1.2 2.0 2.1 43.5 4053
12 13
TABLE 9
14 15
TABLE 10
16 17
TABLE 12
Maximum resistance of armour for single and multicore XLPE insulated 600/1000 V cables
having aluminium and steel wire armour
TABLE 13
18
TECHNICAL DATA
POWER CABLES - CURRENT RATINGS
The data provided are for guidance only Nuhas reserve the rights to edit/modify
any or whole of the data as a part of their effort of continuous Reaserch & Development
21
POWER CABLES - CURRENT RATINGS POWER CABLES - CURRENT RATINGS
Current ratings and Voltage drop of two core cables Current ratings and Voltage drop of three and four core cables
Copper conductor, XLPE insulated armoured/unarmoured cable Copper conductor, XLPE insulated armoured/unarmoured cable
Nominal AC Current Ratings in Amp Approximate Voltage Drop Nominal AC Current Ratings in Amp Approximate Voltage Drop
conductor conductor
area In Ground In Duct In Air In Ground In Duct In Air area In Ground In Duct In Air In Ground In Duct In Air
mm2 ARMRD ARMRD UNARM ARMRD mV/A/m mV/A/m mV/A/m mm2 ARMRD ARMRD UNARM ARMRD mV/A/m mV/A/m mV/A/m
1.5 33 27 23 26 31 31 31 1.5 28 22 20 22 27 27 27
2.5 42 35 32 34 19 19 19 2.5 36 29 29 29 16 16 16
4 56 46 42 46 12 12 12 4 47 39 36 39 10 10 10
6 70 58 54 58 7.9 7.9 7.9 6 59 48 47 49 6.8 6.8 6.8
10 94 77 71 79 4.7 4.7 4.7 10 79 65 61 68 4 4 4
16 121 99 103 105 2.91 2.89 2.89 16 102 83 89 89 2.5 2.5 2.5
25 157 127 129 136 1.91 1.89 1.89 25 131 107 111 116 1.71 1.69 1.69
35 188 153 160 168 1.31 1.29 1.29 35 157 128 137 143 1.21 1.19 1.19
50 223 181 195 203 1.01 0.99 0.99 50 187 152 167 173 0.91 0.89 0.89
70 273 224 247 254 0.71 0.69 0.69 70 229 187 212 218 0.61 0.59 0.59
95 328 269 305 314 0.51 0.49 0.49 95 274 226 262 269 0.51 0.49 0.49
120 372 307 356 363 0.41 0.39 0.39 120 312 258 306 312 0.41 0.39 0.39
150 417 345 408 414 0.41 0.39 0.39 150 349 291 351 357 0.31 0.29 0.29
185 470 391 472 478 0.31 0.29 0.29 185 394 329 406 411 0.31 0.29 0.29
240 544 453 563 564 0.21 0.19 0.19 240 455 380 483 485 0.21 0.19 0.19
300 609 509 650 643 0.21 0.19 0.19 300 509 427 558 553 0.21 0.19 0.19
400 687 575 756 740 0.20 0.18 0.18 400 574 490 647 636 0.21 0.19 0.19
In Ground Direct in ground in trefoil touching In Ground Direct in ground in trefoil touching
In Duct Single way ducts touching In Duct Single way ducts touching
In Air Spacing 3 x cable diameter In Air Spacing 3 x cable diameter
Installation Conditions considered for Current ratings Installation Conditions considered for Current ratings
Ground Temperature : 35ºC Ground Temperature : 35ºC
Ambient air temperature : 45ºC Ambient air temperature : 45ºC
Depth of laying : 0.50m Depth of laying : 0.50m
Soil thermal Resistivity : 1.20Cm/W Soil thermal Resistivity : 1.20Cm/W
Max. permissible operating temperature at rated current: 90ºC Max permissible operating temperature at rated current: 90ºC
Note: for other installation conditions please refer appropriate rating factors Note: for other installation conditions please refer appropriate rating factors
The data provided are for guidance only Nuhas reserve the rights to edit/modify The data provided are for guidance only Nuhas reserve the rights to edit/modify
any or whole of the data as a part of their effort of continuous Reaserch & Development any or whole of the data as a part of their effort of continuous Reaserch & Development
22 23
RATING FACTORS
Where the conditions of installation are differes from those defined
in the Current rating tables, the following rating factors may be used to
determine the data for actual installation conditions
Copper conductor, XLPE insulated armoured/unarmoured cable Cable Type Cross Linked Polyethelyne (XLPE) insulated
Rating Factors 1.20 1.16 1.13 1.08 1.03 1.00 0.95
Nominal AC Current Ratings in Amp Approximate Voltage Drop
conductor
area In Ground In Duct In Air In Ground In Duct In Air Rating Factors for variation in thermal resistivity of Soil
mm2 ARMRD ARMRD UNARM ARMRD mV/A/m mV/A/m mV/A/m Size of Cable in mm2 Soil Thermal Reststivity in c-m/W
1.5 28 22 20 22 27 27 27
2.5 36 29 29 29 16 16 16 0.8 0.9 1.0 1.2 1.5 2.0 2.5
4 47 39 36 39 10 10 10 Single Core Cables
6 59 48 47 49 6.8 6.8 6.8
10 79 65 61 68 4 4 4 Up to 150 1.16 1.12 1.07 1.00 0.91 0.81 0.73
16 102 83 89 89 2.5 2.5 2.5
from 185 to 300 1.17 1.12 1.07 1.00 0.91 0.80 0.73
25 131 107 111 116 1.71 1.69 1.69
35 157 128 137 143 1.21 1.19 1.19 from 300 to 1000 1.17 1.12 1.07 1.00 0.91 0.80 0.73
50 187 152 167 173 0.91 0.89 0.89
70 229 187 212 218 0.61 0.59 0.59 Multi Core Cables
Up to 16 1.12 1.08 1.05 1.00 0.93 0.84 0.77
from 25 to 150 1.14 1.10 1.06 1.00 0.92 0.82 0.75
In Ground Direct in ground in trefoil touching
In Duct Single way ducts touching from 185 to 400 1.15 1.10 1.07 1.00 0.92 0.81 0.74
In Air Spacing 3 x cable diameter
Rating factors for Depth of Laying ( to centre of the cable or Trefoil group of cable )
Installation Conditions considered for Current ratings
Ground Temperature : 35ºC 600/1000 Volt
Depth of Laying in m
Ambient air temperature : 45ºC Upto 50 mm2 from 70 to 300 mm2 400 mm2 and above
Depth of laying : 0.50m
Soil thermal Resistivity : 1.20Cm/W 0.50 1.00 1.00 1.00
Max permissible operating temperature at rated current: 90ºC 0.60 0.99 0.98 0.97
Note: for other installation conditions please refer appropriate rating factors
0.80 0.97 0.96 0.94
The data provided are for guidance only Nuhas reserve the rights to edit/modify 1.00 0.95 0.93 0.92
any or whole of the data as a part of their effort of continuous Reaserch & Development
1.25 0.94 0.92 0.89
1.50 0.93 0.90 0.87
1.75 0.92 0.89 0.86
2.00 0.91 0.88 0.85
2.50 0.90 0.87 0.84
3.00 or more 0.89 0.85 0.82
24 25
Group Rating Factors for Circuits of three single core cables in trefoil flat touching, in horizontal formation
up to and including 65 mm 100 130 Group Rating factors for multicore cables in single way ducts, horizontal formation ( average value)
above 65 & up to and including 90 mm 125 168
Number of Spaced by in m
Rating factors for variation in ground temperature for cables laid in ducts ducts in ground Touching 0.30 0.45 0.60
Ground Temperature 10ºC 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 2 0.9 0.93 0.95 0.96
Cable Type Cross Linked Polyethelyne (XLPE) insulated 3 0.83 0.88 0.91 0.93
Rating Factors 1.20 1.16 1.13 1.08 1.03 1.00 0.95 4 0.79 0.85 0.89 0.92
5 0.75 0.83 0.88 0.91
Rating Factors for variation in thermal resistivity of Soil 6 0.73 0.82 0.87 0.90
Size of Cable in mm2 Soil Thermal Reststivity in C-m/W
0.8 0.9 1.0 1.2 1.5 2.0 2.5 CABLE INSTALLED IN AIR
Single Core Cables Rating factors for variation in ground temperature for cables laid in ducts
Up to 150 1.10 1.07 1.04 1.00 0.94 0.86 0.80 Air temperature 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC
from 185 to 300 1.11 1.08 1.05 1.00 0.93 0.85 0.79 Cable Type Cross Linked Polyethelyne (XLPE) insulated
from 300 to 1000 1.12 1.08 1.05 1.00 0.93 0.84 0.78 Rating factor 1.20 1.16 1.11 1.06 1.00 0.94 0.88
Multi Core Cables
Up to 16 1.04 1.03 1.02 1.00 0.97 0.92 0.88
from 25 to 150 1.06 1.04 1.03 1.00 0.95 0.90 0.85
from 185 to 400 1.07 1.05 1.03 1.00 0.95 0.88 0.83
26 27
SHORT CIRCUIT CURRENT CHART OF COPPER CONDUCTOR,
XLPE INSULATED 600/1000 V CABLES
, "
*TD
5
MPHF
ƿƿ G
ƹ
ƹ 1000.00
XIFSF
*TDTIPSUDLUDVSSFOU ,"
5 TIPSUDLUEVSBUJPO 4FD
, DPOTUBOUGPSDPQQFS
" DSPTTTFDUJPOBMBSFB NN
ƿG mOBMUFNQFSBUVSF $ 100.00
ƿ JOJUJBMUFNQFSBUVSF $ 1000.0
ƹ SFDJQSPDBMPGSFTJTUBODFUFNQFSBUVSFDPFöDJFOU GPSDPQQFS 800.0
NO/TECH/SCCR/XLPE/MDPB/2010
0.01
0.01 0.1 1 10
Duration of Short Circuit in sec
28 29
30 31
32
/6)"40."/--$
10#PY 1PTUBM$PEF
3VTBZM*OEVTUSJBM&TUBUF 4VMUBOBUFPG0NBO
5FM 'BY
&NBJMNBSLFUJOH!OVIBTPNBODPN8FCTJUFXXXOVIBTPNBODPN
".FNCFSPGUIF"M#BIKB(SPVQ
"/*40$0.1"/:
/6.,5%#+3FW
%BUF