0% found this document useful (0 votes)
84 views

S65 Instruction Manual EN V2.10

Uploaded by

5nw6hf8xdf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
84 views

S65 Instruction Manual EN V2.10

Uploaded by

5nw6hf8xdf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 28
SKYRC S65 AC Balance Charger / Discharger Instruction Manual ©SkyRC Technology Co., Ltd. 2022 Version 2.1 TABLE OF CONTENTS INTRODUCTION .....- SPECIAL FEATURES WARNING AND SAFETY NOTES .....-------------2222202200eeeeeeeeeeeeeeeeeeeeeeee 05 PROGRAM FLOW CHART .....-.----..-------------- +--+ 2-225 -2 22 22 ee eee eee 08 OPERATION... ..-..---- 2-0-2222 20 022 2c eee cece ec eee cece ee eee eee e eect ee ee eee --09 OPERATING PROGRAM.......--- BATTERY MEMORY SET AND CALL OUT SYSTEM SETTING ......--- - 16 BATTERY METER BATTERY RESISTANCE METER ...-.----.-------- 022222000220 2eeeceeeeeee cee eee ---19 WARNING AND ERROR MESSAGE THE SET CONTAINS .......-..------2- 022222202 0ee cece cece ee eect eects eet eee ee eee 21 SPECIFICATION, CONFORMITY DECLARATION ...........-...22222000022eeeeeeeeeeeeeeeeeees --23 COMMONLY USED TERMS ........---------------2-222 2222 eee cece eee ee eee -- 24 WARRANTY AND SERVICE .. 2.25 INTRODUCTION Congratulations on your choice of SKYRC S65 AC Input Professional Balance Charger/Discharger. This unit is simple to use, but the operation of a sophisticated automatic charger such as SKYRC S65 does require some knowledge on the part of the user. These operating instructions are designed to ensure that you quickly become familiar with its functions. It is therefore important that you read right through the Operating Instructions, Warning and Safety Notes before you attempt to use your new charger for the first time. We hope you have many years of pleasure and success with your new battery charger. SkyRC S65 is an AC input charger/discharger with compact size (117x105x55mm). Like most SkyRC chargers, it supports TVC (Terminal Voltage Control), Battery Meter. And there are Automatic Charging Current Limit, Capacity Limit, Temperature Threshold and Processing Time Limit for maximum safety. The maximum charging power of S65 is 65W with maximum charging current 6A and discharging current 2A. It is a high-performance micro processor control charge/discharge station with battery management suitable for use with all current battery types, LiPo, Lilon, LiFe, NiCd, NiHM, PB and also new generation LiHV with end voltage 4.35V. For PB battery, S65 adds AGM and cold charge modes. It can charge AGM battery, and Pb battery can be charged in cold charge mode in cold days. Please BE SURE to read these INSTRUCTIONS, WARNING and SAFETY NOTES before you use the charger for the first time. It can be dangerous to mis-handle batteries and battery chargers, as there is always a risk of batteries catching fire and exploding. S65 01 INTRODUCTION Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety. Or please do use this product in company with a specialist! AC Input Scroll Through the Main Menu Power Port Stop Any Charge Processes < AC 100-240V Alter Values Mb. ve See the Status of 2 Individual Cells in “P= ¢ 2S SY Balance Charge Mode LCD Display Smart Ventilation Balance Lead Fan Socket JST-XH _Sé P ons Resume or Start y Charge Processes Battery Connector a Confirm Any Acti (XT60 Female) ‘onfirm Any Action Temperature Sensor Port 02 S65 SPECIAL FEATURES Optimized Operating Software SkyRC S65 features the so-called AUTO function that set the feeding current during the process of charging or discharging. Especially for lithium batteries, it can prevent the overcharging which may lead to an explosion due to the user's fault. It can disconnect the circuit automatically and alarm once detecting any malfunction. All the programs of this product were controlled through two way linkage and communication, to achieve the maximum safety and minimize the trouble. All the settings can be configured by users! Battery Memory (Data Store/Load) The charger can store up to 10 different charge/discharge profiles for your convenience. You can keep the data pertaining to program setting of the battery of continuous charging or discharging. Users can call out these data at any time without any special program setting. PB AGM and Cold Charge For PB battery, S65 adds AGM and cold charge modes. It can charge AGM battery, and Pb battery can be charged in cold charge mode in cold days. Terminal Voltage Control(TVC) The charger allows user to change the end voltage. (for expert user only) Internal Independent Lithium Battery Balancer SkyRC S65 employs an individual-cell-voltage balancer. It isn't necessary to connect an external balancer for balance charging. Balancing Individual Cells Battery Discharging During the process of discharging, SkyRC S65 can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal. Adaptable to Various Type of Lithium Battery SkyRC S65 is adaptable to various types of lithium batteries, such as LiPo, Lilon, LiFe and the new LiHV batteries. Fast and Storage Mode of Lithium Battery Purposes to charge lithium battery varies, ‘fast’ charge reduce the duration of charging, whereas ‘store’ state can control the final voltage of your battery, so as to store for a long time and protect useful time of the battery. S65 03 SPECIAL FEATURES Re-Peak Mode of NiMH/NiCd Battery In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row automatically. This is good for making certain the battery is fully charged Delta-peak Sensitivity for NIMH/NiCd Delta-peak sensitivity for NiMH/NiCd battery: The automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process will be terminated automatically. Cyclic Charging/Discharging 1 to 5 cyclic and continuous process of charge > discharge or discharge > charge is operable for battery refreshing and balancing to stimulate the battery's activity. Automatic Charging Current Limit You can set up the upper limit of the charging current when charging your NiMH or NiCd battery, it is useful for the NiMH battery of low impedance and capacity in the ‘AUTO! charging mode. Battery Meter The user can check battery voltage and battery internal resistance. Capacity Limit The charging capacity is always calculated as the charging current multiplied by time. If the charging capacity exceeds the limit, the process will be terminated automatically when you set the maximum value. Temperature Threshold* The battery's internal chemical reaction will cause the temperature of the battery to rise. If the temperature limit is reached, the process will be terminated. * This function is available by connecting optional temperature probe, which is not included in the package. Processing Time Limit: You can also limit the maximum process time to avoid any possible defect. 04 S65 WARNING AND SAFETY NOTES These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire. @ Never leave the charger unattended when it is connected to its power supply. If any malfunction is found, TERMINATE THE PROCESS AT ONCE and refer to the operation manual. @ Keep the charger well away from dust, damp, rain, heat, direct sunshine and vibration. Never drop it. © The allowable AC input voltage is 100~240V AC @ This charger and the battery should be put on a heat-resistant, noninflammable and nonconductive surface. Never place them on a car seat, carpet or similar. Keep all the inflammable volatile materials away from operating area @ Make sure you know the specifications of the battery to be charged or discharged to ensure it meets the requirements of this charger. If the program is set up incorrectly, the battery and charger may be damaged .It can cause fire or explosion due to overcharging. Standard Battery Parameters er et) Nominal Nareers 3.7Vicell |3.6Vicell |3.3V/cell |3.7Vicell |1.2V/cell |1.2V/cell_|2.0V/cell ee 4.2Vicell |4.1Vicell |3.6Vicell |4.35Vicell 1 5V/cell | 1.5Vicel_ |2.46Vicell Beer RosTeery 3.8Vicell /3.7Vicell |3.3V/cell_ /3.85Vicell nla nia Os Fast Charge fila =1C =4C =1C 1c-2C |ic-2c =| =0.4C eee 303.3Vicel |29-3.2Vicell | 26-2 9Vicel|3.1-3.4V/cel|0.1-1.4Vicel | 0.1-1.1Vicel | 4.8V/cell Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries. Incorrect settings could cause the cells to fire or explode. S65 05 WARNING AND SAFETY NOTES @ Never attempt to charge or discharge the following types of batteries. A battery pack which consists of different types of cells (including different manufacturers) Abattery that is already fully charged or just slightly discharged. Non-rechargeable batteries (Explosion hazard). Batteries that require a different charge technique from NiCd, NiMh, LiPo or Gel cell (Pb, Lead acid). A faulty or damaged battery. Abattery fitted with an integral charge circuit or a protection circuit. Batteries installed in a device or which are electrically linked to other components. Batteries that are not expressly stated by the manufacturer to be suitable for the currents the charger delivers during the charge process. @ Please bear in mind the following points before commencing charging: Did you select the appropriate program suitable for the type of battery you are charging? Did you set up adequate current for charging or discharging? Have you checked the battery voltage? Lithium battery packs can be wired in parallel and in series, ie. a 2 cell pack can be 3.7V (in parallel) or 7.4V (in series). Have you checked that all connections are firm and secure? Make sure there are no intermittent contacts at any point in the circuit. @ Charging During charge process, a specific quantity of electrical energy is fed into the battery. The charge quantity is calculated by multiplying charge current by charge time. The maximum permissible charge current varies depending on the battery type or its performance, and can be found in the information by the battery manufacturer. Only batteries that are expressly stated to be capable of quick- charge are allowed to be charged at rates higher than the standard charge current. Connect the battery to the terminal of the charger: red is positive and black is negative. Due to the difference between resistance of cable and connector, the charger can not detect resistance of the battery pack, the essential requirement for the charger to work properly is that the charge lead should be of adequate conductor cross-section, and high quality connectors which are normally gold- plated should be fitted to both ends. Always refer to the manual by battery manufacturer about charging methods, recommended charging current and charging time. Especially, the lithium battery should be charged according the charging instruction provided by the manufacturer strictly. 06 S65 WARNING AND SAFETY NOTES Attention should be paid to the connection of lithium battery especially, Do not attempt to disassemble the battery pack arbitrarily. Please get highlighted that lithium battery packs can be wired in parallel and in series. In the parallel connection, the battery s capacity is calculated by multiplying single battery capacity by the number of cells with total voltage stay the same. The voltages imbalance may cause fire or explosion Lithium battery is recommended to charge in series. @ Discharging The main purpose of discharging is to clean residual capacity of the battery, or to reduce the battery voltage to a defined level. The same attention should be paid to the discharging process as charging. The final discharge voltage should be set up correctly to avoid deep-discharging. Lithium battery can not be discharged to lower than the minimum voltage, or it will cause a rapid loss of capacity or a total failure. Generally, lithium battery doesn’ t need to be discharged. Please pay attention to the minimum voltage of lithium battery to protect the battery. Some rechargeable batteries have a memory effect. If they are partly used and recharged before the whole charge is accomplished, they remember this and will only use that part of their capacity next time. This is a memory effect. It is said that NiCd and NiMH batteries are suffering from memory effect. NiCd has more memory effect than NiMH. S65 07 PROGRAM FLOW CHART TATTPROGN—] 8 [TPS RMCECRS |p [TPOOARE x, [TPOTISTOUREE | ce, TPO STONNEE— |, [POSTURE pasar SS [sPfzen raves) FPfacn ravasy Peep zen raves, [Plan raves) The Sy BarTPROGRN | TF jes [rena Jec,| iresToRcE 5 [FeOSOARE eeaaT |S] 204 savzs) | P|z08 5725) sla eves) |ePlzon saves) eb OO TATTPROGRAT | P55 TEBLANCEOTS |, [TsCRARGE |], [TDSTOOAGE |<, ToSTORAGE | =, oDROUROE aos JSS] 200 raves) AP fzo raves) [Pz raves) [APfzo raves) SP fans 72005) eee x Gn aTTPROGRaN | 93 THVEAANGE CRO] gs, [TRVGHARGE |], [RV FSTOPARGE |, [TAVSTORNGE |, [UMVDROHORGE iBveerr|S| 208 Tavis) |S [zox raves) [P20 raves) [AP] 208 Teves) eax raves) hes A TATTPROGEAT TARE 15 MMT OURGE | pe WMOSOIGE | ge [MM REPER | TnOr sare [S| curser 200 ‘flow oni Jt? + HP Loses ede & a TarTPROGN |g Woscumnce gs, [Noummounce | gr[wososcmact ]os | NconEPER |<. noscaLE wcobart |SSL_ commer 20a |*P]cuncenr 2a |*t[om conic +P Loweses ae Zz z TarTPRoGRN |p| PENONULGRS os [PoAGUGRO x, [Poooone |, [PPOSOURCE Seas S| 28 20 Phosa zoe, [Porm zor Pfam zovie) BaTTPRoGRIN acy NAN 000 (Connect the main battery socket) sarrweren | Dav Leg TNT] ¢c, ‘onnect battery via balance board) nwa JPL sooo nome Earemocm |g S130 na gs [ TO. ine paraesstince || 5235 mo | TATTPROGRT Tay Tr ]e,| Cosy rot 1 Tarp cn OF], Toone om 1% [Fase || a Senay SYSTEMSETIING? [S=PLon caoue)SPLon toons]? [ONY sore tax Jt ‘aks [EP] cHo>90H6 son [SPL open Dat Tse apis Fata SE gS Sateen os [earteae OF] gS [NCE Sai ee hsao_seetoo | er [SP eum on |“SP|_oFea “Ovt TaTTPROGRI | TAT MEMORY 1] 535 [EAT IVE ETO 5 f |e, TORRENT >|_sarrwenony [Set] ewerser> |SPluo 15) alte 22 seveniseosy [TENTWEIORTT Tg [TET HERON NE PROGRAM |g [ ONO pee 222k Le Tavs). eve |S? aN ENTER CURGER |, [TPOEALINCEOHS |, [Pe RCE], [TPO TSTORREE ge, TPO STOREE—], TPOUREIRSE Low Placa tavps) [SP [ask raves PPL ek 7 PL ca raasy [EPL zak ras) sons TERTT MENT 2] [ENTE [ys [RATIONS Lf TRORLE || FEADELAT aa [ENTERS rit rs zavesi [te om | ‘Mn [EAT WEVORT? J],_[TSATTNEWORTE PRON |g SHE PROGEN_[% [DSOHVOURGE 5 [ DSOH CURRENT Gian D10N hw 24 28) * even ‘voeu) 2h + EATER CHRGER |. [NORORCE — 9, [ine COAT], [NG OSCERRCE |g, UE REPER—] pM Lou PlousnexT won| [cursen zat] os curzov 2 SP Laoioas sy TERT MENT aT]=S[ENTPE [ge [EATVONS— |. [CRC CURRENT], DSONCURRENT 14%, | oo ewrenser> |SS|_ © over) salt? tals TEORULOS |p, (EWTERCMRGER | TEATHENORTS]],_[TRTWETORTS |, [SNEPROGRAT — | [SRE PROGRAN row 20%) JP |Lom essa Dik poses) [swe hed ENTER t TREE ee PoaBICHS | gx [REDDER |, [POOREANRGE axa cove, [Pfam zoviey [SP fora 200061 08 S65 OPERATION BATT/PROG DEC INC ENTER O88 Stop < STATUS > Start BATT PROG / STOP Button: It is used to stop the progress or go back to previous step/screen DEC Button: It is used to go through the menus and decrease the parameter value INC Button: It is used to go through the menus and increase the parameter value ENTER / START Button: Itis used to enter parameter or store parameter on screen When you are willing to alter the parameter value in the program, press the START/ENTER button to make it blink then change the value by pressing DEC and INC button. The value will be stored by re-pressing the START/ENTER button. If there is another parameter can be altered in the same screen, when you confirm the first parameter value, the next parameter value will start to blink which means it is ready to alert. When you are willing to start the progress, press and hold the START/ENTER button for 3 seconds. When you are willing to stop the progress or go back to previous step/screen, press the BATT PROG/STOP button once. When you power on the charger, it will enter LiPo Battery balance program directly. You could change the mode (balance mode, normal charge mode, fast charge mode, store mode or discharge mode), enter the desired charging/discharging mode, set the referred parameter and start the progress. If you have no request for LiPo Battery program, please press the BATT PROG/STOP button to enter BATT PROGRAM screen. S65 09 OPERATING PROGRAM Here is the detailed procedure to make the charger work. All the screens and operations will take Li-Po BALANCE CHARGE program for example, 1. Connection 1), Connecting to power source 2) 3 It is an AC charger only. Please insert the AC power cord to the wall socket (100-240V) directly to power it on Connecting the battery Important!!! Before connecting a battery it is absolutely essential to check one last time that you have set the parameters correctly. If the settings are incorrect, the battery may be damaged, and could even burst into flames or explode. To avoid short circuits between the banana plugs, always connect the charge leads to the charger first, and only then to the battery. Reverse the sequence when disconnecting the pack. Balance Charge In Balance Charge Mode, the balance wire attached to the battery must be connected to the balance socket in front of the charger;the XT60 male connector is connected to the XT60 female connector in the charger(See the wiring diagram below). In the other modes, there is no request to connect the balance wire to the balance socket in the charger. But we suggest to charge your battery in balance mode for better performance. WARNING: Failure to connect as shown in this diagram will damage this charger. To avoid short circuit between the charge lead always connect the charge cable to the charger first, then connect the battery. Reverse the sequence when disconnecting S65 OPERATING PROGRAM n . Getting started Locate the flowcharts show the entire programming menu. It is highly recommended to have these flowcharts handy while learning to operate this charger. There are two main ways in which to set the charger. (1)A memory profile is available for setting and storing pertinent information for up to 10 different batteries. Once a battery's information is stored into a memory it will be retained until changed again manually, Recalling a battery's memory number makes the charger instantly ready to go! (2) If you do not wish to use the battery memories, this charger can be manually set before each use. For following step, all are basing on manually set 3. BATT/PROGRAM Select Press INC and DEC to go through all the programs and press START/ENTER to enter LiPo BATT Program. 4. Mode Select Press INC and DEC to go through all the modes and press START/ENTER to enter LiPo Balance Charge Mode. a . Battery Setting Press START/ENTER, the current value will start to blink, press INC and DEC to change the value and press START/ENTER to confirm your setting. At the same time, the battery cells number will start to blink, press INC and DEC to change the value and press START/ENTER to confirm your setting. Program Start Press and hold START/ENTER for 3 seconds to start the START/ENTER program. > 3 Seconds 2 The charger is detecting the battery cell. R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen. If both numbers are not identical, press STOP to go back to previous screen to recheck the number of cells of the battery pack before going ahead. S65 " OPERATING PROGRAM R shows the number of cells detected by the charger and S is the number of cells set by you at the previous screen. If both numbers are identical, press START/ENTER to start charging process. 7. Charging Status Monitor During charge process, real-time status will be showed as left screen START/ENTER VARIOUS INFORMATION DURING THE PROCESS Press INC or DEC during charging or discharging process, you can inquire various information on LCD screen . Real-time status: battery type, battery cell, charge current, battery voltage, elapsed time and charged capacity Voltage of each cell in the battery pack when the battery is connected with balance lead. Charged capacity percentage and average cell voltage of the battery pack. Resistance of each cell in the battery pack when the battery is connected with balance lead. Final voltage when the program ends. Internal temperature. ‘Temperature probe is needed to show external temperature. Cut off temperature Safety timer ON and duration of time in minutes. Capacity cut-off ON and the setting value of capacity. S65 8. Program Stop During the charging process, press STOP to stop the charging process. 9. Program Complete OPERATING PROGRAM When the charging process finishes, an audible sound will be heard. Charging Program Depends on different battery type, the operation programs are different. Eee een mead a aac) P CHARGE ‘This charging mode is for charging LiPo/LiHV/LiFe/Lilon battery in normal mode. DISCHARGE _| This mode is for cischarging LiPo IHVILiFe/Lilon battery. ee ere el STORAGE | used foriong time. ene 7 LiPo LiKV ‘The charging capacity may be a bit smaller than normal charging but the Lilon | FAST CHG process time will be reduced. LiFe This mode efor balancing the vollage of itiur:-polymerbatary cal while BAL CHARGE | charging, ° " " ” “The charger will charge NIMH and NiGi batteries using the charge eurent CHARGE ‘set by the user. In this program the charger detects the condition of the battery which is Connocted fo the output and automatically charges the bation auTO CHG | Note: you should set up the upper limit ofthe charge current to avoid damage by excessive feeding current, Some batteries of ow resistance and capacity can lead to higher current. NiMH [DISCHARGE _| This mode is for discharging NIMINICA battery In te-peak charge mode, the charger can peak charge the battery once, reepeax | te or three times in arow automaticaly. Tiss good for conning the battery is fully charged, and for checking how well the battery receives fast charges 1 to 5 eye and continuous process of charge>diacharge or cycle Ksecharge=haraeli operate forbat exit nane balance stimulate the batten’ activi NORMAL CHG _| This mode is for charging Pb battery TAGMCHG | This mode is for charging AGM battery Pb caiwens | MSmede|storcharang Po baer in cold aye when he temperate i DISCHARGE _| This mode is for discharging Pb batory. S65 13 BATTERY MEMORY SET AND CALL OUT The charger can store up to 10 different charge/discharge profiles for your convenience, and the stored profiles can be recalled quickly without having to go through the setup process. When you are willing to alter the parameter value in the program, press START/ENTER to make it blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER once. Note: All following screen are taking 2S(7.4V) LiPo battery for example. 1. Battery Memory Set Enter the battery memory program. a Eig (10 different charge/discharge profiles can be stored). START/ENTER Set the battery type(LiPo/LiHV/LiFe/Lilon/NiMHI/NiCd/Pb). sec] mor Set the voltage and number of cells(2S-4S). Set the charge current(0.1-6.0A). Set the discharge current (0.1A-2.0A). Set the discharge voltage(3.0-3.3V/Cell) DEC} INC Set the terminal voltage(4.18-4.25V). doec] ne Press ENTER to save program BATTERY MEMORY SET AND CALL OUT Indicate the battery type and battery cell of the saved profile Indicate the charge and discharge current of the saved profile. Press the START/ENTER for 3 seconds to call out the memory. START/ENTER >3 Seconds 2. Battery Memory Call Out Load the memory set Press START/ENTER for 3 seconds to start the process. S65 15 SYSTEM SETTING It will be operated with the default value of the essential user settings when it is powered on for the first time.The screen displays the following information in sequence and the user can change the value of parameter on each screen. When you are willing to alter the parameter value in the program, press START/ENTER to make it blink then change the value with INC or DEC. The value will be stored by pressing START/ENTER once. ITEM SELECTION DESCRIPTION OFF/ ON (1-720 Min) When you start a charge process, the integral safety timer automatically starts running at the same time. This is programmed to prevent overcharge the battery if it proves to be faulty, or if the termination circuit cannot detect the battery full. The value for the safety timer should be generous enough to allow a full charge of the battery. OFF/ ON (100-5000 mAh) This program sets the maximum charge capacity that will be supplied to the battery during charge. If the delta peak voltage is not detected nor the safety timer expired by any reason, this feature will automatically stop the process at the selected capacity value. OFF/ The battery's internal chemical reaction ON will cause the temperature of the battery (20°C/68°F - to rise. If the temperature limit is reached, 80°C/176°F) the process will be terminated. Celsi You can choose the temperature Fahvenh 7 displayed by Celsius or Fahrenheit as ahrenheit you like A rest time allowing the battery to cool 1-60Min down between charging/discharging cycle. 16 S65 SYSTEM SETTING SELECTION DESCRIPTION Default: 4mV/Cell This program is for NiMH/NiCd battery only. When the charger detects the delta peak value reaches the value you set, the 3-15mV/Cell charger will say the battery is fully charged. The beep sounds at every time touching the buttons to confirm your action. The OFF/ON beep or melody sounded at various times during operation to alert different mode changes. Press ENTER to load factory default setting It indicates the hardware and firmware version, S65 7 BATTERY METER The user can check battery's total voltage, the highest voltage, the lowest voltage and each cell's voltage. Please connect the balance wire attached to the battery to the balance socket and the XT60 male connector to the XT60 female connector in front of the charger. This diagram shows the correct way to connect your battery to check the voltage. Battery Pack GEGEN Press the START/ENTER to enter the Lithium Battery EAM) Meter program. The screen indicate each cell's voltage. The screen indicate the total voltage, the highest voltage and the lowest voltage. BATTERY RESISTANCE METER The user can check battery's total resistance, the highest resistance, the lowest resistance and each cell's resistance. Please connect the balance wire attached to the battery to the balance socket and the XT60 male connector to the XT60 female connector in front of the charger. ($65 etre») E- ay This diagram shows the correct way to connect your battery to check the resistance. Tlie e144 Press the START/ENTER to enter the Lithium Battery Resistance program. The screen indicate each cell's resistance. The screen indicate the total resistance, the highest resistance and the lowest resistance. WARNING AND ERROR MESSAGE In case of an error the screen will display the cause of error and emit an audible sound. TIME LINE nia nm Incorrect polarity connected. The battery is interrupted. The battery connection is wrong. The balance connect is wrong Voltage of one cell in the battery pack is too low. Voltage of one cell in the battery pack is too high Voltage of one cell in the battery pack is invalid. The cell number is wrong. The internal temperature of the unit goes too high. The external temperature of the battery goes too high. The battery capacity is more than the maximum capacity which the user sets. The charging time is longer than the maximum charging time which the user sets. The battery voltage is higher than the maximum voltage which the user sets when charging in balance mode. Voltage of the battery pack is lower than SV. This charger can not charge battery whose voltage under 5V. S65 THE SET CONTAINS THE SET CONTAINS 1. SKYRC S65 Charger 2. Power Cord S65 21 SPECIFICATION © AC Input Voltage : 100-240V © Display Type: 2x16 LCD © Display Backlight: Blue © Case Material: Plastic © Controls: Four Buttons © Case Size: 118x115x45mm @ Weight: 315g External Port: 2-4S Balance Socket-XH, Temperature Probe Socket, XT60 Female Connector. Delta Peak Detection for NIMH/NiCd: 3-15mV/cell / Default: 4mV/cell © Battery Cutoff Temperature: 20°C/68°F-80°C/176°F (adjustable) Charge Voltage: NiMH/NiCd: Delta peak detection LiPo: 4.18-4.25V/cell Pb Normal:2.4V/cell LiHV:4.25-4.35V/cell Pb AGM:2.45V/cell LiFe: 3.58-3.7V/cell Pb Cold:2.45V/cell Lilon: 4.08-4.2V/cell Balance Current: 300mA/cell © Reading Voltage Range: 0.1-26.1V/cell © Battery Types/Cells: LiPo/LiHV/LiFe/Lilon: 2-4cells NiMH/NiCd: 6-8cells Pb: 3-6cells © Battery Capacity Range: NiMH/NiCd: 100-50000mAh LiPo/LiHV/LiFe/Lilon: 100-50000mAh Pb: 100-50000mAh © Charge Current: 0.1A-6.0A Safety Timer: 1-120minutes off ® Charge Wattage: 65W Discharge Current: 0.1A-2.0A © Discharge Cut-off Voltage: NiMH/NiCd: 0.1-1.1V/cell LiPo: 3.0-3.3V/cell — LiHV: 3.1-3.4V/Cell LiFe: 2.6-2.9V/cell —Lilon: 2.9—3.2V/cell Pb: 1.8-2.0V/cell © Discharge Wattage: 10W © Balance Cells: 2-4 cells Memory: 10 different charge/discharge profiles © Charge Method: CC/CV for lithium types and lead (Pb) batteries Delta-peak Sensitivity for NiIMH/NiCd. 22 S65 CONFORMITY DECLARATION SkyRC S65 satisfy all relevant and mandatory EC directives and FCC Part 15 Subpart B: ANSI C63.4:2014 SAFETY Standard Title Result Household and similar electrical EN 60335-1:2012+A11:2014 | appliances - Safety - Part 1: PASS General requirements EN 60335-2-29:2004+A2:2010 | Part 2-29: Particular requirements for battery chargers PASS EMISSION Standard Title Result Conducted (Main Port) PASS: EN 55014-1: 2006+A2:2011 Disturbance Power PASS EN 61000-3-2: 2014 Harmonic current emissions PASS EN 61000-3-3: 2013 Voltage fluctuations & flicker PASS IMMUNITY [EN 55014-2: 2015 } Standard Title Result IEC 61000-4-2: 2008 ESD PASS TEC 61000-4-3: 2006+A1:2007+A2:2010_| RS PASS IEC 61000-4-4: 2012 EFT PASS IEC 61000-4-5: 2014 Surge PASS IEC 61000-4-6: 2008 cs PASS IEC 61000-4-11: 2004 _| Voltage dips & voltage variations PASS EMISSION Standard Title Result Remarks FCC 47 CFR Part 15 Subpart B Conducted (Mains Port) PASS Meet Class B limit ANSI 063.4:2014 Radiated PASS —_| Meet Class B limit This symbol means that you must dispose of electrical from the General household waste when it reaches the end of its useful life. Take your charger to ™= your local waste collection point or recycling centre. This applies to all countries of the European Union, and to other European countries with a separate waste collection system. S65 23 COMMONLY USED TERMS Commonly used terms Final charge voltage: the voltage at which the battery's charge limit (capacity limit) is reached. The charge process switches from a high current to a low maintenance rate (trickle charge) at this point. From this point on further high current charging would cause overheating and eventual terminal damage to the pack. Final discharge voltage: the voltage at which the battery's discharge limit is reached. The chemical composition of the batteries determines the level of this voltage. Below this voltage the battery enters the deep discharge zone. Individual cells within the pack may become reverse polarized in this condition, and this can cause permanent damage. A, mA: unit of measurement relating to charge or discharge current.1000 mA = 1A (A=Ampere,mA=Milliampere) Ah, mAh: unit of measurement for the capacity of a battery (Amperes x time unit; h = hour). If a pack is charged for one hour at a current of 2 A, it has been fed 2 Ah of energy. It receives the same quantity of charge (2 Ah) if it is charged for 4 hours at 0.5A, or 15 minutes (=1/4 h) at 8A. ‘Crating: Capacity is also referred to as the ‘C’ rating. Some battery suppliers recommend charge and discharge currents based on the battery 'C' rating. A battery's 'C' current is the same number as the battery's rated capacity number, but noted in mA or amps. A 600mAh battery has a 1C current value of 600mA, and a 3C current value of (3 x 600mA) 1800mA or 1.8A. The 1C current value for a 3200mAh battery would be 3200mA (3.2A). Nominal voltage(V): The nominal voltage of the battery pack can be determined as follows; -.NiCd or NiMH: multiply the total number of cells in the pack by 1.2. A 8-cell pack will have a nominal voltage of 9.6 volts (8x1.2). -.LiPo: multiply the total number of cells in the pack by 3.7. A 3-cell LiPo wired in series will have a nominal voltage of 11.1 volts (3x3.7). -.Lilo: multiply the total number of cells in the pack by 3.6. A 2-cell Lilo wired in series will have a nominal voltage of 7.2 volts (2x3.6). -.LiFe: multiply the total number of cells in the pack by 3.3. A 4-cell Lilo wired in series will have a nominal voltage of 13.2 volts (4x3.3). If the nominal voltage of the battery is not printed on the battery's label, consult your battery manufacturer or supplier. Do not guess the rated voltage of battery. 24 S65 WARRANTY AND SERVICE Liability exclusion This charger is designed and approved exclusively for use with the types of battery stated in this Instruction Manual. SkyRC accepts no liability of any kind if the charger is used for any purpose other than that stated. We are unable to ensure that you follow the instructions supplied with the charger, and we have no control over the methods you employ for using, operating and maintaining the device. For this reason we are obliged to deny all liability for loss, damage or costs which are incurred due to the incompetent or incorrect use and operation of our products, or which are connected with such operation in any way.Unless otherwise prescribed by law, our obligation to pay compensation, regardless of the legal argument employed, is limited to the invoice value of those SkyRC products which were immediately and directly involved in the event in which the damage occurred Warranty and service THIS WARRANTY IS ONLY VALID IN THE COUNTRY OF PURCHASE AND THROUGH FORMAL DISTRIBUTOR. We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase. The warranty only applies to material or operational defects, which are present at the time of purchase. During that period, we will repair or replace free of service charge for products deemed defective due to those causes. For any repair or replace service, please contact your dealer in the first instance, who is responsible for processing guarantee claims. This warranty is not valid for any damage or subsequent damage arising as a result of misuse, modification or as a result of failure to observe the procedures outlined in this manual S65 25 SKYRC Manufactured by SKYRC TECHNOLOGY CO., LTD. www.skyre.com The manual is subject to change without notice; please refer to our website for the latest version! Printed in China ©2022.09 —7504-1120-05

You might also like