0% found this document useful (0 votes)
36 views

Ac Specification

The document appears to be a bill of quantities for electrical work. It lists various items and materials needed along with their quantities, units of measurement, and space to fill in unit prices. Key items included are single package ducted air conditioners, cassette type air coolers, and surface wiring with NYY or 2XY cables in various sizes to be run through PVC conduits. Specifications are provided for the air conditioners and coolers. The document requests unit prices be filled in for each item.

Uploaded by

Jonayed Hossain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

Ac Specification

The document appears to be a bill of quantities for electrical work. It lists various items and materials needed along with their quantities, units of measurement, and space to fill in unit prices. Key items included are single package ducted air conditioners, cassette type air coolers, and surface wiring with NYY or 2XY cables in various sizes to be run through PVC conduits. Specifications are provided for the air conditioners and coolers. The document requests unit prices be filled in for each item.

Uploaded by

Jonayed Hossain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 18

Table Bill of

Name : Quantities
Item Code
Item no. Group
(if any)
1 EM NA

2 EM NA
3(a) EM NA
3(a) EM NA

3(b) EM NA

3(c) EM NA

4(a) EM NA

4(b) EM NA

5 EM NA

6 EM NA
6 EM NA

7 EM NA

8 EM NA

9 EM NA

10 EM NA

11 EM NA
11 EM NA

12 EM NA

13 EM NA

14 EM NA

15 EM NA
Unit Price
Unit Price
Measurem (In
Description of Item Quantity (In words:
ent Unit figures:
BDT)
BDT)
Single Package Ducted Type A/C : Sets 3 Fill By Auto
Tenderer/C
''Supply of air cooled single package ducted type air conditioner unit onsultant -
having cooling capacity based on indoor temperature 270-300C DB Money
/19.5ºC-22ºC WB and outdoor temperature 35-40° C in/c hermetic Positive(3
compressor with crankcase heater, internal overload protection, high & digits after
low pressure cutout, anti-recycling time guard etc. complete, the decimal)
condenser fan shall be vertical discharge and axial flow type. The
motor shall be three- phase with external overload suitable for 400 V±
5%, 50 Hz. AC supply out-door application.

The evaporator fans shall be double inlet forward curved centrifugal


type, statically & dynamically balanced, horizontal/bottom (convertible)
discharge supply plenum coil section, filter section with filter, supply
and return air plenum, wall mounted remote temperature and fan
speed controller etc. (major components of the machine shall be
inconformity with relevant international standards.)'' Any brand
manufactured or assembled in JAPAN / MALAYSIA/ SOUTH/ KOREA/
TAIWAN/ THAILAND/ USA/ EU countries accepted/approved by the
Engineer in accordance with fulfillment of the above specifications and
having relevant certificates as mentioned. ''Brand: UNTES Country of
Origin: Turkey'' Capacity: Not Less then 300000 BTU/HR

Installation of Cassette Type Air-Cooler- 5 TR Nos 18 Fill By Auto


Tenderer/C
Supply, installation, testing & commissioning of split type air-cooler
onsultant -
non-inverter comprising condensing and evaporating units having
Money
following cooling capacity based on indoor temperature 27º-30ºC DB /
Positive(3
19.5º-22ºC WB and outdoor temperature 35º-40ºC DB at high fan
digits after
speed condition suitable for installation & operation in tropicalized
decimal)
country like Bangladesh & as per detailed specifications & standard as
mentioned below :

''OUTDOOR UNIT / CONDENSING UNIT


(1). Type : Compact weather proof outdoor type condensing unit

(2). Compressor : Hermitically sealed reciprocating / rotary


compressor.
(3). Refrigerant : Internationally accepted & recommended and most
commonly used gas (CFC free)

(4). Blower motor : Well balanced type direct driven centrifugal type
blower fan''
''(5). Power supply :
(5.1). 200-250 V, single phase, 50 Hz. AC supply [up to 30000
BTU/HR]
(5.2). 380-440 V 3-phase, 50 Hz. AC supply [above 30000 BTU/HR]

(6). Condensing pipe / coil : Made of copper


7). EER/COP :
For upto 60000 BTU/HR EER should be minimum 9.23
(BTU/HR)/WATT
and COP Should be minimum 2.70 (W/W) ''
''For above 60000 BTU/HR EER should be minimum 10.5
(BTU/HR)/WATT
and COP should be minimum=3.08 (W/W)(8). Others features :

(8.1). Well balanced in all respect having interlock with the fan coil
unit.''
''(8.2). Compressor dully equipped with vibration isolator, thermostatic
& overload controls, magnetic contactors and all other standard
accessories complete.

(8.3). Refrigerant copper pipe [From outdoor to indoor unit] with


thermal insulation, refrigerant charging arrangement etc.[ Minm
length10 mtr.]
(8.4). Reqd. size PVC insulated & sheathed cable with ECC through
water grade PVC pipe from outdoor to indoor unit.

(8.5) Sound level : maximum 65 dB(A) at 1 meter''


''INDOOR UNIT / FAN COIL UNIT
Features : (1). Direct expansion system fan coil unit with well balanced
direct driven centrifugal type fan.
(2). Fancy & adjustable air circulating louver grill, removable &
washable type filter .
(3). Condensing water drain out PVC flexible pipe with necessary
insulation
(4). Thermostatic switch and remote control switch.
(5). Sound level : maximum 44 dB(A) at 1 meter
''
''Standard : Major component shall be manufactured as per relevant
international standard & code.
Documents :Manufacturing company shall have the following certificate
:
(1). ISO-9001.
(2). CE Certification / UL Listing.
Warranty :
The bidder should provide the guaranty of compressor for at least 2
years & free service with spares for 2 years from the date of
commissioning & it should be obtained from the air cooler selling
agency.''

Any brand manufactured or assembled in JAPAN / MALAYSIA /


SOUTH KOREA / TAIWAN / THAILAND / USA / EU countries
accepted / approved by the engineer in accordance with fulfillment of
the above specifications and having relevant certificates as mentioned.

''Capacity : 58000-60000 BTU/HR


Cassette type''
Surface Wiring (NYY): Mtr 400 Fill By Auto
Tenderer/C
onsultant -
Money
Positive(3
digits after
decimal)
Mtr 400 Fill By Auto
Tenderer/C
Surface conduit wiring with the following PVC insulated and sheathed
onsultant -
stranded cable (NYY) / XLPE insulated and PVC sheathed stranded
Money
cable (2XY) & PVC insulated Green / Yellow bi-colour ECC wire (BYA)
Positive(3
through PVC conduit of reputed manufacturer complete with fixing
digits after
materials, other accessories etc. as required including mending the
decimal)
damages good.

All electrical contacts shall be of brass / copper connected through


connector or soldering (no twisting shall be allowed) and cables shall
be manufactured and tested according to IEC / BS / VDE standards
along with relevant BDS standard as per detailed specification
mentioned in Annexure-1. The work shall be carried out as per
direction & approval of the Engineer In Charge.

Cable manufacturer(s) must have valid type test certificate (within last
seven years) from internationally accredited laboratory (like CPRI,
KEMA etc.) accepted / approved by the Engineer In Charge

(a)1C-4x4sqmm (NYY / 2XY) with 4 sqmm (BYA) ECC wire through


PVC pipe of minimum inner dia 30 mm having wall thickness of 1.9 mm

-do- Mtr 195 Fill By Auto


Tenderer/C
(b)1C-4x10sqmm (NYY / 2XY) with 10 sqmm (BYA) ECC wire through
onsultant -
PVC pipe of minimum inner dia 40 mm having wall thickness of 2.2 mm
Money
Positive(3
-do- Mtr 800 Fill By Auto
Tenderer/C
(c)1C-4x95sqmm (NYY / 2XY) with 50 sqmm (BYA) ECC wire through
onsultant -
PVC pipe of minimum inner dia 75 mm having wall thickness of 3 mm
Money
Positive(3
REFRIGERENT COPPER PIPES WITH THERMAL INSULATION Mtr 300 Fill By Auto
Tenderer/C
Supply & installation of copper refrigerant pipe complete with all onsultant -
necessary pipe fitting such as bends, tees, reducers, sockets, gate Money
valves etc.as per drawing and direction. The concealed pipe shall be Positive(3
covered with pvc pipe with nitrile rubber insulation having thickness 19 digits after
mm for VRF system and thickness 13 mm for split type unit and be decimal)
installed with proper hangers supports, clamp as per site condition and
complying standard. Pipe work shall be tested unto the
recommendation and direction of Engineer-in-charge.

(a)Size: 3/8''dia copper tube For 5TR Discharge Line


-do- Mtr 300 Fill By Auto
Tenderer/C
(b)Size: 3/4''dia copper tube for 5 TR Suction Line
onsultant -
Condensing Drain Pipe (0.75'' Dia) with insulation & U-Traps Job 18 Fill By Auto
Tenderer/C
Providinng Fitting/ Fixing of uPVC pipe with Insulation for Condensing onsultant -
Drain Water Line. Water grade uPVC pipe dia-20mm, Thickness Money
1.5mm. Insulation shall be 0.75'' thick close-cell cross-linked Positive(3
polyethylene/ elastomeric type and shall be complete with adhesive digits after
backed with peel-off paper. The U-traps shall be made from PVC decimal)
material. Ø 0.75'' as per direction of the Engineer-in-charge.

Outdoor Unit Base Work Job 18 Fill By Auto


Tenderer/C
onsultant -
Money
Positive(3
digits after
decimal)
Job 18 Fill By Auto
Tenderer/C
Construction of Outdoor Unit CC Base on rooftop of PTB and making &
onsultant -
finishing Hole on Rooftop for Copper pipe and Electrical Power lone.
Money
Water sealed and net finishing for rooftop base arrangement as per
Positive(3
direction of the Engineer-in-charge.
digits after
decimal)
Galvanized cable tray Mtr 240 Fill By Auto
Tenderer/C
Supply, fitting and fixing galvanized cable tray made of 18 SWG (1.2
onsultant -
mm) MS Sheet evenly perforated with 7 mm width Capsule hole punch
Money
with self-Hanging Facility at top, joint clamp, including fabricating cost
Positive(3
of electricity, tools and plants, workshop charges, carriage of the same,
digits after
cutting groves in the RCC or brick work, mending good the damages
decimal)
with CC (1:2:4), etc. complete for all floors accepted by the Engineer.

300x100 mm without cover


Metal Ducting Work- 22 SWG GP Sheets Sft 345 Fill By Auto
Tenderer/C
Supply, installation and testing of metal ducts of different sizes as per
onsultant -
drawing and detail technical specification including supply of duct
Money
hanger/ isolator boxes, hanger rods, steel supports, all other materials
Positive(3
and consumables. Duct materials and construction shall be complete
digits after
as per detail specification and SMACNA standards. The work shall be
decimal)
complete as per instruction of Engineer-in-charge. and sample shall be
approved by the Engineer-in-Charge.

Ducts made of 22 SWG GP sheets


Duct Insulation- 1.0'' thick Sft 3989 Fill By Auto
Tenderer/C
Supply and installation of insulation on the outside surface of metal
onsultant -
ducts as per drawing and detail technical specification including supply
Money
of all materials and consumables. The work shall be complete as per
Positive(3
instruction of Engineer-in-charge. and samples shall be approved by
digits after
the Engineer-in-Charge.
decimal)

The insulation shall be fire retardant Close cell Nitrile Rubber class O.
It shall be adhesive backed with peel-off paper. The insulation shall
have a maximum allowable 'K' value of 0.04 W/m⁰C, with Self
Adhesive and Alu Foil Outside. Density: 50 kg/m3, Thermal
conductivity: 0.0362W/m.k.

Insulation shall be 1.0'' thick


Aluminium Jacketing work- 26 SWG (0.45mm) Sft 3989 Fill By Auto
Tenderer/C
Supply and installation of 26 SWG (0.45mm) Aluminium Jacketing on
onsultant -
Nitrile Rubber on Metal Duct. The work shall be complete as per
Money
instruction of Engineer-in-charge. and samples shall be approved by
Positive(3
the Engineer-in-Charge.
digits after
decimal)
Aluminium Jacketing work- 26 SWG (0.45mm)
Flexible Duct Joint/ Connection Nos 3 Fill By Auto
Tenderer/C
onsultant -
Money
Positive(3
digits after
decimal)
Nos 3 Fill By Auto
Tenderer/C
Supply and installation of flexible ducts to make connection between
onsultant -
equipment viz. FCU, AHU, FA-AHU, HRU-FA/AHU, EAF and Ducts as
Money
per drawing and detail technical specification including supply of all
Positive(3
materials and consumables. The work shall be complete as per
digits after
instruction of Engineer-in-charge. and sample shall be approved by the
decimal)
Engineer-in-Charge.

Fresh Air Louver Nos 3 Fill By Auto


Tenderer/C
Supply and installation of Fresh Air Louver constructed of extruded
onsultant -
aluminium/ galvanized steel sheet, complete with bird/ rodent screen.
Money
The work shall be complete as per instruction of Engineer-in-charge.
Positive(3
and sample shall be approved by the Engineer-in-Charge.
digits after
decimal)

200A TPDB: Nos 3 Fill By Auto


Tenderer/C
Supply & installation of 415V , 3 phase , 50Hz , Out door type LT
onsultant -
Feeder panel board of Minimum Size: 5'-0''x2'-6'', Depth: 2'-0'' of the
Money
following specification complete with bus bar and following components
Positive(3
(including busbar) component manufactured SWITZERLAND
digits after
/FRANCE/ JAPAN/ ITALY/ or equivalent approved by the Engineering
decimal)
in charge.

Locally factory assembled in 16 SWG sheet steel clad dust & vermin
powder coated painted cabinet (MCCB's, MCB's in LT panel must
comply NEMA/ VDE/ JIS/ BSS standard. The work shall be completed
as required i/c RCC base as per direction of the engineer in charge.

''Incoming:
1 set 415V, 300A TP+NL Busbar
Voltmeter_2 Nos
Phase indicator_6 Nos
Ammeter_1 Nos
2 X 200A TPMCCB
(Duel Incoming with Mechanical Interlock) ''
''Outgoing:
63A TPMCCB_2 Nos
20A TPMCB_18 Nos
6/10/16/20A SPMCB_9 nos''
Dismantling Work- Existing Package Type A/C Job 3 Fill By Auto
Tenderer/C
Carefully Dismantling the existing Package type A/C unit from rooftop
onsultant -
and stored near old power house or recommended places, complete
Money
by using proper equipments like crane, Truck by skilled manpower and
Positive(3
as per direction of the Engineer-in-charge.
digits after
decimal)
Installation, Testing & Commissioning of Package Type A/C Job 3 Fill By Auto
Tenderer/C
Installation, Testing & Commissioning as per technical specification of onsultant -
the supplied air cooled single package ducted type air conditioner unit Money
on Rooftop of PTB on Existing Base/ recommended placed, complete Positive(3
by using proper equipments like crane, Truck by skilled manpower and digits after
as per direction of the Engineer-in-charge. decimal)
Fill By Auto
Tenderer/C
onsultant -
Money
Positive(3
digits after
decimal)
Total Total
Price (In Price (In
figures: words:
BDT) BDT)
Auto Auto

Auto Auto
Auto Auto
Auto Auto

Auto Auto

Auto Auto

Auto Auto

Auto Auto

Auto Auto

Auto Auto
Auto Auto

Auto Auto

Auto Auto

Auto Auto

Auto Auto

Auto Auto
Auto Auto

Auto Auto

Auto Auto

Auto Auto

Auto Auto
Auto Auto

You might also like