0% found this document useful (0 votes)
29 views1 page

RD196B RMB SHD Sew 000008 R2

The document presents a key plan with various model numbers listed across the top and room numbers down the left side. It allows one to see which encryption models correspond to which rooms. The plan provides a mapping between 12 rooms (1-12) and different encryption module models (MC5A, MC5J, MC5K, etc.) to support secure communication needs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views1 page

RD196B RMB SHD Sew 000008 R2

The document presents a key plan with various model numbers listed across the top and room numbers down the left side. It allows one to see which encryption models correspond to which rooms. The plan provides a mapping between 12 rooms (1-12) and different encryption module models (MC5A, MC5J, MC5K, etc.) to support secure communication needs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7 8 9 10 11 12

KEY PLAN

MC5J

MC60

MC5M
MC5J

MC5A
MC5K

MC5M
MC60

MC5A
MC5K

MC5A
MC5J

MC5L
MC5M
MC5A

MC5K

MC60

MC5H

MC5H
MC5I
MC5K

MC5M
MC20

MC5D
MC5K

MC5F
MC20

AD

MC5D
MC5A

MC5A

RO
MC5A
MC5B

MC5K
MC20

MC5M
MC60
MC5J
MC5A
O

MC5J
MC20
P

MC5B
EX
MC20

MC5B
MC20

MC20

MC20

A A
MC20

MC20

MC20

MC20

VAB

VAB

VAB

PETROL
VAB VAB

VAB

ACCESS
132kv
VAB

VAB
VAB

PETROL
ACCESS
132kv
VAB VAB

VAB

VAB

VAB VAB

VAB

VAB

VAB

62 18
17 20
19 23
22
21

25
24 26
27 28 30
29 32
31 34
33 35 36

DUBAI RESIDENTIAL DISTRICT


58 16
15

61 57
56 37
38 14
13
12

39
55
54 40
41 11
10

60 53
52
51 43 42 09
08

59 50
49 44
45 07
06

48 47
46 05

03 04

02
01

PHASE - 3

NOTES:-
1, ALL DIMENSIONS SHOWN ON STANDARD DETAIL
DRAWINGS ARE IN MILLIMETERS UNLESS
OTHERWISE INDICATED
2, ALL EXPOSED EDGES TO HAVE A 25mm X 25mm CHAMFER.
3,ALL GRP BUILT -IN PIPES THROUGH WALLS OF UNIT SHALL
B B
BE PROTECTED FROM JOINT STRESS FRACTURE IN
ACCORDANCE WITH THE SPECIFICATION
4, ALL INTERNAL WALLS, FLOOR AND SOFFIT OF ROOF SLAB
UNITS SHALL BE PROTECTED IN ACCORDANCE WITH THE
A A SPECIFICATION.
5, ALL EXTERNAL SURFACES AND TOPS OF BLINDING AREAS
TO BE PROTECTED IN ACCORDANCE WITH THE
SPECIFICATION
6, ALL STRUCTURAL STEEL SHALL CONFORM TO BS
4360:1986 GRADE 43A/ASTM A.36ALL STRUCTURAL
MEMBERS SHALL BE HOT DIP GALVANIZED AND PAINTED
AS PER SPECIFICATIONS
7,ALL STAINLESS STEEL ITEMS SHALL BE TO MINIMUM
GRADE316 L UNLESS OTHERWISE SPECIFIED.
8,DETAILS OF MECHANICAL EQUIPMENT, PIPE WORK,VALVES,
PENSTOCK, SUPPORTS, PLINTHS, COVER OPENINGS,
C C
REBATES ETC. SHOWN ON THE DRAWINGS ARE FOR
GUIDANCE ONLY. THE CONTRACTOR SHALL PREPARE
AND SUBMIT THE SHOP DRAWINGS PRIOR TO
CONSTRUCTION AS PER THE APPROVED EQUIPMENT
MANUFACTURER REQUIREMENT FOR APPROVAL BY THE
ENGINEER.
9,THERE SHALL NOT BE ANY STRUCTURAL OBSTRUCTION
FOR REMOVAL OF AND RE-FIXING ANY BOLT OR TIE-BAR
FOR DISMANTLING JOINT
COVER PLAN 10,ALL ACCESS COVERS 600 X 750 OR 600 X 900 OR
MULTIPLES SHALL BE RECESSED WITH CONCRETE IN-FILL,
HEAVY DUTY AND SLID OUT TYPE.
11,THE SIZE OF CLEAR OPENING FOR THE COVERS SHALL BE
ADJUSTED TO SUIT THE NEAREST AVAILABLE SIZE OF
PLAN COVERS FROM THE COVER MANUFACTURER.
12,CONCRETE SUPPORT TO BE MINIMUM 50mm FROM
D FLANGES (TO ALLOW FOR REMOVAL OF BOLTS) AND D
EXTENDED 100mm BEYOND BODY OF FITTINGS,
UNLESS OTHERWISE SHOWN
13,ALL NUTS, BOLTS & NUTS ETC. OF AIR VALVES AND
FITTINGS TO BE STAINLESS STEEL GRADE 316 OR A4-70
14, SS 316 LADDER TO BE INSTALLED IN ALL CHAMBERS.
15,ALL FITTINGS SHALL BE OF GRP.

SHOP DRAWING
REV. DATE DESCRIPTION APPD.
E E
0 19-09-23 FOR APPROVAL

1 17-10-23 FOR APPROVAL

2 24-10-23 FOR APPROVAL

CLIENT F

CONSULTANT:
F

DESIGN CONSULTANT

G
ACE International Consulting Engineers
TEL-04 5766828, FAX- 04 5766821 Email: [email protected]
P.O.BOX - 62309,DUBAI, U.A.E

CONTRACTOR:
G

PROJECT TITLE

DUBAI SOUTH RESIDENTIAL DISTRICT


PHASE - 3
DRAWING TITLE
WASHOUT CHAMBER
H
SECTION A-A REIFORCEMENT DETAILS
FOR SEWER LINE (Ø250 mm) H

Drawn : AK Checked : PM Reviewed: PM

Date : 19-09-23 Scale: NTS Approved: PM


Drawing No : Sheet 02 of 02
RD196B-RMB-SHD-SEW-000008 Revision 2