HCIA-Datacom

Lab Construction Guide

For Version 1.0


HUAWEI TECHNOLOGIES CO., LTD.
Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Huawei Technologies Co., Ltd.


Training & Certification Dept.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://learning.huawei.com
Email: [email protected]

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd
Revision History
For Version Date Description

1.0 2020.3 New version

Guide Information
Author Time Range Reader

Talent Ecosystem Regional Offices, Suppliers, & Huawei Authorized


2020.3-…
Development Dept Learning Partners (HALP).

Content

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd
Contents

s
1 About this Document.......................................................................................................................1
2 The HCIA Lab Topology.................................................................................................................1
3 Equipment Purchasing....................................................................................................................2
4 Cable Connection............................................................................................................................2
5 Problems Caused by Non-standard Equipment...........................................................................4
6 Remote management.......................................................................................................................4
6.1 Cable Connection and Configuration.................................................................................................................4
6.1.1 Serial port server connection topology.....................................................................................................5
6.1.2 Example for Configuring a Serial Port Server..........................................................................................5
6.2 Console cable preparation..................................................................................................................................6

7 Precautions.......................................................................................................................................6

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd
1 About this Document
After the HCIA experiment has been standard, the experimental equipment was determined. In
consideration of demand for the upgrading of teaching materials and the compatibility with the HCIP-
Datacom, generating a list of experimental equipment and physical connection topology.
This guide provides supporting information for HAINA, regional offices, suppliers, and Huawei Authorized
Learning Partners (HALP) for the purchase of equipment, installation of modules, cables, and configuration
of related equipment required for construction of the Huawei HCIA lab environment, and aid in supporting
the corresponding lab training, as part of the Huawei Certified ICT Associate (HCIA) course.

2 The HCIA Lab Topology

Figure 2-1 HCIA –Datacom Physical Topology

The physical topology shown in Figure 2-1 contains all equipment on the purchase list.

1
3 Equipment Purchasing
You must purchase the equipment based on the lab requirements. If you have any doubt, send email to
[email protected].

4 Cable Connection
The equipment must be connected based on the topology shown in Figure 2-1.
Ensure that the correct models are used for the different types of equipment based on the mapping
provided in .

Table 4-1 Required model for different types of equipment

Equipment Model

R1 AR6121E
R2 AR6121E
R3 AR6121E
S1 S5731-H24T4XC
S2 S5731-H24T4XC
S3 S5731-H24P4XC
S4 S5731-H24P4XC
AP1 AirEngine5761-11
AP2 AirEngine5761-11

2
Check whether the ports are connected correctly based on .
Table 4-2 Required mapping between ports

GE0/0/1 S1
R1 GE0/0/2 S2
GE0/0/3 R2
GE0/0/1 S1
GE0/0/2 S2
R2
GE0/0/3 R1
GE0/0/4 R3
GE0/0/1 S1
R3 GE0/0/2 S2
GE0/0/3 R2
GE0/0/1 R1
GE0/0/2 R2
GE0/0/3 R3
GE0/0/10 S2
S1
GE0/0/11 S2
GE0/0/12 S2
GE0/0/13 S3
GE0/0/14 S4
GE0/0/1 R1
GE0/0/2 R2
GE0/0/3 R3
GE0/0/10 S1
S2
GE0/0/11 S1
GE0/0/12 S1
GE0/0/13 S3
GE0/0/13 S4
GE0/0/1 S1
GE0/0/2 S2
S3
GE0/0/3 S4
GE0/0/4 AP1

3
GE0/0/1 S1
GE0/0/2 S2
S4
GE0/0/3 S3
GE0/0/4 AP2
AP1 GE0/0/1 S3
AP2 GE0/0/2 S4

5 Problems Caused by Non-standard Equipment


You must use the standard equipment contained on the equipment list in HCIA-Datacom V1.0 Equipment
List.
The non-standard equipment may cause problems, including but not limited to the following items:
1. The commands may be found to be incompatible, or the interface names are not consistent with the ones
in the lab guide.
2. Parts of the lab results cannot be displayed.
3. The non-standard equipment is not compatible with the lab guide or learning materials of later versions.

6 Remote management

6.1 Cable Connection and Configuration


If you want to remotely manage the experiment devices, you can purchase an AR6140E router and configure two
8-port asynchronous serial interface cards. The AR6140E can be used as a serial port server for unified
management and connect the AR6140E to your network. You can use Telnet to connect and manage the serial
ports of all devices.

4
6.1.1 Serial port server connection topology

Connect the serial port of the experiment device to the asynchronous serial port of the AR6140E (the card needs to
be purchased separately). Configure the serial port server on the AR6140E, and connect the AR6140E to your
network. The management terminal can access the IP address-oriented management port of the AR6140E through
Telnet to remotely manage the serial port of the experiment device.
The cable used to connect the serial port and asynchronous serial port of the experimental equipment is a
dedicated cable. The cable sequence is mentioned below. You can make the cable by yourself.

6.1.2 Example for Configuring a Serial Port Server


For details about how to configure the serial port server, see the following example:
1. Configuring the Async Port
interface Async5/0/0
undo detect dsr-dtr
async mode flow
Configure the port mode.

2. Configuring TTY
user-interface tty 33
undo shell
idle-timeout 0 0
redirect enable
redirect listen-port 3001

Set the redirection port number of TTY 33 to TCP 3001.


Configure the connection between the AR6140E and the user network.

5
After the preceding configuration, you can use Telnet to access the IP address and TCP port 3001 of the AR6140E
to access the serial port of the experiment device connected to Async5/0/0. In this way, you can remotely manage
the serial port of the AR6140E.

6.2 Console cable preparation


Both ends of the dedicated cable must be RJ-45 connectors. You are advised to manually prepare the cable. The
method of manufacturing is based on the method of manufacturing straight-through twisted pair. The line
sequence follows the table below.

Port Type\No. 1 2 3 4 5 6 7 8

Green Blue
Orange Brown
Async port Orange and blue and Green Brown
White White
white white
Green Blue
Brown Orange
Console port and and blue Green Orange Brown
White White
white white

7 Precautions
After the instructor conducts training of the learning materials, the students are expected to independently
carry out and complete the steps listed in the HCIA Lab Guide. If any fault occurs, the students should
ask for troubleshooting support from the instructor.
For all the AR6121E routers, interface GE0/0/0~GE0/0/7 are switch port by default, instructor should
configure them to be layer three port by using command ’undo portswitch’ and save as default
configuration.
In the experiment, in order to avoid the influence of residual configuration on the experiment, after the
completion of the experiment, students should delete the equipment configuration information before
closing the equipment; at the same time, at the beginning of the experiment, confirm the equipment from
the empty configuration, or perform configuration empty, and restart the equipment.