HCIA-Datacom V1.0 Lab Environment Setup Guide
HCIA-Datacom V1.0 Lab Environment Setup Guide
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Guide Information
Author Time Range Reader
Content
s
1 About this Document.......................................................................................................................1
2 The HCIA Lab Topology.................................................................................................................1
3 Equipment Purchasing....................................................................................................................2
4 Cable Connection............................................................................................................................2
5 Problems Caused by Non-standard Equipment...........................................................................4
6 Remote management.......................................................................................................................4
6.1 Cable Connection and Configuration.................................................................................................................4
6.1.1 Serial port server connection topology.....................................................................................................5
6.1.2 Example for Configuring a Serial Port Server..........................................................................................5
6.2 Console cable preparation..................................................................................................................................6
7 Precautions.......................................................................................................................................6
The physical topology shown in Figure 2-1 contains all equipment on the purchase list.
1
3 Equipment Purchasing
You must purchase the equipment based on the lab requirements. If you have any doubt, send email to
[email protected].
4 Cable Connection
The equipment must be connected based on the topology shown in Figure 2-1.
Ensure that the correct models are used for the different types of equipment based on the mapping
provided in .
Equipment Model
R1 AR6121E
R2 AR6121E
R3 AR6121E
S1 S5731-H24T4XC
S2 S5731-H24T4XC
S3 S5731-H24P4XC
S4 S5731-H24P4XC
AP1 AirEngine5761-11
AP2 AirEngine5761-11
2
Check whether the ports are connected correctly based on .
Table 4-2 Required mapping between ports
GE0/0/1 S1
R1 GE0/0/2 S2
GE0/0/3 R2
GE0/0/1 S1
GE0/0/2 S2
R2
GE0/0/3 R1
GE0/0/4 R3
GE0/0/1 S1
R3 GE0/0/2 S2
GE0/0/3 R2
GE0/0/1 R1
GE0/0/2 R2
GE0/0/3 R3
GE0/0/10 S2
S1
GE0/0/11 S2
GE0/0/12 S2
GE0/0/13 S3
GE0/0/14 S4
GE0/0/1 R1
GE0/0/2 R2
GE0/0/3 R3
GE0/0/10 S1
S2
GE0/0/11 S1
GE0/0/12 S1
GE0/0/13 S3
GE0/0/13 S4
GE0/0/1 S1
GE0/0/2 S2
S3
GE0/0/3 S4
GE0/0/4 AP1
3
GE0/0/1 S1
GE0/0/2 S2
S4
GE0/0/3 S3
GE0/0/4 AP2
AP1 GE0/0/1 S3
AP2 GE0/0/2 S4
6 Remote management
4
6.1.1 Serial port server connection topology
Connect the serial port of the experiment device to the asynchronous serial port of the AR6140E (the card needs to
be purchased separately). Configure the serial port server on the AR6140E, and connect the AR6140E to your
network. The management terminal can access the IP address-oriented management port of the AR6140E through
Telnet to remotely manage the serial port of the experiment device.
The cable used to connect the serial port and asynchronous serial port of the experimental equipment is a
dedicated cable. The cable sequence is mentioned below. You can make the cable by yourself.
2. Configuring TTY
user-interface tty 33
undo shell
idle-timeout 0 0
redirect enable
redirect listen-port 3001
5
After the preceding configuration, you can use Telnet to access the IP address and TCP port 3001 of the AR6140E
to access the serial port of the experiment device connected to Async5/0/0. In this way, you can remotely manage
the serial port of the AR6140E.
Port Type\No. 1 2 3 4 5 6 7 8
Green Blue
Orange Brown
Async port Orange and blue and Green Brown
White White
white white
Green Blue
Brown Orange
Console port and and blue Green Orange Brown
White White
white white
7 Precautions
After the instructor conducts training of the learning materials, the students are expected to independently
carry out and complete the steps listed in the HCIA Lab Guide. If any fault occurs, the students should
ask for troubleshooting support from the instructor.
For all the AR6121E routers, interface GE0/0/0~GE0/0/7 are switch port by default, instructor should
configure them to be layer three port by using command ’undo portswitch’ and save as default
configuration.
In the experiment, in order to avoid the influence of residual configuration on the experiment, after the
completion of the experiment, students should delete the equipment configuration information before
closing the equipment; at the same time, at the beginning of the experiment, confirm the equipment from
the empty configuration, or perform configuration empty, and restart the equipment.